變(bian)壓(ya)(ya)器(qi)運行(xing)時,電(dian)(dian)流(liu)(liu)通過鐵心(xin)產生交(jiao)變(bian)磁(ci)通就會發(fa)出(chu)“嗡(weng)(weng)嗡(weng)(weng)”的(de)(de)均(jun)勻(yun)電(dian)(dian)磁(ci)聲(sheng)(sheng),聲(sheng)(sheng)響(xiang)(xiang)的(de)(de)強弱(ruo)正比于運行(xing)電(dian)(dian)壓(ya)(ya)和負荷電(dian)(dian)流(liu)(liu)的(de)(de)大小(xiao)。這是變(bian)壓(ya)(ya)器(qi)正常運行(xing)的(de)(de)聲(sheng)(sheng)響(xiang)(xiang)。如果出(chu)現(xian)其它的(de)(de)聲(sheng)(sheng)響(xiang)(xiang),則說明變(bian)壓(ya)(ya)器(qi)出(chu)現(xian)了故障。

現以6/0.4KV配電變(bian)壓器為例分析如下(xia):

1.變壓器“吱(zhi)(zhi)吱(zhi)(zhi)”聲(sheng)當分接(jie)(jie)開關(guan)調壓之(zhi)后(hou),響聲(sheng)加重。以雙臂(bei)電(dian)橋測試其直流(liu)電(dian)阻值,均超過出廠原始數據的2%,屬接(jie)(jie)觸(chu)(chu)**,系觸(chu)(chu)頭(tou)有污垢而引起的。

處理方法:旋開(kai)分(fen)接開(kai)關(guan)的風雨罩(zhao),卸下(xia)鎖緊螺釘,用扳手把(ba)分(fen)接開(kai)關(guan)的轉軸左(zuo)右(you)往復旋轉10~15次,即(ji)可消除這種現象,修復后立即(ji)裝配還(huan)原。

2.變壓(ya)器(qi)“噼啪(pa)”的清脆擊鐵聲這是高(gao)壓(ya)引(yin)線通過空(kong)氣(qi)對變壓(ya)器(qi)外殼的放電聲,系變壓(ya)器(qi)油箱(xiang)上部缺油所致(zhi)。

處理(li)方法:用(yong)清潔干燥的(de)(de)漏斗從油(you)枕(zhen)注油(you)孔加(jia)入經試(shi)驗合格的(de)(de)變壓器油(you),補油(you)量加(jia)至油(you)面線(xian)+20℃處為(wei)宜。如條(tiao)件允(yun)許,應采用(yong)真空(kong)注油(you)法以排(pai)除(chu)繞組(zu)中的(de)(de)氣泡(pao)。

3.變壓器沉悶(men)的“噼啪(pa)”聲這是高壓引線通過變壓器油(you)對外(wai)殼放電,屬絕緣(yuan)油(you)中含有水分(fen),造成(cheng)對地(di)距離不夠(gou)。

驅(qu)潮的方(fang)法:短接變壓(ya)器低(di)壓(ya)側(ce)引線(xian)柱,并在其(qi)(qi)高(gao)壓(ya)側(ce)接入(ru)低(di)壓(ya)三相交(jiao)流電(dian)(240~330V),用調(diao)壓(ya)器調(diao)整(zheng)此電(dian)壓(ya),使(shi)(shi)流過變壓(ya)器高(gao)壓(ya)繞組(zu)的(de)電(dian)流不(bu)大于其(qi)(qi)額(e)定(ding)電(dian)流。該電(dian)流不(bu)僅使(shi)(shi)高(gao)壓(ya)和(he)低(di)壓(ya)繞組(zu)產(chan)(chan)生銅(tong)損(sun),同時也產(chan)(chan)生漏磁通(tong)。漏磁通(tong)通(tong)過鐵(tie)心(xin)和(he)結構件(jian),產(chan)(chan)生渦流損(sun)耗。銅(tong)損(sun)和(he)鐵(tie)損(sun)產(chan)(chan)生的(de)熱量能使(shi)(shi)變壓(ya)器油(you)、繞組(zu)、鐵(tie)質部件(jian)的(de)水分受到均勻加熱而蒸發出來,均通(tong)過油(you)枕呼吸塞排(pai)出箱(xiang)外。此時若低(di)壓(ya)繞組(zu)開路(lu),則(ze)有16~22V的(de)輸出電壓(ya),也可作為油(you)箱產生渦流發熱的(de)電源。

其做(zuo)法是(shi):從配(pei)電(dian)變(bian)壓(ya)器(qi)(qi)的(de)低壓(ya)繞(rao)組a、b、c端(duan)子上(shang),分別接(jie)出(chu)10~16mm2塑(su)料鋁芯(xin)線,分別在油箱外殼上(shang)、中(zhong)、下纏(chan)繞(rao)3匝(za)之后,均(jun)接(jie)于(yu)配(pei)電(dian)變(bian)壓(ya)器(qi)(qi)低壓(ya)繞(rao)組中(zhong)性線端(duan)子上(shang),所產(chan)生的(de)渦流發出(chu)的(de)熱量(liang)能(neng)使配(pei)電(dian)變(bian)壓(ya)器(qi)(qi)油箱受到均(jun)勻(yun)加熱,進(jin)一(yi)步(bu)提(ti)高配(pei)電(dian)變(bian)壓(ya)器(qi)(qi)的(de)干燥質(zhi)量(liang)。這里需要指(zhi)出(chu),若焙烘的(de)溫(wen)度高于(yu)配(pei)電(dian)變(bian)壓(ya)器(qi)(qi)的(de)額定溫(wen)度,去掉B相(xiang)電(dian)源(yuan)后即可降低干燥時(shi)的(de)溫(wen)度。

4.變壓器似蛙(wa)鳴(ming)的(de)“唧哇唧哇”聲在變壓器的(de)外部電源(yuan)回路有(you)虛接點時,會發出這種(zhong)聲音(yin),且聲響(xiang)不均,時強時弱(ruo)。可配合電壓表的(de)指示值進行判斷,若B相缺電,則電壓大致(zhi)為:Uab=230V,Uac=400V,Ubc=230V,Uao=230V,Ubo=0V,Uco=230V

處理方法(fa):立即安排停電并檢修(xiu)。一般(ban)發生在高壓架(jia)空線(xian)路(lu)上,如導線(xian)與隔離(li)開關的(de)(de)連接(jie)、耐張段內的(de)(de)接(jie)頭、跌落(luo)式熔斷器的(de)(de)接(jie)觸(chu)點及下引(yin)線(xian)接(jie)頭出現斷線(xian)、松動(dong)或接(jie)觸(chu)**。待故障(zhang)排除(chu)后(hou),方可(ke)允許投入運(yun)行。

5.變壓(ya)(ya)器嗡(weng)嗡(weng)聲響(xiang)減弱變壓(ya)(ya)器停運(yun)后(hou)送電(dian)(dian)(dian)(dian)(dian)或新安(an)裝竣工后(hou)投(tou)產驗(yan)收(shou)送電(dian)(dian)(dian)(dian)(dian),往往發現電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)不正常,這(zhe)是(shi)高壓(ya)(ya)引線(xian)較(jiao)細,運(yun)行發熱(re)斷線(xian),或經過長(chang)途運(yun)輸、搬運(yun)不當(dang)或跌落式熔(rong)斷器的(de)熔(rong)絲(si)熔(rong)斷及接(jie)觸**所致(zhi)。在(zai)低壓(ya)(ya)側測(ce)量電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya),會(hui)出(chu)現三相相電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)數值(zhi)不等、一相為零(Yyn0接(jie)法(fa)時),這(zhe)是(shi)兩相供電(dian)(dian)(dian)(dian)(dian)所致(zhi)。當(dang)變壓(ya)(ya)器運(yun)行時,電(dian)(dian)(dian)(dian)(dian)流(liu)通(tong)過鐵心(xin)產生的(de)交(jiao)變磁(ci)通(tong)在(zai)減弱,故從變壓(ya)(ya)器內發出(chu)音響(xiang)較(jiao)小的(de)“嗡(weng)嗡(weng)”的(de)均勻電(dian)(dian)(dian)(dian)(dian)磁(ci)聲。

處理方法:

(1)測(ce)(ce)試高壓(ya)繞(rao)(rao)組的(de)(de)(de)(de)直流電阻值(zhi)。若變壓(ya)器(qi)(qi)設置(zhi)有(you)分(fen)接(jie)開關,應(ying)測(ce)(ce)量每一擋的(de)(de)(de)(de)數據(ju)(ju),分(fen)Ⅰ、Ⅱ、Ⅲ進行AB、BC、CA直流電阻值(zhi)的(de)(de)(de)(de)測(ce)(ce)量,并注意將(jiang)運行中(zhong)的(de)(de)(de)(de)一擋放(fang)在*后(hou)測(ce)(ce)量,測(ce)(ce)完之后(hou)不再(zai)切換。儀表(biao)用單臂或(huo)雙臂電橋,待自(zi)感消逝(shi)、指針穩定后(hou)進行測(ce)(ce)試。1600KVA及以下三相(xiang)(xiang)(xiang)變壓(ya)器(qi)(qi)各(ge)相(xiang)(xiang)(xiang)測(ce)(ce)得值(zhi)的(de)(de)(de)(de)相(xiang)(xiang)(xiang)互(hu)差值(zhi)應(ying)小于(yu)平(ping)(ping)均(jun)值(zhi)的(de)(de)(de)(de)4%,線間測(ce)(ce)得值(zhi)的(de)(de)(de)(de)相(xiang)(xiang)(xiang)互(hu)差值(zhi)應(ying)小于(yu)平(ping)(ping)均(jun)值(zhi)的(de)(de)(de)(de)2%;1600KVA以上三相(xiang)(xiang)(xiang)變壓(ya)器(qi)(qi)各(ge)相(xiang)(xiang)(xiang)測(ce)(ce)得值(zhi)的(de)(de)(de)(de)相(xiang)(xiang)(xiang)互(hu)差值(zhi)應(ying)小于(yu)平(ping)(ping)均(jun)值(zhi)的(de)(de)(de)(de)2%,線間測(ce)(ce)得值(zhi)的(de)(de)(de)(de)相(xiang)(xiang)(xiang)互(hu)差值(zhi)應(ying)小于(yu)平(ping)(ping)均(jun)值(zhi)的(de)(de)(de)(de)1%;各(ge)個繞(rao)(rao)組測(ce)(ce)試值(zhi)之差,以不超過出廠(chang)原(yuan)始數據(ju)(ju)的(de)(de)(de)(de)±2%為合格,否則應(ying)屬(shu)接(jie)觸**,可用第1條中(zhong)的(de)(de)(de)(de)方法處理。

(2)測試(shi)低(di)壓繞組的直流電阻值。ab、bc、ca的不平衡率應在±1%內。

(3)跌(die)落式熔(rong)斷器的(de)接(jie)(jie)觸**。一般產(chan)生于熔(rong)器上的(de)上觸頭,原(yuan)因是(shi)壓(ya)力不夠(gou)而引(yin)起。可用(yong)拉閘桿迫使上觸頭往下壓(ya)緊(jin),且與熔(rong)芯接(jie)(jie)觸可靠。

6.變壓器特(te)殊(shu)(shu)噪(zao)聲(sheng)由于負載和周(zhou)圍環境(jing)溫度的(de)(de)(de)變化,油(you)(you)枕(zhen)(zhen)的(de)(de)(de)油(you)(you)面線(xian)發(fa)(fa)生(sheng)變化,因此,水(shui)蒸氣伴隨空氣一(yi)并被吸入(ru)油(you)(you)枕(zhen)(zhen)內,凝(ning)成水(shui)珠(zhu),促使內部(bu)氧化生(sheng)銹。隨著積(ji)聚程度加(jia)劇,鐵銹會(hui)落到油(you)(you)枕(zhen)(zhen)的(de)(de)(de)下部(bu)。鐵銹通過油(you)(you)枕(zhen)(zhen)與油(you)(you)蓋的(de)(de)(de)連通管,堆積(ji)在(zai)部(bu)分鐵軛(e)上,從(cong)而在(zai)電磁力的(de)(de)(de)作(zuo)用下產(chan)生(sheng)振動,發(fa)(fa)出特(te)殊(shu)(shu)噪(zao)聲(sheng)。這還會(hui)導(dao)致變壓器運行油(you)(you)中(zhong)機(ji)械雜(za)質增(zeng)多,惡化油(you)(you)質。

處理方法:油(you)枕與集(ji)泥器(qi)的(de)清潔是同時進行的(de),應根據變壓(ya)器(qi)的(de)負荷情況、溫升狀(zhuang)況來決定(ding)。使用經驗證(zheng)明,兩年清潔一次*好(hao).


尊敬的客戶:
       您好,我公司主營產品:變頻串聯諧振耐壓試驗裝置、高壓試驗變壓器、直流高壓發生器、微機繼電保護測試儀、大電流發生器、真空度測試儀、直流電阻測試儀、變比組別測試儀、互感器綜合測試儀等產品。您可以通過網頁撥打本公司的服務專線了解更多產品的詳細信息,至善至美的服務是我們永無止境的追求,歡迎新老客戶放心選購自己心儀的產品。

您的選擇是對我們*大的支持,若您在使用中遇到任何困難和問題,請及時與我公司取的聯系,我們將竭誠為您提供*好的服務.

產品目錄
Copyright? 2003-2024 揚(yang)州萬(wan)寶電力設備有限公司版權所有    地址:江蘇省揚州寶應柳堡工業園(yuan)萬寶路1號    郵(you)編:225828
電話:0514-88771393 0514-88778599     傳真:0514-88771019   

多功能微機繼電保護測試儀,多功能型鉗形接地電阻儀,手持全自動變比測試儀,發電機水內冷直流高壓發生器,無線高壓變比測試儀,漏電流監控記錄儀,三相相序表,非接觸型檢相器