回路電阻測試儀更新換代十次,每次都有大不同一、產品簡介
WBHL-2000回路(lu)電阻測試(shi)儀(yi)是公司根據IEC標準及中華人民共(gong)和國*新電力執行標準DL/T845.4- 2004有關(guan)規定,發揮自身技術優勢(shi),精(jing)心研制的(de)高精(jing)度、數字化開關(guan)檢測(ce)(ce)(ce)儀器。該儀器采用(yong)高頻大功率(lv)恒(heng)流(liu)(liu)開關(guan)電(dian)(dian)(dian)(dian)(dian)源(yuan)技術,可測(ce)(ce)(ce)得微歐姆級接(jie)觸(chu)電(dian)(dian)(dian)(dian)(dian)阻(zu)(zu)。廣(guang)泛適用(yong)于(yu)各種開關(guan)及(ji)電(dian)(dian)(dian)(dian)(dian)器的(de)接(jie)觸(chu)電(dian)(dian)(dian)(dian)(dian)阻(zu)(zu)、回(hui)路(lu)(lu)電(dian)(dian)(dian)(dian)(dian)阻(zu)(zu)及(ji)電(dian)(dian)(dian)(dian)(dian)纜電(dian)(dian)(dian)(dian)(dian)線、焊縫接(jie)觸(chu)電(dian)(dian)(dian)(dian)(dian)阻(zu)(zu)的(de)測(ce)(ce)(ce)量(liang)(liang),儀器測(ce)(ce)(ce)量(liang)(liang)數據(ju)準確(que),性能穩(wen)定,滿足(zu)電(dian)(dian)(dian)(dian)(dian)力、供電(dian)(dian)(dian)(dian)(dian)部門現場(chang)高壓開關(guan)維修和(he)高壓開關(guan)廠回(hui)路(lu)(lu)電(dian)(dian)(dian)(dian)(dian)阻(zu)(zu)測(ce)(ce)(ce)試的(de)要(yao)求。輸出電(dian)(dian)(dian)(dian)(dian)流(liu)(liu)和(he)測(ce)(ce)(ce)量(liang)(liang)電(dian)(dian)(dian)(dian)(dian)阻(zu)(zu)同時輸出在65K真彩色液晶上(shang),測量(liang)結(jie)果即可(ke)(ke)電壓輸出也可(ke)(ke)U盤存(cun)儲(chu),掉電(dian)存(cun)儲(chu)可滿足隨時數據查詢(xun)。
回路電阻測試儀更新換代十次,每次都有大不同二、性能特點
1、測試電流大,完全符合(he)有(you)關(guan)測試接觸電阻的國(guo)家(jia)標(biao)準要(yao)求。
2、輸出電壓(ya)高(gao),測量(liang)量(liang)程(cheng)寬。
3、測(ce)試(shi)電(dian)流來自高精(jing)度的大電(dian)流恒流電(dian)源,無需人工調節,測(ce)試(shi)迅速準確。
4、采用四端(duan)子接線法(fa),有效地排除了測試(shi)線電阻對測試(shi)結果的影(ying)響(xiang)。
5、320X240點(dian)陣的(de)超小像素(su)點(dian)的(de)65K真彩色液(ye)晶,
6、儀器自帶萬年歷時(shi)(shi)鐘和掉電存(cun)儲(chu)(chu),可存(cun)儲(chu)(chu)測(ce)試數據,隨時(shi)(shi)查閱
7、儀器配備(bei)微型(xing)打印機、RS232和(he)USB接口,可和計算機通(tong)訊以及U盤存儲
8、智能化功率管理技(ji)術,儀器(qi)總是工(gong)作(zuo)在*小功率狀態,有(you)效節約能源。
回路電阻測試儀更新換代十次,每次都有大不同三、技術指標(biao)
1、測試電流:100A,200A,400A,600A;
2、量程:0~200mΩ
3、分辨率:*小0.1μΩ
4、精(jing)度(du):±(0.5%±2個字)
5、功(gong)率(lv):1000-4000W
6、工作方式:連續(xu)測量
7、工(gong)作電源(yuan):AC220V±10% 50HZ
8、使用(yong)溫(wen)度:0~40℃
9、相對(dui)濕度:小(xiao)于等于90% 無結露
10、外形尺寸(cun):355*275*147
11、重量:9.5-20KG
回路電阻測試儀更新換代十次,每次都有大不同四、操作(zuo)功能介紹
1、電源開關:“I”按下儀器開始供電,“O”按(an)下關斷儀器電源
2、AC220V:儀器供(gong)電源輸入端,本(ben)儀器采(cai)用交流220V供(gong)電
3、I+、I-:為(wei)電流輸出端(duan)子,通過專用測(ce)試(shi)(shi)線為(wei)試(shi)(shi)品提供100A恒定電流(liu)
4、V+、V-:為試品電壓信號的輸(shu)入端子
5、液(ye)晶:采用320X240真(zhen)彩色液晶,強(qiang)光(guang)下(xia)字體也可(ke)清晰觀察,顯示操(cao)作(zuo)設置,測試(shi)結果,接觸電阻值和輸出電流值
6、RS232:串口(kou)輸出端
7、復位鍵:整(zheng)機初始化(hua),儀器處在準(zhun)備狀(zhuang)態
8、選擇鍵(jian):按下此鍵(jian),選擇儀器(qi)各項設置,測量結束可打印數(shu)據
9、循(xun)環鍵:主菜單循(xun)環選(xuan)擇鍵或(huo)U盤存儲
9、確認鍵:按下確認鍵儀器(qi)開始啟(qi)動電流進行測試
10、:儀器接地(di)端。
11、 USB:U盤接(jie)口
12、打(da)(da)印(yin)機:熱敏打(da)(da)印(yin)機,打(da)(da)印(yin)測量結果
回路電阻測試儀更新換代十次,每次都有大不同五、菜單操作
開機菜單(dan)顯(xian)示如(ru)下:
按循環(huan)鍵(jian)(jian)光(guang)標(biao)(biao)可在(zai)參數(shu)(shu)(shu)設置、數(shu)(shu)(shu)據(ju)查詢、時(shi)(shi)(shi)(shi)鐘修(xiu)改、測(ce)量時(shi)(shi)(shi)(shi)間、選擇(ze)電(dian)流之(zhi)間循環(huan)移動,光(guang)標(biao)(biao)在(zai)參數(shu)(shu)(shu)設置、數(shu)(shu)(shu)據(ju)查詢、時(shi)(shi)(shi)(shi)鐘修(xiu)改時(shi)(shi)(shi)(shi)按選擇(ze)鍵(jian)(jian)可進(jin)入選中菜單(dan)的下**菜單(dan),光(guang)標(biao)(biao)在(zai)測(ce)量時(shi)(shi)(shi)(shi)間項按選擇(ze)鍵(jian)(jian)時(shi)(shi)(shi)(shi)間可在(zai)脈沖、30秒(miao)、1分鐘(zhong)、5分鐘、10分鐘(zhong)、連續之間循(xun)環(huan)移動(dong),任何(he)時候(hou)按(an)啟(qi)動(dong)鍵可進入測量狀(zhuang)態,
六、測量方(fang)法
注意:測試鉗的(de)全(quan)部(bu)連(lian)接面(mian)(mian)應與試品可(ke)靠接觸(chu)(chu),若發現接觸(chu)(chu)面(mian)(mian)有氧化(hua)現象,應首先去除接觸(chu)(chu)面(mian)(mian)的(de)氧化(hua)層。
1、接(jie)(jie)線方法(fa):如(ru)圖(tu)二(er)所示,將專用測試線按照顏色(se)紅(hong)對紅(hong),黑對黑,粗的電流線接(jie)(jie)到對應的I+、I-接線(xian)柱扭緊(jin),細(xi)的電源線(xian)插入到(dao)V+、V-的插座內,兩(liang)把(ba)夾(jia)鉗夾(jia)住被(bei)測試品的兩(liang)端。
2、測量(liang):接圖二完成接線后,打開電(dian)源開關,選擇好(hao)測試(shi)時(shi)間進行測試(shi),儀器會(hui)自動完成充電(dian)、穩流和電(dian)阻測量(liang)。
3、操作步驟(zou):
1)、按要求完成儀(yi)器端和被測量(liang)試品端的接線
2)、接通(tong)AC220V交流電源,打開(kai)(kai)電源開(kai)(kai)關(guan),屏幕如前面講到的開(kai)(kai)機(ji)界面,通過選擇鍵(jian)選擇適合的測量(liang)時間后,按(an)下啟動(dong)鍵(jian)柯(ke)進入測量(liang)過程(cheng)
3)、當選擇好測量時(shi)間時(shi),按下啟動鍵儀器啟動電流(liu),屏幕顯示(shi)(shi)“正在充電”同(tong)時(shi)顯示(shi)(shi)儀器輸出(chu)電流(liu),電流(liu)輸出(chu)達到預定值且穩定后,屏幕顯示(shi)(shi)“正在測試”,幾秒鐘后顯示(shi)(shi)被測阻值及電流(liu)值
4)、測(ce)(ce)試過程中如果(guo)想(xiang)保(bao)存測(ce)(ce)試值,按下選擇鍵約2秒開始打印當前數據,測(ce)(ce)量(liang)時間到達后儀器(qi)停止測(ce)(ce)量(liang),屏幕不再閃動,并顯示(shi)提示(shi)儀器(qi)如何打印和U盤存儲
5)、測試過(guo)程中(zhong)按下復位鍵或(huo)測試結(jie)束,儀器(qi)輸(shu)出電流均(jun)變(bian)為零,測量結(jie)束后,應先關閉電源,然后拆除引線,準備下一個試驗(yan)項目。
七、**措施
1、操作者應具備一(yi)般電器設備或(huo)儀器的使用常識。
2、測(ce)試結束(shu)后,按復位鍵,關(guan)掉電(dian)源開關(guan)。注意(yi):嚴禁帶電(dian)拆裝各測(ce)試電(dian)纜。
3、儀器出現不正(zheng)常(chang)現象,首先按復(fu)位鍵,使(shi)儀器復(fu)位。
4、對(dui)儀(yi)器進行(xing)維修必須由專業人(ren)員進行(xing),不得自行(xing)處(chu)理。
5、本儀器為測量(liang)回(hui)路電阻使用,不允許(xu)測量(liang)感(gan)性(xing)回(hui)路。
八、儀(yi)器成套(tao)組成
主(zhu)機
|
一臺
|
測試線
|
一套
|
電(dian)源線
|
一條
|
操作手冊
|
一本(ben)
|
九、售后(hou)服(fu)務
儀器自購買之(zhi)日起壹年內屬產品(pin)質量(liang)問(wen)題免費包(bao)修(xiu)包(bao)換,終身提供保修(xiu)和(he)技術服務。如發現(xian)儀器有不正(zheng)常情況或故障,請與公司及時聯系,以便為(wei)您安(an)排*便捷的處理(li)方案。