一、WBYD2000變頻串并聯諧振耐壓試驗設備基本原理
耐壓(ya)(ya)試驗是利用電(dian)抗器的(de)(de)電(dian)感與被(bei)(bei)試品電(dian)容組成LC串聯回路,調節變頻(pin)電(dian)源輸出的(de)(de)電(dian)壓(ya)(ya)頻(pin)率(lv),在被(bei)(bei)試品上獲得高(gao)電(dian)壓(ya)(ya),是當前高(gao)電(dian)壓(ya)(ya)試驗的(de)(de)一種新方法,深受專家好評(ping),在國內(nei)外(wai)已經(jing)得到廣泛的(de)(de)使用。
根據諧振(zhen)(zhen)原理,我(wo)們知道當電(dian)抗(kang)器L的(de)感抗(kang)值Xl與回(hui)路中的(de)容抗(kang)值Xc相等時,回(hui)路達(da)到(dao)諧振(zhen)(zhen)狀態,此時回(hui)路中僅回(hui)路電(dian)阻R消(xiao)耗有功功率,而(er)無功功率則在電(dian)抗(kang)器與試品電(dian)容之間來回(hui)振(zhen)(zhen)蕩,從而(er)在試品上產生高壓。
二、WBYD2000變頻串并聯諧振耐壓試驗設備系統構成
全套試驗(yan)系統由調頻(pin)電(dian)源主機(ji)、電(dian)抗器(qi)(qi)、分壓(ya)器(qi)(qi)、激勵(li)變壓(ya)器(qi)(qi)和(he)補償電(dian)容器(qi)(qi)(可選(xuan)器(qi)(qi)件)組成,接(jie)入被(bei)試品后組成一個諧振系統進行交流耐壓(ya)實驗(yan)。
主(zhu)機: 就是一(yi)臺幅(fu)值(zhi)和頻(pin)率(lv)可調的正弦波交流(liu)調頻(pin)電源,給諧振(zhen)回路提供激勵源,同時提供電壓顯示(shi)(shi)、電流(liu)顯示(shi)(shi)、計時、保護、報(bao)警(jing)等功(gong)能。
電(dian)抗器(qi)(qi):就是一個(ge)大電(dian)感線圈,與被試品(相(xiang)當于電(dian)容)構成回路,可配置電(dian)抗器(qi)(qi)多節電(dian)抗器(qi)(qi),使(shi)用(yong)時(shi)通過不同的(de)串聯、并聯組合(he)、實現不同的(de)電(dian)感量以適用(yong)不同的(de)試驗條(tiao)件。
分(fen)(fen)壓(ya)器:內(nei)部通過(guo)電容(rong)器分(fen)(fen)壓(ya),從試品上高電壓(ya)分(fen)(fen)得低電壓(ya)供主機測量、控制使用(yong)。
勵(li)磁(ci)變(bian)壓器:隔(ge)離主(zhu)機電(dian)源與諧振回(hui)路(lu)電(dian)源,并升高主(zhu)機的輸出電(dian)壓。
補償(chang)電容(rong)器:當(dang)試(shi)品(pin)電容(rong)量很小(xiao)時,如(ru)果要(yao)實現系(xi)統諧振(zhen)可能要(yao)求的電源頻率超(chao)出試(shi)驗標準的規定,可在試(shi)品(pin)上并聯一個補償(chang)電容(rong),以實現試(shi)驗要(yao)求,稱此電容(rong)器為(wei)補償(chang)電容(rong)器。
三、WBYD2000變頻串并聯諧振耐壓試驗設備主要技術性能
功(gong)率電源電壓:AC380V±10%、50Hz;
儀器(qi)電源:220V±10%、50Hz;
諧(xie)振輸出容量:200kVA;
儀器(qi)額定電壓:0~200kV;
輸(shu)出(chu)頻率(lv)范圍:30~300Hz;
輸出電壓(ya)波形:正弦波,波形畸變率<0.5%;
頻(pin)率調節靈敏度:0.1Hz,不穩定(ding)度≤0.05%;
系統噪聲:≤60db;
9、系統測量精度:<1級(ji);
10.輸出電壓不穩(wen)定(ding):<0.5%;
11.保護響應時(shi)間:1us;
12.電感非(fei)線性度:≤0.05%;;
13.滿功率輸(shu)出下,連(lian)續工(gong)作時間為60min
14.環境溫度(du):-15℃~+50℃;
15.相(xiang)對濕度:≤90%RH;
16.海拔高度:≤2000米。
四、WBYD2000變頻串并聯諧振耐壓試驗設備面板及部件名稱
五、WBYD2000變頻串并聯諧振耐壓試驗設備操作步驟
1、正確連線,檢(jian)查無(wu)誤后方可(ke)送電(dian)。
必(bi)要(yao)時工作電(dian)源(yuan)的跳(tiao)過現場漏電(dian)保(bao)安器,以免不必(bi)要(yao)的跳(tiao)閘。
2、打開(kai)電源開(kai)關(guan),主機開(kai)始工作,液晶屏顯(xian)示版權頁,該頁標(biao)明(ming)本(ben)(ben)裝置的軟件(jian)版本(ben)(ben)號。
觸(chu)按確(que)認鍵(jian),進入系統菜(cai)單(dan),該主菜(cai)單(dan)下有:試(shi)(shi)驗(yan)方案、開始試(shi)(shi)驗(yan)、試(shi)(shi)驗(yan)幫助(zhu)、系統設置、實用工具和試(shi)(shi)驗(yan)記(ji)錄(lu)等六個子菜(cai)單(dan)項。
3、 系(xi)統(tong)(tong)設(she)(she)置(zhi)菜單(dan)(dan)(dan)下有電抗(kang)器電感(gan)、日期時間(jian)設(she)(she)置(zhi)和采樣系(xi)數(shu)設(she)(she)置(zhi)等三個(ge)子菜單(dan)(dan)(dan)項。按上下鍵,上下移動(dong)光標系(xi)統(tong)(tong)參數(shu)設(she)(she)置(zhi)菜單(dan)(dan)(dan)項,觸按確定(ding)鈕后,進(jin)入系(xi)統(tong)(tong)參數(shu)設(she)(she)置(zhi)菜單(dan)(dan)(dan),可以(yi)分別設(she)(she)定(ding)電抗(kang)器的電感(gan)—H、-年-月-日、-時-分-秒(miao)和電壓和電流的采樣系(xi)數(shu)也就(jiu)是(shi)采樣倍率(lv),設(she)(she)定(ding)完成后,觸按返(fan)還鍵返(fan)回上**菜單(dan)(dan)(dan)。
電抗器電感量的(de)設定(ding):按(an)確(que)定(ding)鍵(jian)選擇到此項,按(an)左右鍵(jian)移動光標(biao)需要改變(bian)的(de)數(shu)(shu)位(wei),按(an)上下鍵(jian)改變(bian)數(shu)(shu)值(zhi)(zhi),達到所要達到的(de)數(shu)(shu)值(zhi)(zhi)按(an)確(que)定(ding)鍵(jian)確(que)認。
日期時間的(de)(de)設定:按(an)確(que)定鍵(jian)(jian)選擇到此項(xiang),按(an)左右(you)鍵(jian)(jian)移動光(guang)標需(xu)要改變的(de)(de)數(shu)位,按(an)上下鍵(jian)(jian)改變數(shu)值(zhi)(zhi),按(an)照所要設置的(de)(de)年月日時間數(shu)值(zhi)(zhi)按(an)確(que)定鍵(jian)(jian)確(que)認。
采(cai)樣(yang)系(xi)數的(de)設(she)定:按(an)確(que)定鍵(jian)選擇到高壓/電流采(cai)樣(yang)系(xi)數項,此項為(wei)電壓或(huo)電流采(cai)樣(yang)倍率的(de)設(she)定。一般(ban)出廠前設(she)定好(hao)了。如需(xu)修改,要輸入(ru)密碼。(密碼廠家與設(she)備一起提供一般(ban)設(she)定為(wei):188888)
警告(gao):系(xi)統默認上一(yi)次(ci)電(dian)(dian)(dian)(dian)抗(kang)(kang)器電(dian)(dian)(dian)(dian)感(gan)、日(ri)期(qi)時(shi)間和采樣系(xi)數設定(ding)值。如果(guo)需改變要重(zhong)新設定(ding)。電(dian)(dian)(dian)(dian)抗(kang)(kang)器電(dian)(dian)(dian)(dian)感(gan)量設定(ding)值與實際(ji)使(shi)用的(de)電(dian)(dian)(dian)(dian)抗(kang)(kang)器電(dian)(dian)(dian)(dian)感(gan)量不(bu)(bu)對,會(hui)導(dao)致試(shi)驗(yan)報告(gao)中(zhong)的(de)被試(shi)品電(dian)(dian)(dian)(dian)容(rong)量不(bu)(bu)準。其他并不(bu)(bu)會(hui)影響。采樣系(xi)數設置不(bu)(bu)正確,會(hui)導(dao)致顯(xian)示(shi)電(dian)(dian)(dian)(dian)壓(ya)電(dian)(dian)(dian)(dian)流不(bu)(bu)準將很有可能會(hui)對被試(shi)品或(huo)試(shi)驗(yan)設備造(zao)成(cheng)損壞。
4、試驗方(fang)案(an)菜(cai)單下有預置(zhi)(zhi)保護電流(liu)、找頻起始(shi)頻率(lv)(lv)(lv)、找頻結束(shu)(shu)頻率(lv)(lv)(lv)、預定(ding)起始(shi)功(gong)率(lv)(lv)(lv)四個(ge)子菜(cai)單項,分(fen)別設定(ding)本次(ci)試驗的(de)保護電流(liu)、找頻起始(shi)頻率(lv)(lv)(lv)、找頻結束(shu)(shu)頻率(lv)(lv)(lv)、輸出起始(shi)功(gong)率(lv)(lv)(lv),全(quan)部設定(ding)完成后,觸按返還鍵進(jin)入預置(zhi)(zhi)試驗電壓和(he)預置(zhi)(zhi)試驗時間(jian)設置(zhi)(zhi)菜(cai)單。
可(ke)以分(fen)3段(duan)時(shi)間設(she)置(zhi)試驗(yan)電壓和試驗(yan)時(shi)間, 實際試驗(yan)時(shi),若設(she)定為自(zi)動(dong)試驗(yan), 裝置(zhi)將按設(she)定的3段(duan)電壓及時(shi)間,按順序分(fen)別加壓, 全部完成后自(zi)動(dong)退出.
如果**段(duan)電壓(ya)(ya)設(she)為(wei)0, 或時間設(she)為(wei)0, 那么(me)執行完(wan)**段(duan)試(shi)驗(yan)電壓(ya)(ya)加壓(ya)(ya)后退出試(shi)驗(yan), 只加壓(ya)(ya)**段(duan)設(she)定的(de)電壓(ya)(ya).
如(ru)果第三(san)段電壓設為0, 或時間設為0, 不執行第三(san)段加壓.
試(shi)(shi)驗(yan)方(fang)案設(she)置(zhi)的(de)設(she)定(ding):在試(shi)(shi)驗(yan)電壓項中,按(an)(an)確定(ding)單鈕,移動左右光(guang)標到(dao)需要改(gai)變的(de)數(shu)(shu)位(wei),按(an)(an)上(shang)下單鈕以改(gai)變當前數(shu)(shu)位(wei)的(de)數(shu)(shu)值(zhi)大小(xiao),觸(chu)按(an)(an)返回鈕完(wan)成(cheng)當前數(shu)(shu)位(wei)的(de)數(shu)(shu)值(zhi)設(she)定(ding),依次選擇下一項數(shu)(shu)值(zhi)的(de)設(she)定(ding),直(zhi)至分別完(wan)成(cheng)試(shi)(shi)驗(yan)時間、起(qi)始(shi)頻(pin)率、起(qi)始(shi)功(gong)率的(de)設(she)置(zhi),方(fang)可完(wan)成(cheng)本(ben)次試(shi)(shi)驗(yan)的(de)試(shi)(shi)驗(yan)方(fang)案設(she)置(zhi)的(de)設(she)定(ding)。
出廠默認值:試驗電(dian)壓 20kV、加(jia)壓時間 2min、激勵強度 2%、輸出電(dian)流20A、頻率范(fan)圍30-300Hz。
5、實用工具菜單下有(you)
頻(pin)率計算:在實驗前可對(dui)諧振頻(pin)率進行計算。只需輸入具體參與試驗的(de)電感、電容值并按確定(ding)鍵試驗頻(pin)率即直接生成(cheng)。
6、開始試驗菜(cai)單(dan)下有自動試驗模式(shi)和手(shou)動試驗模式(shi)兩種子(zi)菜(cai)單(dan)可供選擇。
按確認鍵進(jin)入所選(xuan)試驗(yan)步驟.
自動試驗模式的(de)操作:選中自動試驗模式后,觸按菜(cai)單鈕進入正(zheng)在自動尋(xun)找諧(xie)振點(dian)菜(cai)單項(xiang),裝置在設定的(de)頻(pin)率(lv)范圍(wei)(wei)(wei)內(nei)自動尋(xun)找諧(xie)振點(dian)(如果被(bei)試品電(dian)容C和電(dian)抗(kang)器電(dian)感L的(de)實際(ji)諧(xie)振頻(pin)率(lv)不在設定的(de)頻(pin)率(lv)范圍(wei)(wei)(wei)內(nei),將(jiang)找不到諧(xie)振點(dian),此(ci)時根據需要調整(zheng)頻(pin)率(lv)范圍(wei)(wei)(wei)或調整(zheng)被(bei)試品回路的(de)LC參數)。當(dang)找到諧(xie)振點(dian)時,會(hui)有聲音(yin)提示。
找到諧振(zhen)點后,裝置自(zi)動進入正在(zai)自(zi)動升壓菜單(dan)項,當升到試(shi)驗電壓設定的電壓時,裝置停止加(jia)壓。
當裝(zhuang)置升到(dao)試驗(yan)電(dian)壓(ya)(ya)(ya)設(she)(she)定(ding)的電(dian)壓(ya)(ya)(ya)時(shi),設(she)(she)備停止(zhi)加(jia)壓(ya)(ya)(ya),自(zi)動(dong)進入正在加(jia)壓(ya)(ya)(ya)試驗(yan)菜(cai)單(dan)項,并自(zi)動(dong)記錄試驗(yan)的加(jia)壓(ya)(ya)(ya)時(shi)間(jian),當加(jia)壓(ya)(ya)(ya)時(shi)間(jian)到(dao)達設(she)(she)定(ding)時(shi)間(jian)時(shi),設(she)(she)備逐步降壓(ya)(ya)(ya)退(tui)出試驗(yan),完成本次試驗(yan),進入試驗(yan)結束菜(cai)單(dan)項。并可選(xuan)擇保存試驗(yan)數(shu)據或打印試驗(yan)數(shu)據。
試驗時間的(de)(de)一行顯示(shi)末端(duan),會(hui)顯示(shi)[一段(duan)(duan)(duan)(duan)]或(huo)[二段(duan)(duan)(duan)(duan)]或(huo)[三段(duan)(duan)(duan)(duan)]字樣,表(biao)示(shi)當前正(zheng)在進(jin)行的(de)(de)加(jia)壓試驗是(shi)預置(zhi)的(de)(de)一段(duan)(duan)(duan)(duan),二段(duan)(duan)(duan)(duan)或(huo)三段(duan)(duan)(duan)(duan).
手(shou)動試(shi)驗模式(shi)的(de)(de)(de)操作:選(xuan)中手(shou)動試(shi)驗模式(shi)后(hou)觸按(an)確定鈕(niu),進(jin)入正(zheng)在試(shi)驗菜單項(xiang);手(shou)動按(an)調(diao)(diao)頻(pin)(pin)鈕(niu),對(dui)應的(de)(de)(de)光標隨之改變(bian)到輸出頻(pin)(pin)率(lv)項(xiang),可以通(tong)過(guo)上(shang)下(xia)左右鍵改變(bian)頻(pin)(pin)率(lv)大(da)小使其試(shi)驗電(dian)壓(ya)逐(zhu)步升高,當升到*高電(dian)壓(ya)時(shi)(shi),繼續向(xiang)上(shang)或向(xiang)下(xia)調(diao)(diao)整頻(pin)(pin)率(lv)按(an)鈕(niu),直(zhi)至(zhi)試(shi)驗電(dian)壓(ya)開始下(xia)降;這時(shi)(shi)反(fan)調(diao)(diao)頻(pin)(pin)率(lv),試(shi)驗電(dian)壓(ya)又逐(zhu)步回(hui)升,上(shang)下(xia)回(hui)調(diao)(diao)頻(pin)(pin)率(lv),從頻(pin)(pin)率(lv)的(de)(de)(de)高位到低位逐(zhu)位調(diao)(diao)整*高電(dian)壓(ya)值(zhi)時(shi)(shi)的(de)(de)(de)頻(pin)(pin)率(lv)就是當前(qian)的(de)(de)(de)諧振頻(pin)(pin)率(lv)。
找到(dao)(dao)諧振點后,手動(dong)按電(dian)(dian)壓(ya)(ya)(ya)(ya)鈕(niu),光標到(dao)(dao)了(le)輸(shu)出功(gong)率,隨之按上下鍵增加(jia)輸(shu)出功(gong)率,試(shi)驗(yan)(yan)(yan)電(dian)(dian)壓(ya)(ya)(ya)(ya)也(ye)逐步(bu)升(sheng)高,當升(sheng)到(dao)(dao)試(shi)驗(yan)(yan)(yan)電(dian)(dian)壓(ya)(ya)(ya)(ya)設定電(dian)(dian)壓(ya)(ya)(ya)(ya)值時,裝置(zhi)停止加(jia)壓(ya)(ya)(ya)(ya),并(bing)有屏(ping)幕顯示(shi)提示(shi)和(he)聲音提示(shi);自動(dong)進入(ru)正在加(jia)壓(ya)(ya)(ya)(ya)試(shi)驗(yan)(yan)(yan)菜單(dan)項,并(bing)自動(dong)記(ji)錄試(shi)驗(yan)(yan)(yan)的加(jia)壓(ya)(ya)(ya)(ya)時間(jian),當到(dao)(dao)達加(jia)壓(ya)(ya)(ya)(ya)時間(jian)設定時間(jian)時,設備逐步(bu)降(jiang)壓(ya)(ya)(ya)(ya)退出試(shi)驗(yan)(yan)(yan),完成本次(ci)試(shi)驗(yan)(yan)(yan),進入(ru)試(shi)驗(yan)(yan)(yan)結束(shu)菜單(dan)項。
注意:在(zai)調(diao)(diao)(diao)(diao)節頻率調(diao)(diao)(diao)(diao)整(zheng)鈕(niu)(niu)的(de)過(guo)程(cheng)中(zhong),觸按(an)左右鈕(niu)(niu),可(ke)以(yi)改變(bian)頻率調(diao)(diao)(diao)(diao)節的(de)速度實(shi)現(xian)粗細(xi)(xi)調(diao)(diao)(diao)(diao)的(de)切換(huan)(huan)。在(zai)調(diao)(diao)(diao)(diao)節電壓調(diao)(diao)(diao)(diao)整(zheng)鈕(niu)(niu)的(de)過(guo)程(cheng)中(zhong),向(xiang)下觸按(an)左右鈕(niu)(niu),可(ke)以(yi)改變(bian)電壓的(de)升(sheng)降(jiang)的(de)速度實(shi)現(xian)粗細(xi)(xi)調(diao)(diao)(diao)(diao)的(de)切換(huan)(huan)。觸按(an)調(diao)(diao)(diao)(diao)頻、調(diao)(diao)(diao)(diao)壓鈕(niu)(niu),實(shi)現(xian)調(diao)(diao)(diao)(diao)頻與調(diao)(diao)(diao)(diao)壓間的(de)切換(huan)(huan)。
7、進入試驗記錄查詢菜單項,查詢以往和當前試驗數(shu)據。選(xuan)擇(ze)上下鍵(jian)翻(fan)看前一組(zu)數(shu)據后一組(zu)數(shu)據;選(xuan)擇(ze)左右鍵(jian)可選(xuan)擇(ze)打(da)印或刪除當前頁的內容(rong)。
125/456為試驗數(shu)(shu)據庫指針,分子是試驗數(shu)(shu)據的在(zai)數(shu)(shu)據庫的順序(xu)數(shu)(shu),分母是當(dang)前(qian)的數(shu)(shu)據總數(shu)(shu),*多可(ke)儲存999組(zu)試驗數(shu)(shu)據。
8、裝置和(he)試(shi)驗(yan)狀態菜單(dan)提示:設備(bei)的(de)(de)使用和(he)升壓(ya)和(he)耐壓(ya)試(shi)驗(yan)過程(cheng)中,如果(guo)出現影響試(shi)驗(yan)設備(bei)、被試(shi)驗(yan)設備(bei)以(yi)及操作人(ren)的(de)(de)**情況,設備(bei)可能出現自(zi)動(dong)保護(hu)轉臺,并在屏幕有相應(ying)的(de)(de)提示。
不(bu)能諧(xie)(xie)振(zhen):如果諧(xie)(xie)振(zhen)點不(bu)在諧(xie)(xie)振(zhen)頻率設(she)置的范(fan)圍內;系統連線不(bu)正確(que)等現(xian)象,裝置將(jiang)找不(bu)到諧(xie)(xie)振(zhen)點,這時裝置和試驗狀態(tai)菜單中的不(bu)能諧(xie)(xie)振(zhen)項被反(fan)白(bai)并閃爍。
輸(shu)出保護(hu):如果裝(zhuang)置的(de)電(dian)源輸(shu)出電(dian)流大于(yu)輸(shu)出保護(hu)設定(ding)的(de)電(dian)流值,裝(zhuang)置自動保護(hu),這時裝(zhuang)置和試驗(yan)狀態菜(cai)單中的(de)輸(shu)出保護(hu)項(xiang)被反白并閃爍。
試驗(yan)中止:如(ru)果(guo)在試驗(yan)升壓或加壓過程出現閃絡現象,裝(zhuang)置(zhi)(zhi)自動(dong)保(bao)護(hu),這時裝(zhuang)置(zhi)(zhi)和試驗(yan)狀態(tai)菜單(dan)中的輸(shu)出保(bao)護(hu)項被反白(bai)并閃爍。
9、試驗幫助內容包括五大項(xiang)分(fen)別(bie)為:1.版(ban)本信息2.接線示(shi)意3.使用說明4.常(chang)見(jian)問(wen)題5.參(can)考資料.如常(chang)見(jian)問(wen)題FAQ分(fen)五幅畫面(mian)顯(xian)示(shi)、各種被試品(pin)電力電纜、變壓器、發電機電容參(can)數的查詢:
接線示意圖:
10、設(she)(she)備(bei)(bei)出廠參(can)數設(she)(she)置(zhi)是生產廠家(jia)的出廠設(she)(she)置(zhi)參(can)術和校(xiao)驗(yan)(yan)參(can)數,不適當的設(she)(she)置(zhi)和修改會影響(xiang)設(she)(she)備(bei)(bei)性能和高壓試驗(yan)(yan)的**性,未經廠家(jia)授權密碼,無法修改。
警告:正常試驗(yan)狀態下(xia),按(an)返回鍵即(ji)可中止試驗(yan)。中止或(huo)結束試驗(yan)后,應分(fen)離刀閘切(qie)斷(duan)電(dian)源。在(zai)升(sheng)壓或(huo)加壓過程中,非緊急情(qing)況,不要按(an)下(xia)急停鍵。
六、本說明書(shu)的專屬名(ming)詞的定義
自動試(shi)驗:高壓(ya)試(shi)驗全過程(cheng)由主機(ji)按程(cheng)序和預置參(can)數(shu)自動完成。
自(zi)動調(diao)諧:調(diao)諧由主機(ji)按程(cheng)序自(zi)動完成,升(sheng)壓手動完成。
手(shou)動(dong)試驗:尋找諧振點和(he)升壓均為手(shou)動(dong),通過面(mian)板旋鈕(niu)完成。
系統參(can)數設置是指對設備部件參(can)數的設置。
試驗(yan)參(can)數(shu)(shu)設置是指對試驗(yan)過程(cheng)參(can)數(shu)(shu)的設置。
試驗(yan)模式選(xuan)擇是指對試驗(yan)模式的(de)選(xuan)擇。
試(shi)驗(yan)結果查詢是指對(dui)試(shi)驗(yan)數據的查詢。
分(fen)(fen)壓器變比是指(zhi)對分(fen)(fen)壓器的(de)分(fen)(fen)壓比設置。
電(dian)抗(kang)器(qi)電(dian)感是指(zhi)對(dui)電(dian)抗(kang)器(qi)電(dian)抗(kang)值的設置。
激勵變變比(bi)是指對(dui)勵磁變壓(ya)器的變比(bi)設置(zhi)。
設置電(dian)壓(ya)是高壓(ya)試驗時的(de)保(bao)護電(dian)壓(ya)設置。
試驗(yan)電(dian)壓(ya)是高壓(ya)試驗(yan)時的試驗(yan)電(dian)壓(ya)。
加(jia)壓(ya)(ya)時間是施(shi)加(jia)試驗電壓(ya)(ya)的時間。
激(ji)勵(li)強度是(shi)指主(zhu)機電源輸出的大小。
輸出(chu)電(dian)流是主(zhu)機電(dian)源的(de)輸出(chu)電(dian)流。
頻率范圍是試(shi)驗的頻率范圍。
自動試驗模式是指試驗過程全(quan)部自動完成。
自(zi)動調諧模(mo)式是指自(zi)動尋(xun)找諧振點后,手動加壓完成試(shi)驗。
手(shou)動試驗模式全部由人工完成試驗過(guo)程(cheng)。
未接地線主機電源為接地。
不能(neng)諧(xie)振未能(neng)找(zhao)到諧(xie)振點。
輸(shu)出保護主機電(dian)源輸(shu)出電(dian)流大于整定電(dian)流。
試驗中止指在升(sheng)壓或(huo)加壓過程裝置自動保護。
設備出廠(chang)參數設置是廠(chang)家對設備有關(guan)參數的設置。
確(que)認(ren)鍵:確(que)認(ren)當前操作(zuo)。
返回鍵:返回上**菜單。
七、變頻電源技術參數:
1.額(e)定輸出容(rong)量:15kvA;
2.儀器(qi)電(dian)源:220v±10% 50Hz;
功率電源:380v±10% 50Hz;
3.額定(ding)輸(shu)入電流(liu):39.5A;
4.額(e)定輸(shu)出電壓(ya):0-340v可(ke)調(diao)、單相、輸(shu)出電壓(ya)不穩定度0.05%;
5.額(e)定輸出電流(liu):44A;
6.頻率調節范圍:25~320Hz;
7.額定容量下連續運(yun)行為規定工作時間下*高溫升≤60K;
8.顯(xian)示以(yi)下(xia)參(can)數:
a.經變頻(pin)輸出的頻(pin)率(lv)、電(dian)壓、電(dian)流;
b.過壓保護電壓值,并可任(ren)意整定,當成(cheng)套裝置(zhi)的(de)輸出(chu)電壓值達到保護整定時,可自動(dong)切除(chu)成(cheng)套裝置(zhi);
c.過流保護:當調頻電源的輸(shu)出電流達(da)到(dao)保護整定(ding)值時,可(ke)自動(dong)切除成(cheng)套裝置;
d.擊(ji)穿(chuan)保護:當高壓側(ce)發生對地閃絡時,可自動切除(chu)成套裝置,裝置帶有隔離裝置,可確保設備和人身不受損害;
e.具有全(quan)電(dian)壓(ya)輸(shu)出保(bao)護(hu),在調壓(ya)過程中,一旦調壓(ya)失(shi)控,調頻電(dian)源(yuan)立即(ji)閉鎖;
9.可(ke)實現以下操作:
a.頻率(lv)的調(diao)節,上升和下降(jiang)頻率(lv)調(diao)節分粗調(diao)和細調(diao)兩種,并可(ke)自動尋(xun)找試(shi)驗諧(xie)振(zhen)點,保證諧(xie)振(zhen)頻率(lv)在(zai)整個試(shi)驗過(guo)程中(zhong)不發生漂移;
b.帶有設(she)(she)置(zhi)電(dian)壓(ya)(ya)、設(she)(she)置(zhi)時間,電(dian)壓(ya)(ya)自(zi)動(dong)上(shang)升(sheng)到設(she)(she)置(zhi)值而停止并自(zi)動(dong)計時;
c.帶有各種保(bao)護功能的整(zheng)定(ding)按(an)鈕(niu),可在面板(ban)上對各種保(bao)護值進(jin)行整(zheng)定(ding);
d.帶(dai)有手動試(shi)驗(yan)(yan)功(gong)能和自(zi)動試(shi)驗(yan)(yan)功(gong)能;
e.帶有試驗數(shu)據打印(yin)功能。
八、勵(li)磁(ci)變(bian)壓器技術參數:
1.結構形式:干式;
2.額定(ding)容量:15kVA;
3.輸入電壓(ya):0~340V;
4.輸出電(dian)壓:四(si)組并聯3.75KV;四(si)組串聯15KV;二串二并7.5KV;
5.輸出電流:四(si)組并聯(lian)4A;四(si)組串聯(lian)1A;二(er)串二(er)并2A;
6.工作頻率范圍:30~300Hz;
勵磁(ci)變(bian)壓器的接(jie)線端子(zi),如圖(tu)所(suo)示:
1.輸出端尾(wei)—與接地端連接。
2.輸出(chu)端頭—與電(dian)抗器連接(jie)。
3.接(jie)(jie)地(di)端—與變頻電(dian)源、分壓器及(ji)被試品(pin)共同接(jie)(jie)地(di)。
4.輸入端—接調頻電源功(gong)率輸出端。
九、諧振電抗器技(ji)術參數:
額定容量(liang):55KVA;
額定電壓(ya):55kV;
額(e)定電(dian)流:1.5A;
電 感(gan) 量(liang):160H;
品(pin)質(zhi)因(yin)數:Q≥30
采(cai)用環氧干式(shi)。
7.接線端了(le)如圖(tu)所示:
a.高(gao)壓側接線(xian)端(duan)子—與(yu)被試品(pin)高(gao)壓端(duan)連接。
b.低(di)壓側(ce)接線端子(zi)—與勵磁變(bian)輸出端連(lian)接。
c.多臺(tai)(tai)電(dian)抗器串聯時上(shang)節的低壓側與下節高壓側連接。諧振電(dian)抗器采用多臺(tai)(tai)串聯或并聯的連接方式。
8.額定容(rong)量下連續運行為規定工(gong)作時間下,電抗器對空氣的(de)溫升不大于60K;
9.性(xing)能及(ji)特點(dian):電(dian)抗(kang)器設計干式、環(huan)氧澆鑄,電(dian)抗(kang)器可以自由(you)方便(bian)疊裝(zhuang)。環(huan)氧樹脂(zhi)絕緣(yuan)筒外殼(ke),具有足(zu)夠的(de)電(dian)氣、機械(xie)強度,必要的(de)散熱(re)能力以及(ji)油熱(re)脹冷縮的(de)裕度。外殼(ke)上下蓋板,顏色(se)為橘紅色(se)。
十、電容(rong)分壓器技術(shu)參(can)數:
額定(ding)電壓:200kV;
工作頻率:30~300Hz;
分(fen)壓比:2000:1;
分(fen)壓(ya)比誤差:1%;
電容(rong)分壓(ya)器接線端子如圖所示(shi):
高壓(ya)(ya)端—與電(dian)抗器高壓(ya)(ya)側及(ji)被試品高壓(ya)(ya)側相連。
測(ce)量(liang)插座—采(cai)用專配的測(ce)量(liang)電纜(lan)與控制箱(xiang)背板(ban)測(ce)量(liang)輸入(ru)端(duan)連(lian)接。
接(jie)(jie)地端(duan)—采用專配接(jie)(jie)地線(xian)按接(jie)(jie)線(xian)圖指(zhi)示接(jie)(jie)地。
4.性(xing)能及特點:
a.額(e)定電壓下可連續運行2小(xiao)時。
b.在30~300Hz范圍內,其(qi)精度(du)和穩定度(du)保(bao)持不變。
c.在20℃溫度下電容分壓器介質損耗(hao)值≤0.0025
d.電容分壓器配有(you)支撐底架,具(ju)有(you)足夠的穩定(ding)性(xing)。
e.電(dian)壓測(ce)量(liang)通過專(zhuan)用測(ce)試引線引至(zhi)調頻電(dian)源進行測(ce)量(liang)。
試驗接線圖:
110kv主變、GIS試驗接線
35kv電纜試驗接(jie)線圖
10kv電(dian)纜試驗接線(xian)圖
十二、設備保存和維護
1、存放(fang)于干燥、清潔場地(di),防止雨水、灰塵進入部(bu)件(jian)內部(bu);
2、如若(ruo)長期(qi)不(bu)使用,正常天氣至少2個(ge)月(yue)應(ying)通電一次時(shi)間不(bu)少于(yu)半小時(shi),雨季及潮濕期(qi)應(ying)每隔一個(ge)月(yue)通電一次,通電時(shi)間半小時(shi),以(yi)驅除設備(bei)內的潮氣防止電子元器(qi)件的銹蝕,影(ying)響正常使用。
3、定期檢查裝置各部件(jian),確保各接頭緊固無松動;
4、更換(huan)(huan)打(da)(da)印(yin)紙(zhi)(zhi),機(ji)器采用(yong)熱敏(min)打(da)(da)印(yin)紙(zhi)(zhi)并且是前換(huan)(huan)紙(zhi)(zhi)式當需要(yao)換(huan)(huan)紙(zhi)(zhi)時只要(yao)按POST鍵鈕打(da)(da)印(yin)紙(zhi)(zhi)艙門(men)就會(hui)打(da)(da)開可以(yi)將(jiang)新打(da)(da)印(yin)紙(zhi)(zhi)裝入(ru);
十三、常見(jian)故障(zhang)排除
故障現象
|
發 生 原 因
|
排 除 方(fang) 法
|
找不到諧振點
|
接線有誤。
輸出開關未(wei)開,;
3、做GIS時PT二(er)次回路(lu)未打開(kai);
4、試品Q值(zhi)太低;
5、起始(shi)激勵功率太低;
6、試(shi)驗(yan)回路(lu)有短路(lu)現象;
7、找頻(pin)范圍(wei)不對。
|
退出(chu)試驗狀態,合(he)上輸(shu)出(chu)開(kai)關,檢(jian)查接線;打(da)開(kai)PT二次回路;
調高起始功率(∠30%);
用兆歐表(biao)測量試品絕緣(yuan)
重新設置(zhi)找(zhao)頻(pin)范圍
|
諧振后(hou),電壓升不上去
|
1、試品(pin)Q值太低(di);
2、激勵(li)電壓不夠;
3、電抗器底部(bu)有鐵磁物體;
4、3次(ci)諧(xie)波諧(xie)振。
|
檢(jian)查(cha)試品;
改變(bian)激勵變(bian)壓器(qi)繞(rao)組接法,提(ti)高勵磁電壓
絕(jue)緣筒(tong)架高(gao)電抗器或(huo)離開(kai)鐵磁(ci)物體。
|
主機自(zi)動(dong)復位
|
供(gong)電(dian)電(dian)源容量(liang)不(bu)夠(gou);
電源引線(xian)過(guo)長(chang)或(huo)線(xian)徑(jing)過(guo)小;
接(jie)(jie)頭處(chu)接(jie)(jie)觸(chu)**;
供(gong)電電壓波動;
按鍵死接觸。
|
增加供電電源容量;
換較粗導(dao)線,減小導(dao)線長度;
檢查接頭;
減小供(gong)電(dian)電(dian)壓波動。
|
開機后線路跳閘
|
線路漏電保護器較為敏(min)感;
空氣開關容量不夠(gou)。
|
跨過漏電(dian)保護(hu)器或(huo)空(kong)氣(qi)開關的接線;
改(gai)換較大容(rong)量(liang)的(de)空(kong)氣開關。
|
電(dian)壓跌落
|
試品放電或擊穿
|
檢查試品
|
輸出短路
|
電流(liu)超過本機限流(liu)值。
|
檢查(cha)接線(xian)和(he)試品。
|
試品電(dian)壓不準
|
分壓比設置(zhi)錯誤或分壓器信號傳(chuan)輸(shu)有問題。
|
重設分(fen)壓比或檢查分(fen)壓器接(jie)線。
|
電壓閃變
|
試驗電壓劇(ju)烈波動(dong),變化率超過本機限定值。
|
檢查供電(dian)電(dian)源電(dian)壓(ya)穩定(ding)性或試品參(can)數的變化(hua)。
|
回路無電流
|
|
檢查接線和(he)試品。
|
未接好地線
|
|
檢(jian)查接(jie)地線和(he)地樁,按說明書要(yao)求連接(jie)。
|
試品(pin)過電壓
|
手(shou)動升(sheng)壓(ya)太快(kuai)或失控。
|
改(gai)變(bian)調壓步距(ju)或改(gai)用(yong)自(zi)動升壓 。
|
系統不諧振
|
接(jie)線有誤或(huo)試品Q值太低(di)。
|
檢(jian)查接線(xian)和試品
|
十四、常用設(she)備資(zi)料參考
交聯聚(ju)乙烯電(dian)纜單位長(chang)度電(dian)容量
電纜導體截面積(平方毫米)
|
電(dian) 容 (μ/km)
|
YJV、YJLV
|
YJV、YJLV
|
YJV、YJV、YJLV
|
YJV、YJLV
|
YJV、YJLV
|
6/6kV、6/10kV
|
8.7/10kV、8.7/15kV
|
12/35kV
|
21/35kV
|
26/35kV
|
1×35
|
0.212
|
0.173
|
0.152
|
|
|
1×50
|
0.237
|
0.192
|
0.166
|
0.118
|
0.114
|
1×70
|
0.270
|
0.217
|
0.187
|
0.131
|
0.125
|
1×95
|
0.301
|
0.240
|
0.206
|
0.143
|
0.135
|
1×120
|
0.327
|
0.261
|
0.223
|
0.153
|
0.143
|
1×150
|
0.358
|
0.284
|
0.241
|
0.164
|
0.153
|
1×185
|
0.388
|
0.307
|
0.267
|
0.180
|
0.163
|
1×240
|
0.430
|
0.339
|
0.291
|
0.194
|
0.176
|
1×300
|
0.472
|
0.370
|
0.319
|
0.211
|
0.190
|
1×400
|
0.531
|
0.418
|
0.352
|
0.231
|
0.209
|
1×500
|
0.603
|
0.438
|
0.388
|
0.254
|
0.232
|
1×600
|
0.667
|
0.470
|
0.416
|
0.287
|
0.256
|
2、交聯(lian)聚乙(yi)烯電(dian)纜單(dan)位長度電(dian)容量
電纜導(dao)體截面積(平方毫米)
|
電 容(rong) (μF/km)
|
YJV、YJLV
|
YJV、YJLV
|
YJV、YJV、YJLV
|
YJV、YJLV
|
YJV、YJLV
|
6/6kV、6/10kV
|
8.7/10kV、8.7/15kV
|
12/35kV
|
21/35kV
|
26/35kV
|
3×35
|
0.212
|
0.173
|
0.152
|
|
|
3×50
|
0.237
|
0.192
|
0.166
|
0.118
|
0.114
|
3×70
|
0.270
|
0.217
|
0.187
|
0.131
|
0.125
|
3×95
|
0.301
|
0.240
|
0.206
|
0.143
|
0.135
|
3×120
|
0.327
|
0.261
|
0.223
|
0.153
|
0.143
|
3×150
|
0.358
|
0.284
|
0.241
|
0.164
|
0.153
|
3×185
|
0.388
|
0.307
|
0.267
|
0.180
|
0.163
|
3×240
|
0.430
|
0.339
|
0.291
|
0.194
|
0.176
|
3×300
|
0.472
|
0.370
|
0.319
|
0.211
|
0.190
|
3×400
|
0.531
|
0.418
|
0.352
|
0.231
|
0.209
|
3×500
|
0.603
|
0.438
|
0.388
|
0.254
|
0.232
|
3×600
|
0.667
|
0.470
|
0.416
|
0.287
|
0.256
|
3、交聯聚乙烯(xi)電纜單位長度電容量
電纜(lan)導體截面積(平方毫米)
|
電 容 (μF/km)
|
YJV、YJLV
|
YJV、YJLV
|
64/110kV
|
128/220kV
|
3×240
|
0.129
|
|
3×300
|
0.139
|
|
3×400
|
0.156
|
0.118
|
3×500
|
0.169
|
0.124
|
3×630
|
0.188
|
0.138
|
3×800
|
0.214
|
0.155
|
3×1000
|
0.231
|
0.172
|
3×1200
|
0.242
|
0.179
|
3×1400
|
0.259
|
0.190
|
3×1600
|
0.273
|
0.198
|
3×1800
|
0.284
|
0.297
|
3×2000
|
0.296
|
0.215
|
3×2200
|
|
0.221
|
3×2500
|
|
0.232
|
4、60kV級全絕緣變壓(ya)器(qi)的電容(pF)
類 型
|
變 壓 器 容 量 kVA
|
630
|
2000
|
3150
|
6300
|
8000
|
1600
|
高壓(ya)-地
|
2700
|
4100
|
4600
|
5900
|
7000
|
8200
|
低壓-地
|
4200
|
6600
|
7900
|
10000
|
11000
|
15300
|
對(dui)于表(biao)(biao)中沒有(you)的(de)產品,可(ke)根據表(biao)(biao)中的(de)上(shang)、下容量近似(si)地估算。同容量的(de)雙(shuang)繞(rao)組變(bian)壓(ya)器,其(qi)繞(rao)組電容要比三繞(rao)組產品小。
5、110kV級中性點(dian)分級絕緣變壓器(qi)的電容(pF)
類 型(xing)
|
變 壓 器 容 量(liang)kVA
|
50000
|
31500
|
20000
|
10000
|
5600
|
高壓(ya)-中壓(ya)、低壓(ya)、地
|
14200
|
11400
|
8700
|
6150
|
4200
|
中壓-高壓、低壓、地
|
24800
|
11800
|
13200
|
9600
|
-
|
低(di)壓-高壓、中壓、地(di)
|
19300
|
19300
|
12000
|
9400
|
6800
|
6、220kV級(ji)中性點非全級(ji)絕緣(yuan)部分變壓器的電容(pF)
試 品 型 號
|
SEPSL-63000
|
SSPSL-120000
|
SSPSL-240000
|
類 型
|
高壓-中壓、低壓及地
|
12100
|
13500
|
17050
|
中(zhong)壓(ya)(ya)-高壓(ya)(ya)、低壓(ya)(ya)及地
|
18500
|
19700
|
23260
|
低(di)壓-高(gao)壓、中壓及(ji)地
|
18200
|
23600
|
29940
|
試 品 型 號
|
SFPL-240000
|
SFP-360000
|
SFPSZL-120000
|
類 型
|
高壓(ya)-中(zhong)壓(ya)、低壓(ya)及(ji)地(di)
|
32230
|
33910
|
38020
|
中壓-高壓、低壓及地
|
-
|
-
|
23260
|
低壓(ya)-高壓(ya)、中(zhong)壓(ya)及地
|
22470
|
23790
|
22160
|
7、油(you)浸式(shi)電(dian)力變壓器交流試(shi)驗電(dian)壓
額定電壓
(k V)
|
*高工作(zuo)
電壓(k V)
|
線(xian)端交流試驗(yan)電壓值(kV)
|
中性點交流試驗電壓值(kV)
|
全(quan)部更換繞(rao)組(zu)
|
部分更換繞組或交接
|
全(quan)部更(geng)換繞組
|
部分更換繞組或(huo)交接(jie)
|
<1
|
≤1
|
3
|
2.5
|
3
|
2.5
|
3
|
3.5
|
18
|
15
|
18
|
15
|
6
|
6.9
|
25
|
21
|
25
|
21
|
10
|
11.5
|
35
|
30
|
35
|
30
|
15
|
17.5
|
45
|
38
|
45
|
38
|
20
|
23.0
|
55
|
47
|
55
|
47
|
35
|
40.5
|
85
|
72
|
85
|
72
|
110
|
126.0
|
200
|
170(195)
|
95
|
80
|
220
|
252.0
|
360
|
306
|
85
|
72
|
395
|
336
|
(200)
|
(170)
|
500
|
550.0
|
630
|
536
|
85
|
72
|
680
|
578
|
140
|
120
|
8、部分(fen)型號(hao)發電(dian)機定(ding)子繞組(zu)的單相對地電(dian)容量
類(lei)別(bie)
|
發 電 機
|
型號
|
生(sheng)產廠家(jia)
|
額定容量(MW)
|
額定(ding)電壓(ya)(kV)
|
相電容(mF)
|
火(huo)
力
發
電
機
|
QFS-125-2
|
上海電機(ji)廠(chang)
|
125
|
13.8
|
0.08-0.12
|
QFSN-200-2
|
哈爾濱電機廠
|
200
|
15.75
|
0.19-0.21
|
QFQS-200-2
|
東方電機廠
|
200
|
15.75
|
0.1928-0.21
|
QFQS-200-2
|
北京(jing)重型(xing)電(dian)機廠
|
200
|
15.75
|
0.18-0.19
|
QFS-300-2
|
上(shang)海電機(ji)廠
|
300
|
18.0
|
0.16-0.20
|
QFSN-300-2
|
上(shang)海電機(ji)廠
|
300
|
18.0
|
0.18-0.20
|
ATB-2
|
美國GE公(gong)司
|
352
|
23.0
|
0.268(設計(ji)值)
|
TBB-320-2
|
(前蘇聯)
|
320
|
20.0
|
0.31
|
2-105×234
|
美(mei)國西屋公司
|
600
|
20.0
|
0.2(工廠試(shi)驗值)
|
50WT23E-138
|
ABB
|
600
|
22.0
|
0.253(設計(ji)值(zhi))
|
水 發
力(li) 電
機
|
|
|
72.5 - 85
|
10.5
|
0.694
|
|
|
300
|
15.75
|
1.7-2.5
|
|
|
400
|
18.0
|
2-2.5
|
9、同(tong)步發電機定(ding)子繞(rao)組交(jiao)流試驗電壓
1
|
全部更換(huan)定子繞組并修好后的(de)試驗電壓
|
容量kW或kVA
|
小于10000
|
10000及以上
|
額(e)定電壓Un (V)
|
36以(yi)上
|
6000以(yi)下
|
6000~18000
|
18000以上(shang)
|
試驗電壓V
|
2Un+1000但*低(di)為1500
|
2.5Un
|
2Un
+3000
|
按專(zhuan)門協議(yi)
|
2
|
大(da)修前或局(ju)部更換(huan)定子繞組并修好后的試驗電壓
|
運(yun)行20年及以(yi)下者
|
1.5 Un
|
運行20年以(yi)上與架空線路直(zhi)接(jie)(jie)連接(jie)(jie)者
|
1.5 Un
|
運行20年以上不與架空(kong)線路直接連接者
|
(1.3~1.5)Un
|
十五、設備(bei)成套性:
變頻電源 1臺
勵磁(ci)變壓器 1臺
電抗器 4臺
電容分壓(ya)器 1臺
附件及測試線 1套
支架 15KV 1只
均壓(ya)罩 200KV 2只
絕緣底板(ban) 2塊
一、產品概述
YDQC系列(lie)輕(qing)型交直(zhi)流(liu)高(gao)壓(ya)試(shi)驗(yan)變壓(ya)器(qi)是在同類產品(pin)(pin)YDJ(G)型高(gao)壓(ya)試(shi)驗(yan)變壓(ya)器(qi)的基礎上,按試(shi)驗(yan)變壓(ya)器(qi)國家標準ZBK41006—89要(yao)求(qiu),經改進后生(sheng)產的一(yi)種(zhong)新(xin)型產品(pin)(pin),本系列(lie)產品(pin)(pin)具有體積小、重(zhong)量輕(qing)、結構緊湊、功能齊全、使用方便等(deng)(deng)特點。實用于電力、工(gong)礦、科(ke)研(yan)等(deng)(deng)部門,對(dui)各種(zhong)高(gao)壓(ya)電氣(qi)設(she)備、電氣(qi)元件、絕緣材料進行工(gong)頻耐壓(ya)試(shi)驗(yan)和直(zhi)流(liu)泄(xie)漏試(shi)驗(yan),是高(gao)壓(ya)試(shi)驗(yan)中必不可(ke)少的儀器(qi)。
二、產品結構
YDQC系(xi)列輕(qing)型高壓(ya)試驗變壓(ya)器(qi)鐵芯為單框式。線圈采用同(tong)芯圓筒多層塔式結(jie)構,初級低壓(ya)繞(rao)(rao)組繞(rao)(rao)在鐵芯上,次級高壓(ya)繞(rao)(rao)組繞(rao)(rao)在低壓(ya)繞(rao)(rao)組外側,這(zhe)種同(tong)軸布(bu)置減少了繞(rao)(rao)組間的(de)藕(ou)合(he)損耗。高壓(ya)硅堆用特殊(shu)工藝封(feng)裝(zhuang)在套管(guan)內,產(chan)品的(de)外殼(ke)制(zhi)成與(yu)器(qi)芯配(pei)合(he)較(jiao)佳的(de)八角形結(jie)構,整體外型美觀(guan)大方。其(qi)內外部結(jie)構見圖1。
1-均壓(ya)球;2-硅堆短路(lu)桿;3-高(gao)壓(ya)套(tao)管;4-油閥;5-殼(ke)體;6、7-調整電壓(ya)輸入a、x端子;8、9-儀表測量(liang)(liang)E、F端子;10-高(gao)壓(ya)尾X端子;11-變壓(ya)器(qi)外殼(ke)接地(di)端;12-高(gao)壓(ya)輸出A端子;13-高(gao)壓(ya)整流(liu)硅堆;14-內部均壓(ya)環;15-變壓(ya)器(qi)鐵芯;16-初級低壓(ya)繞組;17-測量(liang)(liang)儀表繞組;18-二次級高(gao)壓(ya)繞組;19-變壓(ya)器(qi)油。
三、工作原理
YDQC系列輕型(xing)高(gao)(gao)(gao)壓(ya)(ya)(ya)試驗(yan)變(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)器(qi)為單相變(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)器(qi),聯結組標號II。單臺高(gao)(gao)(gao)壓(ya)(ya)(ya)試驗(yan)變(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)器(qi)的工作(zuo)過程,用交流220V(10KVA以上(shang)為380V)電(dian)(dian)(dian)壓(ya)(ya)(ya)接(jie)入(ru)電(dian)(dian)(dian)源(yuan)控制箱(xiang)(臺),經電(dian)(dian)(dian)源(yuan)控制箱(xiang)(臺)內(nei)自(zi)藕調壓(ya)(ya)(ya)器(qi)(50KVA以上(shang)調壓(ya)(ya)(ya)器(qi)外附(fu))調節0~200V(10KVA以上(shang)0~400V)電(dian)(dian)(dian)壓(ya)(ya)(ya)至試驗(yan)變(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)器(qi)的初級繞(rao)組,根據電(dian)(dian)(dian)磁感應原理,在試驗(yan)變(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)器(qi)高(gao)(gao)(gao)壓(ya)(ya)(ya)繞(rao)組可獲得試驗(yan)所需的高(gao)(gao)(gao)電(dian)(dian)(dian)壓(ya)(ya)(ya)。其(qi)工作(zuo)原理圖見(jian)圖2所示。
1、單臺YDQC高壓(ya)試驗變壓(ya)器工作原理示(shi)意圖
在試驗(yan)變(bian)壓器中:a、x為低壓輸(shu)入端;A、X 為高壓輸(shu)出端;E、F為儀(yi)表測量(liang)端。
2、單臺交直流兩用型高壓試驗變壓器工作原理見圖3。圖中所示:高壓套管內裝有高壓硅堆,串接在高壓回路中作高壓整流,以獲得直流高電壓。當用一短路桿將高壓硅堆短接時,可獲得交流高電壓,其狀態為交流輸出;反之在抽出短路桿時,其狀態為直流輸出。
3、三臺高壓試驗變壓器串激獲得更高電壓原理見圖4,串激高壓試驗變壓器有很大的優越性,因為整個試驗裝置由多個單臺串激式試驗變壓器組成,單臺試驗變壓器有著體積小、重量輕、便于運輸的特點,它既可以串接成高出幾倍的單臺試驗變壓器輸出電壓組合使用,又可以分開單獨使用。整套試驗裝置投資小、經濟實惠。圖3所示:在三臺串激式試驗變壓器串激使用中,單臺試驗變壓器B1、B2、B3的輸出電壓都是U,**、二級的試驗變壓器內部都有一個激磁繞組,分別為A1、C1 和A2、C2。當控制電壓加在第**試驗變壓器B1的初級繞組a1、x1上,激磁繞組A1、C1給予試驗變壓器B2初級繞組供電,**級試驗變壓器B2的激磁繞組A2、C2給試驗變壓器B3的初級繞組供電。由于第**試驗變壓器B1的高壓尾及殼體接地,**、三級的試驗變壓器B2和B3對地有絕緣支架的隔離,這樣試驗變壓器B1、B2、B3對地輸出電壓分別為1U、2U、3U。
B1、B2、B3- 串(chuan)激式(shi)高壓(ya)(ya)變(bian)壓(ya)(ya)器;1U、2U、3U-各級對地電(dian)壓(ya)(ya);
PV- 高(gao)壓(ya)示值表(KV); ZJ1、ZJ2-絕緣(yuan)支架。
四、使用(yong)方(fang)法及(ji)注意事項
1、YDQC高壓(ya)(ya)試(shi)驗變(bian)壓(ya)(ya)器(qi)做工(gong)頻耐壓(ya)(ya)試(shi)驗使用接線(xian)方法見(jian)圖(tu)5。做工(gong)頻耐壓(ya)(ya)試(shi)驗前,先(xian)根據(ju)試(shi)驗變(bian)壓(ya)(ya)器(qi)的(de)額定容量選擇(ze)好限流電(dian)阻(zu)(zu),(水(shui)電(dian)阻(zu)(zu))的(de)阻(zu)(zu)值(zhi),再(zai)根據(ju)被試(shi)品(pin)需加(jia)的(de)高壓(ya)(ya)電(dian)壓(ya)(ya)值(zhi)調整好放(fang)電(dian)球(qiu)隙的(de)球(qiu)間距,為(wei)了提高對(dui)被試(shi)品(pin)施(shi)加(jia)電(dian)壓(ya)(ya)的(de)測量精(jing)度,應在(zai)高壓(ya)(ya)側接入FRC阻(zu)(zu)容分壓(ya)(ya)器(qi)來(lai)測量電(dian)壓(ya)(ya)。
R1、R2- 限(xian)流電阻; Qx- 放(fang)電球隙; Zx- 被試品;
FRC- 阻容分壓器; V- 分壓器高壓表。
按照圖4、結合圖2所進行的工頻耐壓試驗接好工作線路,試驗變壓器的高壓繞阻的X端(高壓尾)、儀表測量繞組的F端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
用三臺試驗變壓器串激做工頻耐壓試驗時、**、三級試驗變壓器的初級繞組X端,儀表測量繞組的F端,以及高壓繞組的X端(高壓尾)均接本級試驗變壓器的外殼,**、三級試驗變壓器的主體必須放置在絕緣支架上。除第**以外、**、三級試驗變壓器的主體不要接地線。其接線方式見圖3所示。
接電源前,電源控制箱(臺)的調壓器必須調到零位。接通電源后,綠色指示燈亮,按一下啟動按鈕,紅色指示燈亮,表示試驗變壓器已接通控制電源,開始升壓。
從零位開始按順時針方向勻速旋轉調壓器手輪升壓。(升壓方式有:快速升壓法,即20S逐級升壓法,慢速升壓法,即60S逐級升壓法,極慢速升壓法供選用)電壓從零開始按選定的升壓速度升到您所需額定試驗電壓的75%后,再以每秒2%額定試驗電壓的速度升到您所需試驗電壓,并密切注意測量儀表的指示以及被試品的情況,被試品施加電壓的時間到后。應在數秒內勻速將調壓器返回,高壓降至1/3試驗電壓以下,按一下停止按鈕,高壓、低壓輸出停止,然后切斷電源線,試驗完畢。
工(gong)頻(pin)耐壓試驗操作過程(cheng)注意(yi)事(shi)項
1、試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
2、被試品主要部位應**干凈,保持**干燥,以免損壞被試品和帶來試驗數值的誤差。
3、對大型設備的試驗,一般都應先進行試驗變壓器的空升試驗,即不接試品時升壓至試驗電壓,以便校對好儀表的指示精度,調整好放電球隙的球間距。
4、做耐壓試驗時升壓速度不能過快,并防止突然加壓,例如調壓器不在零位的突然合閘,也不能突然斷電,一般應在調壓器降至零位時分閘。
5、在升壓或耐壓試驗過程中,如發現下列不正常情況,1 電壓、電流表指針擺動很大,2 被試品發出不正常響聲,3 發現絕緣有燒焦或冒煙現象,應立即降壓,切斷電源,停止試驗并查明原因。
6、使用本產品做高壓試驗時,除熟悉本說明書外,還必須嚴格執行國家有關標準和操作規程。
2、YDQ交(jiao)直流(liu)(liu)兩用高(gao)壓(ya)(ya)(ya)(ya)試(shi)(shi)驗變(bian)壓(ya)(ya)(ya)(ya)器(qi)做(zuo)直流(liu)(liu)耐壓(ya)(ya)(ya)(ya)和泄漏(lou)(lou)試(shi)(shi)驗使用接線方法見圖5。由(you)于是交(jiao)直流(liu)(liu)兩用高(gao)壓(ya)(ya)(ya)(ya)試(shi)(shi)驗變(bian)壓(ya)(ya)(ya)(ya)器(qi),應(ying)把高(gao)壓(ya)(ya)(ya)(ya)硅堆短路桿從套管中抽出(chu),使試(shi)(shi)驗變(bian)壓(ya)(ya)(ya)(ya)器(qi)為(wei)直流(liu)(liu)輸(shu)出(chu)狀態。做(zuo)直流(liu)(liu)泄漏(lou)(lou)試(shi)(shi)驗前,先根據泄漏(lou)(lou)試(shi)(shi)驗中輸(shu)出(chu)端斷路電(dian)流(liu)(liu)不超過高(gao)壓(ya)(ya)(ya)(ya)硅堆的(de)*大(da)整流(liu)(liu)為(wei)宜,選擇(ze)(ze)好限流(liu)(liu)電(dian)阻(zu)(水電(dian)阻(zu))的(de)阻(zu)值,再根據被試(shi)(shi)品(pin)對直流(liu)(liu)高(gao)壓(ya)(ya)(ya)(ya)波形的(de)要求選擇(ze)(ze)好高(gao)壓(ya)(ya)(ya)(ya)濾波電(dian)容的(de)電(dian)容值。為(wei)了提高(gao)對被試(shi)(shi)品(pin)施加電(dian)壓(ya)(ya)(ya)(ya)的(de)測量精度,應(ying)在高(gao)壓(ya)(ya)(ya)(ya)側接入FRC阻(zu)容分壓(ya)(ya)(ya)(ya)器(qi)來測量電(dian)壓(ya)(ya)(ya)(ya)。
R- 限流電阻; C- 高壓濾(lv)波電容; Zx- 被試品(pin); G- 硅堆短(duan)路桿;
FRC- 阻容分壓器;V- 分壓器高壓表;uA- 微安表;D- 高壓整流硅堆。
按照圖5、結合圖3所進行的直流泄漏試驗接好工作線路。試驗變壓器的高壓繞組的X端(高壓尾)、儀表測量繞組的F 端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
接電源前、電源控(kong)制箱(臺)的調壓器必須(xu)調到零位。接通電源后,綠色指(zhi)(zhi)示燈亮,按一下(xia)啟動按鈕(niu),紅色指(zhi)(zhi)示燈亮,表示試驗變壓器已接通控(kong)制電源,開始升(sheng)壓。
從(cong)零(ling)位開始按(an)順時針方向(xiang)勻速(su)旋轉調壓(ya)(ya)器(qi)手輪(lun)升(sheng)壓(ya)(ya)。(升(sheng)壓(ya)(ya)方式(shi)有:快速(su)升(sheng)壓(ya)(ya)法即(ji)20S逐級(ji)升(sheng)壓(ya)(ya)法;慢(man)速(su)升(sheng)壓(ya)(ya)法,即(ji)60S逐級(ji)升(sheng)壓(ya)(ya)法;級(ji)慢(man)速(su)升(sheng)壓(ya)(ya)法供選用)電壓(ya)(ya)從(cong)零(ling)開始按(an)選定的(de)升(sheng)壓(ya)(ya)速(su)度升(sheng)到您所(suo)需額定試(shi)(shi)驗電壓(ya)(ya)或額定直流(liu)(liu)電流(liu)(liu)下(xia)的(de)參(can)考電壓(ya)(ya)。試(shi)(shi)驗中(zhong)應嚴密注意直流(liu)(liu)高(gao)壓(ya)(ya)表(biao)、泄漏(lou)電流(liu)(liu)表(biao)指示以(yi)及被(bei)試(shi)(shi)品的(de)情況(kuang)。試(shi)(shi)驗完畢后(hou),應訊(xun)速(su)均勻將高(gao)壓(ya)(ya)降至零(ling)位,按(an)一(yi)下(xia)停(ting)止按(an)鈕,高(gao)壓(ya)(ya)、低壓(ya)(ya)輸出停(ting)止,然后(hou)切斷電源(yuan)。此時應用直流(liu)(liu)高(gao)壓(ya)(ya)放**給被(bei)試(shi)(shi)品及試(shi)(shi)驗裝置本身充分放電。
直流泄漏(lou)試驗操作過程注意事項(xiang)
(1)試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
(2)被試品做試驗前,應拆除所有對外連線,并充分放電,主要部位應**干凈,保持**干燥,以免損壞被試品及帶來試驗數值的誤差。
(3)對于大容量試品(電容器、超長電纜等)試驗時應緩慢升壓,防止被試品的充電電流過大而燒壞微安表,必要時應分級加壓分別讀取各電壓下微安表的穩定讀數。
(4)試驗過程中,應嚴密監視被試品、微安表及試驗裝置等,一旦發生閃爍、擊穿等現象應立即降壓,切斷電源,并查明原因。
五(wu)、配套選購產品(pin)
下列產品僅供選擇,購買時需另行計價。
1.KZX系列電源控制箱 容量:1KVA-5KVA、輸入電壓:220V
2.KZT系列電源控制臺 容量:10KVA~300KVA輸入電壓:220V或380V
3.數字微安表:SWB-II
4.高壓濾波電容: 0.01MF、40 ~ 100KV
5.高壓直流放**: FBR— 70、140、210KV
6.放電球隙: Q—50、100、150、200、250、500
7.標準試油杯: 400ml
8.折疊式手推車: 150、300型
9.絕緣支架: 50、100、200、300、400KV
10.阻容分壓器: FRC —50、100、150、200KV
11.高壓硅堆: 2DL—150、300、450KV
12.水 電 阻: 50、100
六、主要試驗設備的選擇
1、試驗變壓器
其高壓側額定電壓應不小于被試品的*高試驗電壓,額定電流不小于被試品的*大電容電流。被試品的電容電流和試驗變壓器所需容量計算式為:
被試(shi)品電容量Cx可由交流電橋(qiao)測出。常(chang)用的被試(shi)品電容量按表(biao)1選取。
幾種常用被試(shi)品的電容量(pF) 表1
2、調壓(ya)設備
(1)自藕調壓器。其調壓范圍廣、功率損耗小、波形畸變小、選擇這種調壓方式為*好。自藕調壓器的容量按0.75 ~ 1倍的試驗變壓器的容量選擇,適用于容量為100KVA以下的試驗變壓器的調壓。
(2)感應調壓器。其調壓范圍大,波形畸形小、但結構復雜、價格較貴,當試驗變壓器的容量較大時(如100KVA以上)使用。
3、限流電阻
限流電阻的作用是,當被試品擊穿時,限制斷路電流,從而保護試驗變壓器,防止故障的擴大。其數值以*高試驗電壓為準,按0.5 ~ 1 Ω / V(有效值)選擇,限流電阻可用水電阻。注意水不能充滿玻璃管,應留有余地,以防爆裂。
4、放電球隙
放電球隙的布置方式有垂直和水平兩種,球隙間距S和球的直徑D的關系應保護在0.05D ≤S ≤0.5D范圍內,球隙上的水電阻阻值一般按0.1 ~ 1Ω/V選取,設置放電球隙的目的是為了對重要的被試品起保護作用,可以將由于誤操作或被試品擊穿引起的過電壓限制在允許的范圍內。
七、試驗變壓器技(ji)術指示
型(xing)號
|
容量
|
高壓電壓
|
高壓電流
|
低(di)壓輸(shu)入
|
變比(bi)
|
溫升℃
|
(KVA)
|
(KV)
|
(mA)
|
電壓(V)
|
電流(liu)(A)
|
高/儀
|
30分鐘
|
YDQC-1.5/50
|
1.5
|
50
|
30
|
200
|
7.5
|
500
|
10
|
YDQC-3/50
|
3
|
50
|
60
|
200
|
15
|
500
|
10
|
YDQC-5/50
|
5
|
50
|
100
|
200
|
25
|
500
|
10
|
YDQC-10/50
|
10
|
50
|
200
|
200
|
50
|
500
|
10
|
YDQC-15/50
|
15
|
50
|
300
|
200
|
75
|
500
|
10
|
YDQC-20/50
|
20
|
50
|
400
|
380
|
53
|
500
|
10
|
YDQC-30/50
|
30
|
50
|
600
|
380
|
79
|
500
|
10
|
YDQC-50/50
|
50
|
50
|
1000
|
380
|
12
|
500
|
10
|
YDQC-5/100
|
5
|
100
|
50
|
200
|
25
|
1000
|
10
|
YDQC-10/100
|
10
|
100
|
100
|
200
|
50
|
1000
|
10
|
YDQC-20/100
|
20
|
100
|
200
|
400
|
50
|
1000
|
10
|
YDQC-30/100
|
30
|
100
|
300
|
400
|
75
|
1000
|
10
|
YDQC-50/100
|
50
|
100
|
500
|
400
|
125
|
1000
|
10
|
YDQC-20/150
|
20
|
150
|
133
|
400
|
50
|
1500
|
10
|
YDQC-30/150
|
30
|
150
|
200
|
400
|
75
|
1500
|
10
|
YDQC-50/150
|
50
|
150
|
333
|
400
|
125
|
1500
|
10
|
YDQC-100/150
|
100
|
150
|
667
|
400
|
250
|
1500
|
10
|
YDQC-50/200
|
50
|
200
|
250
|
400
|
125
|
2000
|
10
|
YDQC-100/200
|
100
|
200
|
500
|
400
|
250
|
2000
|
10
|
YDQC-150/200
|
150
|
200
|
750
|
400
|
375
|
2000
|
10
|
YDQC-200/200
|
200
|
200
|
1000
|
400
|
500
|
2000
|
10
|
YDQC-300/200
|
300
|
200
|
1500
|
400
|
600
|
2000
|
10
|
YDQC-50/300
|
50
|
300
|
170
|
400
|
125
|
3000
|
10
|
YDQC-100/300
|
100
|
300
|
333
|
400
|
250
|
3000
|
10
|
YDQC-150/300
|
150
|
300
|
500
|
400
|
375
|
3000
|
10
|
YDQC-200/300
|
200
|
300
|
667
|
400
|
500
|
3000
|
10
|
YDQC-300/300
|
300
|
300
|
3000
|
500
|
600
|
3000
|
10
|
1、使用環境條件
環境溫度不高于+40℃、不低于—20℃;空氣相對濕度不大于90%;海拔高度不超過2000米;
2、工作電壓
電源控制箱(臺)輸入電壓為工頻220V或380V、相對誤差不超過±10%;(具體使用電壓根據用戶所定試驗變壓器規格選取)
八、隨貨文件
YDQC 系列試驗變壓器產品說明書 1份
產品出廠試驗報告 1份
產品合格證 1份
裝箱單 1份
一、概述
YDQ系(xi)列高壓(ya)(ya)(ya)(ya)試(shi)驗(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器是(shi)根(gen)據《試(shi)驗(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器》標(biao)準(zhun),在(zai)油(you)(you)浸(jin)式(shi)試(shi)驗(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器的基礎上而(er)設(she)計生產(chan)的。SF6氣(qi)(qi)體(ti)具(ju)有良好的電(dian)(dian)氣(qi)(qi)絕緣(yuan)性(xing)能及優異的滅弧性(xing)能,其耐壓(ya)(ya)(ya)(ya)強(qiang)(qiang)度為同一壓(ya)(ya)(ya)(ya)力(li)下(xia)氮氣(qi)(qi)的2.5倍,擊穿(chuan)電(dian)(dian)壓(ya)(ya)(ya)(ya)的空氣(qi)(qi)的2.5倍。在(zai)0.25MPa下(xia)與油(you)(you)的擊穿(chuan)電(dian)(dian)壓(ya)(ya)(ya)(ya)相等,在(zai)0.45MPa壓(ya)(ya)(ya)(ya)力(li)下(xia)是(shi)油(you)(you)的擊穿(chuan)電(dian)(dian)壓(ya)(ya)(ya)(ya)的2倍,是(shi)一種(zhong)優于油(you)(you)的新一代(dai)超高壓(ya)(ya)(ya)(ya)絕緣(yuan)介(jie)質(zhi)材(cai)料。該(gai)產(chan)品(pin)技術要求完(wan)全符(fu)合《ZBK-41006-89》標(biao)準(zhun),它是(shi)油(you)(you)浸(jin)式(shi)輕型試(shi)驗(yan)變(bian)(bian)壓(ya)(ya)(ya)(ya)器的換(huan)代(dai)產(chan)品(pin)。該(gai)產(chan)品(pin)具(ju)有體(ti)積小(xiao)、重(zhong)量輕、不(bu)受氣(qi)(qi)候(hou)變(bian)(bian)化影響(xiang)、電(dian)(dian)暈小(xiao)、現場搬運無需靜止可(ke)使(shi)用,使(shi)用壽命長、免維修等特(te)點。適用于電(dian)(dian)力(li)系(xi)統、工礦(kuang)企(qi)業、科研(yan)部(bu)門等對各種(zhong)高壓(ya)(ya)(ya)(ya)電(dian)(dian)氣(qi)(qi)設(she)備、電(dian)(dian)氣(qi)(qi)元件、絕緣(yuan)材(cai)料進行(xing)工頻或(huo)直流高壓(ya)(ya)(ya)(ya)下(xia)的絕緣(yuan)強(qiang)(qiang)度試(shi)驗(yan)。
二(er)、產品結(jie)構
YDQ系列(lie)高壓試驗變壓器采(cai)用單(dan)框(kuang)芯(xin)(xin)式鐵(tie)芯(xin)(xin)結(jie)構(gou),初級繞組繞在鐵(tie)芯(xin)(xin)上,高壓繞組在外,這種同(tong)軸布置(zhi)減少(shao)了漏磁通,因而增大了繞組間(jian)的(de)耦合(he)。產品的(de)外殼為圓柱灌式容(rong)器結(jie)構(gou),能耐(nai)受0.8MPa以(yi)上壓力。其結(jie)構(gou)見圖(tu)1:
三、工作原理
YDQ系(xi)列高(gao)(gao)壓(ya)試(shi)驗變(bian)壓(ya)器(qi)為單相(xiang)變(bian)壓(ya)器(qi),聯結組(zu)標號Ⅰ.Ⅰ. 用工頻220V(10kVA以上為380V)電(dian)(dian)(dian)源接(jie)入(ru) (為本公司生產的試(shi)驗變(bian)壓(ya)器(qi)配套專用設備(bei),詳細資料(liao)請見其具(ju)體使用說明(ming)書(shu))系(xi)列操作箱(xiang)(臺),經操作箱(xiang)內自偶調壓(ya)器(qi)(50kVA以上調壓(ya)器(qi)外(wai)附)調節至0~200V(或0~400V)電(dian)(dian)(dian)壓(ya)輸(shu)出至YDQ試(shi)驗變(bian)壓(ya)器(qi)的初級繞(rao)組(zu),根據電(dian)(dian)(dian)磁(ci)感應原理(li),在試(shi)驗變(bian)壓(ya)器(qi)高(gao)(gao)壓(ya)繞(rao)組(zu)可(ke)獲得試(shi)驗所(suo)需(xu)的高(gao)(gao)電(dian)(dian)(dian)壓(ya)。
單臺YDQ系列交直(zhi)(zhi)流(liu)高(gao)(gao)(gao)壓(ya)(ya)(ya)試驗變(bian)壓(ya)(ya)(ya)器的工作原理圖見圖3,圖中(zhong)高(gao)(gao)(gao)壓(ya)(ya)(ya)套管中(zhong)裝(zhuang)有高(gao)(gao)(gao)壓(ya)(ya)(ya)硅(gui)(gui)堆(dui),串接(jie)(jie)在(zai)高(gao)(gao)(gao)壓(ya)(ya)(ya)回路(lu)中(zhong)作半波整(zheng)流(liu),以獲(huo)得直(zhi)(zhi)流(liu)高(gao)(gao)(gao)電壓(ya)(ya)(ya)。當用一(yi)短(duan)路(lu)桿將高(gao)(gao)(gao)壓(ya)(ya)(ya)硅(gui)(gui)堆(dui)短(duan)接(jie)(jie)時(shi),可獲(huo)得工頻高(gao)(gao)(gao)電壓(ya)(ya)(ya),作為交流(liu)輸出(chu)狀態;取消短(duan)路(lu)桿時(shi),作為直(zhi)(zhi)流(liu)輸出(chu)狀態。
圖(tu)中(zhong):D—短路桿 VD—高(gao)壓硅堆
試驗(yan)變壓器高壓套管中的(de)高壓硅堆未畫出,其原理與上圖相(xiang)同。
三(san)(san)臺(tai)(tai)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)串級(ji)(ji)(ji)(ji)(ji)(ji)獲得更高電壓(ya)(ya)(ya)(ya)(ya)(ya)的(de)(de)(de)(de)(de)接線原理(li)見圖4。串級(ji)(ji)(ji)(ji)(ji)(ji)高壓(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)有很大的(de)(de)(de)(de)(de)優越性,因(yin)為(wei)整(zheng)個(ge)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)裝(zhuang)(zhuang)置由幾臺(tai)(tai)單(dan)(dan)(dan)臺(tai)(tai)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)組(zu)(zu)(zu)成(cheng),單(dan)(dan)(dan)臺(tai)(tai)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)容量(liang)(liang)小、電壓(ya)(ya)(ya)(ya)(ya)(ya)低(di)、重量(liang)(liang)輕(qing),便于運(yun)輸(shu)和(he)安(an)裝(zhuang)(zhuang)。它(ta)既然可(ke)串接成(cheng)高出(chu)幾倍(bei)的(de)(de)(de)(de)(de)單(dan)(dan)(dan)臺(tai)(tai)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)輸(shu)出(chu)電壓(ya)(ya)(ya)(ya)(ya)(ya)組(zu)(zu)(zu)合使用(yong),又(you)可(ke)分(fen)(fen)開成(cheng)幾套(tao)單(dan)(dan)(dan)臺(tai)(tai)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)單(dan)(dan)(dan)獨使用(yong)。整(zheng)套(tao)裝(zhuang)(zhuang)置投資(zi)小,經濟實惠。圖5中,在第**和(he)**級(ji)(ji)(ji)(ji)(ji)(ji)的(de)(de)(de)(de)(de)每個(ge)單(dan)(dan)(dan)元試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)中都(dou)有一個(ge)勵磁(ci)(ci)繞組(zu)(zu)(zu)A1、C1和(he)A2、C2。在三(san)(san)臺(tai)(tai)串級(ji)(ji)(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)基(ji)本原理(li)中,低(di)壓(ya)(ya)(ya)(ya)(ya)(ya)電源加在試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)Ⅰ的(de)(de)(de)(de)(de)初(chu)級(ji)(ji)(ji)(ji)(ji)(ji)繞組(zu)(zu)(zu)a1x1上,單(dan)(dan)(dan)臺(tai)(tai)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)Ⅰ、Ⅱ、Ⅲ的(de)(de)(de)(de)(de)輸(shu)出(chu)電壓(ya)(ya)(ya)(ya)(ya)(ya)都(dou)是V。勵磁(ci)(ci)繞組(zu)(zu)(zu)A1、C1給**級(ji)(ji)(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)Ⅱ的(de)(de)(de)(de)(de)初(chu)級(ji)(ji)(ji)(ji)(ji)(ji)繞組(zu)(zu)(zu)供電;**級(ji)(ji)(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)Ⅱ的(de)(de)(de)(de)(de)勵磁(ci)(ci)繞組(zu)(zu)(zu)A2、C2給第三(san)(san)級(ji)(ji)(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)Ⅲ的(de)(de)(de)(de)(de)初(chu)級(ji)(ji)(ji)(ji)(ji)(ji)繞組(zu)(zu)(zu)供電。**級(ji)(ji)(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)Ⅱ和(he)第三(san)(san)級(ji)(ji)(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)Ⅲ的(de)(de)(de)(de)(de)箱體分(fen)(fen)別(bie)處在對(dui)地為(wei)1V和(he)2V的(de)(de)(de)(de)(de)高電位上,所(suo)以箱體對(dui)地是絕緣的(de)(de)(de)(de)(de),試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)Ⅰ的(de)(de)(de)(de)(de)箱體是接地的(de)(de)(de)(de)(de)。這(zhe)樣第**、**級(ji)(ji)(ji)(ji)(ji)(ji)、第三(san)(san)級(ji)(ji)(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)變(bian)(bian)(bian)(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)對(dui)地的(de)(de)(de)(de)(de)額(e)定(ding)輸(shu)出(chu)電壓(ya)(ya)(ya)(ya)(ya)(ya)分(fen)(fen)別(bie)為(wei)1V、2V、3V;其額(e)定(ding)容量(liang)(liang)分(fen)(fen)別(bie)為(wei)3P、2P、1P。
YDQ系列高壓試(shi)驗(yan)變壓器做被試(shi)品的工頻耐壓試(shi)驗(yan)使用接線原理圖(tu)見(jian)圖(tu)5。
圖中:R1—限流電阻 FRC—阻容分(fen)壓器 RF—球間(jian)隙保(bao)護電阻 G—球間(jian)隙 CX—被試品
注(zhu):高(gao)壓尾(wei)必須可靠接地
工頻耐壓試驗(yan)(yan)中限流(liu)電(dian)(dian)(dian)阻R1應根據(ju)試驗(yan)(yan)變壓器的(de)額(e)定容量來選擇。如高(gao)壓側(ce)額(e)定輸(shu)出(chu)電(dian)(dian)(dian)流(liu)在100~300mA時,可取0.5~1Ω/V(試驗(yan)(yan)電(dian)(dian)(dian)壓);高(gao)壓側(ce)額(e)定輸(shu)出(chu)電(dian)(dian)(dian)流(liu)為(wei)(wei)1A以上時,可取1Ω/V(試驗(yan)(yan)電(dian)(dian)(dian)壓)。常用(yong)(yong)水電(dian)(dian)(dian)阻作為(wei)(wei)限流(liu)電(dian)(dian)(dian)阻,管子(zi)長度(du)可按150kV/m考慮,管子(zi)粗細應具有(you)足夠的(de)熱容量(水阻液配制方法:用(yong)(yong)蒸餾水加入適量硫酸(suan)銅(tong)配制成各種不同(tong)的(de)阻值)。
球(qiu)間隙及(ji)保護電(dian)阻:當電(dian)壓超過球(qiu)間隙整(zheng)定值時(shi)(一般(ban)取試驗(yan)(yan)電(dian)壓的110%~120%),球(qiu)間隙放電(dian),對被試品起到保護作用。球(qiu)間隙保護電(dian)阻可按1Ω/V(試驗(yan)(yan)電(dian)壓)選(xuan)取。
在(zai)(zai)工頻耐(nai)壓(ya)(ya)(ya)(ya)(ya)(ya)試驗中,低電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)側測量(liang)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(儀表電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya))不(bu)是(shi)非常(chang)準確的(de)(de),其原因(yin)是(shi)由(you)于(yu)(yu)(yu)試驗變(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)存(cun)在(zai)(zai)著(zhu)漏(lou)抗(kang),在(zai)(zai)這(zhe)個漏(lou)抗(kang)上(shang)必(bi)然存(cun)在(zai)(zai)著(zhu)壓(ya)(ya)(ya)(ya)(ya)(ya)降或容升(sheng),使試品(pin)上(shang)的(de)(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)低于(yu)(yu)(yu)或高于(yu)(yu)(yu)低壓(ya)(ya)(ya)(ya)(ya)(ya)側測量(liang)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)表上(shang)反映出來的(de)(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)。工頻耐(nai)壓(ya)(ya)(ya)(ya)(ya)(ya)試驗時,被(bei)(bei)試品(pin)上(shang)的(de)(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)高于(yu)(yu)(yu)試驗變(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)的(de)(de)輸(shu)出電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya),也(ye)就是(shi)所謂(wei)容升(sheng)現象。感應耐(nai)壓(ya)(ya)(ya)(ya)(ya)(ya)試驗時,試驗變(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)的(de)(de)漏(lou)抗(kang)必(bi)然存(cun)在(zai)(zai)著(zhu)壓(ya)(ya)(ya)(ya)(ya)(ya)降。為了準確測量(liang)被(bei)(bei)試品(pin)上(shang)所施加(jia)的(de)(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya),因(yin)此常(chang)在(zai)(zai)高壓(ya)(ya)(ya)(ya)(ya)(ya)側接入FRC阻容分壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)來測量(liang)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(見圖5)。
工頻耐壓試驗(yan)操作注意事項
1)試驗人(ren)(ren)員應(ying)做好(hao)分工,明確(que)相互間聯系方法。并有專門人(ren)(ren)監護現場**及(ji)觀察試品狀態。
2)被試(shi)品應先清掃干凈,并(bing)**干燥,以(yi)免損壞被試(shi)品和試(shi)驗帶來的誤差。
3)對于大型試驗,一(yi)般都應先進行空升試驗。即(ji)不接(jie)試品時升壓至試驗電壓,校(xiao)對各種表計,調整球間隙。
4)升壓(ya)(ya)速度不能太快,并必(bi)須防止突然(ran)加壓(ya)(ya)。例如調壓(ya)(ya)器(qi)(qi)不在(zai)零位時(shi)突然(ran)合(he)閘。也不能突然(ran)切斷電(dian)源,一般(ban)應在(zai)調壓(ya)(ya)器(qi)(qi)降至零位時(shi)拉閘。
5)當(dang)電(dian)(dian)壓升至試(shi)驗(yan)(yan)電(dian)(dian)壓時,開(kai)始計時,到1min后,迅速降(jiang)壓到1/3試(shi)驗(yan)(yan)電(dian)(dian)壓以下時,才能拉(la)開(kai)電(dian)(dian)源。
6)在升壓(ya)或(huo)耐壓(ya)試(shi)驗(yan)過程(cheng)中(zhong),如發現下列不正常情況時,應立即降(jiang)壓(ya),切斷電源。停止試(shi)驗(yan)并(bing)查明原因:①電壓(ya)表指針擺動很大(da);②發現絕緣(yuan)燒(shao)焦或(huo)冒煙;③被試(shi)品內(nei)有(you)不正常的(de)聲(sheng)音。
7)耐壓試(shi)驗前后(hou)應測(ce)量絕緣電阻,檢(jian)查絕緣情況(kuang)。
試(shi)驗(yan)變壓(ya)器在做被(bei)試(shi)品的直(zhi)流(liu)耐(nai)壓(ya)或泄露試(shi)驗(yan)時(shi)接線原理圖如圖6。
注:此(ci)試驗應先抽出短路桿(gan)“D”,圖6中所示。
圖(tu)中:VD—高壓硅堆 R1—限流電(dian)阻 C1—高壓濾波電(dian)容 FRC—阻容分壓器 CX—被試品 μA—帶保護微安(an)表(biao)
泄(xie)露(lu)試驗中限(xian)流(liu)(liu)(liu)電(dian)阻R1選擇在額定輸出電(dian)壓時,輸出端(duan)短路電(dian)流(liu)(liu)(liu)不超過高壓硅(gui)堆(dui)(dui)的(de)*大整流(liu)(liu)(liu)。如(ru)電(dian)壓硅(gui)堆(dui)(dui)的(de)*大整流(liu)(liu)(liu)電(dian)流(liu)(liu)(liu)為100mA時用于60kV的(de)試驗裝置(zhi)中,限(xian)流(liu)(liu)(liu)電(dian)阻按(an)R1=60/0.1=600kΩ選擇。限(xian)流(liu)(liu)(liu)電(dian)阻還應具(ju)有足夠的(de)容(rong)量(liang)和沿面放電(dian)距離。
高壓(ya)濾波電(dian)容C1一(yi)般選擇在0.01~0.1μF,當被(bei)試品的電(dian)容量很大時,C1可(ke)省略不用。
泄露試驗的操(cao)作及(ji)注意事項(xiang)
1)試(shi)驗(yan)前應(ying)先檢(jian)查被試(shi)品是否停電,接地放電,一(yi)切對外連線是否擦干凈。要嚴防將(jiang)試(shi)驗(yan)電壓加到有(you)人工作(zuo)的(de)部位上去。
2)接(jie)好試驗(yan)裝置(zhi)的(de)(de)接(jie)線后,應復查無誤(wu)后才(cai)可加壓。應特別注(zhu)意檢查高壓設備及引線與地、與操作人員的(de)(de)**距離(li),被試品的(de)(de)外(wai)殼是否可靠(kao)接(jie)地,要按**規(gui)程(cheng)中(zhong)所規(gui)定的(de)(de)內(nei)容進行試驗(yan)。
3)對(dui)于大(da)電(dian)(dian)容量設備應(ying)緩慢升壓(ya),防止被(bei)試品的充電(dian)(dian)電(dian)(dian)流燒壞微安(an)表(biao)。必要(yao)時(shi)應(ying)分級加壓(ya),分別(bie)讀取(qu)各級電(dian)(dian)壓(ya)下(xia)微安(an)表(biao)的穩定讀數。
4)試驗(yan)過程中,應(ying)密切監視被試品(pin)、試驗(yan)裝(zhuang)置、微安表,一旦發生擊穿、閃爍等(deng)異常現象應(ying)立即降(jiang)壓,切斷電源(yuan),并查明(ming)原因,詳細(xi)記(ji)錄。
5)試驗(yan)(yan)完(wan)畢(bi),降(jiang)壓,切斷電(dian)源后應將(jiang)被試品(pin)及試驗(yan)(yan)裝置本身充分放電(dian)。
四(si)、注意事項
1、按照您所(suo)進行的(de)試驗(yan)接好工作(zuo)線(xian)路。試驗(yan)變壓(ya)器的(de)外殼以(yi)及操作(zuo)系統的(de)外殼必須可(ke)靠(kao)接地。試驗(yan)變壓(ya)器高壓(ya)繞組的(de)X端(高壓(ya)尾)以(yi)及測量繞組的(de)F端必須可(ke)靠(kao)接地。
2、做(zuo)串級(ji)(ji)試驗(yan)時(shi),**級(ji)(ji)、第(di)三(san)級(ji)(ji)試驗(yan)變(bian)(bian)壓(ya)器(qi)的(de)低壓(ya)繞組(zu)的(de)X端,測量繞組(zu)的(de)F端以(yi)及高(gao)壓(ya)繞組(zu)的(de)X端(高(gao)壓(ya)尾)均接本級(ji)(ji)試驗(yan)變(bian)(bian)壓(ya)器(qi)的(de)外殼。**級(ji)(ji)、第(di)三(san)級(ji)(ji)試驗(yan)變(bian)(bian)壓(ya)器(qi)的(de)外殼必須通過(guo)絕緣支(zhi)架接地。
3、接通(tong)電源前,操作(zuo)系統的調(diao)壓(ya)器必須(xu)調(diao)到零位后方(fang)可接通(tong)電源,合閘,開始升壓(ya)。
4、從(cong)零(ling)開始均(jun)勻旋轉(zhuan)調壓(ya)(ya)器手(shou)輪升(sheng)(sheng)壓(ya)(ya)。升(sheng)(sheng)壓(ya)(ya)方法(fa)有:快速升(sheng)(sheng)壓(ya)(ya)法(fa),即(ji)20s逐級升(sheng)(sheng)壓(ya)(ya)法(fa);慢(man)速升(sheng)(sheng)壓(ya)(ya)法(fa),即(ji)60s逐級升(sheng)(sheng)壓(ya)(ya)法(fa);極慢(man)速升(sheng)(sheng)壓(ya)(ya)法(fa)供選用(yong)。電壓(ya)(ya)從(cong)零(ling)開始按(an)一定(ding)的(de)(de)升(sheng)(sheng)壓(ya)(ya)方式(shi)和(he)速度上升(sheng)(sheng)到您(nin)所需的(de)(de)額(e)定(ding)試驗電壓(ya)(ya)的(de)(de)75%后,在(zai)以(yi)每秒2%額(e)定(ding)試驗電壓(ya)(ya)的(de)(de)速度升(sheng)(sheng)到您(nin)所需的(de)(de)額(e)定(ding)電壓(ya)(ya),并密切(qie)注意測量儀表的(de)(de)指(zhi)示(shi)以(yi)及被(bei)試品的(de)(de)情(qing)況。升(sheng)(sheng)壓(ya)(ya)過(guo)程中或試驗過(guo)程中如發現(xian)測量儀表的(de)(de)指(zhi)示(shi)及被(bei)試品情(qing)況異(yi)常(chang),應立即(ji)降壓(ya)(ya),切(qie)斷電源,查明(ming)情(qing)況。
5、試驗(yan)完畢后,應在數秒內勻速的將調壓器(qi)返(fan)回至(zhi)零位(wei),然(ran)后切斷電源。
6、本產品不(bu)得超過(guo)額(e)定(ding)參數使(shi)用。除試驗必須外,決不(bu)允許(xu)全(quan)電(dian)(dian)壓(ya)通(tong)電(dian)(dian)或斷電(dian)(dian)。
7、 再升(sheng)壓(ya)或耐壓(ya)試驗過程中,如發現以下不正常(chang)情(qing)況時,應(ying)立即降壓(ya),切(qie)斷電源,停止試驗并(bing)查(cha)明原因。
⑴電(dian)壓表(biao)指針擺動(或(huo)數(shu)字跳動)很(hen)大
⑵電流(liu)表直線上升
被(bei)試(shi)品(pin)內有不正常的聲音
8、圖1中第9項(xiang)系(xi)壓(ya)力(li)閥及(ji)壓(ya)力(li)表,為長(chang)期關閉狀態。每6個月(yue)開閥一(yi)次,以檢查SF6壓(ya)力(li),應(ying)不小于0.2MPa(檢查壓(ya)力(li)后立(li)即關閉閥門),低于0.2MPa時應(ying)加SF6氣(qi)體,以增加氣(qi)絕緣。
9、耐壓實驗前(qian)后應(ying)測(ce)量被(bei)試設(she)備(bei)的絕(jue)(jue)緣電阻(zu),檢查絕(jue)(jue)緣情(qing)況。
10、當試(shi)驗變壓器長期不使用時,應放(fang)置于通風、干燥(zao)、無陽(yang)光直射的(de)地方。
11、該產品不允許(xu)在高于(yu)45℃的溫度下長(chang)期存放、使用(yong)、放氣。
12、運(yun)輸搬運(yun)途中不得重力(li)沖擊。
13、產品緊固件(jian)及壓力閥、壓力表不(bu)得擅自松動。
14、使用(yong)本(ben)產品做高(gao)壓試驗時,出熟悉本(ben)說明(ming)書外,還必須嚴格執行國家有關標(biao)準和操作規(gui)程。可參照GB311-83《高(gao)壓輸變設備的絕緣配合,高(gao)壓試驗技術》;《電氣設備預防(fang)性試驗規(gui)程》等(deng)。
五、試驗變壓(ya)器的(de)容量選擇
標稱試驗變壓器容(rong)量Pn的確定公式:Pn=kVn 2ωCt×10-9
式中:
Pn——標(biao)稱試驗(yan)變壓器容量(kVA)
Vn——試驗變壓器的(de)(de)額(e)定輸出(chu)高(gao)壓的(de)(de)有效值(kV)
k ——**系數。k≥1,標(biao)稱電(dian)壓Vn≥1MV時(shi),k=2;標(biao)稱電(dian)壓較低(di)時(shi),k值可取高一些。
Ct——被試(shi)品的電容量(pF)
ω——角頻(pin)率(lv),ω=2πf,f——試驗電(dian)源(yuan)的頻(pin)率(lv)
被(bei)試設備的(de)電容量Ct可由(you)交流(liu)電橋測出(chu)。Ct的(de)變(bian)化(hua)很大,
可由設(she)備的類型而(er)定。
典型數據如下:
簡單的棒(bang)式或懸式絕(jue)緣子 幾十(shi)微法
簡單的(de)分級(ji)套管(guan) 100~1000pF
電壓互感器 200 ~ 500pF
電力變壓器 < 1000kVA~1000pF
> 1000kVA 1000~10000pF
高壓電(dian)力(li)電(dian)纜和油浸紙絕緣 250~300pF/m
氣體絕(jue)緣(yuan) ~60pF/m
封閉(bi)變電站,SF6氣(qi)體絕(jue)緣 100~10000Pf;
對(dui)于不(bu)同的試驗電壓(ya)Vn,選擇不(bu)同的(適(shi)當的)**系數(shu)k。
以下列出不同的(de)Vn所選用(yong)的(de)k值(zhi)供參(can)考(kao)。
Vn =50~100kV k = 4
Vn =150~300kV k = 3
Vn > 300kV k = 2
一、概述
工頻耐(nai)壓試驗是鑒定(ding)電(dian)力設備(bei)(bei)絕緣強度的*嚴(yan)格、*有效和*直接的方法(fa)。它(ta)能(neng)檢查出那(nei)些危(wei)險性(xing)較(jiao)大的集中缺陷,對判(pan)斷電(dian)力設備(bei)(bei)能(neng)否繼(ji)續參(can)加運(yun)行具有決定(ding)性(xing)作用,是保證設備(bei)(bei)絕緣水平(ping)、避免發生絕緣事(shi)故的重要手(shou)段。
本裝(zhuang)置是根據國家(jia)*新(xin)電(dian)(dian)力行業標準而設計的(de)(de)、性能(neng)先(xian)進(jin)的(de)(de)耐壓(ya)試(shi)驗(yan)設備,用于對各種電(dian)(dian)器產(chan)(chan)品(pin)、電(dian)(dian)氣元件(jian)、絕(jue)緣(yuan)材料等進(jin)行規(gui)定電(dian)(dian)壓(ya)下的(de)(de)絕(jue)緣(yuan)強度試(shi)驗(yan),以考核產(chan)(chan)品(pin)的(de)(de)絕(jue)緣(yuan)水平(ping),發現被試(shi)品(pin)的(de)(de)絕(jue)緣(yuan)缺陷,衡量過電(dian)(dian)壓(ya)的(de)(de)能(neng)力。
二、產品特(te)點
監視功(gong)能:高壓電壓 低壓電流 零位指示(shi) 電源指示(shi) 工作指示(shi) 計時指示(shi)
保(bao)(bao)護(hu)功能(neng):過流保(bao)(bao)護(hu)、零位啟動保(bao)(bao)護(hu)、聲光語(yu)言報(bao)警提醒
采(cai)用新型時間繼(ji)電器,計時范圍更廣(1S~99H)
采(cai)用新(xin)型(xing)電(dian)流繼電(dian)器,更**、更可(ke)靠,確(que)保人身及設備**。
試驗變壓器高壓線(xian)(xian)圈為圓筒多層(ceng)塔式,由上等聚酯漆(qi)包線(xian)(xian)及高耐壓值絕緣材料繞制而(er)成(cheng)。
試驗變壓(ya)器(5kVA以上)裝有可移(yi)動的鐵輪。具有重量輕、體(ti)積小、移(yi)動方(fang)便、性能優(you)越等特點。
三、設(she)備組成
1、選型配置
標準(zhun)配(pei)置(zhi)
|
□ 分體式
|
操作部分:
□箱式(不大于5kVA) / □臺式
容量(liang): kVA(小(xiao)于200kVA)
輸入:□AC220V / □AC380V
|
試驗變壓(ya)器:
□交流 / □交直流
□油變(bian) / □干變(bian) / □氣變(bian)
容量: kVA(小于200kVA)
輸出:AC kV(小于300kVA)
|
□ 一體式
|
□箱式(不大(da)于20kV) / □臺式(不大(da)于30kV)
容量(liang): kVA(小于300kVA)
輸入:□AC220V / □AC380V 輸出:AC kV(不大(da)于30kV)
|
客戶選配
|
□標準高壓分壓器
|
□保護(hu)球隙
|
□直流微安表
|
□放(fang)**
|
□保(bao)護水(shui)阻
|
□高壓濾波電(dian)容(rong)
|
其它(ta):
|
2、對(dui)應實(shi)物
四、技(ji)術(shu)指標(biao)
1、使(shi)用(yong)條件(jian):
(1)工作場所應(ying)無(wu)嚴重影響(xiang)絕緣的氣體、蒸汽、化(hua)學性(xing)(xing)塵埃及其它(ta)爆炸性(xing)(xing)和腐蝕(shi)性(xing)(xing)介質。
(2)環境溫度 -20~+50℃
(3)環境濕度(du) ≤85% RH(無(wu)凝結水)
2、控制箱(xiang)(臺)參(can)數:(常規參(can)數見下表)
規格
|
容量(liang)
|
輸(shu) 入(ru) 電 源
|
輸 出 電 壓
|
重(zhong)量(kg)
|
相數
|
(V)
|
(A)
|
(V)
|
(A)
|
2/220
|
2
|
1
|
220
|
10
|
0-250
|
8
|
14
|
3/220
|
3
|
1
|
220
|
15
|
0-250
|
12
|
16
|
5/220
|
5
|
1
|
220
|
25
|
0-250
|
20
|
18
|
10/220
|
10
|
1
|
220
|
50
|
0-250
|
40
|
80
|
15/380
|
15
|
2
|
380
|
37.5
|
0-430
|
34.8
|
90
|
20/380
|
20
|
2
|
380
|
50
|
0-430
|
46.5
|
100
|
25/380
|
25
|
2
|
380
|
62.5
|
0-430
|
58.1
|
120
|
30/380
|
30
|
2
|
380
|
75
|
0-430
|
69.7
|
140
|
50/380
|
50
|
2
|
380
|
125
|
0-430
|
116.2
|
160
|
100/380
|
100
|
2
|
380
|
250
|
0-430
|
232.5
|
250
|
說明:如有特殊參(can)數要求,可(ke)按用戶的技術參(can)數進行(xing)設計制(zhi)作。
3、試(shi)驗(yan)變壓器參(can)數:(常(chang)規參(can)數見(jian)下表)
規格
|
容量(liang)
kVA
|
低壓側
|
高壓側(ce)
|
高(gao)壓側(交直(zhi)流變壓器)
|
測量變比
|
60分鐘溫升℃
|
阻抗電壓%
|
空載電流
%
|
質量
kg
|
電壓
V
|
電流(liu)
A
|
交(jiao)流輸出
|
直(zhi)流輸出
|
電壓kV
|
電流
|
電(dian)壓(ya)kV
|
電流
|
1.5/50
|
1.5
|
200
|
7.5
|
50
|
30
|
70
|
21.4
|
500
|
50
|
10
|
<4
|
19.5
|
3/50
|
3
|
200
|
15
|
50
|
60
|
70
|
42.9
|
500
|
50
|
10
|
<4
|
27
|
5/50
|
5
|
200
|
25
|
50
|
100
|
70
|
71.4
|
500
|
50
|
10
|
<4
|
52
|
10/50
|
10
|
200
|
50
|
50
|
200
|
70
|
142.9
|
500
|
50
|
10
|
<4
|
80
|
15/50
|
15
|
400
|
37.5
|
50
|
300
|
70
|
214.3
|
500
|
50
|
8
|
<4
|
120
|
20/50
|
20
|
400
|
50
|
50
|
400
|
70
|
285.7
|
500
|
50
|
8
|
<4
|
140
|
30/50
|
30
|
400
|
75
|
50
|
600
|
70
|
428.6
|
500
|
50
|
8
|
<4
|
155
|
50/50
|
50
|
400
|
125
|
50
|
1000
|
70
|
714.3
|
500
|
50
|
8
|
<4
|
184
|
10/100
|
10
|
200
|
50
|
100
|
100
|
140
|
71.4
|
1000
|
50
|
10
|
<4
|
135
|
15/100
|
15
|
400
|
37.5
|
100
|
150
|
140
|
107.1
|
1000
|
50
|
8
|
<4
|
150
|
20/100
|
20
|
400
|
50
|
100
|
200
|
140
|
142.9
|
1000
|
50
|
8
|
<4
|
215
|
30/100
|
30
|
400
|
75
|
100
|
300
|
140
|
214.3
|
1000
|
50
|
8
|
<4
|
250
|
50/100
|
50
|
400
|
125
|
100
|
500
|
140
|
357.1
|
1000
|
50
|
8
|
<4
|
290
|
10/150
|
10
|
200
|
50
|
100
|
66.7
|
140
|
47.6
|
1500
|
50
|
10
|
<4
|
180
|
15/150
|
15
|
400
|
37.5
|
150
|
100
|
210
|
71.4
|
1500
|
50
|
8
|
<4
|
200
|
20/150
|
30
|
400
|
50
|
150
|
133.3
|
210
|
95.2
|
1500
|
50
|
8
|
<4
|
220
|
30/150
|
30
|
400
|
75
|
150
|
200
|
210
|
142.9
|
1500
|
50
|
8
|
<4
|
280
|
50/150
|
50
|
400
|
125
|
150
|
333.3
|
210
|
238.1
|
1500
|
50
|
8
|
<4
|
340
|
說明:如有特(te)殊參(can)數(shu)要求(qiu),可(ke)按(an)用戶的(de)技術(shu)參(can)數(shu)進(jin)行設計(ji)制作。
上(shang)表(biao)的重(zhong)量以油浸式(shi)試驗(yan)變壓器(qi)為例,干式(shi)試驗(yan)變壓器(qi)和充氣式(shi)試驗(yan)變壓器(qi)稍有不同。
五、接線及工作(zuo)原(yuan)理(li)
1、調(diao)壓部分(fen)接線及(ji)原理(li)
調(diao)壓(ya)部(bu)(bu)分(fen)(fen)由控制部(bu)(bu)分(fen)(fen)和(he)試(shi)驗(yan)變壓(ya)器(qi)組(zu)成。控制部(bu)(bu)分(fen)(fen)是由接觸式調(diao)壓(ya)器(qi)及其(qi)控制、保護、測量、信號電路組(zu)成。試(shi)驗(yan)變壓(ya)器(qi)由低壓(ya)繞組(zu)、高壓(ya)繞組(zu)、儀表繞組(zu)三部(bu)(bu)分(fen)(fen)組(zu)成。
試(shi)驗(yan)變(bian)壓(ya)器為(wei)交(jiao)直(zhi)流(liu)兩用時(shi),試(shi)驗(yan)變(bian)壓(ya)器配置了高(gao)壓(ya)硅堆(dui)(dui)(dui)(油變(bian)、氣(qi)(qi)變(bian)為(wei)內置,干(gan)變(bian)為(wei)外(wai)置),高(gao)壓(ya)可輸(shu)出交(jiao)流(liu)和直(zhi)流(liu)。輸(shu)出交(jiao)流(liu)時(shi),要求接入(ru)短(duan)路(lu)桿(gan)(油變(bian)、氣(qi)(qi)變(bian))或(huo)去掉外(wai)置硅堆(dui)(dui)(dui)(干(gan)變(bian));輸(shu)出直(zhi)流(liu)時(shi),要求擰出短(duan)路(lu)桿(gan)(油變(bian)、氣(qi)(qi)變(bian))或(huo)加上(shang)外(wai)置硅堆(dui)(dui)(dui)(干(gan)變(bian))
通(tong)過接入(ru)工頻電源,調節調壓(ya)器,以(yi)獲得所需要的試驗高壓(ya)電壓(ya)值。其工作原理見圖1:
2、試驗(yan)部分接線及原理
做(zuo)耐壓(ya)(ya)(ya)(ya)試驗時,控制部(bu)分、變壓(ya)(ya)(ya)(ya)器(qi)的接地端及(ji)高壓(ya)(ya)(ya)(ya)尾必須可靠接地。有條(tiao)件的情況下,做(zuo)工頻耐壓(ya)(ya)(ya)(ya)試驗請加上限流電阻、標準高壓(ya)(ya)(ya)(ya)分壓(ya)(ya)(ya)(ya)器(qi)、球隙(xi)保護(hu)電阻及(ji)保護(hu)球隙(xi),如圖3。
做直(zhi)流(liu)耐壓(ya)試驗(yan)請另外(wai)(wai)加上微(wei)安(an)表,微(wei)安(an)表必須接(jie)在硅(gui)堆和被試器之間(jian),油變或氣(qi)(qi)變一(yi)般擰在高(gao)壓(ya)頭上面(mian)(要求擰出短(duan)路桿),干變擰在外(wai)(wai)置硅(gui)堆上面(mian);為了更準(zhun)確顯示(shi)高(gao)壓(ya)直(zhi)流(liu)泄漏電流(liu),請將(jiang)分(fen)壓(ya)器的(de)高(gao)壓(ya)線接(jie)在微(wei)安(an)表和硅(gui)堆之間(jian),(油變、氣(qi)(qi)變)如圖4,(干變)如圖5。
耐壓(ya)試驗(yan)中限流(liu)電(dian)阻(zu)(zu)R1應(ying)根據試驗(yan)變壓(ya)器(qi)的額定容量來(lai)選擇(ze)。如高壓(ya)側(ce)額定輸(shu)出(chu)電(dian)流(liu)在100~300mA時(shi),可取0.5~1Ω/V(試驗(yan)電(dian)壓(ya));高壓(ya)側(ce)額定輸(shu)出(chu)電(dian)流(liu)為(wei)1A以上時(shi),可取1Ω/V(試驗(yan)電(dian)壓(ya))。常用(yong)水(shui)電(dian)阻(zu)(zu)作為(wei)限流(liu)電(dian)阻(zu)(zu),管子長度可按(an)150kV/m考慮,管子粗細應(ying)具有足(zu)夠的熱(re)容量(水(shui)阻(zu)(zu)液配制方法:用(yong)蒸餾水(shui)加(jia)入(ru)適量硫酸銅配制成(cheng)各種不同(tong)的阻(zu)(zu)值)。
球間(jian)隙(xi)及保(bao)護(hu)電阻(zu):當(dang)電壓(ya)超過球間(jian)隙(xi)整定值時(一般取(qu)試驗(yan)電壓(ya)的110%~120%),球間(jian)隙(xi)放電,對(dui)被試品起(qi)到保(bao)護(hu)作用。球間(jian)隙(xi)保(bao)護(hu)電阻(zu)可按1Ω/V(試驗(yan)電壓(ya))選(xuan)取(qu)。
在(zai)(zai)(zai)工頻(pin)耐(nai)壓(ya)(ya)試(shi)(shi)(shi)驗中,低電(dian)壓(ya)(ya)側(ce)測量(liang)電(dian)壓(ya)(ya)(儀表電(dian)壓(ya)(ya))不是非常(chang)準確的(de),其原(yuan)因(yin)是由于(yu)(yu)試(shi)(shi)(shi)驗變(bian)壓(ya)(ya)器存在(zai)(zai)(zai)著(zhu)漏抗(kang)(kang),在(zai)(zai)(zai)這個漏抗(kang)(kang)上必然存在(zai)(zai)(zai)著(zhu)壓(ya)(ya)降或容(rong)升(sheng),使試(shi)(shi)(shi)品(pin)上的(de)電(dian)壓(ya)(ya)低于(yu)(yu)或高(gao)于(yu)(yu)低壓(ya)(ya)側(ce)測量(liang)電(dian)壓(ya)(ya)表上反映(ying)出(chu)來的(de)電(dian)壓(ya)(ya)。工頻(pin)耐(nai)壓(ya)(ya)試(shi)(shi)(shi)驗時,被試(shi)(shi)(shi)品(pin)上的(de)電(dian)壓(ya)(ya)高(gao)于(yu)(yu)試(shi)(shi)(shi)驗變(bian)壓(ya)(ya)器的(de)輸出(chu)電(dian)壓(ya)(ya),也就是所謂容(rong)升(sheng)現象。感應耐(nai)壓(ya)(ya)試(shi)(shi)(shi)驗時,試(shi)(shi)(shi)驗變(bian)壓(ya)(ya)器的(de)漏抗(kang)(kang)必然存在(zai)(zai)(zai)著(zhu)壓(ya)(ya)降。為了準確測量(liang)被試(shi)(shi)(shi)品(pin)上所施加的(de)電(dian)壓(ya)(ya),因(yin)此常(chang)在(zai)(zai)(zai)高(gao)壓(ya)(ya)側(ce)接入標(biao)準高(gao)壓(ya)(ya)分(fen)壓(ya)(ya)器來測量(liang)電(dian)壓(ya)(ya)。
五、面板結構說(shuo)明
1、操作箱面板
控制箱(xiang)為箱(xiang)式鋁合金結(jie)構,面(mian)板(ban)采用(yong)拉絲(si)鋁合金工藝(yi),所有電(dian)器元(yuan)件(jian)均裝(zhuang)在骨架上,便于安(an)裝(zhuang)和維修。面(mian)板(ban)元(yuan)件(jian)布(bu)置如下:
2、操作臺面板(ban)
操作(zuo)臺(tai)為臺(tai)式結構,殼體(ti)為冷扎鋼板結構,面(mian)板采用鋁合金拉絲工藝(yi),面(mian)板元(yuan)件布置如下(xia):
六、操作指南
本(ben)裝置在操(cao)作(zuo)之前應根據(ju)不同被試(shi)品的容量(liang)、電壓(ya)等(deng)級,先計算好(hao)*大工作(zuo)電流,并調整(zheng)電流保護器。其試(shi)驗(yan)接線應參(can)考本(ben)說(shuo)明書中圖1、圖2、圖3、圖4、圖5,必須可靠接地。
1、操作要點
(1)試驗(yan)(yan)前,應(ying)了解被(bei)試品的(de)(de)試驗(yan)(yan)電壓(ya),同(tong)時了解被(bei)試品的(de)(de)其他試驗(yan)(yan)項目及以前的(de)(de)試驗(yan)(yan)結果。若被(bei)試品有缺(que)陷或異常,應(ying)在(zai)消除后再進(jin)行耐壓(ya)試驗(yan)(yan)。
(2)試驗(yan)現(xian)場應圍(wei)好遮攔或(huo)圍(wei)繩,掛好標示牌,并派專人監護。
(3)試驗前,被(bei)試品(pin)(pin)表(biao)面(mian)應(ying)擦拭干凈,將被(bei)試品(pin)(pin)的(de)(de)(de)外(wai)殼和(he)非被(bei)試繞組可(ke)靠(kao)接地。被(bei)試品(pin)(pin)為新(xin)沖(chong)油設(she)(she)(she)備時(shi),應(ying)按《規(gui)程》規(gui)定使(shi)油靜(jing)(jing)止(zhi)一定時(shi)間(jian)再(zai)升壓(ya),對(dui)110kV及以下(xia)的(de)(de)(de)充油電力設(she)(she)(she)備,在注(zhu)滿油后靜(jing)(jing)置時(shi)間(jian)應(ying)不少(shao)于(yu)24小時(shi),對(dui)220kV及330kV的(de)(de)(de)充油電力設(she)(she)(she)備,靜(jing)(jing)置時(shi)間(jian)應(ying)不少(shao)于(yu)48小時(shi)。
(4)接好試(shi)驗接線后(hou),應由有經(jing)驗的(de)人(ren)員檢查,確認無誤后(hou)方(fang)可升壓。
(5)升(sheng)壓(ya)前,首先檢查調壓(ya)器(qi)是否在零位(wei)。調壓(ya)器(qi)在零位(wei)方可(ke)升(sheng)壓(ya)。
(6)升壓(ya)過程中不(bu)僅(jin)要監(jian)視電(dian)壓(ya)表的(de)變化,還(huan)應監(jian)視電(dian)流表的(de)變化,以及(ji)被(bei)試品(pin)電(dian)流的(de)變化。升壓(ya)時要均勻升壓(ya),不(bu)能太快(kuai)。升至規定試驗(yan)電(dian)壓(ya)時,開始計算(suan)時間,時間到后(hou),緩(huan)慢均勻降(jiang)(jiang)下電(dian)壓(ya)。絕不(bu)允許不(bu)降(jiang)(jiang)壓(ya)就(jiu)先跳(tiao)開電(dian)源開關。
(7)試驗(yan)中發現表針擺動或被試品有異常聲響(xiang)、冒煙等應立即(ji)降(jiang)下電壓,拉開(kai)電源,在高壓側掛(gua)上接地(di)線(xian)后(hou),再查明(ming)原因。
(8)耐壓試驗前后均應測量被試品的絕緣電阻。
2、操(cao)作(zuo)步驟
(1) 按試(shi)驗要求(qiu)將控制部分、試(shi)驗變壓(ya)器、被試(shi)品(pin)正確接好(hao)線(xian),必須可靠接地,請(qing)參考圖1、圖2、圖3、圖4、圖5。
(2) 根據(ju)試驗的要求,整定“時間(jian)繼電(dian)(dian)器”及“過流繼電(dian)(dian)器”。
A 時間繼(ji)電器設置:
T1,T2,T3,T4設置(zhi)(zhi)0~9任意數字,T可設置(zhi)(zhi)為H(小時),M(分(fen)鐘),S(秒)。
根據(ju)試驗(yan)要求,在1S~99H內(nei)可以任意設置定(ding)時時間(jian)。
B 過流繼電器設置(zhi):
過流(liu)(liu)(liu)動作設定(ding)值=過流(liu)(liu)(liu)繼電(dian)器(qi)刻度盤(pan)讀(du)數×測量變比×K,其中K為(wei)電(dian)流(liu)(liu)(liu)倍率/切(qie)(qie)除開(kai)關的狀態值,分(fen)別為(wei)X1,X2,OFF,電(dian)流(liu)(liu)(liu)倍率/切(qie)(qie)除開(kai)關處(chu)于×1,×2位置時(shi),K值分(fen)別為(wei)1、2,切(qie)(qie)換為(wei)OFF擋(dang)時(shi),K值為(wei)+∞。(注:不要使用OFF檔,因(yin)為(wei)會使變壓器(qi)失去過流(liu)(liu)(liu)保護功能而導(dao)致設備損壞。測量變比為(wei)電(dian)流(liu)(liu)(liu)互感(gan)(gan)器(qi)的變比,沒有電(dian)流(liu)(liu)(liu)互感(gan)(gan)器(qi)時(shi)為(wei)1)。
(3) 接入電(dian)源,此時,“電(dian)源燈(deng)(deng)”亮(liang)(liang),表示(shi)外部電(dian)源已(yi)引入。如(ru)“零(ling)位燈(deng)(deng)”亮(liang)(liang),表示(shi)調(diao)壓器在零(ling)位。如(ru)“零(ling)位燈(deng)(deng)”不亮(liang)(liang),應逆時針旋轉調(diao)節調(diao)壓器手柄至“零(ling)位燈(deng)(deng)”亮(liang)(liang),表示(shi)可進行調(diao)壓操作(zuo)。
(4)按“啟動按鈕”。此(ci)時,“送(song)電燈”,“電源燈”和“零位(wei)燈”亮;進入(ru)送(song)電狀態(tai)。
(5)以2kV/S勻速順時針旋轉調壓器手柄至被試品規(gui)定的耐(nai)壓值,并密切(qie)注(zhu)(zhu)視(shi)電(dian)流(liu)(liu)表(biao)(直流(liu)(liu)耐(nai)壓試驗時,同時密切(qie)注(zhu)(zhu)視(shi)直流(liu)(liu)微安表(biao))。此時,“電(dian)源(yuan)燈”,“工作(zuo)燈”亮;“零(ling)位燈”滅。
(6)根據試(shi)驗啟動“計時按鈕”,計時開始(shi),并注意被試(shi)品(pin)的情況。
(7)當耐壓計時(shi)(shi)到時(shi)(shi),操作臺自(zi)動聲光報警。應立即逆時(shi)(shi)針旋(xuan)轉調(diao)壓器(qi)手(shou)柄至零位,按(an)下停止按(an)鈕(niu)和解(jie)除計時(shi)(shi)按(an)鈕(niu)自(zi)鎖狀態。此時(shi)(shi)“電源燈”, “零位燈”亮,“工(gong)作燈”滅。試驗即告完畢
(8)拔掉電源,拆(chai)除接線,試(shi)驗結束。
(9)在升壓(ya)(ya)或耐壓(ya)(ya)過程中,如發生短路、閃絡、擊穿過流時(shi),過流繼電(dian)器(qi)(qi)動作,切斷主回(hui)路。此(ci)時(shi)應將調壓(ya)(ya)器(qi)(qi)逆時(shi)針旋轉至零位,切斷電(dian)源,并查明原因,并作詳細記錄(lu)。
(10)試驗(yan)完畢,降壓,切斷電源后應用放(fang)**將被試品及(ji)試驗(yan)裝置本身充分放(fang)電。
七、產品維護
1、開箱驗收(shou)時(shi),應檢查主控回路接(jie)線是否(fou)松(song)動,調(diao)壓器電(dian)刷是否(fou)接(jie)觸(chu)良好;
2、長期不用(yong)(yong)時,使用(yong)(yong)前應用(yong)(yong)500V兆歐表測量絕緣電阻,其阻值不低于0.5MΩ;
3、電源電壓應符合控制箱(xiang)(臺)銘牌(pai)上的輸(shu)入(ru)電壓值;
4、本裝置(zhi)設有過電(dian)流保護,出廠已調整(zheng)為(wei)額(e)定電(dian)流的(de)50%。用于小負載時,應(ying)根(gen)據被試品的(de)額(e)定容量電(dian)流重新設定;
5、使用完畢后,應關(guan)好控(kong)制(zhi)箱(xiang)(臺)門(men),以保持控(kong)制(zhi)箱(xiang)(臺)內部清(qing)潔。
八、注意事(shi)項
1、按照(zhao)您(nin)所進行的試驗接(jie)好工作線路。試驗變(bian)壓器(qi)的外殼(ke)(ke)以及操作系統的外殼(ke)(ke)必(bi)須可(ke)靠接(jie)地。試驗變(bian)壓器(qi)的高壓繞組的X端(高壓尾)以及測量繞組的F端必(bi)須可(ke)靠接(jie)地。
2、做串級(ji)試(shi)驗(yan)時,**級(ji)、第(di)三級(ji)試(shi)驗(yan)變(bian)壓器(qi)的(de)(de)低壓繞(rao)(rao)組(zu)(zu)成X端(duan),測量繞(rao)(rao)組(zu)(zu)的(de)(de)F端(duan)以及高壓繞(rao)(rao)組(zu)(zu)的(de)(de)X端(duan)(高壓端(duan))均(jun)接本級(ji)試(shi)驗(yan)變(bian)壓器(qi)具外(wai)殼。**級(ji)、第(di)三級(ji)試(shi)驗(yan)變(bian)壓器(qi)的(de)(de)外(wai)殼必須通過(guo)絕緣支架接地。
3、接通電(dian)(dian)源前,操作系統的(de)(de)調壓(ya)(ya)(ya)(ya)器(qi)必(bi)須(xu)調到(dao)零(ling)位(wei)后方(fang)可接通電(dian)(dian)源,合閘,開始(shi)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)。從零(ling)開始(shi)勻(yun)速(su)(su)(su)旋轉調壓(ya)(ya)(ya)(ya)器(qi)手(shou)輪升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)。升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)方(fang)式有:快速(su)(su)(su)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)法(fa),即(ji)20s逐級(ji)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)法(fa);慢速(su)(su)(su)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)法(fa),即(ji)60s逐級(ji)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)法(fa);極慢速(su)(su)(su)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)法(fa)供選用(yong)。電(dian)(dian)壓(ya)(ya)(ya)(ya)從零(ling)開始(shi)按一定(ding)的(de)(de)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)方(fang)式和(he)速(su)(su)(su)度(du)上升(sheng)(sheng)(sheng)(sheng)到(dao)您所(suo)(suo)需的(de)(de)額(e)定(ding)試驗電(dian)(dian)壓(ya)(ya)(ya)(ya)的(de)(de)75%后,再以每秒2%額(e)定(ding)試驗電(dian)(dian)壓(ya)(ya)(ya)(ya)的(de)(de)速(su)(su)(su)度(du)升(sheng)(sheng)(sheng)(sheng)到(dao)您所(suo)(suo)需的(de)(de)試驗電(dian)(dian)壓(ya)(ya)(ya)(ya),并密(mi)切注意測量儀表(biao)的(de)(de)及(ji)被試品(pin)(pin)的(de)(de)情況(kuang)。升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)(ya)過程中或試驗過程中如(ru)發現測量儀表(biao)的(de)(de)指示及(ji)被試品(pin)(pin)情況(kuang)異(yi)常,應立(li)即(ji)降壓(ya)(ya)(ya)(ya),切斷電(dian)(dian)源,查明情況(kuang)。
4、試驗完畢后,應在數秒內勻速的將調壓器返回至零(ling)位,然后切斷電源。本產品不得超過額定(ding)參數使用。
5、使用本產品做高壓(ya)試驗(yan)時,除熟悉本說明(ming)書(shu)外,還(huan)必須嚴格執(zhi)行國家有關標(biao)準和操(cao)作規(gui)程(cheng)。可(ke)參照GB311.1 – 97《高壓(ya)輸變設(she)備(bei)的絕緣配合,高壓(ya)試驗(yan)技術》;《電氣設(she)備(bei)預防性試驗(yan)規(gui)程(cheng)》等
一、概(gai)述(shu)
智(zhi)能(neng)耐(nai)壓試(shi)驗裝(zhuang)置是根據國家*新電(dian)力(li)(li)行(xing)業標(biao)準而設計的、性能(neng)先進的智(zhi)能(neng)型(xing)耐(nai)壓試(shi)驗設備,用(yong)(yong)于對各種電(dian)器產(chan)品、電(dian)氣元件(jian)、絕(jue)緣材料等進行(xing)規定電(dian)壓下的絕(jue)緣強度(du)試(shi)驗,以考核(he)產(chan)品的絕(jue)緣水(shui)平,發現(xian)被試(shi)品的絕(jue)緣缺陷,衡(heng)量過電(dian)壓的能(neng)力(li)(li)。廣(guang)泛應用(yong)(yong)于電(dian)工(gong)制造部門、電(dian)力(li)(li)運行(xing)部門、科(ke)研單位和高等院校(xiao)。
二、產品(pin)特點(dian)
1. 320×240液(ye)晶顯示器、高速熱(re)敏打印機。
2. 高壓(ya)(ya)電壓(ya)(ya)、高壓(ya)(ya)電流、低壓(ya)(ya)電壓(ya)(ya)、低壓(ya)(ya)電流4路測量(liang)方式(shi),高精度傳感器和高性(xing)能14位AD采(cai)集芯片。
3. 人機(ji)對話全(quan)(quan)鍵盤操作(zuo)方式,智能化工作(zuo)全(quan)(quan)過程,任選(xuan)自動方式和手動方式。
4. 實(shi)時顯示高壓(ya)(ya)(ya)電壓(ya)(ya)(ya)、高壓(ya)(ya)(ya)電流(liu)、低壓(ya)(ya)(ya)電壓(ya)(ya)(ya)、低壓(ya)(ya)(ya)電流(liu),時間及耐壓(ya)(ya)(ya)結果,顯示直觀明了。
5. 完(wan)善(shan)的(de)過壓、過流保護,任意設定輸出電壓、高壓電流上限、低(di)壓電流上限和(he)計時時間。
6. 具(ju)有(you)回零檢測(ce)功能,回零確定(ding)后(hou)才可進行試(shi)驗(yan),**可靠。
7. 具有絕緣(yuan)電阻測試(shi)功能,直接反映被試(shi)品絕緣(yuan)強(qiang)度。
8. 逼近式(shi)調壓(ya)算法,到達設(she)定(ding)電(dian)壓(ya)后自(zi)動(dong)耐壓(ya)計時(shi),計時(shi)結束(shu)后自(zi)動(dong)降壓(ya)回(hui)零。
9. 超過(guo)設定高壓(ya)(ya)(ya)電流或低壓(ya)(ya)(ya)電流時自動(dong)切斷電壓(ya)(ya)(ya)輸出,降壓(ya)(ya)(ya)回零(ling),并發生聲(sheng)光報警(jing)。
10. 精良的軟硬件抗干擾(rao)設計,多(duo)種(zhong)抗干擾(rao)手段,適應惡劣電磁環境。
11. 自動錯誤診斷(duan),易于發現和解決問題。
12. 可選配無線遙控(kong)(kong)控(kong)(kong)制功能、遠(yuan)程通信、門聯鎖(suo)警(jing)鈴、外接(jie)分壓器校驗接(jie)口等。
三、設備組(zu)成
1、選型(xing)配置
標準配置(zhi)
|
□ 分體式
|
操(cao)作(zuo)部(bu)分:
□箱式(不大于5kVA) / □臺式
容量: kVA(小于200kVA)
輸(shu)入:□AC220V / □AC380V
|
試(shi)驗變壓器(qi):
□交(jiao)流 / □交(jiao)直流
□油(you)變(bian) / □干變(bian) / □氣變(bian)
容量: kVA(小于200kVA)
輸出:AC kV(小于300kVA)
|
□ 一體式(shi)
|
□箱式(不大于20kV) / □臺式(不大于30kV)
容量(liang): kVA(小于(yu)300kVA)
輸入:□AC220V / □AC380V 輸出:AC kV(不大于(yu)30kV)
|
客戶(hu)選配
|
□標(biao)準高壓分(fen)壓器
|
□保護球隙
|
□直流微安(an)表
|
□放**
|
□保(bao)護水(shui)阻
|
□高壓濾波(bo)電容
|
其它:
|
2、對應(ying)實(shi)物
四(si)、技術指標
1、使用條件(jian):
(1)工作場所應無嚴(yan)重影響(xiang)絕緣的氣體、蒸(zheng)汽、化學(xue)性(xing)塵埃及(ji)其(qi)它爆炸性(xing)和腐蝕(shi)性(xing)介質。
(2)環境(jing)溫度 -20~+50℃
(3)環境濕度(du) ≤85% RH(無凝(ning)結水(shui))
2、控制箱(臺(tai))參數:(常(chang)規參數見下(xia)表)
(1)計(ji)時范圍:0-999S
(3)電壓精度 ≤1.5% ±1個字(F.S)
(4)電流精度 ≤1.5% ±1個字(F.S)
規格
|
容量
|
輸(shu) 入 電(dian) 源(yuan)
|
輸(shu) 出(chu) 電(dian) 壓
|
重量(kg)
|
相數
|
(V)
|
(A)
|
(V)
|
(A)
|
2/220
|
2
|
1
|
220
|
10
|
0-250
|
8
|
14
|
3/220
|
3
|
1
|
220
|
15
|
0-250
|
12
|
16
|
5/220
|
5
|
1
|
220
|
25
|
0-250
|
20
|
18
|
10/220
|
10
|
1
|
220
|
50
|
0-250
|
40
|
80
|
15/380
|
15
|
2
|
380
|
37.5
|
0-430
|
34.8
|
90
|
20/380
|
20
|
2
|
380
|
50
|
0-430
|
46.5
|
100
|
25/380
|
25
|
2
|
380
|
62.5
|
0-430
|
58.1
|
120
|
30/380
|
30
|
2
|
380
|
75
|
0-430
|
69.7
|
140
|
50/380
|
50
|
2
|
380
|
125
|
0-430
|
116.2
|
160
|
100/380
|
100
|
2
|
380
|
250
|
0-430
|
232.5
|
250
|
說(shuo)明(ming):如(ru)有特殊參(can)(can)數要求,可按用(yong)戶的技(ji)術參(can)(can)數進行設(she)計制作。
3、試驗(yan)變壓器參數:(常規(gui)參數見下表(biao))
規格
|
容(rong)量
kVA
|
低壓側(ce)
|
高(gao)壓側(ce)
|
高壓側(交直流變(bian)壓器)
|
測量變(bian)比(bi)
|
60分鐘溫升℃
|
阻抗電壓%
|
空(kong)載電流
%
|
質量
kg
|
電壓
V
|
電流(liu)
A
|
交流輸出
|
直流(liu)輸出(chu)
|
電壓kV
|
電流
|
電壓kV
|
電流
|
1.5/50
|
1.5
|
200
|
7.5
|
50
|
30
|
70
|
21.4
|
500
|
50
|
10
|
<4
|
19.5
|
3/50
|
3
|
200
|
15
|
50
|
60
|
70
|
42.9
|
500
|
50
|
10
|
<4
|
27
|
5/50
|
5
|
200
|
25
|
50
|
100
|
70
|
71.4
|
500
|
50
|
10
|
<4
|
52
|
10/50
|
10
|
200
|
50
|
50
|
200
|
70
|
142.9
|
500
|
50
|
10
|
<4
|
80
|
15/50
|
15
|
400
|
37.5
|
50
|
300
|
70
|
214.3
|
500
|
50
|
8
|
<4
|
120
|
20/50
|
20
|
400
|
50
|
50
|
400
|
70
|
285.7
|
500
|
50
|
8
|
<4
|
140
|
30/50
|
30
|
400
|
75
|
50
|
600
|
70
|
428.6
|
500
|
50
|
8
|
<4
|
155
|
50/50
|
50
|
400
|
125
|
50
|
1000
|
70
|
714.3
|
500
|
50
|
8
|
<4
|
184
|
10/100
|
10
|
200
|
50
|
100
|
100
|
140
|
71.4
|
1000
|
50
|
10
|
<4
|
135
|
15/100
|
15
|
400
|
37.5
|
100
|
150
|
140
|
107.1
|
1000
|
50
|
8
|
<4
|
150
|
20/100
|
20
|
400
|
50
|
100
|
200
|
140
|
142.9
|
1000
|
50
|
8
|
<4
|
215
|
30/100
|
30
|
400
|
75
|
100
|
300
|
140
|
214.3
|
1000
|
50
|
8
|
<4
|
250
|
50/100
|
50
|
400
|
125
|
100
|
500
|
140
|
357.1
|
1000
|
50
|
8
|
<4
|
290
|
10/150
|
10
|
200
|
50
|
100
|
66.7
|
140
|
47.6
|
1500
|
50
|
10
|
<4
|
180
|
15/150
|
15
|
400
|
37.5
|
150
|
100
|
210
|
71.4
|
1500
|
50
|
8
|
<4
|
200
|
20/150
|
30
|
400
|
50
|
150
|
133.3
|
210
|
95.2
|
1500
|
50
|
8
|
<4
|
220
|
30/150
|
30
|
400
|
75
|
150
|
200
|
210
|
142.9
|
1500
|
50
|
8
|
<4
|
280
|
50/150
|
50
|
400
|
125
|
150
|
333.3
|
210
|
238.1
|
1500
|
50
|
8
|
<4
|
340
|
說明:如有特殊參數(shu)要(yao)求,可按用戶的技術參數(shu)進(jin)行設計制作。
上表(biao)的重量以(yi)油浸式(shi)試驗(yan)變(bian)壓(ya)器為例,干式(shi)試驗(yan)變(bian)壓(ya)器和充氣式(shi)試驗(yan)變(bian)壓(ya)器稍有不同(tong)。
五(wu)、接線(xian)及工作原(yuan)理
1、調(diao)壓(ya)部分接線(xian)及原理
調壓(ya)部(bu)分(fen)(fen)由(you)(you)控(kong)制(zhi)部(bu)分(fen)(fen)和試驗變壓(ya)器(qi)(qi)組(zu)成。控(kong)制(zhi)部(bu)分(fen)(fen)是由(you)(you)接觸(chu)式(shi)調壓(ya)器(qi)(qi)、單片機控(kong)制(zhi)系統、液晶、打印機、信(xin)號測量、電路保(bao)護組(zu)成。試驗變壓(ya)器(qi)(qi)由(you)(you)低壓(ya)繞組(zu)、高(gao)壓(ya)繞組(zu)、儀表繞組(zu)三(san)部(bu)分(fen)(fen)組(zu)成。
試驗(yan)變(bian)壓(ya)器(qi)為交直(zhi)(zhi)(zhi)流兩用時,試驗(yan)變(bian)壓(ya)器(qi)配置了(le)高壓(ya)硅(gui)堆(dui)(油變(bian)、氣變(bian)為內置,干(gan)變(bian)為外(wai)置),高壓(ya)可輸(shu)出交流和直(zhi)(zhi)(zhi)流。輸(shu)出交流時,要(yao)求(qiu)接入短路桿(油變(bian)、氣變(bian))或去(qu)掉外(wai)置硅(gui)堆(dui)(干(gan)變(bian));輸(shu)出直(zhi)(zhi)(zhi)流時,要(yao)求(qiu)擰出短路桿(油變(bian)、氣變(bian))或加上外(wai)置硅(gui)堆(dui)(干(gan)變(bian))
通過接入工(gong)頻電(dian)源,調節(jie)調壓(ya)器,以獲得所需要的試驗高(gao)壓(ya)電(dian)壓(ya)值。其工(gong)作原理見圖1:
2、試驗部分接(jie)線及(ji)原(yuan)理
做耐壓試驗時,控制部分、變壓器的(de)接(jie)地端及(ji)高壓尾必須可靠(kao)接(jie)地。有(you)條(tiao)件的(de)情況下,做工頻耐壓試驗請加上限流電阻、標準(zhun)高壓分壓器、球(qiu)隙(xi)保(bao)護電阻及(ji)保(bao)護球(qiu)隙(xi),如(ru)圖(tu)3。
做直流(liu)(liu)耐壓(ya)試驗請另外加(jia)上微安表,微安表必須接在(zai)硅堆(dui)和(he)被試器之(zhi)間(jian),油變(bian)或氣變(bian)一般(ban)擰在(zai)高(gao)壓(ya)頭上面(要求擰出(chu)短(duan)路桿),干變(bian)擰在(zai)外置(zhi)硅堆(dui)上面;為(wei)了更準(zhun)確顯示高(gao)壓(ya)直流(liu)(liu)泄漏電(dian)流(liu)(liu),請將(jiang)分(fen)壓(ya)器的高(gao)壓(ya)線接在(zai)微安表和(he)硅堆(dui)之(zhi)間(jian),(油變(bian)、氣變(bian))如圖4,(干變(bian))如圖5。
耐壓試驗中(zhong)限流電阻(zu)(zu)R1應根據試驗變壓器(qi)的額(e)定容量(liang)來選擇。如高壓側額(e)定輸出(chu)(chu)電流在100~300mA時,可(ke)取(qu)0.5~1Ω/V(試驗電壓);高壓側額(e)定輸出(chu)(chu)電流為1A以上(shang)時,可(ke)取(qu)1Ω/V(試驗電壓)。常用水(shui)電阻(zu)(zu)作為限流電阻(zu)(zu),管子長度可(ke)按150kV/m考慮(lv),管子粗細應具有足(zu)夠的熱(re)容量(liang)(水(shui)阻(zu)(zu)液配制方法:用蒸(zheng)餾水(shui)加(jia)入適量(liang)硫酸銅(tong)配制成(cheng)各種不(bu)同(tong)的阻(zu)(zu)值(zhi))。
球(qiu)(qiu)間(jian)隙(xi)(xi)及保(bao)護電(dian)阻:當電(dian)壓(ya)超過球(qiu)(qiu)間(jian)隙(xi)(xi)整定值時(一般(ban)取(qu)試驗(yan)電(dian)壓(ya)的110%~120%),球(qiu)(qiu)間(jian)隙(xi)(xi)放電(dian),對被試品(pin)起到保(bao)護作用。球(qiu)(qiu)間(jian)隙(xi)(xi)保(bao)護電(dian)阻可(ke)按1Ω/V(試驗(yan)電(dian)壓(ya))選取(qu)。
在工頻耐壓(ya)試(shi)(shi)驗(yan)(yan)中,低電(dian)壓(ya)側測(ce)(ce)量電(dian)壓(ya)(儀表(biao)電(dian)壓(ya))不是非常準(zhun)確的(de),其(qi)原(yuan)因是由于(yu)(yu)試(shi)(shi)驗(yan)(yan)變壓(ya)器存在著漏抗(kang),在這(zhe)個漏抗(kang)上(shang)(shang)(shang)必然(ran)存在著壓(ya)降(jiang)或(huo)容升,使(shi)試(shi)(shi)品(pin)(pin)上(shang)(shang)(shang)的(de)電(dian)壓(ya)低于(yu)(yu)或(huo)高于(yu)(yu)低壓(ya)側測(ce)(ce)量電(dian)壓(ya)表(biao)上(shang)(shang)(shang)反映出來的(de)電(dian)壓(ya)。工頻耐壓(ya)試(shi)(shi)驗(yan)(yan)時,被試(shi)(shi)品(pin)(pin)上(shang)(shang)(shang)的(de)電(dian)壓(ya)高于(yu)(yu)試(shi)(shi)驗(yan)(yan)變壓(ya)器的(de)輸出電(dian)壓(ya),也就是所(suo)謂(wei)容升現象。感應耐壓(ya)試(shi)(shi)驗(yan)(yan)時,試(shi)(shi)驗(yan)(yan)變壓(ya)器的(de)漏抗(kang)必然(ran)存在著壓(ya)降(jiang)。為了準(zhun)確測(ce)(ce)量被試(shi)(shi)品(pin)(pin)上(shang)(shang)(shang)所(suo)施加的(de)電(dian)壓(ya),因此常在高壓(ya)側接入標準(zhun)高壓(ya)分壓(ya)器來測(ce)(ce)量電(dian)壓(ya)。
六、操作要點
1、試(shi)驗前(qian)(qian),應了解被(bei)試(shi)品的(de)試(shi)驗電(dian)壓,同時了解被(bei)試(shi)品的(de)其他(ta)試(shi)驗項目及以(yi)前(qian)(qian)的(de)試(shi)驗結果。若被(bei)試(shi)品有缺(que)陷或異常,應在消除后再進行耐壓試(shi)驗。
2、試驗現場(chang)應圍(wei)好遮(zhe)攔(lan)或圍(wei)繩(sheng),掛好標(biao)示牌,并派專人監(jian)護。
3、試驗前,被(bei)試品表面應擦拭干凈,將被(bei)試品的(de)外(wai)殼和(he)非被(bei)試繞組可(ke)靠接地。被(bei)試品為新沖油設備時(shi),應按《規(gui)程》規(gui)定(ding)使油靜止一定(ding)時(shi)間再升壓,對110kV及(ji)以下的(de)充油電力設備,在注滿油后(hou)靜置時(shi)間應不少(shao)于24小(xiao)時(shi),對220kV及(ji)330kV的(de)充油電力設備,靜置時(shi)間應不少(shao)于48小(xiao)時(shi)。
4、接好試(shi)驗(yan)接線后(hou)(hou),應由有經驗(yan)的人員檢查,確認無誤(wu)后(hou)(hou)方可(ke)升壓。
5、升壓(ya)(ya)前,首先檢查(cha)調壓(ya)(ya)器是否(fou)在零位。調壓(ya)(ya)器在零位方可(ke)升壓(ya)(ya)。
6、升(sheng)壓(ya)(ya)過程中不僅要監(jian)視電(dian)壓(ya)(ya)的(de)變(bian)化(hua),還應監(jian)視電(dian)流(liu)的(de)變(bian)化(hua),以及(ji)被試品(pin)泄漏電(dian)流(liu)的(de)變(bian)化(hua)。升(sheng)壓(ya)(ya)時(shi)要均(jun)勻(yun)升(sheng)壓(ya)(ya),不能太快。升(sheng)至規定試驗電(dian)壓(ya)(ya)時(shi),開始(shi)計時(shi),時(shi)間(jian)到后,緩慢(man)均(jun)勻(yun)降下電(dian)壓(ya)(ya)。絕不允(yun)許(xu)不降壓(ya)(ya)就先跳開電(dian)源開關。
7、試(shi)驗中發現(xian)被(bei)試(shi)品(pin)有(you)異常聲響(xiang)、冒煙等應立即降下電(dian)壓(ya),拉開電(dian)源,在高壓(ya)側掛上(shang)接地線(xian)后,再(zai)查明原因(yin)。耐(nai)壓(ya)試(shi)驗前后均應測(ce)量被(bei)試(shi)品(pin)的(de)絕緣電(dian)阻。
七、面板功能說明
打(da)印(yin)(yin)機(ji)(ji):打(da)印(yin)(yin)機(ji)(ji)是熱敏(min)打(da)印(yin)(yin)機(ji)(ji),當試(shi)驗完成(cheng)后按鍵盤上的“打(da)印(yin)(yin)”按鈕打(da)印(yin)(yin)試(shi)驗結(jie)果。
RS232:RS232是與計算機相連的(de)串口(kou)通信(xin)接(jie)口(kou),是用戶選配(pei)接(jie)口(kou),本(ben)裝置(zhi)沒(mei)有配(pei)置(zhi)這個(ge)接(jie)口(kou)。
LCD對比(bi)度(du):因為液晶顯示屏在溫度(du)和光(guang)線有所不同(tong)時稍有些變化(hua),可(ke)以通過LCD對比(bi)度(du)調(diao)節背光(guang)到適合亮度(du)。
液晶: 320x240像素點陣白色背光液晶,在強光和陰暗環境下(xia)都十分(fen)清楚。
指示燈(deng):由啟(qi)動(dong)燈(deng)、零位(wei)燈(deng)、指示燈(deng)三個燈(deng)組成,啟(qi)動(dong)燈(deng)和警示燈(deng)是(shi)高(gao)亮七彩燈(deng)。
操作提示:有(you)一些簡短的提示語句(ju)和安裝接線(xian)圖(tu)。
緊(jin)急開關:在緊(jin)急情(qing)況下按此開關,即(ji)可以切斷變(bian)壓器電(dian)源,也可以切斷工(gong)作電(dian)源。(箱(xiang)式安(an)裝(zhuang)在面板上,臺(tai)式安(an)裝(zhuang)在柜體上)
鍵(jian)盤:由上、下(xia)、左、右、設(she)置(zhi)、打印、確定(ding)、取消8個(ge)鍵(jian)組成,是用戶和設(she)備交互的(de)終端。
電(dian)源開關:工作電(dian)源,帶(dai)通(tong)電(dian)指示燈。
八、軟件(jian)使用說明
按(an)試(shi)驗要(yao)求將控制(zhi)部(bu)分、試(shi)驗變壓器、被試(shi)品正(zheng)確(que)接好線,必須可靠接地,請參考(kao)圖(tu)(tu)1、圖(tu)(tu)2、圖(tu)(tu)3、圖(tu)(tu)4、圖(tu)(tu)5。
1、開機使用
開機處于“歡迎界面”,如圖7:
根據鍵盤的示圖8,按(an)上↑、下↓、左(zuo)←,右→可(ke)以切換“自(zi)動耐(nai)壓(ya)試驗(yan)(yan)(yan)(yan)”或(huo)“手動耐(nai)壓(ya)試驗(yan)(yan)(yan)(yan)”,在“自(zi)動試驗(yan)(yan)(yan)(yan)”或(huo)“手動試驗(yan)(yan)(yan)(yan)”里面選擇(ze)“交(jiao)流(liu)試驗(yan)(yan)(yan)(yan)方式”或(huo)“直流(liu)試驗(yan)(yan)(yan)(yan)方式”。如(ru)圖9
說(shuo)明(ming):
(1)當配置(zhi)的是交(jiao)(jiao)直(zhi)流(liu)兩用(yong)控制部分時,使用(yong)直(zhi)流(liu)輸出時軟件操作請進入直(zhi)流(liu)試(shi)驗(yan)方式(shi),交(jiao)(jiao)流(liu)輸出時軟件操作請進入交(jiao)(jiao)流(liu)試(shi)驗(yan)方式(shi),如(ru)果選(xuan)擇錯誤(wu)會導致(zhi)儀(yi)器顯(xian)示電(dian)壓(ya)會和輸出實際電(dian)壓(ya)不(bu)一致(zhi)。
(2)當(dang)配置的是交直(zhi)流兩用(yong)變壓器(qi)時,使(shi)用(yong)直(zhi)流時請(qing)將(jiang)變壓器(qi)的短路桿取出(chu),當(dang)使(shi)用(yong)交流時請(qing)將(jiang)短路桿插入擰緊。
(3)如(ru)果配置(zhi)的是交(jiao)流(liu)控(kong)制部分時,軟件界面里就沒有交(jiao)直(zhi)流(liu)試驗方式(如(ru)圖9)的選擇(ze)項。
選中試驗(yan)方式后(hou),按確定可以進(jin)入主界(jie)面(mian),如(ru)圖10:
動態(tai)顯示區:一直處于采集(ji)信(xin)號,并顯示高(gao)壓(ya)(ya)電壓(ya)(ya)、高(gao)壓(ya)(ya)電流、低壓(ya)(ya)電壓(ya)(ya)、低壓(ya)(ya)電流。
結果顯(xian)(xian)示區:如果試驗沒有(you)被擊穿時,顯(xian)(xian)示平(ping)均(jun)高壓(ya)(ya)(ya)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya),平(ping)均(jun)高壓(ya)(ya)(ya)電(dian)(dian)(dian)(dian)流(liu),平(ping)均(jun)低壓(ya)(ya)(ya)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya),平(ping)均(jun)低壓(ya)(ya)(ya)電(dian)(dian)(dian)(dian)流(liu),絕緣電(dian)(dian)(dian)(dian)阻;否之,顯(xian)(xian)示峰(feng)值電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya),峰(feng)值電(dian)(dian)(dian)(dian)流(liu),低壓(ya)(ya)(ya)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya),低壓(ya)(ya)(ya)電(dian)(dian)(dian)(dian)流(liu)。
設(she)(she)置(zhi)數(shu)據(ju)區:設(she)(she)置(zhi)試(shi)驗中需(xu)要的(de)(de)參數(shu)數(shu)據(ju)輸(shu)出電(dian)(dian)壓(ya)(ya)為(wei)在(zai)自動方式下的(de)(de)升壓(ya)(ya)目標耐(nai)壓(ya)(ya)值耐(nai)壓(ya)(ya)時(shi)間為(wei)耐(nai)壓(ya)(ya)過(guo)程的(de)(de)時(shi)間長(chang)度電(dian)(dian)流(liu)上(shang)限為(wei)高壓(ya)(ya)電(dian)(dian)流(liu)峰(feng)值的(de)(de)上(shang)限,高壓(ya)(ya)電(dian)(dian)流(liu)超過(guo)電(dian)(dian)流(liu)上(shang)限將(jiang)認為(wei)擊穿(chuan)(chuan)過(guo)流(liu)保護為(wei)低壓(ya)(ya)電(dian)(dian)流(liu)峰(feng)值的(de)(de)上(shang)限,低壓(ya)(ya)電(dian)(dian)流(liu)超過(guo)過(guo)流(liu)保護將(jiang)認為(wei)擊穿(chuan)(chuan)
信息顯示(shi)(shi)區:顯示(shi)(shi)試(shi)(shi)驗過程中的試(shi)(shi)驗狀態和提示(shi)(shi)信息。
試(shi)驗(yan)操作區:選擇設置(zhi)、試(shi)驗(yan)、回零命令。
2、設(she)置參數
在主界(jie)面(mian)上,選中“設置(zhi)”,然后按確定后進(jin)入設置(zhi)界(jie)面(mian),如圖11:
按(an)左←,右→時(shi)(shi)切換光(guang)標(biao)(biao)(biao)移動(dong)位置(zhi),按(an)上↑、下↓時(shi)(shi)更(geng)改光(guang)標(biao)(biao)(biao)位置(zhi)數(shu)據的(de)值。光(guang)標(biao)(biao)(biao)位置(zhi)和(he)設(she)置(zhi)的(de)數(shu)值全部可以自(zi)動(dong)循環,前且在使用(yong)時(shi)(shi)有默認的(de)標(biao)(biao)(biao)準值。如果所有的(de)參數(shu)都設(she)置(zhi)完成,按(an)取消退(tui)出設(she)置(zhi)回到主(zhu)界面開始狀態。
3、手動試驗
零(ling)(ling)位檢(jian)查—當選中(zhong)“試(shi)驗(yan)”后,按確定就進入提示試(shi)驗(yan)狀態。如果調壓器不(bu)在(zai)零(ling)(ling)位,將提示“試(shi)驗(yan)前請先回零(ling)(ling)”,退(tui)出試(shi)驗(yan)并(bing)且切換到(dao)回零(ling)(ling)命令。
試驗過程—回(hui)零(ling)確(que)(que)認后,可以進行試驗。選(xuan)中“試驗”后按確(que)(que)定,接觸器合閘,這時(shi)輸(shu)出電壓幾乎(hu)為0,如圖12:
按(an)上(shang)↑,高壓(ya)電壓(ya)將不斷(duan)升(sheng)壓(ya),松開就停止(zhi)升(sheng)壓(ya),如(ru)果到(dao)上(shang)限就提示(shi)滿量程(cheng);
按下↓,高(gao)壓(ya)電壓(ya)將不(bu)斷(duan)降壓(ya),松開就停止降壓(ya),如果(guo)到下限就提示已回(hui)零;
按計時(shi)←,計時(shi)開(kai)始工作,到(dao)耐壓時(shi)間計時(shi)結束完成試(shi)驗;
按取(qu)消(xiao)→,取(qu)消(xiao)試驗過程;
在(zai)升(sheng)壓(ya)(ya)(ya)(ya)過(guo)程中,如果高壓(ya)(ya)(ya)(ya)電(dian)流(liu)(liu)峰(feng)值(zhi)(zhi)(zhi)超過(guo)“電(dian)流(liu)(liu)上限”值(zhi)(zhi)(zhi)或低(di)壓(ya)(ya)(ya)(ya)電(dian)流(liu)(liu)峰(feng)值(zhi)(zhi)(zhi)超過(guo)“過(guo)流(liu)(liu)保護”值(zhi)(zhi)(zhi)將認為被(bei)試(shi)品(pin)被(bei)擊穿,接觸器(qi)立(li)刻分閘(zha)并顯示(shi)試(shi)驗結(jie)(jie)果,包括(kuo)峰(feng)值(zhi)(zhi)(zhi)電(dian)壓(ya)(ya)(ya)(ya)、峰(feng)值(zhi)(zhi)(zhi)電(dian)流(liu)(liu)、低(di)壓(ya)(ya)(ya)(ya)電(dian)流(liu)(liu)等,調(diao)壓(ya)(ya)(ya)(ya)器(qi)開(kai)始(shi)回(hui)(hui)零(ling)(ling),回(hui)(hui)零(ling)(ling)完(wan)成試(shi)驗結(jie)(jie)束(shu)。如果在(zai)耐壓(ya)(ya)(ya)(ya)過(guo)程中,高壓(ya)(ya)(ya)(ya)電(dian)流(liu)(liu)和(he)低(di)壓(ya)(ya)(ya)(ya)電(dian)流(liu)(liu)峰(feng)值(zhi)(zhi)(zhi)沒有(you)超設(she)置上限值(zhi)(zhi)(zhi),認為被(bei)試(shi)品(pin)未擊穿,結(jie)(jie)果顯示(shi)區就(jiu)顯示(shi)耐壓(ya)(ya)(ya)(ya)電(dian)壓(ya)(ya)(ya)(ya)、高壓(ya)(ya)(ya)(ya)電(dian)流(liu)(liu)、低(di)壓(ya)(ya)(ya)(ya)電(dian)流(liu)(liu)、絕緣電(dian)阻(zu)等,調(diao)壓(ya)(ya)(ya)(ya)器(qi)開(kai)始(shi)回(hui)(hui)零(ling)(ling),回(hui)(hui)零(ling)(ling)完(wan)成后接觸器(qi)分閘(zha)試(shi)驗結(jie)(jie)束(shu)。
4、自動試驗
自動試驗和手動試驗的試驗過(guo)程類似,首先也進行回(hui)零檢查,確認(ren)后進入如下界(jie)面(mian),如圖13:
按上方法(fa)切換到“開始”確定后(hou)進行試驗(yan),與手動(dong)試驗(yan)不同之處就是升(sheng)壓(ya)(ya)過(guo)程將自(zi)動(dong)升(sheng)壓(ya)(ya)到“輸(shu)出電壓(ya)(ya)”值,然后(hou)進行計時。
升壓過程(cheng)為(wei)逼近(jin)(jin)方(fang)式(shi),首先升到到接(jie)近(jin)(jin)目標(biao)值(zhi),然后(hou)再進行微(wei)調,保證高壓電(dian)壓值(zhi)幾乎為(wei)輸出電(dian)壓值(zhi)。
5、功能選(xuan)擇
按鍵盤上的(de)“設置”就進入功(gong)能界面(mian),如圖14:
進(jin)入功能界面(mian)后,可以選擇“時鐘設置”、“注意(yi)事(shi)項”等界面(mian)。
時(shi)鐘設置:設置時(shi)鐘的(de)時(shi)間(jian),為打印報(bao)表提供時(shi)間(jian)依(yi)據。
注意事項(xiang):為用戶提(ti)供一些(xie)操作規范和(he)**注意事項(xiang)。
6、打印(yin)
按鍵盤“打印(yin)(yin)”按鍵可以打印(yin)(yin)試驗果,在此(ci)不(bu)贅述。
七(qi)、產品維護(hu)
1、開箱驗收時,應檢查主控回路接線是(shi)否(fou)松動(dong),調壓器電刷(shua)是(shi)否(fou)接觸(chu)良好。
2.、長(chang)期(qi)不用(yong)(yong)時,使用(yong)(yong)前應(ying)用(yong)(yong)500V兆歐(ou)表測量絕(jue)緣電阻,其阻值不低于0.5MΩ。
3、電(dian)源電(dian)壓(ya)應符(fu)合控制箱(臺)說明書上的輸(shu)入(ru)電(dian)壓(ya)值要求。
4、本控制箱(臺)設(she)有過(guo)電(dian)流保(bao)護(hu),出廠已調整為額定(ding)電(dian)流的(de)50%。用于小負(fu)載時(shi),應根(gen)據被試品(pin)的(de)額定(ding)容量電(dian)流重新設(she)定(ding);
5、使用完(wan)畢后,應關好控制箱(臺)門蓋,以保持內部清潔(jie)。
八、注意事項
1、按照您所進行的(de)(de)(de)試(shi)驗接(jie)好工(gong)作(zuo)線路。試(shi)驗變壓器(qi)的(de)(de)(de)外殼(ke)以及(ji)操作(zuo)系統的(de)(de)(de)外殼(ke)必(bi)須可靠(kao)接(jie)地(di)。試(shi)驗變壓器(qi)的(de)(de)(de)測量(liang)繞組的(de)(de)(de)F端和(he)外殼(ke)必(bi)須可靠(kao)接(jie)地(di)。
2、做串級(ji)試(shi)(shi)驗時,**級(ji)、第三(san)級(ji)試(shi)(shi)驗變(bian)壓器的低壓繞組(zu)成X端(duan),測量繞組(zu)的F端(duan)以及高壓繞組(zu)的X端(duan)(高壓端(duan))均接本級(ji)試(shi)(shi)驗變(bian)壓器具外(wai)殼。**級(ji)、第三(san)級(ji)試(shi)(shi)驗變(bian)壓器的外(wai)殼必須通過絕緣支架接地。
接通電源前,控制(zhi)箱(xiang)(臺)的調壓器(qi)必須調到(dao)零位后方(fang)可接通電源,合閘,開始升壓。
3、從(cong)零開始勻速(su)旋(xuan)轉(zhuan)調壓(ya)(ya)(ya)(ya)(ya)(ya)器手輪升(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)。升(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)方式有:快速(su)升(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)法(fa)(fa)(fa),即20s逐級升(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)法(fa)(fa)(fa);慢速(su)升(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)法(fa)(fa)(fa),即60s逐級升(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)法(fa)(fa)(fa);極(ji)慢速(su)升(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)法(fa)(fa)(fa)供選用。電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)從(cong)零開始按一定的(de)(de)升(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)方式和速(su)度(du)上升(sheng)(sheng)到您所(suo)需(xu)的(de)(de)額(e)定試驗(yan)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)的(de)(de)75%后(hou),再(zai)以每秒2%額(e)定試驗(yan)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)的(de)(de)速(su)度(du)升(sheng)(sheng)到您所(suo)需(xu)的(de)(de)試驗(yan)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya),并密切(qie)注意測量儀表的(de)(de)及(ji)被(bei)試品的(de)(de)情況。升(sheng)(sheng)壓(ya)(ya)(ya)(ya)(ya)(ya)過(guo)(guo)程中(zhong)或(huo)試驗(yan)過(guo)(guo)程中(zhong)如(ru)發現(xian)測量儀表的(de)(de)指示及(ji)被(bei)試品情況異常,應立即降(jiang)壓(ya)(ya)(ya)(ya)(ya)(ya),切(qie)斷電(dian)(dian)(dian)源(yuan),查明情況。
4、試驗完(wan)畢后(hou),應在等調壓器返回至(zhi)零(ling)位(wei),然后(hou)切(qie)斷(duan)電源。
5、本產品(pin)不(bu)得超(chao)過額定參數使用。
6、使用本(ben)產品(pin)做高(gao)壓試(shi)(shi)驗(yan)時,除熟悉本(ben)說明書外,還必須嚴格執(zhi)行(xing)國家有關(guan)標準和操(cao)作規程。可參照GB311.1 – 97《高(gao)壓輸變設備(bei)的絕緣配(pei)合,高(gao)壓試(shi)(shi)驗(yan)技術》;《電氣(qi)設備(bei)預防(fang)性試(shi)(shi)驗(yan)規程》等。
7、控(kong)(kong)制(zhi)箱(臺)應與試驗變壓器配套使(shi)用,控(kong)(kong)制(zhi)箱(臺)的使(shi)用方法,請詳(xiang)細(xi)參閱(yue)控(kong)(kong)制(zhi)器的使(shi)用說(shuo)明(ming)書。