一、WBYD2000變頻串并聯諧振耐壓基本原理
耐壓(ya)(ya)(ya)試(shi)驗(yan)是利用(yong)(yong)電(dian)抗器(qi)的電(dian)感(gan)與(yu)被(bei)試(shi)品電(dian)容組成LC串聯回路,調節變頻電(dian)源輸出的電(dian)壓(ya)(ya)(ya)頻率,在被(bei)試(shi)品上獲得高電(dian)壓(ya)(ya)(ya),是當前(qian)高電(dian)壓(ya)(ya)(ya)試(shi)驗(yan)的一(yi)種(zhong)新方(fang)法,深受專家(jia)好評,在國內外(wai)已經(jing)得到(dao)廣泛的使用(yong)(yong)。
根據諧(xie)振(zhen)(zhen)原(yuan)理,我(wo)們知道當電(dian)抗(kang)器(qi)L的感(gan)抗(kang)值(zhi)Xl與回(hui)路中的容(rong)抗(kang)值(zhi)Xc相等(deng)時,回(hui)路達(da)到諧(xie)振(zhen)(zhen)狀(zhuang)態,此時回(hui)路中僅回(hui)路電(dian)阻R消耗有功(gong)功(gong)率,而(er)無功(gong)功(gong)率則在電(dian)抗(kang)器(qi)與試(shi)品電(dian)容(rong)之(zhi)間來回(hui)振(zhen)(zhen)蕩,從而(er)在試(shi)品上(shang)產生高壓。
二、WBYD2000變頻串并聯諧振耐壓系統構成
全套試(shi)驗系統由調頻電(dian)源主機、電(dian)抗器(qi)、分壓(ya)器(qi)、激(ji)勵變壓(ya)器(qi)和(he)補償電(dian)容(rong)器(qi)(可選器(qi)件)組(zu)成,接入被試(shi)品后組(zu)成一個諧振(zhen)系統進行交流耐壓(ya)實驗。
主機: 就是一臺幅(fu)值和頻(pin)率可調(diao)的(de)正弦波交流調(diao)頻(pin)電源(yuan),給(gei)諧振回路提供激勵源(yuan),同時提供電壓顯(xian)示、電流顯(xian)示、計時、保護、報警(jing)等功能。
電(dian)(dian)抗(kang)(kang)器(qi):就是(shi)一(yi)個大電(dian)(dian)感(gan)線圈,與被試(shi)品(相當(dang)于(yu)電(dian)(dian)容)構成回路,可配置(zhi)電(dian)(dian)抗(kang)(kang)器(qi)多節(jie)電(dian)(dian)抗(kang)(kang)器(qi),使用(yong)時通過不同的(de)串聯、并聯組(zu)合(he)、實現(xian)不同的(de)電(dian)(dian)感(gan)量以適用(yong)不同的(de)試(shi)驗條件。
分壓器(qi)(qi):內部通(tong)過(guo)電(dian)容器(qi)(qi)分壓,從(cong)試品上高電(dian)壓分得低電(dian)壓供主(zhu)機測量、控制使用(yong)。
勵磁(ci)變(bian)壓(ya)器:隔離(li)主(zhu)機(ji)電源與諧振回路電源,并升高主(zhu)機(ji)的輸出電壓(ya)。
補償(chang)電容器(qi):當試(shi)品(pin)電容量很(hen)小(xiao)時,如(ru)果要(yao)實現系統諧振可能(neng)要(yao)求的電源頻率超出試(shi)驗(yan)標準(zhun)的規(gui)定,可在試(shi)品(pin)上并聯一個補償(chang)電容,以實現試(shi)驗(yan)要(yao)求,稱此電容器(qi)為補償(chang)電容器(qi)。
三、WBYD2000變頻串并聯諧振耐壓主要技術性能
功率電源(yuan)電壓:AC380V±10%、50Hz;
儀器電源:220V±10%、50Hz;
諧振輸(shu)出容量:200kVA;
儀(yi)器(qi)額(e)定電壓:0~200kV;
輸出(chu)頻率范圍:30~300Hz;
輸出電(dian)壓波形(xing):正弦波,波形(xing)畸變率<0.5%;
頻率調節靈敏度:0.1Hz,不穩定度≤0.05%;
系統噪聲:≤60db;
9、系統測量精(jing)度(du):<1級;
10.輸出電壓不穩(wen)定(ding):<0.5%;
11.保護響應時間:1us;
12.電感非(fei)線性度:≤0.05%;;
13.滿功率(lv)輸(shu)出下(xia),連續工(gong)作時間為60min
14.環境(jing)溫度:-15℃~+50℃;
15.相對濕度(du):≤90%RH;
16.海拔高(gao)度:≤2000米。
四、WBYD2000變頻串并聯諧振耐壓面板及部件名稱
五、WBYD2000變頻串并聯諧振耐壓操作步驟
1、正確連線,檢查無誤(wu)后(hou)方可送電。
必要時工作電源的(de)跳過現(xian)場(chang)漏電保安器,以(yi)免不必要的(de)跳閘。
2、打開電源開關,主機開始工(gong)作,液(ye)晶屏(ping)顯示版(ban)(ban)權頁,該頁標(biao)明本(ben)(ben)裝置的(de)軟件版(ban)(ban)本(ben)(ben)號。
觸按確(que)認鍵,進(jin)入系統菜(cai)單(dan),該主菜(cai)單(dan)下(xia)有(you):試驗(yan)方(fang)案、開(kai)始(shi)試驗(yan)、試驗(yan)幫助、系統設(she)置、實(shi)用工具和(he)試驗(yan)記錄等六個(ge)子菜(cai)單(dan)項。
3、 系(xi)統(tong)(tong)設(she)置(zhi)(zhi)菜(cai)(cai)單(dan)下有電抗器電感、日(ri)期時(shi)間(jian)設(she)置(zhi)(zhi)和采(cai)樣系(xi)數(shu)設(she)置(zhi)(zhi)等(deng)三個子菜(cai)(cai)單(dan)項(xiang)(xiang)。按上下鍵,上下移動光標系(xi)統(tong)(tong)參數(shu)設(she)置(zhi)(zhi)菜(cai)(cai)單(dan)項(xiang)(xiang),觸(chu)按確定鈕后,進入系(xi)統(tong)(tong)參數(shu)設(she)置(zhi)(zhi)菜(cai)(cai)單(dan),可以分別設(she)定電抗器的(de)電感—H、-年-月-日(ri)、-時(shi)-分-秒和電壓和電流(liu)的(de)采(cai)樣系(xi)數(shu)也就是(shi)采(cai)樣倍率,設(she)定完成后,觸(chu)按返還鍵返回上**菜(cai)(cai)單(dan)。
電抗(kang)器電感(gan)量的(de)設定:按(an)確定鍵(jian)選擇到此(ci)項,按(an)左(zuo)右鍵(jian)移動(dong)光標(biao)需要改變(bian)的(de)數(shu)位,按(an)上下鍵(jian)改變(bian)數(shu)值,達到所要達到的(de)數(shu)值按(an)確定鍵(jian)確認。
日期時(shi)間的設定(ding):按(an)(an)確定(ding)鍵(jian)選擇到此項,按(an)(an)左(zuo)右鍵(jian)移(yi)動光標需要改變(bian)的數(shu)位(wei),按(an)(an)上下(xia)鍵(jian)改變(bian)數(shu)值(zhi),按(an)(an)照所要設置的年月日時(shi)間數(shu)值(zhi)按(an)(an)確定(ding)鍵(jian)確認(ren)。
采樣(yang)(yang)系(xi)數的(de)(de)設(she)定(ding):按確定(ding)鍵選擇到高壓(ya)(ya)/電(dian)(dian)流采樣(yang)(yang)系(xi)數項(xiang),此項(xiang)為電(dian)(dian)壓(ya)(ya)或電(dian)(dian)流采樣(yang)(yang)倍率(lv)的(de)(de)設(she)定(ding)。一(yi)(yi)般(ban)出廠前(qian)設(she)定(ding)好了。如需修改,要(yao)輸入密碼。(密碼廠家與設(she)備(bei)一(yi)(yi)起提(ti)供一(yi)(yi)般(ban)設(she)定(ding)為:188888)
警告:系(xi)統默認上(shang)一(yi)次(ci)電(dian)(dian)抗器(qi)電(dian)(dian)感(gan)、日期時間和采樣系(xi)數設(she)定值。如果需改變要(yao)重新設(she)定。電(dian)(dian)抗器(qi)電(dian)(dian)感(gan)量設(she)定值與實際使用(yong)的電(dian)(dian)抗器(qi)電(dian)(dian)感(gan)量不(bu)(bu)對,會導(dao)致(zhi)試驗(yan)報(bao)告中的被(bei)試品(pin)電(dian)(dian)容量不(bu)(bu)準。其他并不(bu)(bu)會影(ying)響(xiang)。采樣系(xi)數設(she)置不(bu)(bu)正確,會導(dao)致(zhi)顯示電(dian)(dian)壓電(dian)(dian)流不(bu)(bu)準將很(hen)有可能會對被(bei)試品(pin)或試驗(yan)設(she)備造成損壞。
4、試驗(yan)方(fang)案菜單下有(you)預(yu)置(zhi)保護電(dian)流、找(zhao)(zhao)頻(pin)(pin)起(qi)始頻(pin)(pin)率、找(zhao)(zhao)頻(pin)(pin)結束(shu)頻(pin)(pin)率、預(yu)定起(qi)始功率四個子菜單項,分別設(she)(she)定本(ben)次試驗(yan)的保護電(dian)流、找(zhao)(zhao)頻(pin)(pin)起(qi)始頻(pin)(pin)率、找(zhao)(zhao)頻(pin)(pin)結束(shu)頻(pin)(pin)率、輸出起(qi)始功率,全部設(she)(she)定完成后(hou),觸按返還鍵(jian)進入預(yu)置(zhi)試驗(yan)電(dian)壓和預(yu)置(zhi)試驗(yan)時間設(she)(she)置(zhi)菜單。
可以分(fen)(fen)3段時間設置(zhi)試驗(yan)電壓和試驗(yan)時間, 實際試驗(yan)時,若設定為自動(dong)試驗(yan), 裝置(zhi)將按(an)設定的3段電壓及時間,按(an)順序分(fen)(fen)別(bie)加壓, 全部(bu)完成后自動(dong)退出.
如果**段(duan)(duan)電(dian)(dian)壓設(she)為0, 或時間設(she)為0, 那(nei)么執(zhi)行完**段(duan)(duan)試驗(yan)電(dian)(dian)壓加壓后退出試驗(yan), 只加壓**段(duan)(duan)設(she)定的(de)電(dian)(dian)壓.
如果第三段電壓設為(wei)0, 或時間設為(wei)0, 不執行(xing)第三段加(jia)壓.
試(shi)驗(yan)方案設(she)(she)(she)置的(de)(de)(de)設(she)(she)(she)定(ding)(ding):在試(shi)驗(yan)電壓項(xiang)中,按(an)確定(ding)(ding)單鈕,移動左右(you)光標到(dao)需要改(gai)變的(de)(de)(de)數(shu)(shu)(shu)位(wei),按(an)上下單鈕以改(gai)變當(dang)前數(shu)(shu)(shu)位(wei)的(de)(de)(de)數(shu)(shu)(shu)值(zhi)大小,觸按(an)返回鈕完(wan)成當(dang)前數(shu)(shu)(shu)位(wei)的(de)(de)(de)數(shu)(shu)(shu)值(zhi)設(she)(she)(she)定(ding)(ding),依次選擇(ze)下一(yi)項(xiang)數(shu)(shu)(shu)值(zhi)的(de)(de)(de)設(she)(she)(she)定(ding)(ding),直至分別(bie)完(wan)成試(shi)驗(yan)時間、起始(shi)頻率、起始(shi)功率的(de)(de)(de)設(she)(she)(she)置,方可(ke)完(wan)成本次試(shi)驗(yan)的(de)(de)(de)試(shi)驗(yan)方案設(she)(she)(she)置的(de)(de)(de)設(she)(she)(she)定(ding)(ding)。
出(chu)廠默認值:試驗電(dian)壓(ya) 20kV、加壓(ya)時間 2min、激(ji)勵強(qiang)度 2%、輸出(chu)電(dian)流20A、頻率(lv)范圍(wei)30-300Hz。
5、實(shi)用工具菜單下有
頻率(lv)計算:在實驗前可對諧振頻率(lv)進行計算。只需輸入具體參與試驗的電(dian)感、電(dian)容值并按確定鍵試驗頻率(lv)即直接生成。
6、開始試(shi)驗(yan)菜(cai)單(dan)下(xia)有(you)自動試(shi)驗(yan)模(mo)(mo)式(shi)和手動試(shi)驗(yan)模(mo)(mo)式(shi)兩(liang)種(zhong)子菜(cai)單(dan)可供選擇。
按確認鍵進入所(suo)選(xuan)試驗步驟(zou).
自動試驗模式的操作:選中自動試驗模式后,觸按菜(cai)單鈕進入正在(zai)(zai)自動尋找(zhao)諧(xie)(xie)(xie)振(zhen)點(dian)菜(cai)單項,裝(zhuang)置在(zai)(zai)設定(ding)的頻(pin)率(lv)范(fan)圍內自動尋找(zhao)諧(xie)(xie)(xie)振(zhen)點(dian)(如果(guo)被試品(pin)電(dian)容C和(he)電(dian)抗器電(dian)感(gan)L的實際諧(xie)(xie)(xie)振(zhen)頻(pin)率(lv)不在(zai)(zai)設定(ding)的頻(pin)率(lv)范(fan)圍內,將找(zhao)不到諧(xie)(xie)(xie)振(zhen)點(dian),此(ci)時根(gen)據(ju)需要調(diao)整頻(pin)率(lv)范(fan)圍或(huo)調(diao)整被試品(pin)回(hui)路的LC參數(shu))。當找(zhao)到諧(xie)(xie)(xie)振(zhen)點(dian)時,會有聲音提示。
找到諧(xie)振點后,裝(zhuang)置自動進(jin)入正(zheng)在自動升壓(ya)菜單項(xiang),當升到試驗(yan)電壓(ya)設定(ding)的電壓(ya)時,裝(zhuang)置停止(zhi)加壓(ya)。
當裝置(zhi)升到(dao)試(shi)驗(yan)電壓(ya)(ya)(ya)設定(ding)的(de)電壓(ya)(ya)(ya)時(shi),設備停(ting)止加(jia)壓(ya)(ya)(ya),自動進入(ru)正在加(jia)壓(ya)(ya)(ya)試(shi)驗(yan)菜單項(xiang),并(bing)(bing)自動記錄試(shi)驗(yan)的(de)加(jia)壓(ya)(ya)(ya)時(shi)間(jian)(jian),當加(jia)壓(ya)(ya)(ya)時(shi)間(jian)(jian)到(dao)達設定(ding)時(shi)間(jian)(jian)時(shi),設備逐步(bu)降壓(ya)(ya)(ya)退出試(shi)驗(yan),完成本次試(shi)驗(yan),進入(ru)試(shi)驗(yan)結束菜單項(xiang)。并(bing)(bing)可(ke)選擇(ze)保存試(shi)驗(yan)數據或(huo)打印試(shi)驗(yan)數據。
試(shi)(shi)驗(yan)時間的一行顯示末端,會顯示[一段]或[二段]或[三段]字樣,表示當前正(zheng)在進行的加壓試(shi)(shi)驗(yan)是預置的一段,二段或三段.
手動(dong)試驗(yan)(yan)(yan)模(mo)式的(de)操作:選(xuan)中(zhong)手動(dong)試驗(yan)(yan)(yan)模(mo)式后觸(chu)按確定鈕,進(jin)入(ru)正在試驗(yan)(yan)(yan)菜單項;手動(dong)按調(diao)(diao)頻(pin)(pin)鈕,對應的(de)光(guang)標隨之改(gai)變到輸出頻(pin)(pin)率(lv)(lv)(lv)項,可以通過(guo)上下(xia)左右鍵改(gai)變頻(pin)(pin)率(lv)(lv)(lv)大小(xiao)使其試驗(yan)(yan)(yan)電(dian)壓(ya)(ya)逐步(bu)升(sheng)高(gao),當升(sheng)到*高(gao)電(dian)壓(ya)(ya)時,繼續向(xiang)上或(huo)向(xiang)下(xia)調(diao)(diao)整頻(pin)(pin)率(lv)(lv)(lv)按鈕,直至試驗(yan)(yan)(yan)電(dian)壓(ya)(ya)開始下(xia)降;這時反調(diao)(diao)頻(pin)(pin)率(lv)(lv)(lv),試驗(yan)(yan)(yan)電(dian)壓(ya)(ya)又逐步(bu)回(hui)升(sheng),上下(xia)回(hui)調(diao)(diao)頻(pin)(pin)率(lv)(lv)(lv),從頻(pin)(pin)率(lv)(lv)(lv)的(de)高(gao)位(wei)到低位(wei)逐位(wei)調(diao)(diao)整*高(gao)電(dian)壓(ya)(ya)值時的(de)頻(pin)(pin)率(lv)(lv)(lv)就是當前的(de)諧(xie)振頻(pin)(pin)率(lv)(lv)(lv)。
找到諧振點后,手動按(an)電(dian)壓(ya)(ya)鈕,光(guang)標到了輸出(chu)功率(lv),隨之按(an)上下鍵增(zeng)加輸出(chu)功率(lv),試(shi)(shi)驗(yan)電(dian)壓(ya)(ya)也逐(zhu)(zhu)步(bu)升高,當(dang)升到試(shi)(shi)驗(yan)電(dian)壓(ya)(ya)設定電(dian)壓(ya)(ya)值(zhi)時(shi),裝置停(ting)止加壓(ya)(ya),并(bing)有屏幕顯示(shi)提示(shi)和聲(sheng)音提示(shi);自動進(jin)入正在加壓(ya)(ya)試(shi)(shi)驗(yan)菜(cai)單項,并(bing)自動記錄(lu)試(shi)(shi)驗(yan)的加壓(ya)(ya)時(shi)間(jian),當(dang)到達加壓(ya)(ya)時(shi)間(jian)設定時(shi)間(jian)時(shi),設備逐(zhu)(zhu)步(bu)降壓(ya)(ya)退出(chu)試(shi)(shi)驗(yan),完成本次試(shi)(shi)驗(yan),進(jin)入試(shi)(shi)驗(yan)結束菜(cai)單項。
注意:在(zai)(zai)調(diao)節(jie)(jie)頻率調(diao)整鈕的(de)(de)(de)過程(cheng)中,觸(chu)按左(zuo)(zuo)右鈕,可(ke)以(yi)改(gai)(gai)變頻率調(diao)節(jie)(jie)的(de)(de)(de)速(su)度實(shi)現(xian)粗(cu)細調(diao)的(de)(de)(de)切換(huan)。在(zai)(zai)調(diao)節(jie)(jie)電壓(ya)(ya)調(diao)整鈕的(de)(de)(de)過程(cheng)中,向下觸(chu)按左(zuo)(zuo)右鈕,可(ke)以(yi)改(gai)(gai)變電壓(ya)(ya)的(de)(de)(de)升降的(de)(de)(de)速(su)度實(shi)現(xian)粗(cu)細調(diao)的(de)(de)(de)切換(huan)。觸(chu)按調(diao)頻、調(diao)壓(ya)(ya)鈕,實(shi)現(xian)調(diao)頻與(yu)調(diao)壓(ya)(ya)間的(de)(de)(de)切換(huan)。
7、進入(ru)試驗記錄查(cha)詢菜單(dan)項,查(cha)詢以往和當前(qian)試驗數據(ju)(ju)。選(xuan)擇上下(xia)鍵翻(fan)看前(qian)一組數據(ju)(ju)后(hou)一組數據(ju)(ju);選(xuan)擇左右鍵可選(xuan)擇打印或刪除(chu)當前(qian)頁的內容。
125/456為試驗(yan)數(shu)據(ju)庫(ku)指針,分子是試驗(yan)數(shu)據(ju)的在數(shu)據(ju)庫(ku)的順序(xu)數(shu),分母是當前(qian)的數(shu)據(ju)總數(shu),*多可(ke)儲存999組試驗(yan)數(shu)據(ju)。
8、裝置和(he)(he)試驗狀態菜單(dan)提示:設備的使用和(he)(he)升壓(ya)(ya)和(he)(he)耐(nai)壓(ya)(ya)試驗過程中,如果(guo)出現影響試驗設備、被試驗設備以及(ji)操(cao)作人的**情(qing)況,設備可能出現自(zi)動保護(hu)轉臺,并在(zai)屏幕有相應的提示。
不(bu)(bu)能諧振(zhen)(zhen):如果(guo)諧振(zhen)(zhen)點不(bu)(bu)在諧振(zhen)(zhen)頻(pin)率設置的范圍內;系統連線(xian)不(bu)(bu)正確(que)等(deng)現象(xiang),裝(zhuang)置將找不(bu)(bu)到諧振(zhen)(zhen)點,這時裝(zhuang)置和試驗狀態菜單中的不(bu)(bu)能諧振(zhen)(zhen)項被反白(bai)并閃爍。
輸出(chu)保護(hu):如果裝(zhuang)置的(de)電(dian)源輸出(chu)電(dian)流大于(yu)輸出(chu)保護(hu)設定的(de)電(dian)流值,裝(zhuang)置自(zi)動保護(hu),這時裝(zhuang)置和試驗狀態菜單中的(de)輸出(chu)保護(hu)項被反白并(bing)閃爍。
試(shi)(shi)驗中止(zhi):如果在試(shi)(shi)驗升壓或加(jia)壓過程(cheng)出現閃絡現象,裝置自動保護(hu),這時裝置和試(shi)(shi)驗狀(zhuang)態菜單中的輸出保護(hu)項被反(fan)白并閃爍。
9、試(shi)驗(yan)幫助內容(rong)包括五(wu)大項(xiang)分(fen)(fen)別為:1.版本信(xin)息2.接線示意3.使用說明4.常見(jian)問(wen)(wen)題5.參考(kao)資(zi)料.如(ru)常見(jian)問(wen)(wen)題FAQ分(fen)(fen)五(wu)幅畫面顯示、各(ge)種被試(shi)品電(dian)力電(dian)纜、變壓器、發電(dian)機電(dian)容(rong)參數的查詢:
接線(xian)示(shi)意圖:
10、設(she)(she)備出(chu)廠(chang)參(can)數(shu)(shu)設(she)(she)置是生產廠(chang)家(jia)(jia)的(de)出(chu)廠(chang)設(she)(she)置參(can)術和校驗參(can)數(shu)(shu),不適當的(de)設(she)(she)置和修(xiu)改(gai)會影響設(she)(she)備性(xing)能和高壓試驗的(de)**性(xing),未經(jing)廠(chang)家(jia)(jia)授權密碼,無法修(xiu)改(gai)。
警(jing)告:正常試(shi)驗狀態下,按返回鍵即可中止(zhi)試(shi)驗。中止(zhi)或結束試(shi)驗后(hou),應分離刀閘切斷電(dian)源。在升壓(ya)或加壓(ya)過程中,非緊急情況(kuang),不要按下急停(ting)鍵。
六、本(ben)說明書的專屬名詞的定義
自動試驗:高壓試驗全過程由(you)主機按程序和預置參數(shu)自動完(wan)成。
自動調(diao)諧:調(diao)諧由主機按程序自動完成(cheng),升壓手動完成(cheng)。
手(shou)動試驗(yan):尋(xun)找諧振點和升壓均為手(shou)動,通過面板旋鈕完成。
系統參數設置(zhi)是指對設備部件參數的設置(zhi)。
試驗參數(shu)設置是指對試驗過程參數(shu)的設置。
試驗模式(shi)選擇是指對試驗模式(shi)的(de)選擇。
試驗結果查詢(xun)是(shi)指對試驗數(shu)據的查詢(xun)。
分(fen)壓(ya)器(qi)變比(bi)是指對分(fen)壓(ya)器(qi)的分(fen)壓(ya)比(bi)設置。
電(dian)抗(kang)器電(dian)感是指對(dui)電(dian)抗(kang)器電(dian)抗(kang)值的(de)設置。
激(ji)勵變(bian)變(bian)比(bi)是指對勵磁變(bian)壓器的變(bian)比(bi)設置。
設置電(dian)壓(ya)(ya)是高壓(ya)(ya)試驗時的(de)保護電(dian)壓(ya)(ya)設置。
試(shi)驗電(dian)壓(ya)是高壓(ya)試(shi)驗時的試(shi)驗電(dian)壓(ya)。
加壓時(shi)間是施加試驗電壓的時(shi)間。
激(ji)勵強度是指主(zhu)機(ji)電(dian)源輸出的大(da)小。
輸(shu)出電(dian)流是主機電(dian)源(yuan)的輸(shu)出電(dian)流。
頻(pin)(pin)率范(fan)圍是(shi)試驗的頻(pin)(pin)率范(fan)圍。
自(zi)(zi)動試(shi)驗模式是指試(shi)驗過程全部(bu)自(zi)(zi)動完成。
自(zi)動(dong)調諧模(mo)式是(shi)指自(zi)動(dong)尋找(zhao)諧振(zhen)點后,手動(dong)加壓完(wan)成試驗。
手動試(shi)驗模(mo)式(shi)全(quan)部由人工完成試(shi)驗過程。
未接(jie)地線主機電源(yuan)為接(jie)地。
不能(neng)諧(xie)振未能(neng)找到諧(xie)振點。
輸出保護主機電(dian)源(yuan)輸出電(dian)流大于整定(ding)電(dian)流。
試驗中止指在升(sheng)壓(ya)或加壓(ya)過(guo)程(cheng)裝置自動保護。
設備出廠參數設置是廠家對(dui)設備有(you)關(guan)參數的(de)設置。
確(que)認(ren)鍵:確(que)認(ren)當前操作。
返(fan)回(hui)鍵:返(fan)回(hui)上(shang)**菜單。
七(qi)、變頻電源技術參數:
1.額定輸出容量:15kvA;
2.儀器電源:220v±10% 50Hz;
功率電源:380v±10% 50Hz;
3.額(e)定輸入電流:39.5A;
4.額定(ding)輸出電壓:0-340v可調(diao)、單相、輸出電壓不(bu)穩定(ding)度0.05%;
5.額定輸出電(dian)流:44A;
6.頻率調節(jie)范圍:25~320Hz;
7.額定容量下連(lian)續運行為(wei)規定工作時間下*高溫(wen)升≤60K;
8.顯示以(yi)下參數:
a.經變頻輸出的頻率、電(dian)壓、電(dian)流;
b.過壓保(bao)護(hu)電(dian)(dian)壓值,并可任意整(zheng)定,當(dang)成(cheng)套裝(zhuang)置(zhi)的輸出電(dian)(dian)壓值達到保(bao)護(hu)整(zheng)定時,可自(zi)動切除成(cheng)套裝(zhuang)置(zhi);
c.過流保護(hu):當調頻電源的輸出電流達到保護(hu)整定值時,可自動切除成(cheng)套裝置;
d.擊穿(chuan)保(bao)(bao)護(hu):當高壓側發(fa)生對地閃絡時,可自動切除成(cheng)套(tao)裝置(zhi)(zhi),裝置(zhi)(zhi)帶有隔離裝置(zhi)(zhi),可確(que)保(bao)(bao)設備和(he)人身不(bu)受損害;
e.具有全電(dian)壓(ya)輸出保護,在調壓(ya)過程中,一旦(dan)調壓(ya)失控(kong),調頻(pin)電(dian)源立即閉(bi)鎖;
9.可(ke)實現以下操作:
a.頻(pin)(pin)率(lv)的調(diao)節,上升和下降頻(pin)(pin)率(lv)調(diao)節分粗調(diao)和細(xi)調(diao)兩種,并(bing)可自動(dong)尋找試驗(yan)諧振點,保證諧振頻(pin)(pin)率(lv)在整個試驗(yan)過(guo)程中(zhong)不發生漂移(yi);
b.帶有(you)設(she)置電壓、設(she)置時間,電壓自動(dong)上升到設(she)置值而停止并自動(dong)計(ji)時;
c.帶有各種保(bao)護功能的整定(ding)按鈕,可在面板上對各種保(bao)護值進行(xing)整定(ding);
d.帶(dai)有(you)手動試驗功(gong)能(neng)和自動試驗功(gong)能(neng);
e.帶有試驗數(shu)據打印功能。
八(ba)、勵磁變(bian)壓器技術參數:
1.結構形式:干式;
2.額定(ding)容量:15kVA;
3.輸入電壓:0~340V;
4.輸出電(dian)壓:四(si)組(zu)并聯3.75KV;四(si)組(zu)串聯15KV;二串二并7.5KV;
5.輸出電流:四組(zu)并(bing)聯(lian)4A;四組(zu)串(chuan)聯(lian)1A;二(er)串(chuan)二(er)并(bing)2A;
6.工作頻率范(fan)圍:30~300Hz;
勵磁變壓器(qi)的接線端子,如圖所示:
1.輸出端(duan)尾(wei)—與接地端(duan)連接。
2.輸(shu)出端頭—與電抗器連接。
3.接地端—與變(bian)頻(pin)電源、分壓器及被試品(pin)共同接地。
4.輸入(ru)端—接調頻電源功(gong)率輸出端。
九、諧(xie)振電抗器技術(shu)參(can)數:
額定(ding)容量:55KVA;
額定電(dian)壓:55kV;
額(e)定電流:1.5A;
電(dian) 感 量(liang):160H;
品(pin)質因數:Q≥30
采用環氧干式。
7.接線端了如圖所示:
a.高壓側接(jie)線端(duan)子—與被(bei)試(shi)品高壓端(duan)連接(jie)。
b.低壓側接線端(duan)子—與勵(li)磁(ci)變輸出端(duan)連接。
c.多(duo)(duo)臺電(dian)抗器串聯時上(shang)節(jie)的(de)(de)低壓側與下節(jie)高壓側連(lian)接。諧振電(dian)抗器采用多(duo)(duo)臺串聯或并(bing)聯的(de)(de)連(lian)接方式。
8.額定(ding)容量下(xia)連續運行為規(gui)定(ding)工(gong)作(zuo)時間下(xia),電抗(kang)器(qi)對空(kong)氣(qi)的溫升不大(da)于60K;
9.性能(neng)及特點:電抗器(qi)設計干式、環氧澆鑄,電抗器(qi)可以自由方便疊裝。環氧樹脂(zhi)絕緣(yuan)筒外殼,具有(you)足夠的電氣、機(ji)械強(qiang)度,必(bi)要的散(san)熱(re)能(neng)力以及油熱(re)脹冷縮的裕度。外殼上下蓋板,顏(yan)色為橘紅色。
十、電容分壓器技(ji)術參數(shu):
額定電壓(ya):200kV;
工(gong)作頻率(lv):30~300Hz;
分壓比:2000:1;
分(fen)壓(ya)比誤差(cha):1%;
電容分壓(ya)器接線(xian)端子如圖所示:
高壓端—與(yu)電(dian)抗器高壓側及被試(shi)品高壓側相連。
測(ce)量(liang)插座(zuo)—采用專配的(de)測(ce)量(liang)電(dian)纜與控(kong)制箱背板測(ce)量(liang)輸入端連接。
接地端—采用(yong)專(zhuan)配接地線按接線圖指示接地。
4.性能及(ji)特點:
a.額定電壓下可連(lian)續運行2小時。
b.在30~300Hz范圍內,其(qi)精度和穩定度保(bao)持不(bu)變(bian)。
c.在20℃溫度(du)下電容分壓器介質損耗值≤0.0025
d.電容分壓器配有(you)支(zhi)撐(cheng)底架,具有(you)足夠的穩定性。
e.電(dian)(dian)壓測(ce)量(liang)通(tong)過專用測(ce)試引線引至調頻電(dian)(dian)源進行(xing)測(ce)量(liang)。
試(shi)驗接線圖:
110kv主變、GIS試驗(yan)接線
35kv電纜試驗接線圖
10kv電纜(lan)試驗接線圖
十二、設備(bei)保存和維護
1、存放于干燥(zao)、清潔場地,防止雨水、灰塵(chen)進入部件(jian)內部;
2、如若長(chang)期不使用(yong),正(zheng)常(chang)天氣至少(shao)(shao)2個月(yue)應通電(dian)一(yi)次(ci)時(shi)間不少(shao)(shao)于半小時(shi),雨季及潮濕期應每隔一(yi)個月(yue)通電(dian)一(yi)次(ci),通電(dian)時(shi)間半小時(shi),以(yi)驅除設(she)備內的潮氣防止電(dian)子元器件的銹蝕(shi),影(ying)響正(zheng)常(chang)使用(yong)。
3、定期檢查裝置各(ge)部(bu)件,確保各(ge)接(jie)頭緊固(gu)無松動;
4、更換打印紙(zhi),機器采用熱(re)敏(min)打印紙(zhi)并(bing)且是(shi)前換紙(zhi)式當需要(yao)換紙(zhi)時只要(yao)按POST鍵鈕打印紙(zhi)艙門就會打開可以將(jiang)新打印紙(zhi)裝入;
十三、常見故(gu)障排除
故障現象
|
發 生 原 因
|
排(pai) 除(chu) 方 法
|
找不到諧(xie)振點
|
接線有誤。
輸(shu)出(chu)開(kai)關未開(kai),;
3、做GIS時PT二(er)次回路未(wei)打開;
4、試品Q值太(tai)低;
5、起始激(ji)勵功率(lv)太低;
6、試驗回(hui)路有短路現象;
7、找頻范圍不對。
|
退出(chu)試(shi)驗狀態(tai),合(he)上輸出(chu)開關,檢查(cha)接線;打開PT二次回路;
調高起始功率(∠30%);
用(yong)兆歐表測量試品(pin)絕緣
重新設置找頻范圍(wei)
|
諧(xie)振(zhen)后,電壓升(sheng)不上去(qu)
|
1、試品Q值太低;
2、激(ji)勵電壓(ya)不夠;
3、電抗器底部有鐵磁(ci)物體;
4、3次諧(xie)波諧(xie)振。
|
檢查試品;
改變激勵變壓(ya)(ya)器繞(rao)組接法(fa),提高勵磁電壓(ya)(ya)
絕緣筒架(jia)高電抗器或離開鐵磁物體(ti)。
|
主機自動復位
|
供(gong)電(dian)電(dian)源容量(liang)不(bu)夠;
電源(yuan)引(yin)線過(guo)長或線徑過(guo)小;
接(jie)頭(tou)處接(jie)觸**;
供電電壓波動;
按鍵死(si)接觸。
|
增加供電電源容量;
換較粗導線,減小導線長度;
檢查接頭;
減(jian)小(xiao)供電(dian)電(dian)壓波(bo)動。
|
開(kai)機后線路(lu)跳閘
|
線路漏電保護器較為敏感;
空氣(qi)開(kai)關容量不夠。
|
跨過漏(lou)電(dian)保(bao)護器或空氣開(kai)關(guan)的接線;
改(gai)換較大容量的空氣開關。
|
電壓跌落
|
試品(pin)放電或擊(ji)穿
|
檢查試品
|
輸出短路
|
電流超過本機限流值。
|
檢查接線(xian)和(he)試品(pin)。
|
試(shi)品電(dian)壓不準
|
分(fen)壓比設置錯誤(wu)或分(fen)壓器信(xin)號(hao)傳輸有問(wen)題(ti)。
|
重設(she)分壓(ya)(ya)比或檢查分壓(ya)(ya)器(qi)接線。
|
電壓閃變(bian)
|
試驗電壓劇烈(lie)波動,變化(hua)率超過(guo)本機(ji)限定值。
|
檢(jian)查(cha)供電電源電壓穩定性或試品參(can)數的變化。
|
回路無(wu)電流
|
|
檢查接線(xian)和試品。
|
未接(jie)好地線
|
|
檢查(cha)接地線和地樁,按說明書要求連接。
|
試品(pin)過電壓
|
手動升壓太快(kuai)或失控。
|
改(gai)變(bian)調壓步距或改(gai)用自動升壓 。
|
系(xi)統不諧振
|
接線有誤或(huo)試(shi)品Q值(zhi)太低。
|
檢(jian)查接線和試品
|
十四(si)、常(chang)用(yong)設備資(zi)料參考(kao)
交聯聚乙烯電(dian)(dian)纜單位(wei)長度電(dian)(dian)容量
電纜導體截面積(ji)(平方毫米)
|
電 容(rong) (μ/km)
|
YJV、YJLV
|
YJV、YJLV
|
YJV、YJV、YJLV
|
YJV、YJLV
|
YJV、YJLV
|
6/6kV、6/10kV
|
8.7/10kV、8.7/15kV
|
12/35kV
|
21/35kV
|
26/35kV
|
1×35
|
0.212
|
0.173
|
0.152
|
|
|
1×50
|
0.237
|
0.192
|
0.166
|
0.118
|
0.114
|
1×70
|
0.270
|
0.217
|
0.187
|
0.131
|
0.125
|
1×95
|
0.301
|
0.240
|
0.206
|
0.143
|
0.135
|
1×120
|
0.327
|
0.261
|
0.223
|
0.153
|
0.143
|
1×150
|
0.358
|
0.284
|
0.241
|
0.164
|
0.153
|
1×185
|
0.388
|
0.307
|
0.267
|
0.180
|
0.163
|
1×240
|
0.430
|
0.339
|
0.291
|
0.194
|
0.176
|
1×300
|
0.472
|
0.370
|
0.319
|
0.211
|
0.190
|
1×400
|
0.531
|
0.418
|
0.352
|
0.231
|
0.209
|
1×500
|
0.603
|
0.438
|
0.388
|
0.254
|
0.232
|
1×600
|
0.667
|
0.470
|
0.416
|
0.287
|
0.256
|
2、交聯(lian)聚乙烯電(dian)纜單位長度(du)電(dian)容量
電纜導體截面積(ji)(平方毫米(mi))
|
電 容(rong) (μF/km)
|
YJV、YJLV
|
YJV、YJLV
|
YJV、YJV、YJLV
|
YJV、YJLV
|
YJV、YJLV
|
6/6kV、6/10kV
|
8.7/10kV、8.7/15kV
|
12/35kV
|
21/35kV
|
26/35kV
|
3×35
|
0.212
|
0.173
|
0.152
|
|
|
3×50
|
0.237
|
0.192
|
0.166
|
0.118
|
0.114
|
3×70
|
0.270
|
0.217
|
0.187
|
0.131
|
0.125
|
3×95
|
0.301
|
0.240
|
0.206
|
0.143
|
0.135
|
3×120
|
0.327
|
0.261
|
0.223
|
0.153
|
0.143
|
3×150
|
0.358
|
0.284
|
0.241
|
0.164
|
0.153
|
3×185
|
0.388
|
0.307
|
0.267
|
0.180
|
0.163
|
3×240
|
0.430
|
0.339
|
0.291
|
0.194
|
0.176
|
3×300
|
0.472
|
0.370
|
0.319
|
0.211
|
0.190
|
3×400
|
0.531
|
0.418
|
0.352
|
0.231
|
0.209
|
3×500
|
0.603
|
0.438
|
0.388
|
0.254
|
0.232
|
3×600
|
0.667
|
0.470
|
0.416
|
0.287
|
0.256
|
3、交聯聚(ju)乙烯電纜單位長(chang)度電容量
電纜導體截面(mian)積(平方毫米(mi))
|
電 容 (μF/km)
|
YJV、YJLV
|
YJV、YJLV
|
64/110kV
|
128/220kV
|
3×240
|
0.129
|
|
3×300
|
0.139
|
|
3×400
|
0.156
|
0.118
|
3×500
|
0.169
|
0.124
|
3×630
|
0.188
|
0.138
|
3×800
|
0.214
|
0.155
|
3×1000
|
0.231
|
0.172
|
3×1200
|
0.242
|
0.179
|
3×1400
|
0.259
|
0.190
|
3×1600
|
0.273
|
0.198
|
3×1800
|
0.284
|
0.297
|
3×2000
|
0.296
|
0.215
|
3×2200
|
|
0.221
|
3×2500
|
|
0.232
|
4、60kV級全(quan)絕緣變壓(ya)器的電容(pF)
類(lei) 型
|
變(bian) 壓 器 容(rong) 量(liang) kVA
|
630
|
2000
|
3150
|
6300
|
8000
|
1600
|
高壓(ya)-地
|
2700
|
4100
|
4600
|
5900
|
7000
|
8200
|
低壓-地
|
4200
|
6600
|
7900
|
10000
|
11000
|
15300
|
對于(yu)表中(zhong)沒有的(de)產品,可(ke)根據表中(zhong)的(de)上、下容量近似地估算。同容量的(de)雙(shuang)繞(rao)組變(bian)壓(ya)器,其繞(rao)組電容要比三(san)繞(rao)組產品小。
5、110kV級中性點分(fen)級絕緣變壓(ya)器的電容(pF)
類(lei) 型
|
變 壓(ya) 器 容 量kVA
|
50000
|
31500
|
20000
|
10000
|
5600
|
高壓-中壓、低壓、地
|
14200
|
11400
|
8700
|
6150
|
4200
|
中壓-高(gao)壓、低壓、地
|
24800
|
11800
|
13200
|
9600
|
-
|
低(di)壓-高壓、中壓、地
|
19300
|
19300
|
12000
|
9400
|
6800
|
6、220kV級中(zhong)性點非全級絕(jue)緣部分變壓器的電容(pF)
試 品(pin) 型 號
|
SEPSL-63000
|
SSPSL-120000
|
SSPSL-240000
|
類 型
|
高壓-中壓、低壓及地
|
12100
|
13500
|
17050
|
中壓(ya)(ya)-高壓(ya)(ya)、低壓(ya)(ya)及地
|
18500
|
19700
|
23260
|
低壓(ya)(ya)-高壓(ya)(ya)、中壓(ya)(ya)及地
|
18200
|
23600
|
29940
|
試 品 型 號
|
SFPL-240000
|
SFP-360000
|
SFPSZL-120000
|
類 型(xing)
|
高(gao)壓(ya)-中壓(ya)、低壓(ya)及地
|
32230
|
33910
|
38020
|
中壓(ya)-高壓(ya)、低壓(ya)及地
|
-
|
-
|
23260
|
低壓(ya)-高壓(ya)、中壓(ya)及(ji)地
|
22470
|
23790
|
22160
|
7、油(you)浸式電力變壓(ya)器交流(liu)試驗電壓(ya)
額(e)定電壓
(k V)
|
*高工作
電壓(ya)(k V)
|
線端交流試(shi)驗電壓值(kV)
|
中性點交流試驗電壓(ya)值(zhi)(kV)
|
全(quan)部更換繞(rao)組
|
部分(fen)更換繞組或交(jiao)接
|
全部更換繞(rao)組
|
部分更換繞組或(huo)交接
|
<1
|
≤1
|
3
|
2.5
|
3
|
2.5
|
3
|
3.5
|
18
|
15
|
18
|
15
|
6
|
6.9
|
25
|
21
|
25
|
21
|
10
|
11.5
|
35
|
30
|
35
|
30
|
15
|
17.5
|
45
|
38
|
45
|
38
|
20
|
23.0
|
55
|
47
|
55
|
47
|
35
|
40.5
|
85
|
72
|
85
|
72
|
110
|
126.0
|
200
|
170(195)
|
95
|
80
|
220
|
252.0
|
360
|
306
|
85
|
72
|
395
|
336
|
(200)
|
(170)
|
500
|
550.0
|
630
|
536
|
85
|
72
|
680
|
578
|
140
|
120
|
8、部分(fen)型號發(fa)電機(ji)定子繞組的單相對地電容量(liang)
類別
|
發 電 機
|
型(xing)號
|
生(sheng)產廠家
|
額定容量(liang)(MW)
|
額(e)定(ding)電壓(kV)
|
相(xiang)電(dian)容(rong)(mF)
|
火
力(li)
發
電
機
|
QFS-125-2
|
上海電機廠
|
125
|
13.8
|
0.08-0.12
|
QFSN-200-2
|
哈爾濱電機廠
|
200
|
15.75
|
0.19-0.21
|
QFQS-200-2
|
東方電機(ji)廠
|
200
|
15.75
|
0.1928-0.21
|
QFQS-200-2
|
北京(jing)重(zhong)型電機廠
|
200
|
15.75
|
0.18-0.19
|
QFS-300-2
|
上海電機廠(chang)
|
300
|
18.0
|
0.16-0.20
|
QFSN-300-2
|
上海(hai)電機廠
|
300
|
18.0
|
0.18-0.20
|
ATB-2
|
美國GE公司
|
352
|
23.0
|
0.268(設計值)
|
TBB-320-2
|
(前蘇聯(lian))
|
320
|
20.0
|
0.31
|
2-105×234
|
美(mei)國西屋公司(si)
|
600
|
20.0
|
0.2(工廠(chang)試驗值)
|
50WT23E-138
|
ABB
|
600
|
22.0
|
0.253(設(she)計值(zhi))
|
水 發
力 電
機
|
|
|
72.5 - 85
|
10.5
|
0.694
|
|
|
300
|
15.75
|
1.7-2.5
|
|
|
400
|
18.0
|
2-2.5
|
9、同步發電機定子繞組交(jiao)流試驗電壓
1
|
全部更換定子(zi)繞(rao)組并修好后(hou)的試驗(yan)電(dian)壓
|
容(rong)量kW或kVA
|
小(xiao)于10000
|
10000及(ji)以上
|
額定電壓(ya)Un (V)
|
36以(yi)上
|
6000以下
|
6000~18000
|
18000以上
|
試驗電(dian)壓V
|
2Un+1000但(dan)*低(di)為1500
|
2.5Un
|
2Un
+3000
|
按(an)專門協議
|
2
|
大修(xiu)前或局部(bu)更換(huan)定子繞組并(bing)修(xiu)好后的試驗(yan)電壓
|
運行20年及(ji)以(yi)下者
|
1.5 Un
|
運行(xing)20年以(yi)上與架空線路(lu)直(zhi)接連接者
|
1.5 Un
|
運行20年(nian)以上(shang)不(bu)與架空線路直接連接者
|
(1.3~1.5)Un
|
十五(wu)、設備成套性:
變頻電源(yuan) 1臺
勵磁變壓(ya)器 1臺
電抗器 4臺
電容分壓器(qi) 1臺
附(fu)件及測試線(xian) 1套
支(zhi)架 15KV 1只
均壓罩 200KV 2只
絕(jue)緣底板 2塊
一(yi)、產(chan)品概述
YDQC系列輕(qing)型交直流高(gao)壓(ya)(ya)(ya)試(shi)(shi)(shi)驗變(bian)壓(ya)(ya)(ya)器是(shi)在同類(lei)產(chan)品(pin)YDJ(G)型高(gao)壓(ya)(ya)(ya)試(shi)(shi)(shi)驗變(bian)壓(ya)(ya)(ya)器的基礎上,按試(shi)(shi)(shi)驗變(bian)壓(ya)(ya)(ya)器國家標準ZBK41006—89要求,經(jing)改進后生產(chan)的一種(zhong)(zhong)新(xin)型產(chan)品(pin),本系列產(chan)品(pin)具有體積小、重量輕(qing)、結構緊湊、功能齊(qi)全、使用(yong)方便等特點。實用(yong)于(yu)電(dian)力(li)、工礦(kuang)、科研等部門,對各種(zhong)(zhong)高(gao)壓(ya)(ya)(ya)電(dian)氣(qi)設備、電(dian)氣(qi)元件、絕(jue)緣材料進行工頻耐壓(ya)(ya)(ya)試(shi)(shi)(shi)驗和直流泄漏試(shi)(shi)(shi)驗,是(shi)高(gao)壓(ya)(ya)(ya)試(shi)(shi)(shi)驗中必不可少的儀器。
二、產品結構
YDQC系列輕型(xing)高(gao)壓(ya)試驗變壓(ya)器鐵(tie)芯(xin)為(wei)單框式。線(xian)圈采用同芯(xin)圓筒多層塔(ta)式結(jie)(jie)構,初級(ji)低壓(ya)繞組繞在(zai)鐵(tie)芯(xin)上,次(ci)級(ji)高(gao)壓(ya)繞組繞在(zai)低壓(ya)繞組外(wai)側,這種同軸布(bu)置減少了繞組間的藕合(he)損耗。高(gao)壓(ya)硅堆用特殊工藝(yi)封裝在(zai)套(tao)管內,產品的外(wai)殼(ke)制成與器芯(xin)配合(he)較佳的八(ba)角形結(jie)(jie)構,整體外(wai)型(xing)美觀大(da)方。其內外(wai)部結(jie)(jie)構見圖1。
1-均壓球;2-硅堆短(duan)路桿(gan);3-高(gao)壓套管;4-油閥;5-殼體(ti);6、7-調整電壓輸(shu)入a、x端(duan)子;8、9-儀表(biao)測量E、F端(duan)子;10-高(gao)壓尾X端(duan)子;11-變(bian)壓器(qi)(qi)外(wai)殼接地(di)端(duan);12-高(gao)壓輸(shu)出(chu)A端(duan)子;13-高(gao)壓整流硅堆;14-內部均壓環;15-變(bian)壓器(qi)(qi)鐵芯;16-初級低壓繞(rao)(rao)組;17-測量儀表(biao)繞(rao)(rao)組;18-二次級高(gao)壓繞(rao)(rao)組;19-變(bian)壓器(qi)(qi)油。
三、工作原理(li)
YDQC系列(lie)輕(qing)型高(gao)(gao)壓(ya)試(shi)(shi)驗變壓(ya)器(qi)(qi)為(wei)(wei)單相變壓(ya)器(qi)(qi),聯結(jie)組(zu)標號II。單臺高(gao)(gao)壓(ya)試(shi)(shi)驗變壓(ya)器(qi)(qi)的工(gong)作(zuo)過程,用交流220V(10KVA以(yi)上(shang)為(wei)(wei)380V)電(dian)壓(ya)接入電(dian)源控(kong)制(zhi)箱(臺),經電(dian)源控(kong)制(zhi)箱(臺)內自藕調(diao)(diao)壓(ya)器(qi)(qi)(50KVA以(yi)上(shang)調(diao)(diao)壓(ya)器(qi)(qi)外附)調(diao)(diao)節(jie)0~200V(10KVA以(yi)上(shang)0~400V)電(dian)壓(ya)至(zhi)試(shi)(shi)驗變壓(ya)器(qi)(qi)的初級繞組(zu),根據電(dian)磁感應原理,在試(shi)(shi)驗變壓(ya)器(qi)(qi)高(gao)(gao)壓(ya)繞組(zu)可獲得試(shi)(shi)驗所需的高(gao)(gao)電(dian)壓(ya)。其工(gong)作(zuo)原理圖見圖2所示。
1、單臺YDQC高壓試驗變壓器工(gong)作(zuo)原理示意(yi)圖(tu)
在試驗變壓(ya)器中:a、x為低壓(ya)輸入(ru)端(duan);A、X 為高壓(ya)輸出端(duan);E、F為儀表測量端(duan)。
2、單臺交直流兩用型高壓試驗變壓器工作原理見圖3。圖中所示:高壓套管內裝有高壓硅堆,串接在高壓回路中作高壓整流,以獲得直流高電壓。當用一短路桿將高壓硅堆短接時,可獲得交流高電壓,其狀態為交流輸出;反之在抽出短路桿時,其狀態為直流輸出。
3、三臺高壓試驗變壓器串激獲得更高電壓原理見圖4,串激高壓試驗變壓器有很大的優越性,因為整個試驗裝置由多個單臺串激式試驗變壓器組成,單臺試驗變壓器有著體積小、重量輕、便于運輸的特點,它既可以串接成高出幾倍的單臺試驗變壓器輸出電壓組合使用,又可以分開單獨使用。整套試驗裝置投資小、經濟實惠。圖3所示:在三臺串激式試驗變壓器串激使用中,單臺試驗變壓器B1、B2、B3的輸出電壓都是U,**、二級的試驗變壓器內部都有一個激磁繞組,分別為A1、C1 和A2、C2。當控制電壓加在第**試驗變壓器B1的初級繞組a1、x1上,激磁繞組A1、C1給予試驗變壓器B2初級繞組供電,**級試驗變壓器B2的激磁繞組A2、C2給試驗變壓器B3的初級繞組供電。由于第**試驗變壓器B1的高壓尾及殼體接地,**、三級的試驗變壓器B2和B3對地有絕緣支架的隔離,這樣試驗變壓器B1、B2、B3對地輸出電壓分別為1U、2U、3U。
B1、B2、B3- 串激式高壓變壓器;1U、2U、3U-各級對(dui)地(di)電壓;
PV- 高壓示值(zhi)表(KV); ZJ1、ZJ2-絕緣支架。
四、使用方法及注意(yi)事項(xiang)
1、YDQC高(gao)壓(ya)試(shi)(shi)驗變(bian)壓(ya)器做(zuo)工頻(pin)耐壓(ya)試(shi)(shi)驗使(shi)用接(jie)線方法見圖(tu)5。做(zuo)工頻(pin)耐壓(ya)試(shi)(shi)驗前,先根據試(shi)(shi)驗變(bian)壓(ya)器的額定容(rong)(rong)量(liang)選擇好(hao)(hao)限流電(dian)阻,(水電(dian)阻)的阻值,再根據被試(shi)(shi)品需加(jia)的高(gao)壓(ya)電(dian)壓(ya)值調整(zheng)好(hao)(hao)放電(dian)球隙的球間距,為(wei)了提(ti)高(gao)對(dui)被試(shi)(shi)品施加(jia)電(dian)壓(ya)的測(ce)量(liang)精度,應(ying)在高(gao)壓(ya)側接(jie)入(ru)FRC阻容(rong)(rong)分(fen)壓(ya)器來(lai)測(ce)量(liang)電(dian)壓(ya)。
R1、R2- 限流電阻(zu); Qx- 放電球隙; Zx- 被試品(pin);
FRC- 阻容分壓器; V- 分壓器高壓表。
按照圖4、結合圖2所進行的工頻耐壓試驗接好工作線路,試驗變壓器的高壓繞阻的X端(高壓尾)、儀表測量繞組的F端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
用三臺試驗變壓器串激做工頻耐壓試驗時、**、三級試驗變壓器的初級繞組X端,儀表測量繞組的F端,以及高壓繞組的X端(高壓尾)均接本級試驗變壓器的外殼,**、三級試驗變壓器的主體必須放置在絕緣支架上。除第**以外、**、三級試驗變壓器的主體不要接地線。其接線方式見圖3所示。
接電源前,電源控制箱(臺)的調壓器必須調到零位。接通電源后,綠色指示燈亮,按一下啟動按鈕,紅色指示燈亮,表示試驗變壓器已接通控制電源,開始升壓。
從零位開始按順時針方向勻速旋轉調壓器手輪升壓。(升壓方式有:快速升壓法,即20S逐級升壓法,慢速升壓法,即60S逐級升壓法,極慢速升壓法供選用)電壓從零開始按選定的升壓速度升到您所需額定試驗電壓的75%后,再以每秒2%額定試驗電壓的速度升到您所需試驗電壓,并密切注意測量儀表的指示以及被試品的情況,被試品施加電壓的時間到后。應在數秒內勻速將調壓器返回,高壓降至1/3試驗電壓以下,按一下停止按鈕,高壓、低壓輸出停止,然后切斷電源線,試驗完畢。
工頻耐壓試驗操作過程注意事項
1、試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
2、被試品主要部位應**干凈,保持**干燥,以免損壞被試品和帶來試驗數值的誤差。
3、對大型設備的試驗,一般都應先進行試驗變壓器的空升試驗,即不接試品時升壓至試驗電壓,以便校對好儀表的指示精度,調整好放電球隙的球間距。
4、做耐壓試驗時升壓速度不能過快,并防止突然加壓,例如調壓器不在零位的突然合閘,也不能突然斷電,一般應在調壓器降至零位時分閘。
5、在升壓或耐壓試驗過程中,如發現下列不正常情況,1 電壓、電流表指針擺動很大,2 被試品發出不正常響聲,3 發現絕緣有燒焦或冒煙現象,應立即降壓,切斷電源,停止試驗并查明原因。
6、使用本產品做高壓試驗時,除熟悉本說明書外,還必須嚴格執行國家有關標準和操作規程。
2、YDQ交直流(liu)(liu)(liu)兩用(yong)高(gao)(gao)(gao)(gao)壓(ya)(ya)試驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)器(qi)做直流(liu)(liu)(liu)耐(nai)壓(ya)(ya)和泄漏試驗(yan)(yan)使(shi)用(yong)接線方法見圖5。由于是交直流(liu)(liu)(liu)兩用(yong)高(gao)(gao)(gao)(gao)壓(ya)(ya)試驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)器(qi),應把高(gao)(gao)(gao)(gao)壓(ya)(ya)硅堆短(duan)路桿(gan)從(cong)套管中(zhong)抽出,使(shi)試驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)器(qi)為(wei)直流(liu)(liu)(liu)輸(shu)出狀(zhuang)態。做直流(liu)(liu)(liu)泄漏試驗(yan)(yan)前,先根據(ju)泄漏試驗(yan)(yan)中(zhong)輸(shu)出端(duan)斷(duan)路電(dian)(dian)流(liu)(liu)(liu)不超過高(gao)(gao)(gao)(gao)壓(ya)(ya)硅堆的(de)*大(da)整流(liu)(liu)(liu)為(wei)宜,選擇好限流(liu)(liu)(liu)電(dian)(dian)阻(zu)(水電(dian)(dian)阻(zu))的(de)阻(zu)值(zhi),再根據(ju)被(bei)試品對直流(liu)(liu)(liu)高(gao)(gao)(gao)(gao)壓(ya)(ya)波形的(de)要求選擇好高(gao)(gao)(gao)(gao)壓(ya)(ya)濾波電(dian)(dian)容(rong)的(de)電(dian)(dian)容(rong)值(zhi)。為(wei)了(le)提高(gao)(gao)(gao)(gao)對被(bei)試品施加(jia)電(dian)(dian)壓(ya)(ya)的(de)測量精(jing)度,應在高(gao)(gao)(gao)(gao)壓(ya)(ya)側接入(ru)FRC阻(zu)容(rong)分(fen)壓(ya)(ya)器(qi)來測量電(dian)(dian)壓(ya)(ya)。
R- 限流電阻; C- 高壓濾波電容; Zx- 被試品; G- 硅堆短(duan)路(lu)桿;
FRC- 阻容分壓器;V- 分壓器高壓表;uA- 微安表;D- 高壓整流硅堆。
按照圖5、結合圖3所進行的直流泄漏試驗接好工作線路。試驗變壓器的高壓繞組的X端(高壓尾)、儀表測量繞組的F 端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
接電(dian)(dian)源(yuan)前、電(dian)(dian)源(yuan)控(kong)制箱(xiang)(臺)的調(diao)壓(ya)(ya)器必須調(diao)到零位(wei)。接通電(dian)(dian)源(yuan)后,綠(lv)色指示(shi)燈亮,按(an)(an)一(yi)下啟動(dong)按(an)(an)鈕,紅色指示(shi)燈亮,表示(shi)試驗變壓(ya)(ya)器已接通控(kong)制電(dian)(dian)源(yuan),開始升壓(ya)(ya)。
從零位開始按順時(shi)針方向勻(yun)速(su)旋轉調(diao)壓(ya)器手輪升(sheng)(sheng)壓(ya)。(升(sheng)(sheng)壓(ya)方式有:快速(su)升(sheng)(sheng)壓(ya)法(fa)即(ji)20S逐(zhu)級(ji)(ji)升(sheng)(sheng)壓(ya)法(fa);慢速(su)升(sheng)(sheng)壓(ya)法(fa),即(ji)60S逐(zhu)級(ji)(ji)升(sheng)(sheng)壓(ya)法(fa);級(ji)(ji)慢速(su)升(sheng)(sheng)壓(ya)法(fa)供選(xuan)用)電(dian)壓(ya)從零開始按選(xuan)定的升(sheng)(sheng)壓(ya)速(su)度升(sheng)(sheng)到您(nin)所需額定試(shi)(shi)(shi)(shi)驗(yan)電(dian)壓(ya)或額定直(zhi)流(liu)(liu)電(dian)流(liu)(liu)下(xia)的參考(kao)電(dian)壓(ya)。試(shi)(shi)(shi)(shi)驗(yan)中應(ying)嚴(yan)密(mi)注(zhu)意(yi)直(zhi)流(liu)(liu)高(gao)(gao)壓(ya)表、泄漏電(dian)流(liu)(liu)表指示以及(ji)被試(shi)(shi)(shi)(shi)品(pin)的情況(kuang)。試(shi)(shi)(shi)(shi)驗(yan)完畢后(hou),應(ying)訊(xun)速(su)均勻(yun)將(jiang)高(gao)(gao)壓(ya)降至零位,按一下(xia)停(ting)止按鈕,高(gao)(gao)壓(ya)、低(di)壓(ya)輸(shu)出停(ting)止,然后(hou)切斷電(dian)源。此(ci)時(shi)應(ying)用直(zhi)流(liu)(liu)高(gao)(gao)壓(ya)放**給被試(shi)(shi)(shi)(shi)品(pin)及(ji)試(shi)(shi)(shi)(shi)驗(yan)裝置本身(shen)充分放電(dian)。
直流泄漏(lou)試驗(yan)操作過程注意事項
(1)試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
(2)被試品做試驗前,應拆除所有對外連線,并充分放電,主要部位應**干凈,保持**干燥,以免損壞被試品及帶來試驗數值的誤差。
(3)對于大容量試品(電容器、超長電纜等)試驗時應緩慢升壓,防止被試品的充電電流過大而燒壞微安表,必要時應分級加壓分別讀取各電壓下微安表的穩定讀數。
(4)試驗過程中,應嚴密監視被試品、微安表及試驗裝置等,一旦發生閃爍、擊穿等現象應立即降壓,切斷電源,并查明原因。
五(wu)、配套選購產品
下列產品僅供選擇,購買時需另行計價。
1.KZX系列電源控制箱 容量:1KVA-5KVA、輸入電壓:220V
2.KZT系列電源控制臺 容量:10KVA~300KVA輸入電壓:220V或380V
3.數字微安表:SWB-II
4.高壓濾波電容: 0.01MF、40 ~ 100KV
5.高壓直流放**: FBR— 70、140、210KV
6.放電球隙: Q—50、100、150、200、250、500
7.標準試油杯: 400ml
8.折疊式手推車: 150、300型
9.絕緣支架: 50、100、200、300、400KV
10.阻容分壓器: FRC —50、100、150、200KV
11.高壓硅堆: 2DL—150、300、450KV
12.水 電 阻: 50、100
六、主要試驗設備的(de)選擇
1、試驗變壓器
其高壓側額定電壓應不小于被試品的*高試驗電壓,額定電流不小于被試品的*大電容電流。被試品的電容電流和試驗變壓器所需容量計算式為:
被試品(pin)電(dian)容量Cx可(ke)由交流電(dian)橋(qiao)測出。常用的被試品(pin)電(dian)容量按表1選取。
幾種常用被試品的(de)電容量(pF) 表1
2、調壓設(she)備
(1)自藕調壓器。其調壓范圍廣、功率損耗小、波形畸變小、選擇這種調壓方式為*好。自藕調壓器的容量按0.75 ~ 1倍的試驗變壓器的容量選擇,適用于容量為100KVA以下的試驗變壓器的調壓。
(2)感應調壓器。其調壓范圍大,波形畸形小、但結構復雜、價格較貴,當試驗變壓器的容量較大時(如100KVA以上)使用。
3、限流電阻
限流電阻的作用是,當被試品擊穿時,限制斷路電流,從而保護試驗變壓器,防止故障的擴大。其數值以*高試驗電壓為準,按0.5 ~ 1 Ω / V(有效值)選擇,限流電阻可用水電阻。注意水不能充滿玻璃管,應留有余地,以防爆裂。
4、放電球隙
放電球隙的布置方式有垂直和水平兩種,球隙間距S和球的直徑D的關系應保護在0.05D ≤S ≤0.5D范圍內,球隙上的水電阻阻值一般按0.1 ~ 1Ω/V選取,設置放電球隙的目的是為了對重要的被試品起保護作用,可以將由于誤操作或被試品擊穿引起的過電壓限制在允許的范圍內。
七、試驗變(bian)壓(ya)器技術指示
型號
|
容(rong)量
|
高壓(ya)電壓(ya)
|
高壓電流
|
低壓(ya)輸入(ru)
|
變比
|
溫升℃
|
(KVA)
|
(KV)
|
(mA)
|
電壓(V)
|
電流(A)
|
高/儀
|
30分鐘
|
YDQC-1.5/50
|
1.5
|
50
|
30
|
200
|
7.5
|
500
|
10
|
YDQC-3/50
|
3
|
50
|
60
|
200
|
15
|
500
|
10
|
YDQC-5/50
|
5
|
50
|
100
|
200
|
25
|
500
|
10
|
YDQC-10/50
|
10
|
50
|
200
|
200
|
50
|
500
|
10
|
YDQC-15/50
|
15
|
50
|
300
|
200
|
75
|
500
|
10
|
YDQC-20/50
|
20
|
50
|
400
|
380
|
53
|
500
|
10
|
YDQC-30/50
|
30
|
50
|
600
|
380
|
79
|
500
|
10
|
YDQC-50/50
|
50
|
50
|
1000
|
380
|
12
|
500
|
10
|
YDQC-5/100
|
5
|
100
|
50
|
200
|
25
|
1000
|
10
|
YDQC-10/100
|
10
|
100
|
100
|
200
|
50
|
1000
|
10
|
YDQC-20/100
|
20
|
100
|
200
|
400
|
50
|
1000
|
10
|
YDQC-30/100
|
30
|
100
|
300
|
400
|
75
|
1000
|
10
|
YDQC-50/100
|
50
|
100
|
500
|
400
|
125
|
1000
|
10
|
YDQC-20/150
|
20
|
150
|
133
|
400
|
50
|
1500
|
10
|
YDQC-30/150
|
30
|
150
|
200
|
400
|
75
|
1500
|
10
|
YDQC-50/150
|
50
|
150
|
333
|
400
|
125
|
1500
|
10
|
YDQC-100/150
|
100
|
150
|
667
|
400
|
250
|
1500
|
10
|
YDQC-50/200
|
50
|
200
|
250
|
400
|
125
|
2000
|
10
|
YDQC-100/200
|
100
|
200
|
500
|
400
|
250
|
2000
|
10
|
YDQC-150/200
|
150
|
200
|
750
|
400
|
375
|
2000
|
10
|
YDQC-200/200
|
200
|
200
|
1000
|
400
|
500
|
2000
|
10
|
YDQC-300/200
|
300
|
200
|
1500
|
400
|
600
|
2000
|
10
|
YDQC-50/300
|
50
|
300
|
170
|
400
|
125
|
3000
|
10
|
YDQC-100/300
|
100
|
300
|
333
|
400
|
250
|
3000
|
10
|
YDQC-150/300
|
150
|
300
|
500
|
400
|
375
|
3000
|
10
|
YDQC-200/300
|
200
|
300
|
667
|
400
|
500
|
3000
|
10
|
YDQC-300/300
|
300
|
300
|
3000
|
500
|
600
|
3000
|
10
|
1、使用環境條件
環境溫度不高于+40℃、不低于—20℃;空氣相對濕度不大于90%;海拔高度不超過2000米;
2、工作電壓
電源控制箱(臺)輸入電壓為工頻220V或380V、相對誤差不超過±10%;(具體使用電壓根據用戶所定試驗變壓器規格選取)
八、隨貨文件
YDQC 系列試驗變壓器產品說明書 1份
產品出廠試驗報告 1份
產品合格證 1份
裝箱單 1份
一、概述(shu)
YDQ系列(lie)高(gao)(gao)壓(ya)試驗(yan)(yan)(yan)變(bian)壓(ya)器(qi)(qi)是根據《試驗(yan)(yan)(yan)變(bian)壓(ya)器(qi)(qi)》標準(zhun),在(zai)油浸式(shi)試驗(yan)(yan)(yan)變(bian)壓(ya)器(qi)(qi)的(de)(de)(de)基礎(chu)上而設(she)計生產(chan)的(de)(de)(de)。SF6氣(qi)體具(ju)有良好的(de)(de)(de)電(dian)氣(qi)絕緣(yuan)性(xing)能及優異(yi)的(de)(de)(de)滅弧性(xing)能,其耐壓(ya)強(qiang)度(du)為同一壓(ya)力(li)下氮氣(qi)的(de)(de)(de)2.5倍(bei),擊穿(chuan)電(dian)壓(ya)的(de)(de)(de)空氣(qi)的(de)(de)(de)2.5倍(bei)。在(zai)0.25MPa下與油的(de)(de)(de)擊穿(chuan)電(dian)壓(ya)相等(deng),在(zai)0.45MPa壓(ya)力(li)下是油的(de)(de)(de)擊穿(chuan)電(dian)壓(ya)的(de)(de)(de)2倍(bei),是一種優于油的(de)(de)(de)新(xin)一代(dai)(dai)超高(gao)(gao)壓(ya)絕緣(yuan)介質材料(liao)。該產(chan)品技術要求完(wan)全符合《ZBK-41006-89》標準(zhun),它是油浸式(shi)輕型試驗(yan)(yan)(yan)變(bian)壓(ya)器(qi)(qi)的(de)(de)(de)換代(dai)(dai)產(chan)品。該產(chan)品具(ju)有體積小、重量輕、不受氣(qi)候變(bian)化影(ying)響、電(dian)暈小、現場搬(ban)運(yun)無需靜(jing)止可使用,使用壽(shou)命長、免維修等(deng)特點。適用于電(dian)力(li)系統、工(gong)礦(kuang)企業、科研部門等(deng)對各(ge)種高(gao)(gao)壓(ya)電(dian)氣(qi)設(she)備(bei)、電(dian)氣(qi)元件、絕緣(yuan)材料(liao)進行工(gong)頻或直流高(gao)(gao)壓(ya)下的(de)(de)(de)絕緣(yuan)強(qiang)度(du)試驗(yan)(yan)(yan)。
二(er)、產品結構
YDQ系列高(gao)壓試(shi)驗變壓器采用單(dan)框芯式鐵(tie)芯結(jie)構(gou),初級繞組(zu)繞在(zai)鐵(tie)芯上(shang),高(gao)壓繞組(zu)在(zai)外(wai)(wai),這種同軸布置(zhi)減少了漏磁通,因(yin)而增大了繞組(zu)間的(de)(de)耦合(he)。產品(pin)的(de)(de)外(wai)(wai)殼為(wei)圓柱灌式容器結(jie)構(gou),能(neng)耐受0.8MPa以上(shang)壓力。其結(jie)構(gou)見(jian)圖1:
三、工作(zuo)原理(li)
YDQ系列高(gao)壓(ya)(ya)(ya)試(shi)驗變(bian)壓(ya)(ya)(ya)器(qi)(qi)(qi)為單(dan)相變(bian)壓(ya)(ya)(ya)器(qi)(qi)(qi),聯結組標號(hao)Ⅰ.Ⅰ. 用工(gong)頻220V(10kVA以上為380V)電(dian)(dian)源接入 (為本公司生(sheng)產的試(shi)驗變(bian)壓(ya)(ya)(ya)器(qi)(qi)(qi)配套專用設(she)備,詳細資(zi)料請見其具體(ti)使用說明書)系列操(cao)作箱(xiang)(臺),經操(cao)作箱(xiang)內(nei)自偶調(diao)壓(ya)(ya)(ya)器(qi)(qi)(qi)(50kVA以上調(diao)壓(ya)(ya)(ya)器(qi)(qi)(qi)外附(fu))調(diao)節至0~200V(或0~400V)電(dian)(dian)壓(ya)(ya)(ya)輸出至YDQ試(shi)驗變(bian)壓(ya)(ya)(ya)器(qi)(qi)(qi)的初級繞組,根據電(dian)(dian)磁(ci)感(gan)應原理,在試(shi)驗變(bian)壓(ya)(ya)(ya)器(qi)(qi)(qi)高(gao)壓(ya)(ya)(ya)繞組可獲得試(shi)驗所(suo)需的高(gao)電(dian)(dian)壓(ya)(ya)(ya)。
單臺YDQ系列交直流高(gao)壓(ya)(ya)試驗(yan)變壓(ya)(ya)器(qi)的工作(zuo)原(yuan)理圖見(jian)圖3,圖中(zhong)高(gao)壓(ya)(ya)套管中(zhong)裝有(you)高(gao)壓(ya)(ya)硅堆,串(chuan)接(jie)在高(gao)壓(ya)(ya)回路(lu)(lu)中(zhong)作(zuo)半波整流,以獲得直流高(gao)電(dian)壓(ya)(ya)。當(dang)用一短路(lu)(lu)桿將高(gao)壓(ya)(ya)硅堆短接(jie)時,可獲得工頻高(gao)電(dian)壓(ya)(ya),作(zuo)為(wei)交流輸出(chu)狀態;取消短路(lu)(lu)桿時,作(zuo)為(wei)直流輸出(chu)狀態。
圖(tu)中:D—短路桿 VD—高(gao)壓硅堆(dui)
試驗變壓器高(gao)壓套管中的高(gao)壓硅(gui)堆未(wei)畫出,其原(yuan)理與上圖(tu)相(xiang)同(tong)。
三(san)臺(tai)(tai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)串級(ji)(ji)(ji)(ji)獲(huo)得(de)更高(gao)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)的接線原(yuan)理(li)見圖4。串級(ji)(ji)(ji)(ji)高(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)有很(hen)大的優越性,因為整個(ge)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)裝(zhuang)置(zhi)由幾臺(tai)(tai)單(dan)(dan)臺(tai)(tai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)組(zu)(zu)(zu)成,單(dan)(dan)臺(tai)(tai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)容量小(xiao)(xiao)、電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)低、重量輕,便于運輸和安裝(zhuang)。它既然可串接成高(gao)出幾倍的單(dan)(dan)臺(tai)(tai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)輸出電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)組(zu)(zu)(zu)合(he)使用(yong),又(you)可分(fen)(fen)開成幾套(tao)單(dan)(dan)臺(tai)(tai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)單(dan)(dan)獨使用(yong)。整套(tao)裝(zhuang)置(zhi)投(tou)資小(xiao)(xiao),經濟實惠。圖5中,在(zai)第**和**級(ji)(ji)(ji)(ji)的每個(ge)單(dan)(dan)元試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)中都(dou)有一個(ge)勵磁(ci)繞(rao)組(zu)(zu)(zu)A1、C1和A2、C2。在(zai)三(san)臺(tai)(tai)串級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)基本原(yuan)理(li)中,低壓(ya)(ya)(ya)(ya)(ya)(ya)電(dian)(dian)源加在(zai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)Ⅰ的初級(ji)(ji)(ji)(ji)繞(rao)組(zu)(zu)(zu)a1x1上(shang),單(dan)(dan)臺(tai)(tai)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)Ⅰ、Ⅱ、Ⅲ的輸出電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)都(dou)是(shi)V。勵磁(ci)繞(rao)組(zu)(zu)(zu)A1、C1給(gei)(gei)**級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)Ⅱ的初級(ji)(ji)(ji)(ji)繞(rao)組(zu)(zu)(zu)供電(dian)(dian);**級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)Ⅱ的勵磁(ci)繞(rao)組(zu)(zu)(zu)A2、C2給(gei)(gei)第三(san)級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)Ⅲ的初級(ji)(ji)(ji)(ji)繞(rao)組(zu)(zu)(zu)供電(dian)(dian)。**級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)Ⅱ和第三(san)級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)Ⅲ的箱(xiang)體分(fen)(fen)別處(chu)在(zai)對地為1V和2V的高(gao)電(dian)(dian)位上(shang),所以箱(xiang)體對地是(shi)絕緣的,試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)Ⅰ的箱(xiang)體是(shi)接地的。這樣第**、**級(ji)(ji)(ji)(ji)、第三(san)級(ji)(ji)(ji)(ji)試(shi)(shi)(shi)(shi)驗(yan)(yan)(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(qi)對地的額定輸出電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)分(fen)(fen)別為1V、2V、3V;其額定容量分(fen)(fen)別為3P、2P、1P。
YDQ系列高壓(ya)試(shi)驗(yan)變壓(ya)器做(zuo)被試(shi)品的工頻耐壓(ya)試(shi)驗(yan)使用接線原理(li)圖見圖5。
圖中(zhong):R1—限(xian)流電(dian)阻(zu) FRC—阻(zu)容分(fen)壓器 RF—球間隙(xi)保護電(dian)阻(zu) G—球間隙(xi) CX—被(bei)試品
注:高壓尾必須可靠接地
工頻耐壓(ya)(ya)(ya)試驗(yan)中限(xian)流電(dian)(dian)(dian)阻(zu)R1應根據試驗(yan)變壓(ya)(ya)(ya)器(qi)的額(e)定(ding)容(rong)量來(lai)選擇(ze)。如高(gao)壓(ya)(ya)(ya)側額(e)定(ding)輸(shu)出(chu)電(dian)(dian)(dian)流在100~300mA時,可取0.5~1Ω/V(試驗(yan)電(dian)(dian)(dian)壓(ya)(ya)(ya));高(gao)壓(ya)(ya)(ya)側額(e)定(ding)輸(shu)出(chu)電(dian)(dian)(dian)流為(wei)1A以上時,可取1Ω/V(試驗(yan)電(dian)(dian)(dian)壓(ya)(ya)(ya))。常(chang)用(yong)水(shui)(shui)(shui)電(dian)(dian)(dian)阻(zu)作為(wei)限(xian)流電(dian)(dian)(dian)阻(zu),管(guan)(guan)子長度可按150kV/m考(kao)慮(lv),管(guan)(guan)子粗(cu)細應具(ju)有足夠的熱容(rong)量(水(shui)(shui)(shui)阻(zu)液配制方法:用(yong)蒸餾水(shui)(shui)(shui)加(jia)入適量硫酸(suan)銅配制成各種不同的阻(zu)值(zhi))。
球間(jian)隙(xi)及保(bao)護電(dian)阻:當電(dian)壓超過球間(jian)隙(xi)整定值時(shi)(一般取(qu)(qu)試驗(yan)電(dian)壓的(de)110%~120%),球間(jian)隙(xi)放電(dian),對被試品起到保(bao)護作(zuo)用。球間(jian)隙(xi)保(bao)護電(dian)阻可按1Ω/V(試驗(yan)電(dian)壓)選(xuan)取(qu)(qu)。
在工頻(pin)耐壓(ya)(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)中(zhong),低電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)側(ce)測(ce)量電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(儀表電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya))不是(shi)(shi)非常(chang)準確的(de),其(qi)原因(yin)是(shi)(shi)由于(yu)試(shi)(shi)驗(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器存(cun)在著漏(lou)抗(kang),在這個漏(lou)抗(kang)上(shang)(shang)必然存(cun)在著壓(ya)(ya)(ya)(ya)(ya)降或(huo)容(rong)升,使試(shi)(shi)品上(shang)(shang)的(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)低于(yu)或(huo)高(gao)于(yu)低壓(ya)(ya)(ya)(ya)(ya)側(ce)測(ce)量電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)表上(shang)(shang)反(fan)映(ying)出來的(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)。工頻(pin)耐壓(ya)(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)時,被試(shi)(shi)品上(shang)(shang)的(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)高(gao)于(yu)試(shi)(shi)驗(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器的(de)輸出電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya),也就是(shi)(shi)所謂(wei)容(rong)升現(xian)象。感應(ying)耐壓(ya)(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)時,試(shi)(shi)驗(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器的(de)漏(lou)抗(kang)必然存(cun)在著壓(ya)(ya)(ya)(ya)(ya)降。為(wei)了準確測(ce)量被試(shi)(shi)品上(shang)(shang)所施加的(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya),因(yin)此(ci)常(chang)在高(gao)壓(ya)(ya)(ya)(ya)(ya)側(ce)接入FRC阻容(rong)分壓(ya)(ya)(ya)(ya)(ya)器來測(ce)量電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(見圖(tu)5)。
工頻耐壓(ya)試(shi)驗操作(zuo)注意事項
1)試(shi)驗人(ren)員應做好分工(gong),明確相互(hu)間聯系(xi)方法。并(bing)有專(zhuan)門人(ren)監護現場**及觀察試(shi)品狀(zhuang)態。
2)被試(shi)品應先清掃干凈,并**干燥,以免(mian)損(sun)壞被試(shi)品和(he)試(shi)驗帶來的誤(wu)差。
3)對(dui)于大型(xing)試驗,一般都應先進行空升(sheng)試驗。即不接試品時(shi)升(sheng)壓(ya)至試驗電壓(ya),校(xiao)對(dui)各種表計,調整球間隙。
4)升壓速度不能太快,并必須防止突然(ran)加壓。例(li)如調壓器(qi)不在零位(wei)(wei)時(shi)突然(ran)合閘。也不能突然(ran)切(qie)斷電源,一(yi)般應(ying)在調壓器(qi)降(jiang)至(zhi)零位(wei)(wei)時(shi)拉閘。
5)當電壓升至試驗電壓時,開始計(ji)時,到(dao)1min后,迅(xun)速降壓到(dao)1/3試驗電壓以下時,才能拉開電源(yuan)。
6)在(zai)升壓(ya)或(huo)(huo)耐(nai)壓(ya)試(shi)驗過(guo)程中(zhong),如發現下列不(bu)正(zheng)常情況時,應立即(ji)降壓(ya),切斷電源。停止試(shi)驗并(bing)查(cha)明原因:①電壓(ya)表指針擺動(dong)很大(da);②發現絕緣燒焦(jiao)或(huo)(huo)冒煙(yan);③被試(shi)品(pin)內有不(bu)正(zheng)常的聲音。
7)耐壓試驗前后(hou)應(ying)測量絕緣電阻,檢查(cha)絕緣情況。
試驗(yan)(yan)變壓器在做被試品的直(zhi)流耐壓或泄露試驗(yan)(yan)時(shi)接線(xian)原理圖如圖6。
注(zhu):此試驗應(ying)先抽出短路桿“D”,圖6中所示。
圖中:VD—高壓(ya)(ya)硅堆 R1—限流電(dian)阻 C1—高壓(ya)(ya)濾波(bo)電(dian)容 FRC—阻容分壓(ya)(ya)器(qi) CX—被試品 μA—帶保(bao)護微(wei)安(an)表
泄露試驗(yan)(yan)中(zhong)限流(liu)(liu)電(dian)阻R1選(xuan)擇(ze)在額定輸出電(dian)壓(ya)(ya)時,輸出端短(duan)路(lu)電(dian)流(liu)(liu)不超過(guo)高壓(ya)(ya)硅堆的(de)(de)*大整(zheng)流(liu)(liu)。如電(dian)壓(ya)(ya)硅堆的(de)(de)*大整(zheng)流(liu)(liu)電(dian)流(liu)(liu)為(wei)100mA時用(yong)于60kV的(de)(de)試驗(yan)(yan)裝置中(zhong),限流(liu)(liu)電(dian)阻按R1=60/0.1=600kΩ選(xuan)擇(ze)。限流(liu)(liu)電(dian)阻還應具(ju)有足夠的(de)(de)容量(liang)和沿面放電(dian)距離。
高壓濾波電(dian)容C1一般選擇在0.01~0.1μF,當(dang)被試品的電(dian)容量很大(da)時,C1可省略不用。
泄露(lu)試驗的操作及注(zhu)意事(shi)項
1)試(shi)驗(yan)(yan)前應(ying)先檢查被試(shi)品是(shi)否停電(dian),接(jie)地放電(dian),一切對外連(lian)線(xian)是(shi)否擦(ca)干凈。要(yao)嚴防將試(shi)驗(yan)(yan)電(dian)壓(ya)加(jia)到有人工作(zuo)的部位上去。
2)接(jie)好試(shi)(shi)驗(yan)裝(zhuang)置的接(jie)線(xian)后,應復查無(wu)誤后才可加(jia)壓(ya)。應特(te)別(bie)注意檢(jian)查高壓(ya)設備及(ji)引(yin)線(xian)與(yu)地(di)、與(yu)操(cao)作(zuo)人(ren)員的**距離,被試(shi)(shi)品的外殼是否(fou)可靠接(jie)地(di),要按**規程中所規定(ding)的內容(rong)進(jin)行(xing)試(shi)(shi)驗(yan)。
3)對于大電容量設備應(ying)緩慢升(sheng)壓,防(fang)止被(bei)試品(pin)的充電電流燒壞微(wei)安(an)表。必要時(shi)應(ying)分級加壓,分別(bie)讀取各(ge)級電壓下微(wei)安(an)表的穩(wen)定讀數。
4)試驗過程中,應密切監視(shi)被試品(pin)、試驗裝(zhuang)置(zhi)、微安表(biao),一旦發生擊(ji)穿、閃(shan)爍等異(yi)常現象應立即降壓,切斷電源,并查明原因(yin),詳(xiang)細記(ji)錄。
5)試(shi)驗(yan)完(wan)畢,降(jiang)壓,切(qie)斷電源(yuan)后應將被試(shi)品及試(shi)驗(yan)裝置(zhi)本身(shen)充分放電。
四、注意事項
1、按照您所(suo)進行的試驗接好工作(zuo)線路。試驗變(bian)壓器的外(wai)殼(ke)以及操作(zuo)系統的外(wai)殼(ke)必(bi)須可靠(kao)接地。試驗變(bian)壓器高壓繞組的X端(高壓尾)以及測量(liang)繞組的F端必(bi)須可靠(kao)接地。
2、做串級(ji)(ji)(ji)試(shi)(shi)驗時(shi),**級(ji)(ji)(ji)、第三(san)(san)級(ji)(ji)(ji)試(shi)(shi)驗變壓(ya)器(qi)的(de)(de)低壓(ya)繞組的(de)(de)X端(duan),測量繞組的(de)(de)F端(duan)以(yi)及(ji)高壓(ya)繞組的(de)(de)X端(duan)(高壓(ya)尾(wei))均(jun)接本級(ji)(ji)(ji)試(shi)(shi)驗變壓(ya)器(qi)的(de)(de)外殼。**級(ji)(ji)(ji)、第三(san)(san)級(ji)(ji)(ji)試(shi)(shi)驗變壓(ya)器(qi)的(de)(de)外殼必須通(tong)過(guo)絕緣支架接地。
3、接通電(dian)源(yuan)前(qian),操作系統的調(diao)壓(ya)器必(bi)須調(diao)到零位后(hou)方可接通電(dian)源(yuan),合閘,開始升壓(ya)。
4、從(cong)零開(kai)始均(jun)勻(yun)旋轉調壓(ya)(ya)(ya)器手輪升(sheng)壓(ya)(ya)(ya)。升(sheng)壓(ya)(ya)(ya)方法(fa)有:快(kuai)速(su)升(sheng)壓(ya)(ya)(ya)法(fa),即(ji)(ji)20s逐(zhu)級升(sheng)壓(ya)(ya)(ya)法(fa);慢速(su)升(sheng)壓(ya)(ya)(ya)法(fa),即(ji)(ji)60s逐(zhu)級升(sheng)壓(ya)(ya)(ya)法(fa);極慢速(su)升(sheng)壓(ya)(ya)(ya)法(fa)供選用。電壓(ya)(ya)(ya)從(cong)零開(kai)始按一定(ding)的(de)升(sheng)壓(ya)(ya)(ya)方式和(he)速(su)度(du)上(shang)升(sheng)到(dao)您(nin)所需的(de)額(e)定(ding)試(shi)驗(yan)電壓(ya)(ya)(ya)的(de)75%后,在以每秒2%額(e)定(ding)試(shi)驗(yan)電壓(ya)(ya)(ya)的(de)速(su)度(du)升(sheng)到(dao)您(nin)所需的(de)額(e)定(ding)電壓(ya)(ya)(ya),并密(mi)切(qie)注(zhu)意測(ce)(ce)量儀(yi)表的(de)指示(shi)以及(ji)(ji)被試(shi)品的(de)情(qing)況。升(sheng)壓(ya)(ya)(ya)過程中或試(shi)驗(yan)過程中如(ru)發現測(ce)(ce)量儀(yi)表的(de)指示(shi)及(ji)(ji)被試(shi)品情(qing)況異常,應立即(ji)(ji)降壓(ya)(ya)(ya),切(qie)斷電源,查明情(qing)況。
5、試驗完畢后,應在數(shu)秒內勻速的將調壓器(qi)返回至零位,然后切斷電源。
6、本產品(pin)不得超過(guo)額(e)定參數使用。除(chu)試驗必(bi)須外,決不允許(xu)全電壓(ya)通電或(huo)斷電。
7、 再升壓或耐壓試(shi)(shi)驗過程中,如發現以(yi)下不(bu)正常情況時,應立即(ji)降壓,切斷電源,停止試(shi)(shi)驗并查(cha)明(ming)原因。
⑴電壓表指針擺動(或(huo)數字跳動)很大
⑵電流表直線上升
被試(shi)品內有不(bu)正常的聲音(yin)
8、圖1中(zhong)第9項(xiang)系(xi)壓力(li)閥(fa)及壓力(li)表,為長期關閉狀態(tai)。每6個(ge)月開閥(fa)一次,以(yi)檢查(cha)SF6壓力(li),應不小于(yu)(yu)0.2MPa(檢查(cha)壓力(li)后立(li)即關閉閥(fa)門),低于(yu)(yu)0.2MPa時應加SF6氣(qi)體,以(yi)增加氣(qi)絕緣。
9、耐壓實驗前(qian)后應測量(liang)被試設備(bei)的(de)絕(jue)緣電(dian)阻(zu),檢查(cha)絕(jue)緣情況。
10、當(dang)試驗變壓器(qi)長期不使用(yong)時,應放置于通風、干燥、無陽光直射的地方。
11、該產品不允許(xu)在高于45℃的溫(wen)度(du)下長期存放(fang)、使(shi)用、放(fang)氣(qi)。
12、運(yun)輸搬(ban)運(yun)途中不得重力沖擊。
13、產品緊固件及壓力閥、壓力表不得擅自松動。
14、使用本(ben)產品做高壓試驗(yan)時(shi),出熟悉本(ben)說明書外,還必(bi)須嚴格執行國家有關標準和操作規程(cheng)。可參照GB311-83《高壓輸變設(she)備(bei)的絕緣配合,高壓試驗(yan)技術》;《電氣(qi)設(she)備(bei)預防性試驗(yan)規程(cheng)》等。
五、試驗(yan)變壓器的容量選擇
標(biao)稱(cheng)試(shi)驗變壓器容量Pn的確定(ding)公式:Pn=kVn 2ωCt×10-9
式中(zhong):
Pn——標稱試驗變壓器(qi)容(rong)量(kVA)
Vn——試驗變壓(ya)器的(de)額定輸(shu)出(chu)高壓(ya)的(de)有效值(kV)
k ——**系(xi)數。k≥1,標稱電壓Vn≥1MV時,k=2;標稱電壓較低(di)時,k值可取高一(yi)些。
Ct——被(bei)試品的電容量(pF)
ω——角頻率,ω=2πf,f——試驗電源的頻率
被試設備的(de)電(dian)容(rong)量Ct可由交(jiao)流電(dian)橋測出。Ct的(de)變(bian)化很大,
可由設備的類(lei)型而定。
典(dian)型數據如(ru)下:
簡單的棒式(shi)或懸式(shi)絕緣子 幾十微法
簡單的(de)分級套管 100~1000pF
電壓(ya)互(hu)感器 200 ~ 500pF
電力變壓器 < 1000kVA~1000pF
> 1000kVA 1000~10000pF
高壓電力(li)電纜和油(you)浸紙絕(jue)緣(yuan) 250~300pF/m
氣體(ti)絕緣 ~60pF/m
封閉變(bian)電站,SF6氣(qi)體絕緣 100~10000Pf;
對于不同(tong)的(de)試驗電(dian)壓Vn,選擇(ze)不同(tong)的(de)(適當的(de))**系(xi)數k。
以下列出不同的Vn所選用的k值(zhi)供參考。
Vn =50~100kV k = 4
Vn =150~300kV k = 3
Vn > 300kV k = 2
一、概述
工頻耐壓試驗是(shi)鑒(jian)定(ding)電力設(she)備絕(jue)緣強(qiang)度的*嚴格、*有(you)效和*直(zhi)接的方法。它(ta)能檢查出那些(xie)危險性(xing)較大的集中(zhong)缺陷,對判斷電力設(she)備能否繼續參加運(yun)行(xing)具有(you)決(jue)定(ding)性(xing)作(zuo)用(yong),是(shi)保證設(she)備絕(jue)緣水平(ping)、避免發生絕(jue)緣事故的重要手(shou)段。
本裝置是根據國家*新電力行(xing)業(ye)標準而設(she)計的(de)(de)、性能先(xian)進的(de)(de)耐(nai)壓(ya)試驗設(she)備,用于對各(ge)種電器產(chan)(chan)品、電氣(qi)元件、絕(jue)緣(yuan)材料等進行(xing)規定(ding)電壓(ya)下的(de)(de)絕(jue)緣(yuan)強度試驗,以考核產(chan)(chan)品的(de)(de)絕(jue)緣(yuan)水(shui)平,發現被(bei)試品的(de)(de)絕(jue)緣(yuan)缺陷,衡量過電壓(ya)的(de)(de)能力。
二、產品特點
監視功(gong)能:高(gao)壓(ya)電壓(ya) 低壓(ya)電流 零位指(zhi)示(shi)(shi) 電源(yuan)指(zhi)示(shi)(shi) 工(gong)作指(zhi)示(shi)(shi) 計時指(zhi)示(shi)(shi)
保護功能:過流保護、零位啟動保護、聲光語(yu)言報警提醒(xing)
采用新型(xing)時(shi)間繼電器(qi),計時(shi)范圍更(geng)廣(1S~99H)
采用新型電流繼(ji)電器,更**、更可靠,確保人身(shen)及設備**。
試驗(yan)變壓器高壓線圈為圓筒多(duo)層塔式,由上等聚酯漆包線及(ji)高耐壓值絕(jue)緣材(cai)料繞制(zhi)而成。
試(shi)驗(yan)變壓器(5kVA以上)裝有可移(yi)動的鐵輪。具(ju)有重量輕(qing)、體積(ji)小、移(yi)動方(fang)便、性能優越等特點。
三、設備組成(cheng)
1、選型(xing)配置
標準配置
|
□ 分(fen)體式
|
操作部分:
□箱式(不大于5kVA) / □臺式
容量: kVA(小于(yu)200kVA)
輸入:□AC220V / □AC380V
|
試驗變壓器(qi):
□交流(liu) / □交直流(liu)
□油變 / □干變 / □氣變
容(rong)量(liang): kVA(小于200kVA)
輸出:AC kV(小于300kVA)
|
□ 一體(ti)式
|
□箱式(不(bu)大于(yu)20kV) / □臺式(不(bu)大于(yu)30kV)
容量: kVA(小于300kVA)
輸入:□AC220V / □AC380V 輸出:AC kV(不大于30kV)
|
客戶(hu)選配
|
□標準高壓分壓器(qi)
|
□保(bao)護(hu)球(qiu)隙
|
□直流(liu)微安(an)表(biao)
|
□放**
|
□保護水阻(zu)
|
□高壓(ya)濾(lv)波電容
|
其它:
|
2、對應實(shi)物
四(si)、技術指標
1、使用條件:
(1)工(gong)作(zuo)場所應(ying)無嚴(yan)重影響絕緣的(de)氣體、蒸汽(qi)、化學(xue)性塵(chen)埃及其(qi)它爆炸(zha)性和腐蝕性介質。
(2)環境溫度 -20~+50℃
(3)環境(jing)濕度(du) ≤85% RH(無(wu)凝結水(shui))
2、控制箱(臺)參數:(常規參數見下表)
規格(ge)
|
容量
|
輸 入(ru) 電(dian) 源
|
輸(shu) 出 電 壓
|
重量(kg)
|
相(xiang)數
|
(V)
|
(A)
|
(V)
|
(A)
|
2/220
|
2
|
1
|
220
|
10
|
0-250
|
8
|
14
|
3/220
|
3
|
1
|
220
|
15
|
0-250
|
12
|
16
|
5/220
|
5
|
1
|
220
|
25
|
0-250
|
20
|
18
|
10/220
|
10
|
1
|
220
|
50
|
0-250
|
40
|
80
|
15/380
|
15
|
2
|
380
|
37.5
|
0-430
|
34.8
|
90
|
20/380
|
20
|
2
|
380
|
50
|
0-430
|
46.5
|
100
|
25/380
|
25
|
2
|
380
|
62.5
|
0-430
|
58.1
|
120
|
30/380
|
30
|
2
|
380
|
75
|
0-430
|
69.7
|
140
|
50/380
|
50
|
2
|
380
|
125
|
0-430
|
116.2
|
160
|
100/380
|
100
|
2
|
380
|
250
|
0-430
|
232.5
|
250
|
說(shuo)明(ming):如有特殊參(can)數(shu)要(yao)求,可按用(yong)戶的技術(shu)參(can)數(shu)進行設(she)計制作。
3、試驗變壓器參數:(常規(gui)參數見下表)
規格(ge)
|
容量
kVA
|
低壓側(ce)
|
高壓側
|
高(gao)壓(ya)側(交直流變(bian)壓(ya)器)
|
測量變比
|
60分鐘(zhong)溫升℃
|
阻抗(kang)電壓%
|
空載電流(liu)
%
|
質量
kg
|
電壓
V
|
電流
A
|
交流輸出
|
直(zhi)流輸出
|
電壓kV
|
電流(liu)
|
電壓kV
|
電流
|
1.5/50
|
1.5
|
200
|
7.5
|
50
|
30
|
70
|
21.4
|
500
|
50
|
10
|
<4
|
19.5
|
3/50
|
3
|
200
|
15
|
50
|
60
|
70
|
42.9
|
500
|
50
|
10
|
<4
|
27
|
5/50
|
5
|
200
|
25
|
50
|
100
|
70
|
71.4
|
500
|
50
|
10
|
<4
|
52
|
10/50
|
10
|
200
|
50
|
50
|
200
|
70
|
142.9
|
500
|
50
|
10
|
<4
|
80
|
15/50
|
15
|
400
|
37.5
|
50
|
300
|
70
|
214.3
|
500
|
50
|
8
|
<4
|
120
|
20/50
|
20
|
400
|
50
|
50
|
400
|
70
|
285.7
|
500
|
50
|
8
|
<4
|
140
|
30/50
|
30
|
400
|
75
|
50
|
600
|
70
|
428.6
|
500
|
50
|
8
|
<4
|
155
|
50/50
|
50
|
400
|
125
|
50
|
1000
|
70
|
714.3
|
500
|
50
|
8
|
<4
|
184
|
10/100
|
10
|
200
|
50
|
100
|
100
|
140
|
71.4
|
1000
|
50
|
10
|
<4
|
135
|
15/100
|
15
|
400
|
37.5
|
100
|
150
|
140
|
107.1
|
1000
|
50
|
8
|
<4
|
150
|
20/100
|
20
|
400
|
50
|
100
|
200
|
140
|
142.9
|
1000
|
50
|
8
|
<4
|
215
|
30/100
|
30
|
400
|
75
|
100
|
300
|
140
|
214.3
|
1000
|
50
|
8
|
<4
|
250
|
50/100
|
50
|
400
|
125
|
100
|
500
|
140
|
357.1
|
1000
|
50
|
8
|
<4
|
290
|
10/150
|
10
|
200
|
50
|
100
|
66.7
|
140
|
47.6
|
1500
|
50
|
10
|
<4
|
180
|
15/150
|
15
|
400
|
37.5
|
150
|
100
|
210
|
71.4
|
1500
|
50
|
8
|
<4
|
200
|
20/150
|
30
|
400
|
50
|
150
|
133.3
|
210
|
95.2
|
1500
|
50
|
8
|
<4
|
220
|
30/150
|
30
|
400
|
75
|
150
|
200
|
210
|
142.9
|
1500
|
50
|
8
|
<4
|
280
|
50/150
|
50
|
400
|
125
|
150
|
333.3
|
210
|
238.1
|
1500
|
50
|
8
|
<4
|
340
|
說明:如有特殊參(can)數(shu)要求,可(ke)按用戶的(de)技術參(can)數(shu)進行設計制作。
上表的重量以油浸式(shi)試驗(yan)變(bian)(bian)壓器(qi)為例,干式(shi)試驗(yan)變(bian)(bian)壓器(qi)和充氣(qi)式(shi)試驗(yan)變(bian)(bian)壓器(qi)稍有(you)不(bu)同。
五、接線及工作原(yuan)理
1、調壓部分接線(xian)及(ji)原理
調壓(ya)(ya)部分(fen)由(you)控制(zhi)(zhi)部分(fen)和試驗(yan)變(bian)壓(ya)(ya)器組成。控制(zhi)(zhi)部分(fen)是由(you)接觸式調壓(ya)(ya)器及其(qi)控制(zhi)(zhi)、保護、測量(liang)、信號(hao)電(dian)路組成。試驗(yan)變(bian)壓(ya)(ya)器由(you)低壓(ya)(ya)繞(rao)組、高壓(ya)(ya)繞(rao)組、儀表繞(rao)組三部分(fen)組成。
試驗變(bian)(bian)(bian)(bian)壓器(qi)為交(jiao)直(zhi)流(liu)兩(liang)用(yong)時(shi),試驗變(bian)(bian)(bian)(bian)壓器(qi)配置(zhi)了高(gao)(gao)壓硅(gui)堆(油變(bian)(bian)(bian)(bian)、氣變(bian)(bian)(bian)(bian)為內置(zhi),干變(bian)(bian)(bian)(bian)為外(wai)置(zhi)),高(gao)(gao)壓可輸出交(jiao)流(liu)和直(zhi)流(liu)。輸出交(jiao)流(liu)時(shi),要(yao)求(qiu)接入短(duan)路(lu)桿(油變(bian)(bian)(bian)(bian)、氣變(bian)(bian)(bian)(bian))或去掉外(wai)置(zhi)硅(gui)堆(干變(bian)(bian)(bian)(bian));輸出直(zhi)流(liu)時(shi),要(yao)求(qiu)擰出短(duan)路(lu)桿(油變(bian)(bian)(bian)(bian)、氣變(bian)(bian)(bian)(bian))或加上外(wai)置(zhi)硅(gui)堆(干變(bian)(bian)(bian)(bian))
通(tong)過接(jie)入工(gong)頻電源,調節(jie)調壓器,以獲(huo)得(de)所需要的(de)試驗(yan)高壓電壓值。其工(gong)作原(yuan)理見圖1:
2、試驗部分(fen)接線及原理(li)
做(zuo)耐壓(ya)試驗時,控制部分(fen)、變(bian)壓(ya)器的(de)接地(di)端及高壓(ya)尾必須(xu)可靠(kao)接地(di)。有(you)條件(jian)的(de)情況下,做(zuo)工(gong)頻耐壓(ya)試驗請加上限流(liu)電阻、標準高壓(ya)分(fen)壓(ya)器、球隙保(bao)護電阻及保(bao)護球隙,如圖3。
做直(zhi)流(liu)耐壓試驗請(qing)另外加上(shang)微安表(biao),微安表(biao)必(bi)須(xu)接在(zai)(zai)硅堆和被試器(qi)之間,油(you)變(bian)或氣變(bian)一般擰(ning)在(zai)(zai)高(gao)壓頭(tou)上(shang)面(mian)(要求擰(ning)出(chu)短路桿),干(gan)變(bian)擰(ning)在(zai)(zai)外置硅堆上(shang)面(mian);為了更(geng)準確顯示高(gao)壓直(zhi)流(liu)泄漏電(dian)流(liu),請(qing)將分壓器(qi)的高(gao)壓線接在(zai)(zai)微安表(biao)和硅堆之間,(油(you)變(bian)、氣變(bian))如圖4,(干(gan)變(bian))如圖5。
耐壓試(shi)(shi)驗中(zhong)限(xian)流電(dian)(dian)阻(zu)R1應根據(ju)試(shi)(shi)驗變壓器的額(e)(e)定(ding)(ding)容量(liang)來選擇(ze)。如高(gao)壓側額(e)(e)定(ding)(ding)輸(shu)出電(dian)(dian)流在100~300mA時(shi),可取0.5~1Ω/V(試(shi)(shi)驗電(dian)(dian)壓);高(gao)壓側額(e)(e)定(ding)(ding)輸(shu)出電(dian)(dian)流為(wei)1A以上時(shi),可取1Ω/V(試(shi)(shi)驗電(dian)(dian)壓)。常用(yong)水(shui)電(dian)(dian)阻(zu)作為(wei)限(xian)流電(dian)(dian)阻(zu),管子(zi)長(chang)度(du)可按150kV/m考慮,管子(zi)粗(cu)細應具有足夠的熱(re)容量(liang)(水(shui)阻(zu)液配(pei)制方法(fa):用(yong)蒸(zheng)餾水(shui)加(jia)入適(shi)量(liang)硫酸銅配(pei)制成各種不同(tong)的阻(zu)值)。
球(qiu)間(jian)(jian)隙及保(bao)護電阻(zu):當電壓超過球(qiu)間(jian)(jian)隙整定值時(一般取試(shi)驗電壓的110%~120%),球(qiu)間(jian)(jian)隙放電,對被試(shi)品起到保(bao)護作用。球(qiu)間(jian)(jian)隙保(bao)護電阻(zu)可按1Ω/V(試(shi)驗電壓)選取。
在(zai)工(gong)頻(pin)耐(nai)壓(ya)(ya)(ya)試(shi)(shi)(shi)驗(yan)(yan)(yan)中,低(di)電(dian)(dian)(dian)壓(ya)(ya)(ya)側(ce)測量(liang)電(dian)(dian)(dian)壓(ya)(ya)(ya)(儀(yi)表電(dian)(dian)(dian)壓(ya)(ya)(ya))不是非常準確的(de),其原因是由于(yu)(yu)(yu)試(shi)(shi)(shi)驗(yan)(yan)(yan)變壓(ya)(ya)(ya)器存在(zai)著(zhu)漏(lou)抗(kang),在(zai)這個漏(lou)抗(kang)上(shang)必然(ran)存在(zai)著(zhu)壓(ya)(ya)(ya)降或容(rong)升,使試(shi)(shi)(shi)品(pin)(pin)上(shang)的(de)電(dian)(dian)(dian)壓(ya)(ya)(ya)低(di)于(yu)(yu)(yu)或高(gao)于(yu)(yu)(yu)低(di)壓(ya)(ya)(ya)側(ce)測量(liang)電(dian)(dian)(dian)壓(ya)(ya)(ya)表上(shang)反映出來的(de)電(dian)(dian)(dian)壓(ya)(ya)(ya)。工(gong)頻(pin)耐(nai)壓(ya)(ya)(ya)試(shi)(shi)(shi)驗(yan)(yan)(yan)時,被試(shi)(shi)(shi)品(pin)(pin)上(shang)的(de)電(dian)(dian)(dian)壓(ya)(ya)(ya)高(gao)于(yu)(yu)(yu)試(shi)(shi)(shi)驗(yan)(yan)(yan)變壓(ya)(ya)(ya)器的(de)輸(shu)出電(dian)(dian)(dian)壓(ya)(ya)(ya),也就是所謂容(rong)升現象。感應耐(nai)壓(ya)(ya)(ya)試(shi)(shi)(shi)驗(yan)(yan)(yan)時,試(shi)(shi)(shi)驗(yan)(yan)(yan)變壓(ya)(ya)(ya)器的(de)漏(lou)抗(kang)必然(ran)存在(zai)著(zhu)壓(ya)(ya)(ya)降。為了準確測量(liang)被試(shi)(shi)(shi)品(pin)(pin)上(shang)所施加的(de)電(dian)(dian)(dian)壓(ya)(ya)(ya),因此常在(zai)高(gao)壓(ya)(ya)(ya)側(ce)接入標準高(gao)壓(ya)(ya)(ya)分(fen)壓(ya)(ya)(ya)器來測量(liang)電(dian)(dian)(dian)壓(ya)(ya)(ya)。
五、面板結構(gou)說明(ming)
1、操作箱(xiang)面板
控制箱為箱式鋁合金結構,面板(ban)采用拉絲鋁合金工藝,所有電器(qi)元件(jian)(jian)均裝(zhuang)在(zai)骨架上,便于安(an)裝(zhuang)和維修。面板(ban)元件(jian)(jian)布置如(ru)下:
2、操作臺面(mian)板
操作臺(tai)為(wei)臺(tai)式(shi)結(jie)構(gou),殼體為(wei)冷扎鋼板(ban)結(jie)構(gou),面(mian)板(ban)采用鋁(lv)合金拉絲工藝,面(mian)板(ban)元件布置如下:
六、操作指南
本(ben)裝置在操(cao)作之前應根據不同(tong)被(bei)試品的(de)容量、電壓等級,先計算好(hao)*大工(gong)作電流(liu),并調整電流(liu)保(bao)護器(qi)。其試驗接(jie)線應參考本(ben)說明書中圖1、圖2、圖3、圖4、圖5,必須可靠接(jie)地。
1、操(cao)作要點(dian)
(1)試(shi)(shi)驗(yan)前(qian),應了(le)解(jie)被(bei)(bei)試(shi)(shi)品(pin)(pin)的試(shi)(shi)驗(yan)電壓,同時了(le)解(jie)被(bei)(bei)試(shi)(shi)品(pin)(pin)的其他試(shi)(shi)驗(yan)項(xiang)目及以前(qian)的試(shi)(shi)驗(yan)結果(guo)。若被(bei)(bei)試(shi)(shi)品(pin)(pin)有缺陷或異(yi)常,應在消(xiao)除(chu)后再(zai)進(jin)行耐壓試(shi)(shi)驗(yan)。
(2)試驗現場應(ying)圍好(hao)遮攔或圍繩,掛好(hao)標示牌(pai),并派專人監(jian)護(hu)。
(3)試驗(yan)前,被(bei)試品表面應(ying)擦(ca)拭干凈,將被(bei)試品的外殼和非被(bei)試繞組可靠接(jie)地。被(bei)試品為新(xin)沖油(you)設備時,應(ying)按《規(gui)程》規(gui)定使油(you)靜止一定時間再升(sheng)壓,對110kV及以(yi)下的充油(you)電力(li)設備,在(zai)注滿(man)油(you)后靜置時間應(ying)不少(shao)于(yu)24小時,對220kV及330kV的充油(you)電力(li)設備,靜置時間應(ying)不少(shao)于(yu)48小時。
(4)接好試驗(yan)接線后,應(ying)由(you)有經驗(yan)的(de)人員檢查,確認無誤后方可升壓。
(5)升(sheng)壓(ya)前,首(shou)先檢查調(diao)壓(ya)器是否(fou)在零位。調(diao)壓(ya)器在零位方可升(sheng)壓(ya)。
(6)升(sheng)壓(ya)(ya)(ya)過程中(zhong)不僅要監視電壓(ya)(ya)(ya)表的變化(hua),還應監視電流(liu)表的變化(hua),以及被試(shi)品電流(liu)的變化(hua)。升(sheng)壓(ya)(ya)(ya)時要均勻升(sheng)壓(ya)(ya)(ya),不能太(tai)快。升(sheng)至規定試(shi)驗電壓(ya)(ya)(ya)時,開始(shi)計算時間(jian),時間(jian)到(dao)后,緩(huan)慢均勻降下電壓(ya)(ya)(ya)。絕不允許(xu)不降壓(ya)(ya)(ya)就(jiu)先跳(tiao)開電源開關。
(7)試(shi)驗中發現表針擺動或被(bei)試(shi)品(pin)有異常(chang)聲(sheng)響、冒(mao)煙等應立即降下電壓,拉開(kai)電源,在高壓側掛上(shang)接地線(xian)后,再查明原因(yin)。
(8)耐壓試驗前后均應測量被試品的絕緣電阻(zu)。
2、操作(zuo)步驟(zou)
(1) 按試(shi)驗要求將控制部分、試(shi)驗變(bian)壓器、被(bei)試(shi)品正確接(jie)好線,必須可靠接(jie)地,請參(can)考圖(tu)1、圖(tu)2、圖(tu)3、圖(tu)4、圖(tu)5。
(2) 根據試驗的要(yao)求,整定“時(shi)間繼電(dian)器”及“過流繼電(dian)器”。
A 時間繼(ji)電(dian)器設置:
T1,T2,T3,T4設(she)置0~9任(ren)意(yi)數(shu)字,T可設(she)置為H(小(xiao)時),M(分鐘),S(秒)。
根據試驗要求(qiu),在(zai)1S~99H內可(ke)以任意(yi)設置定時時間。
B 過流繼電器設置:
過流(liu)(liu)(liu)動作設定值=過流(liu)(liu)(liu)繼電器(qi)刻(ke)度盤讀數×測量變比(bi)×K,其中(zhong)K為(wei)電流(liu)(liu)(liu)倍(bei)(bei)率(lv)/切除(chu)開關(guan)的(de)(de)狀態值,分別(bie)為(wei)X1,X2,OFF,電流(liu)(liu)(liu)倍(bei)(bei)率(lv)/切除(chu)開關(guan)處(chu)于(yu)×1,×2位置(zhi)時(shi)(shi),K值分別(bie)為(wei)1、2,切換為(wei)OFF擋時(shi)(shi),K值為(wei)+∞。(注:不要使用OFF檔,因為(wei)會使變壓(ya)器(qi)失去(qu)過流(liu)(liu)(liu)保護(hu)功能而(er)導致設備損壞。測量變比(bi)為(wei)電流(liu)(liu)(liu)互感(gan)器(qi)的(de)(de)變比(bi),沒有電流(liu)(liu)(liu)互感(gan)器(qi)時(shi)(shi)為(wei)1)。
(3) 接入電(dian)源(yuan)(yuan),此時,“電(dian)源(yuan)(yuan)燈(deng)(deng)”亮(liang)(liang),表(biao)示(shi)外部電(dian)源(yuan)(yuan)已引入。如“零(ling)位燈(deng)(deng)”亮(liang)(liang),表(biao)示(shi)調壓器(qi)在零(ling)位。如“零(ling)位燈(deng)(deng)”不亮(liang)(liang),應逆(ni)時針旋轉調節調壓器(qi)手柄至“零(ling)位燈(deng)(deng)”亮(liang)(liang),表(biao)示(shi)可進(jin)行調壓操作。
(4)按“啟動按鈕”。此時,“送(song)電燈”,“電源(yuan)燈”和“零位燈”亮(liang);進入送(song)電狀態。
(5)以2kV/S勻速順時(shi)(shi)針旋(xuan)轉調壓(ya)器手(shou)柄至被試(shi)品規定的耐(nai)壓(ya)值(zhi),并密(mi)切注(zhu)視電流表(直(zhi)流耐(nai)壓(ya)試(shi)驗時(shi)(shi),同(tong)時(shi)(shi)密(mi)切注(zhu)視直(zhi)流微安表)。此(ci)時(shi)(shi),“電源燈”,“工作燈”亮;“零位燈”滅。
(6)根據(ju)試驗啟動(dong)“計時按鈕(niu)”,計時開(kai)始,并注意被(bei)試品的情況。
(7)當耐壓(ya)計(ji)時到時,操作臺自動聲光報警(jing)。應立即(ji)逆時針旋轉調壓(ya)器手柄至零(ling)位,按(an)下(xia)停止(zhi)按(an)鈕和解除計(ji)時按(an)鈕自鎖狀(zhuang)態。此時“電源燈(deng)”, “零(ling)位燈(deng)”亮(liang),“工作燈(deng)”滅。試驗即(ji)告完(wan)畢
(8)拔掉電源,拆(chai)除接線,試驗(yan)結束。
(9)在(zai)升壓(ya)(ya)或耐(nai)壓(ya)(ya)過程中(zhong),如發生(sheng)短(duan)路、閃絡(luo)、擊穿過流時(shi)(shi),過流繼電器動作,切(qie)斷主回(hui)路。此時(shi)(shi)應將(jiang)調(diao)壓(ya)(ya)器逆時(shi)(shi)針旋(xuan)轉至(zhi)零位,切(qie)斷電源,并(bing)查明原因,并(bing)作詳(xiang)細記(ji)錄。
(10)試驗完畢(bi),降壓(ya),切(qie)斷(duan)電(dian)源(yuan)后應用(yong)放(fang)**將被試品及(ji)試驗裝置本身充分放(fang)電(dian)。
七(qi)、產品維護
1、開箱驗收時(shi),應檢查主控回路接(jie)(jie)線是(shi)否(fou)松動,調壓(ya)器電刷是(shi)否(fou)接(jie)(jie)觸(chu)良(liang)好;
2、長期不用(yong)(yong)(yong)時,使用(yong)(yong)(yong)前應(ying)用(yong)(yong)(yong)500V兆歐(ou)表測量(liang)絕緣電(dian)阻(zu),其阻(zu)值不低于0.5MΩ;
3、電源電壓應(ying)符合控制箱(xiang)(臺(tai))銘牌上的輸入電壓值(zhi);
4、本裝置設(she)有過電流(liu)保(bao)護,出(chu)廠(chang)已調整為額(e)定(ding)(ding)電流(liu)的50%。用于小負載時,應(ying)根據被(bei)試品的額(e)定(ding)(ding)容量電流(liu)重(zhong)新設(she)定(ding)(ding);
5、使用完(wan)畢后,應關好控(kong)制(zhi)(zhi)箱(xiang)(臺(tai))門,以保持控(kong)制(zhi)(zhi)箱(xiang)(臺(tai))內部清(qing)潔(jie)。
八、注意事項
1、按(an)照您(nin)所進行的(de)(de)(de)試(shi)驗(yan)接好工(gong)作線路。試(shi)驗(yan)變壓器的(de)(de)(de)外(wai)殼以及(ji)操作系統(tong)的(de)(de)(de)外(wai)殼必(bi)(bi)須(xu)可(ke)靠(kao)接地。試(shi)驗(yan)變壓器的(de)(de)(de)高壓繞組的(de)(de)(de)X端(duan)(高壓尾)以及(ji)測(ce)量繞組的(de)(de)(de)F端(duan)必(bi)(bi)須(xu)可(ke)靠(kao)接地。
2、做串級(ji)試驗時,**級(ji)、第三(san)級(ji)試驗變壓(ya)器(qi)的(de)低(di)壓(ya)繞組成X端,測量繞組的(de)F端以及高(gao)壓(ya)繞組的(de)X端(高(gao)壓(ya)端)均接(jie)本級(ji)試驗變壓(ya)器(qi)具外殼。**級(ji)、第三(san)級(ji)試驗變壓(ya)器(qi)的(de)外殼必須通過絕緣支架接(jie)地。
3、接(jie)通電源(yuan)(yuan)前,操(cao)作系統的調(diao)壓(ya)(ya)(ya)器必須調(diao)到零位后方(fang)可接(jie)通電源(yuan)(yuan),合閘,開始升(sheng)(sheng)壓(ya)(ya)(ya)。從(cong)零開始勻(yun)速(su)旋轉(zhuan)調(diao)壓(ya)(ya)(ya)器手輪(lun)升(sheng)(sheng)壓(ya)(ya)(ya)。升(sheng)(sheng)壓(ya)(ya)(ya)方(fang)式(shi)有:快速(su)升(sheng)(sheng)壓(ya)(ya)(ya)法(fa)(fa),即(ji)20s逐級升(sheng)(sheng)壓(ya)(ya)(ya)法(fa)(fa);慢速(su)升(sheng)(sheng)壓(ya)(ya)(ya)法(fa)(fa),即(ji)60s逐級升(sheng)(sheng)壓(ya)(ya)(ya)法(fa)(fa);極慢速(su)升(sheng)(sheng)壓(ya)(ya)(ya)法(fa)(fa)供選用。電壓(ya)(ya)(ya)從(cong)零開始按(an)一(yi)定(ding)(ding)的升(sheng)(sheng)壓(ya)(ya)(ya)方(fang)式(shi)和速(su)度上(shang)升(sheng)(sheng)到您(nin)所需的額(e)定(ding)(ding)試(shi)(shi)驗電壓(ya)(ya)(ya)的75%后,再(zai)以(yi)每秒2%額(e)定(ding)(ding)試(shi)(shi)驗電壓(ya)(ya)(ya)的速(su)度升(sheng)(sheng)到您(nin)所需的試(shi)(shi)驗電壓(ya)(ya)(ya),并密切注意測量(liang)儀表(biao)的及被試(shi)(shi)品(pin)的情(qing)況(kuang)。升(sheng)(sheng)壓(ya)(ya)(ya)過程中或試(shi)(shi)驗過程中如發(fa)現測量(liang)儀表(biao)的指示及被試(shi)(shi)品(pin)情(qing)況(kuang)異(yi)常,應(ying)立(li)即(ji)降壓(ya)(ya)(ya),切斷(duan)電源(yuan)(yuan),查(cha)明情(qing)況(kuang)。
4、試驗完畢后,應在數秒內勻速的將調壓器返回(hui)至零(ling)位,然后切斷電(dian)源。本產品(pin)不(bu)得超過額(e)定參數使用。
5、使用本(ben)(ben)產品做高壓(ya)試(shi)(shi)驗(yan)(yan)時,除熟悉(xi)本(ben)(ben)說明書外,還必須嚴(yan)格執(zhi)行國家(jia)有(you)關標準(zhun)和(he)操作規(gui)程。可參照GB311.1 – 97《高壓(ya)輸變設備的絕緣配(pei)合(he),高壓(ya)試(shi)(shi)驗(yan)(yan)技術(shu)》;《電氣(qi)設備預防性試(shi)(shi)驗(yan)(yan)規(gui)程》等(deng)
一(yi)、概述
智能耐壓(ya)(ya)試驗裝置(zhi)是根(gen)據國家*新電(dian)(dian)力行業標準(zhun)而設(she)計的、性能先(xian)進(jin)的智能型耐壓(ya)(ya)試驗設(she)備,用于對各種電(dian)(dian)器產品、電(dian)(dian)氣(qi)元件、絕(jue)緣材料等進(jin)行規定(ding)電(dian)(dian)壓(ya)(ya)下的絕(jue)緣強度試驗,以(yi)考核(he)產品的絕(jue)緣水平(ping),發現被試品的絕(jue)緣缺陷,衡量過電(dian)(dian)壓(ya)(ya)的能力。廣泛(fan)應用于電(dian)(dian)工(gong)制造部門、電(dian)(dian)力運行部門、科研單位和(he)高等院校。
二、產品特點(dian)
1. 320×240液晶顯示器、高速熱敏打(da)印機。
2. 高(gao)壓(ya)(ya)(ya)電壓(ya)(ya)(ya)、高(gao)壓(ya)(ya)(ya)電流(liu)、低壓(ya)(ya)(ya)電壓(ya)(ya)(ya)、低壓(ya)(ya)(ya)電流(liu)4路(lu)測量方式,高(gao)精度傳感器和高(gao)性(xing)能14位AD采集芯片。
3. 人機對(dui)話(hua)全鍵盤操作(zuo)方(fang)式(shi),智能化工作(zuo)全過(guo)程,任選自動(dong)方(fang)式(shi)和(he)手動(dong)方(fang)式(shi)。
4. 實時顯示高壓(ya)(ya)電(dian)壓(ya)(ya)、高壓(ya)(ya)電(dian)流、低壓(ya)(ya)電(dian)壓(ya)(ya)、低壓(ya)(ya)電(dian)流,時間及耐壓(ya)(ya)結果,顯示直觀明了。
5. 完(wan)善的過(guo)壓、過(guo)流保護,任意設定輸出(chu)電壓、高壓電流上限、低壓電流上限和計(ji)時(shi)(shi)時(shi)(shi)間。
6. 具有回(hui)(hui)零(ling)檢測功能(neng),回(hui)(hui)零(ling)確定后才可進行試驗(yan),**可靠。
7. 具有(you)絕緣電阻測(ce)試功能,直接反映被(bei)試品絕緣強度。
8. 逼近式調壓算法,到達(da)設定電壓后自動(dong)耐壓計時,計時結(jie)束(shu)后自動(dong)降壓回零。
9. 超過設(she)定高壓電流或低壓電流時自動切斷電壓輸出,降壓回零,并發生聲光(guang)報警。
10. 精良的軟硬件(jian)抗干擾(rao)設計(ji),多種抗干擾(rao)手段,適應惡劣電磁環境。
11. 自動錯誤診斷,易于(yu)發現和(he)解決(jue)問題(ti)。
12. 可選(xuan)配無線遙控(kong)控(kong)制功能、遠程(cheng)通信、門聯鎖警鈴、外接分壓器(qi)校驗接口等。
三、設備組成(cheng)
1、選型配置(zhi)
標準(zhun)配置
|
□ 分體式(shi)
|
操作部分(fen):
□箱式(不大于5kVA) / □臺式
容(rong)量: kVA(小于200kVA)
輸入:□AC220V / □AC380V
|
試驗變壓器:
□交(jiao)流(liu) / □交(jiao)直流(liu)
□油變(bian) / □干變(bian) / □氣變(bian)
容量: kVA(小于200kVA)
輸出:AC kV(小于300kVA)
|
□ 一體式
|
□箱式(不(bu)大于20kV) / □臺式(不(bu)大于30kV)
容量: kVA(小(xiao)于300kVA)
輸(shu)入(ru):□AC220V / □AC380V 輸(shu)出:AC kV(不(bu)大于30kV)
|
客(ke)戶選(xuan)配
|
□標(biao)準高(gao)壓分壓器
|
□保(bao)護球隙
|
□直(zhi)流微安表
|
□放**
|
□保護水阻(zu)
|
□高壓濾(lv)波電容
|
其它:
|
2、對應實物
四、技術(shu)指標(biao)
1、使(shi)用條(tiao)件:
(1)工作場所(suo)應無(wu)嚴重影響絕緣的氣體、蒸汽(qi)、化學性(xing)塵埃及其它爆炸性(xing)和腐蝕性(xing)介(jie)質。
(2)環(huan)境溫度(du) -20~+50℃
(3)環境濕度 ≤85% RH(無(wu)凝結(jie)水(shui))
2、控制箱(臺)參(can)數:(常規參(can)數見下表)
(1)計時(shi)范圍:0-999S
(3)電壓精度(du) ≤1.5% ±1個字(F.S)
(4)電(dian)流精度 ≤1.5% ±1個字(zi)(F.S)
規(gui)格
|
容量(liang)
|
輸 入 電(dian) 源(yuan)
|
輸(shu) 出 電 壓
|
重量(kg)
|
相(xiang)數
|
(V)
|
(A)
|
(V)
|
(A)
|
2/220
|
2
|
1
|
220
|
10
|
0-250
|
8
|
14
|
3/220
|
3
|
1
|
220
|
15
|
0-250
|
12
|
16
|
5/220
|
5
|
1
|
220
|
25
|
0-250
|
20
|
18
|
10/220
|
10
|
1
|
220
|
50
|
0-250
|
40
|
80
|
15/380
|
15
|
2
|
380
|
37.5
|
0-430
|
34.8
|
90
|
20/380
|
20
|
2
|
380
|
50
|
0-430
|
46.5
|
100
|
25/380
|
25
|
2
|
380
|
62.5
|
0-430
|
58.1
|
120
|
30/380
|
30
|
2
|
380
|
75
|
0-430
|
69.7
|
140
|
50/380
|
50
|
2
|
380
|
125
|
0-430
|
116.2
|
160
|
100/380
|
100
|
2
|
380
|
250
|
0-430
|
232.5
|
250
|
說明:如有特殊參(can)數(shu)要求,可按用戶(hu)的技術參(can)數(shu)進行(xing)設(she)計制作。
3、試驗(yan)變壓(ya)器(qi)參(can)數:(常規參(can)數見(jian)下表(biao))
規(gui)格
|
容量
kVA
|
低壓側(ce)
|
高壓側
|
高壓(ya)側(交(jiao)直流(liu)變壓(ya)器(qi))
|
測量變比
|
60分鐘溫(wen)升℃
|
阻(zu)抗電壓(ya)%
|
空載電流(liu)
%
|
質量
kg
|
電(dian)壓
V
|
電流
A
|
交流輸(shu)出
|
直流(liu)輸出(chu)
|
電壓kV
|
電流
|
電壓kV
|
電流(liu)
|
1.5/50
|
1.5
|
200
|
7.5
|
50
|
30
|
70
|
21.4
|
500
|
50
|
10
|
<4
|
19.5
|
3/50
|
3
|
200
|
15
|
50
|
60
|
70
|
42.9
|
500
|
50
|
10
|
<4
|
27
|
5/50
|
5
|
200
|
25
|
50
|
100
|
70
|
71.4
|
500
|
50
|
10
|
<4
|
52
|
10/50
|
10
|
200
|
50
|
50
|
200
|
70
|
142.9
|
500
|
50
|
10
|
<4
|
80
|
15/50
|
15
|
400
|
37.5
|
50
|
300
|
70
|
214.3
|
500
|
50
|
8
|
<4
|
120
|
20/50
|
20
|
400
|
50
|
50
|
400
|
70
|
285.7
|
500
|
50
|
8
|
<4
|
140
|
30/50
|
30
|
400
|
75
|
50
|
600
|
70
|
428.6
|
500
|
50
|
8
|
<4
|
155
|
50/50
|
50
|
400
|
125
|
50
|
1000
|
70
|
714.3
|
500
|
50
|
8
|
<4
|
184
|
10/100
|
10
|
200
|
50
|
100
|
100
|
140
|
71.4
|
1000
|
50
|
10
|
<4
|
135
|
15/100
|
15
|
400
|
37.5
|
100
|
150
|
140
|
107.1
|
1000
|
50
|
8
|
<4
|
150
|
20/100
|
20
|
400
|
50
|
100
|
200
|
140
|
142.9
|
1000
|
50
|
8
|
<4
|
215
|
30/100
|
30
|
400
|
75
|
100
|
300
|
140
|
214.3
|
1000
|
50
|
8
|
<4
|
250
|
50/100
|
50
|
400
|
125
|
100
|
500
|
140
|
357.1
|
1000
|
50
|
8
|
<4
|
290
|
10/150
|
10
|
200
|
50
|
100
|
66.7
|
140
|
47.6
|
1500
|
50
|
10
|
<4
|
180
|
15/150
|
15
|
400
|
37.5
|
150
|
100
|
210
|
71.4
|
1500
|
50
|
8
|
<4
|
200
|
20/150
|
30
|
400
|
50
|
150
|
133.3
|
210
|
95.2
|
1500
|
50
|
8
|
<4
|
220
|
30/150
|
30
|
400
|
75
|
150
|
200
|
210
|
142.9
|
1500
|
50
|
8
|
<4
|
280
|
50/150
|
50
|
400
|
125
|
150
|
333.3
|
210
|
238.1
|
1500
|
50
|
8
|
<4
|
340
|
說(shuo)明:如有特(te)殊參數要求,可(ke)按用戶的(de)技術參數進行設(she)計制作。
上表的重量(liang)以油浸式試(shi)(shi)驗變(bian)壓(ya)(ya)(ya)器為例,干(gan)式試(shi)(shi)驗變(bian)壓(ya)(ya)(ya)器和充氣(qi)式試(shi)(shi)驗變(bian)壓(ya)(ya)(ya)器稍有不同(tong)。
五、接線及工(gong)作原理(li)
1、調壓部(bu)分(fen)接線及原(yuan)理
調壓(ya)部分由控制部分和試驗變(bian)壓(ya)器(qi)組成(cheng)。控制部分是由接觸式調壓(ya)器(qi)、單片機控制系統、液晶(jing)、打(da)印(yin)機、信號測量、電(dian)路保護組成(cheng)。試驗變(bian)壓(ya)器(qi)由低壓(ya)繞(rao)組、高壓(ya)繞(rao)組、儀表(biao)繞(rao)組三部分組成(cheng)。
試驗變(bian)(bian)壓(ya)器為(wei)交(jiao)直(zhi)(zhi)流(liu)兩用時(shi),試驗變(bian)(bian)壓(ya)器配(pei)置(zhi)了高壓(ya)硅堆(油(you)(you)變(bian)(bian)、氣(qi)(qi)變(bian)(bian)為(wei)內(nei)置(zhi),干變(bian)(bian)為(wei)外(wai)(wai)置(zhi)),高壓(ya)可輸出(chu)交(jiao)流(liu)和直(zhi)(zhi)流(liu)。輸出(chu)交(jiao)流(liu)時(shi),要求接入(ru)短(duan)路桿(油(you)(you)變(bian)(bian)、氣(qi)(qi)變(bian)(bian))或(huo)去掉外(wai)(wai)置(zhi)硅堆(干變(bian)(bian));輸出(chu)直(zhi)(zhi)流(liu)時(shi),要求擰出(chu)短(duan)路桿(油(you)(you)變(bian)(bian)、氣(qi)(qi)變(bian)(bian))或(huo)加上外(wai)(wai)置(zhi)硅堆(干變(bian)(bian))
通過(guo)接入(ru)工(gong)頻電源,調節調壓(ya)(ya)器,以(yi)獲得所需要的試驗高壓(ya)(ya)電壓(ya)(ya)值。其(qi)工(gong)作原(yuan)理見圖1:
2、試驗(yan)部(bu)分接線(xian)及原理(li)
做耐(nai)壓(ya)試驗時,控(kong)制部分、變壓(ya)器的接地端及(ji)高壓(ya)尾必須可靠接地。有條件的情況下,做工頻(pin)耐(nai)壓(ya)試驗請加上限流電阻、標(biao)準(zhun)高壓(ya)分壓(ya)器、球隙(xi)保護電阻及(ji)保護球隙(xi),如圖3。
做直(zhi)流耐壓(ya)(ya)(ya)試(shi)驗請另外加(jia)上(shang)(shang)微安表(biao),微安表(biao)必須接在(zai)(zai)硅堆(dui)和被試(shi)器之間,油變(bian)(bian)(bian)或氣變(bian)(bian)(bian)一般擰(ning)在(zai)(zai)高壓(ya)(ya)(ya)頭上(shang)(shang)面(mian)(要求擰(ning)出短路桿),干(gan)變(bian)(bian)(bian)擰(ning)在(zai)(zai)外置硅堆(dui)上(shang)(shang)面(mian);為(wei)了更準(zhun)確顯示高壓(ya)(ya)(ya)直(zhi)流泄(xie)漏電流,請將(jiang)分壓(ya)(ya)(ya)器的(de)高壓(ya)(ya)(ya)線接在(zai)(zai)微安表(biao)和硅堆(dui)之間,(油變(bian)(bian)(bian)、氣變(bian)(bian)(bian))如圖4,(干(gan)變(bian)(bian)(bian))如圖5。
耐壓試(shi)(shi)驗(yan)中限流電(dian)阻(zu)(zu)R1應根據(ju)試(shi)(shi)驗(yan)變壓器的(de)額定(ding)容量來選擇。如高(gao)壓側額定(ding)輸(shu)出電(dian)流在(zai)100~300mA時,可取(qu)0.5~1Ω/V(試(shi)(shi)驗(yan)電(dian)壓);高(gao)壓側額定(ding)輸(shu)出電(dian)流為1A以上時,可取(qu)1Ω/V(試(shi)(shi)驗(yan)電(dian)壓)。常(chang)用水(shui)電(dian)阻(zu)(zu)作為限流電(dian)阻(zu)(zu),管子長度可按150kV/m考慮,管子粗細(xi)應具有(you)足夠的(de)熱(re)容量(水(shui)阻(zu)(zu)液配(pei)制方法:用蒸餾水(shui)加入適量硫酸銅(tong)配(pei)制成各種(zhong)不同的(de)阻(zu)(zu)值)。
球間(jian)隙及保(bao)護(hu)電(dian)(dian)阻:當電(dian)(dian)壓超過球間(jian)隙整(zheng)定值時(一般取試驗電(dian)(dian)壓的110%~120%),球間(jian)隙放電(dian)(dian),對被試品起到保(bao)護(hu)作用。球間(jian)隙保(bao)護(hu)電(dian)(dian)阻可按(an)1Ω/V(試驗電(dian)(dian)壓)選取。
在(zai)(zai)工頻耐(nai)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)驗(yan)中,低(di)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)側(ce)(ce)測(ce)量電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)(儀表電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya))不是(shi)非常準確的(de),其原因是(shi)由于試(shi)驗(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器存在(zai)(zai)著漏(lou)抗(kang)(kang),在(zai)(zai)這(zhe)個漏(lou)抗(kang)(kang)上必然存在(zai)(zai)著壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)降或容升,使試(shi)品(pin)上的(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)低(di)于或高于低(di)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)側(ce)(ce)測(ce)量電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)表上反映出來的(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)。工頻耐(nai)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)驗(yan)時,被(bei)試(shi)品(pin)上的(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)高于試(shi)驗(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器的(de)輸出電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya),也(ye)就是(shi)所(suo)謂容升現象(xiang)。感應耐(nai)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)驗(yan)時,試(shi)驗(yan)變壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器的(de)漏(lou)抗(kang)(kang)必然存在(zai)(zai)著壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)降。為了準確測(ce)量被(bei)試(shi)品(pin)上所(suo)施加(jia)的(de)電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya),因此常在(zai)(zai)高壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)側(ce)(ce)接入標準高壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)分壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)器來測(ce)量電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)(ya)。
六、操(cao)作要(yao)點
1、試(shi)驗前(qian),應了解(jie)被(bei)試(shi)品的(de)試(shi)驗電壓,同時了解(jie)被(bei)試(shi)品的(de)其他試(shi)驗項(xiang)目及以前(qian)的(de)試(shi)驗結果。若被(bei)試(shi)品有缺陷或異常,應在(zai)消除后再進行(xing)耐(nai)壓試(shi)驗。
2、試驗(yan)現場應(ying)圍(wei)(wei)好(hao)(hao)遮攔(lan)或圍(wei)(wei)繩,掛好(hao)(hao)標示牌,并派(pai)專人(ren)監護。
3、試(shi)驗前,被(bei)(bei)試(shi)品(pin)表面(mian)應擦拭干(gan)凈,將被(bei)(bei)試(shi)品(pin)的(de)外(wai)殼和非被(bei)(bei)試(shi)繞組可(ke)靠接(jie)地。被(bei)(bei)試(shi)品(pin)為新(xin)沖油設(she)備(bei)時(shi),應按(an)《規(gui)程(cheng)》規(gui)定使(shi)油靜(jing)止一定時(shi)間再升壓,對110kV及(ji)以下(xia)的(de)充(chong)油電力(li)設(she)備(bei),在注(zhu)滿油后靜(jing)置時(shi)間應不少于(yu)24小時(shi),對220kV及(ji)330kV的(de)充(chong)油電力(li)設(she)備(bei),靜(jing)置時(shi)間應不少于(yu)48小時(shi)。
4、接好試驗接線后,應由有(you)經驗的人員檢查,確認無誤后方可升壓。
5、升壓前,首先檢(jian)查調壓器是否在(zai)零位。調壓器在(zai)零位方可(ke)升壓。
6、升(sheng)壓(ya)(ya)過程中不(bu)僅要監(jian)視(shi)電(dian)(dian)壓(ya)(ya)的(de)變化(hua),還應監(jian)視(shi)電(dian)(dian)流的(de)變化(hua),以及被試品泄漏電(dian)(dian)流的(de)變化(hua)。升(sheng)壓(ya)(ya)時要均勻(yun)升(sheng)壓(ya)(ya),不(bu)能太快。升(sheng)至規定試驗電(dian)(dian)壓(ya)(ya)時,開始計(ji)時,時間到后,緩(huan)慢均勻(yun)降下電(dian)(dian)壓(ya)(ya)。絕不(bu)允(yun)許不(bu)降壓(ya)(ya)就先跳開電(dian)(dian)源(yuan)開關。
7、試(shi)(shi)驗(yan)中發現被試(shi)(shi)品(pin)有異(yi)常聲響(xiang)、冒煙等應(ying)立即降下(xia)電壓,拉開電源,在高(gao)壓側(ce)掛(gua)上接地線后,再查明原因。耐壓試(shi)(shi)驗(yan)前(qian)后均(jun)應(ying)測量被試(shi)(shi)品(pin)的絕緣電阻。
七、面(mian)板功能說(shuo)明
打(da)印(yin)(yin)(yin)機(ji):打(da)印(yin)(yin)(yin)機(ji)是熱敏打(da)印(yin)(yin)(yin)機(ji),當試驗(yan)完成后(hou)按鍵盤上的(de)“打(da)印(yin)(yin)(yin)”按鈕打(da)印(yin)(yin)(yin)試驗(yan)結果。
RS232:RS232是與計算機相連的串口通信接(jie)口,是用戶選配接(jie)口,本裝置沒有(you)配置這個(ge)接(jie)口。
LCD對(dui)比度:因為(wei)液晶顯示屏在溫度和光線有(you)所不同時稍(shao)有(you)些變化(hua),可以通過LCD對(dui)比度調節背光到適合(he)亮度。
液(ye)晶(jing): 320x240像(xiang)素點陣白色背光(guang)液(ye)晶(jing),在(zai)強(qiang)光(guang)和陰(yin)暗環(huan)境(jing)下都十(shi)分(fen)清楚(chu)。
指示燈(deng):由啟動(dong)燈(deng)、零位(wei)燈(deng)、指示燈(deng)三個燈(deng)組成,啟動(dong)燈(deng)和警示燈(deng)是高亮(liang)七彩燈(deng)。
操作提示:有一(yi)些簡短的提示語句和安裝接線圖。
緊急(ji)開關(guan):在(zai)緊急(ji)情況下按(an)此開關(guan),即(ji)可以(yi)切(qie)斷變(bian)壓器電源(yuan),也可以(yi)切(qie)斷工作電源(yuan)。(箱式安(an)裝在(zai)面板上,臺式安(an)裝在(zai)柜(ju)體(ti)上)
鍵(jian)盤(pan):由上、下、左、右、設置、打(da)印、確定、取消(xiao)8個(ge)鍵(jian)組成,是用戶和設備交(jiao)互的(de)終端。
電源(yuan)開關:工作電源(yuan),帶通(tong)電指示燈。
八、軟件使用說明(ming)
按試(shi)驗要求將控制部(bu)分、試(shi)驗變壓器、被試(shi)品正確接(jie)好線,必(bi)須(xu)可靠接(jie)地,請參(can)考圖1、圖2、圖3、圖4、圖5。
1、開機使用(yong)
開機處于“歡迎界面”,如圖(tu)7:
根據鍵盤的示圖8,按上(shang)↑、下↓、左(zuo)←,右→可(ke)以切換“自動(dong)耐壓試(shi)驗(yan)(yan)”或(huo)“手動(dong)耐壓試(shi)驗(yan)(yan)”,在“自動(dong)試(shi)驗(yan)(yan)”或(huo)“手動(dong)試(shi)驗(yan)(yan)”里(li)面選擇“交流試(shi)驗(yan)(yan)方(fang)式”或(huo)“直流試(shi)驗(yan)(yan)方(fang)式”。如(ru)圖9
說明:
(1)當配置的是交直(zhi)流(liu)兩用控制(zhi)部(bu)分(fen)時,使用直(zhi)流(liu)輸(shu)出時軟(ruan)件(jian)操作(zuo)請進入直(zhi)流(liu)試(shi)驗(yan)方式(shi),交流(liu)輸(shu)出時軟(ruan)件(jian)操作(zuo)請進入交流(liu)試(shi)驗(yan)方式(shi),如(ru)果選擇錯誤會導致儀器(qi)顯示電(dian)(dian)壓會和輸(shu)出實際電(dian)(dian)壓不一致。
(2)當(dang)配置的(de)是交直流兩用(yong)(yong)變壓器(qi)時,使(shi)用(yong)(yong)直流時請(qing)將變壓器(qi)的(de)短(duan)路桿取出,當(dang)使(shi)用(yong)(yong)交流時請(qing)將短(duan)路桿插入(ru)擰緊。
(3)如(ru)(ru)果配置的是交流控制部分時,軟件界(jie)面里就沒有交直流試驗(yan)方(fang)式(如(ru)(ru)圖9)的選(xuan)擇項。
選(xuan)中試(shi)驗(yan)方式后,按確定可以進入(ru)主界面(mian),如圖10:
動(dong)態顯示區:一直(zhi)處于采集信(xin)號,并顯示高壓(ya)電(dian)壓(ya)、高壓(ya)電(dian)流(liu)、低(di)(di)壓(ya)電(dian)壓(ya)、低(di)(di)壓(ya)電(dian)流(liu)。
結果(guo)顯示(shi)(shi)區:如(ru)果(guo)試驗(yan)沒有被擊穿時,顯示(shi)(shi)平(ping)均高壓(ya)(ya)電(dian)壓(ya)(ya),平(ping)均高壓(ya)(ya)電(dian)流,平(ping)均低(di)壓(ya)(ya)電(dian)壓(ya)(ya),平(ping)均低(di)壓(ya)(ya)電(dian)流,絕緣(yuan)電(dian)阻(zu);否之,顯示(shi)(shi)峰(feng)(feng)值電(dian)壓(ya)(ya),峰(feng)(feng)值電(dian)流,低(di)壓(ya)(ya)電(dian)壓(ya)(ya),低(di)壓(ya)(ya)電(dian)流。
設(she)置(zhi)(zhi)數(shu)據(ju)區:設(she)置(zhi)(zhi)試驗中需(xu)要的(de)參數(shu)數(shu)據(ju)輸(shu)出電(dian)(dian)壓(ya)(ya)為(wei)在自動方(fang)式下的(de)升(sheng)壓(ya)(ya)目標耐(nai)壓(ya)(ya)值(zhi)耐(nai)壓(ya)(ya)時間為(wei)耐(nai)壓(ya)(ya)過(guo)程(cheng)的(de)時間長度電(dian)(dian)流上(shang)限(xian)為(wei)高壓(ya)(ya)電(dian)(dian)流峰(feng)值(zhi)的(de)上(shang)限(xian),高壓(ya)(ya)電(dian)(dian)流超過(guo)電(dian)(dian)流上(shang)限(xian)將認為(wei)擊(ji)穿過(guo)流保護(hu)(hu)為(wei)低壓(ya)(ya)電(dian)(dian)流峰(feng)值(zhi)的(de)上(shang)限(xian),低壓(ya)(ya)電(dian)(dian)流超過(guo)過(guo)流保護(hu)(hu)將認為(wei)擊(ji)穿
信息顯示區:顯示試驗過程中的試驗狀態和提示信息。
試驗(yan)操(cao)作(zuo)區:選擇設置、試驗(yan)、回零命(ming)令。
2、設置參數
在主界(jie)(jie)面上,選中“設(she)置(zhi)”,然后按(an)確定后進入設(she)置(zhi)界(jie)(jie)面,如圖11:
按左←,右→時切換光(guang)(guang)標(biao)移動位(wei)(wei)置(zhi)(zhi),按上↑、下↓時更改光(guang)(guang)標(biao)位(wei)(wei)置(zhi)(zhi)數(shu)(shu)據的值。光(guang)(guang)標(biao)位(wei)(wei)置(zhi)(zhi)和設(she)置(zhi)(zhi)的數(shu)(shu)值全(quan)部可以自動循環,前且在使用(yong)時有默認的標(biao)準(zhun)值。如果所有的參數(shu)(shu)都設(she)置(zhi)(zhi)完成(cheng),按取消(xiao)退出設(she)置(zhi)(zhi)回到主(zhu)界面開(kai)始狀態。
3、手動試驗
零(ling)(ling)位檢查—當(dang)選中“試驗(yan)”后(hou),按確(que)定就進入提(ti)示(shi)試驗(yan)狀態。如(ru)果(guo)調壓(ya)器不在零(ling)(ling)位,將(jiang)提(ti)示(shi)“試驗(yan)前(qian)請先(xian)回(hui)零(ling)(ling)”,退出試驗(yan)并且(qie)切換到回(hui)零(ling)(ling)命令。
試驗(yan)過程—回零確(que)認后,可以(yi)進行試驗(yan)。選中“試驗(yan)”后按確(que)定,接觸(chu)器合閘,這時輸出電壓幾乎(hu)為0,如圖12:
按(an)上↑,高壓(ya)電(dian)壓(ya)將不斷升壓(ya),松開就停(ting)止(zhi)升壓(ya),如果到上限(xian)就提示(shi)滿(man)量程(cheng);
按下↓,高壓(ya)電壓(ya)將不斷降壓(ya),松開(kai)就(jiu)停止降壓(ya),如果到(dao)下限就(jiu)提示已回(hui)零(ling);
按計時←,計時開(kai)始工作,到(dao)耐壓(ya)時間計時結束完成(cheng)試驗;
按取(qu)消→,取(qu)消試驗過程;
在升壓(ya)(ya)過(guo)程中,如果高壓(ya)(ya)電(dian)(dian)(dian)(dian)(dian)流(liu)(liu)(liu)(liu)峰值(zhi)(zhi)超(chao)過(guo)“電(dian)(dian)(dian)(dian)(dian)流(liu)(liu)(liu)(liu)上(shang)限(xian)”值(zhi)(zhi)或低壓(ya)(ya)電(dian)(dian)(dian)(dian)(dian)流(liu)(liu)(liu)(liu)峰值(zhi)(zhi)超(chao)過(guo)“過(guo)流(liu)(liu)(liu)(liu)保護”值(zhi)(zhi)將認為被試(shi)品被擊穿,接(jie)觸器立(li)刻分閘并顯示(shi)試(shi)驗結(jie)(jie)果,包括峰值(zhi)(zhi)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)、峰值(zhi)(zhi)電(dian)(dian)(dian)(dian)(dian)流(liu)(liu)(liu)(liu)、低壓(ya)(ya)電(dian)(dian)(dian)(dian)(dian)流(liu)(liu)(liu)(liu)等,調壓(ya)(ya)器開(kai)始回零(ling)(ling),回零(ling)(ling)完(wan)成試(shi)驗結(jie)(jie)束(shu)。如果在耐壓(ya)(ya)過(guo)程中,高壓(ya)(ya)電(dian)(dian)(dian)(dian)(dian)流(liu)(liu)(liu)(liu)和低壓(ya)(ya)電(dian)(dian)(dian)(dian)(dian)流(liu)(liu)(liu)(liu)峰值(zhi)(zhi)沒有(you)超(chao)設置上(shang)限(xian)值(zhi)(zhi),認為被試(shi)品未擊穿,結(jie)(jie)果顯示(shi)區就顯示(shi)耐壓(ya)(ya)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)、高壓(ya)(ya)電(dian)(dian)(dian)(dian)(dian)流(liu)(liu)(liu)(liu)、低壓(ya)(ya)電(dian)(dian)(dian)(dian)(dian)流(liu)(liu)(liu)(liu)、絕緣電(dian)(dian)(dian)(dian)(dian)阻等,調壓(ya)(ya)器開(kai)始回零(ling)(ling),回零(ling)(ling)完(wan)成后(hou)接(jie)觸器分閘試(shi)驗結(jie)(jie)束(shu)。
4、自動試驗
自動(dong)試驗(yan)和手(shou)動(dong)試驗(yan)的(de)試驗(yan)過程(cheng)類(lei)似,首先也進行回零檢查,確認后(hou)進入如下界面,如圖13:
按上(shang)方(fang)法切換(huan)到“開(kai)始(shi)”確(que)定后進行試驗(yan),與手動試驗(yan)不同之(zhi)處就是升壓過程(cheng)將自動升壓到“輸出電壓”值,然后進行計時。
升(sheng)壓(ya)(ya)過程為(wei)逼近(jin)方式(shi),首先(xian)升(sheng)到到接(jie)近(jin)目標值(zhi),然后再(zai)進行微調,保證高壓(ya)(ya)電壓(ya)(ya)值(zhi)幾乎為(wei)輸出電壓(ya)(ya)值(zhi)。
5、功能(neng)選擇(ze)
按鍵(jian)盤(pan)上的(de)“設置”就進入功能界(jie)面,如圖14:
進入(ru)功能界(jie)面(mian)后,可以(yi)選擇“時鐘設(she)置”、“注意事項”等界(jie)面(mian)。
時鐘(zhong)設置(zhi):設置(zhi)時鐘(zhong)的時間,為(wei)打印報表提供(gong)時間依(yi)據。
注(zhu)意(yi)事項:為用戶提供(gong)一些操作規(gui)范和**注(zhu)意(yi)事項。
6、打印
按(an)鍵盤(pan)“打印”按(an)鍵可以打印試驗果,在此(ci)不贅(zhui)述(shu)。
七、產品(pin)維護
1、開箱(xiang)驗收(shou)時,應檢查主控(kong)回路接(jie)線是否(fou)松動,調壓器電(dian)刷(shua)是否(fou)接(jie)觸良(liang)好。
2.、長期不(bu)用(yong)(yong)時,使用(yong)(yong)前(qian)應用(yong)(yong)500V兆歐表測量絕緣電阻,其阻值不(bu)低于0.5MΩ。
3、電(dian)(dian)源電(dian)(dian)壓應符合控(kong)制(zhi)箱(臺)說明書(shu)上的輸入電(dian)(dian)壓值要求。
4、本控制(zhi)箱(xiang)(臺)設有過(guo)電(dian)流保護,出廠已調整為額定(ding)電(dian)流的50%。用于小(xiao)負載時(shi),應根據被(bei)試品的額定(ding)容量電(dian)流重(zhong)新設定(ding);
5、使用(yong)完畢后(hou),應關好控(kong)制箱(臺)門蓋,以保持內部(bu)清潔。
八、注意事(shi)項
1、按照您所進行的試(shi)驗(yan)接(jie)好(hao)工作線路。試(shi)驗(yan)變(bian)壓(ya)器的外(wai)(wai)殼以及(ji)操作系統的外(wai)(wai)殼必須(xu)可(ke)靠接(jie)地(di)。試(shi)驗(yan)變(bian)壓(ya)器的測量繞組的F端和外(wai)(wai)殼必須(xu)可(ke)靠接(jie)地(di)。
2、做(zuo)串級(ji)試(shi)驗時,**級(ji)、第三級(ji)試(shi)驗變(bian)(bian)壓器(qi)的(de)低壓繞(rao)組(zu)成(cheng)X端,測量繞(rao)組(zu)的(de)F端以及(ji)高壓繞(rao)組(zu)的(de)X端(高壓端)均接本級(ji)試(shi)驗變(bian)(bian)壓器(qi)具外殼。**級(ji)、第三級(ji)試(shi)驗變(bian)(bian)壓器(qi)的(de)外殼必須通過絕緣(yuan)支(zhi)架接地(di)。
接(jie)通電源前,控制箱(臺(tai))的(de)調壓器必須調到零位(wei)后方可接(jie)通電源,合閘,開始升壓。
3、從(cong)零開(kai)始勻速(su)旋轉調(diao)壓(ya)(ya)器手輪升(sheng)壓(ya)(ya)。升(sheng)壓(ya)(ya)方式有:快速(su)升(sheng)壓(ya)(ya)法(fa),即20s逐級升(sheng)壓(ya)(ya)法(fa);慢速(su)升(sheng)壓(ya)(ya)法(fa),即60s逐級升(sheng)壓(ya)(ya)法(fa);極慢速(su)升(sheng)壓(ya)(ya)法(fa)供選用。電壓(ya)(ya)從(cong)零開(kai)始按(an)一定的(de)(de)(de)升(sheng)壓(ya)(ya)方式和(he)速(su)度上升(sheng)到您所需的(de)(de)(de)額(e)定試驗電壓(ya)(ya)的(de)(de)(de)75%后,再以每(mei)秒(miao)2%額(e)定試驗電壓(ya)(ya)的(de)(de)(de)速(su)度升(sheng)到您所需的(de)(de)(de)試驗電壓(ya)(ya),并(bing)密(mi)切注意測量(liang)儀表的(de)(de)(de)及被試品的(de)(de)(de)情況。升(sheng)壓(ya)(ya)過(guo)程中(zhong)或(huo)試驗過(guo)程中(zhong)如發現(xian)測量(liang)儀表的(de)(de)(de)指示及被試品情況異常,應立即降壓(ya)(ya),切斷電源,查明(ming)情況。
4、試驗完畢后,應在等調壓器返回(hui)至零位,然后切斷電源。
5、本產(chan)品不得超過額定參(can)數使用。
6、使用本產品做高(gao)壓(ya)(ya)(ya)試(shi)驗時(shi),除熟(shu)悉(xi)本說明書外,還必(bi)須(xu)嚴格執行(xing)國家有關(guan)標準和(he)操作規程。可(ke)參照GB311.1 – 97《高(gao)壓(ya)(ya)(ya)輸變設(she)備(bei)的絕緣(yuan)配合(he),高(gao)壓(ya)(ya)(ya)試(shi)驗技術(shu)》;《電氣設(she)備(bei)預防性試(shi)驗規程》等。
7、控(kong)(kong)制箱(臺(tai))應(ying)與試驗(yan)變(bian)壓器配(pei)套使(shi)用,控(kong)(kong)制箱(臺(tai))的(de)使(shi)用方法,請詳細參閱(yue)控(kong)(kong)制器的(de)使(shi)用說明書。