一、WBYD2000串聯諧振基本原理
耐(nai)壓(ya)(ya)試驗(yan)是利用(yong)電(dian)抗器的(de)電(dian)感與(yu)被(bei)試品電(dian)容組(zu)成LC串聯(lian)回(hui)路(lu),調節變頻電(dian)源輸出的(de)電(dian)壓(ya)(ya)頻率,在被(bei)試品上獲(huo)得高(gao)電(dian)壓(ya)(ya),是當(dang)前高(gao)電(dian)壓(ya)(ya)試驗(yan)的(de)一種新方法,深(shen)受專家(jia)好(hao)評,在國內外已(yi)經得到廣(guang)泛的(de)使(shi)用(yong)。
根據諧振原理,我們知道(dao)當電(dian)抗(kang)器L的感(gan)抗(kang)值Xl與(yu)回路中的容(rong)抗(kang)值Xc相等時,回路達到諧振狀態,此(ci)時回路中僅回路電(dian)阻R消耗有功(gong)(gong)功(gong)(gong)率,而無功(gong)(gong)功(gong)(gong)率則在(zai)電(dian)抗(kang)器與(yu)試(shi)品(pin)電(dian)容(rong)之間來回振蕩(dang),從而在(zai)試(shi)品(pin)上產生(sheng)高壓。
二、WBYD2000串聯諧振系統構成
全套(tao)試(shi)驗(yan)系(xi)統(tong)由調頻電源主機(ji)、電抗器、分壓(ya)(ya)器、激勵變壓(ya)(ya)器和補(bu)償電容器(可(ke)選(xuan)器件)組成,接入被試(shi)品后組成一(yi)個諧振系(xi)統(tong)進(jin)行交(jiao)流耐壓(ya)(ya)實驗(yan)。
主機: 就是一臺幅值(zhi)和(he)頻(pin)率可調(diao)的正(zheng)弦波交(jiao)流調(diao)頻(pin)電源(yuan),給諧振回路提供激勵源(yuan),同(tong)時提供電壓顯(xian)示、電流顯(xian)示、計時、保護、報警等(deng)功(gong)能。
電(dian)抗器:就是(shi)一(yi)個大電(dian)感線(xian)圈,與被試(shi)品(相當于電(dian)容(rong))構成回路(lu),可配置電(dian)抗器多節電(dian)抗器,使用時通過不(bu)同(tong)的(de)串聯、并(bing)聯組(zu)合、實現不(bu)同(tong)的(de)電(dian)感量以適用不(bu)同(tong)的(de)試(shi)驗條件。
分(fen)壓器:內部通過電(dian)容(rong)器分(fen)壓,從試(shi)品上高電(dian)壓分(fen)得低(di)電(dian)壓供主機測(ce)量、控(kong)制使用。
勵磁變壓器(qi):隔離主(zhu)機電(dian)源(yuan)與諧振回路電(dian)源(yuan),并(bing)升高主(zhu)機的輸出電(dian)壓。
補(bu)償電容器:當試(shi)品電容量(liang)很(hen)小時(shi),如果要實(shi)(shi)現系統諧振可能(neng)要求的電源頻率超出(chu)試(shi)驗(yan)(yan)標(biao)準的規定,可在試(shi)品上并聯一個補(bu)償電容,以實(shi)(shi)現試(shi)驗(yan)(yan)要求,稱此電容器為補(bu)償電容器。
三、WBYD2000串聯諧振主要技術性能
功率電(dian)源電(dian)壓:AC380V±10%、50Hz;
儀器電源:220V±10%、50Hz;
諧振(zhen)輸出容(rong)量:200kVA;
儀器額(e)定電壓:0~200kV;
輸出頻率范圍:30~300Hz;
輸出(chu)電壓波(bo)形(xing):正弦波(bo),波(bo)形(xing)畸變率<0.5%;
頻(pin)率調(diao)節靈敏度:0.1Hz,不穩(wen)定度≤0.05%;
系統噪聲:≤60db;
9、系(xi)統測量精度:<1級;
10.輸出(chu)電(dian)壓不(bu)穩(wen)定:<0.5%;
11.保(bao)護響應時間:1us;
12.電(dian)感非線性度:≤0.05%;;
13.滿功(gong)率輸出下,連續工作時間為60min
14.環境(jing)溫度:-15℃~+50℃;
15.相對濕度(du):≤90%RH;
16.海拔高度:≤2000米。
四、WBYD2000串聯諧振面板及部件名稱
五、WBYD2000串聯諧振操作步驟
1、正確連線(xian),檢查無誤后方可送電。
必要時工作電源的跳(tiao)過現場漏電保(bao)安(an)器,以免不必要的跳(tiao)閘。
2、打開電源(yuan)開關,主機(ji)開始工作,液(ye)晶屏顯示版權(quan)頁(ye),該頁(ye)標明本(ben)裝置的(de)軟件版本(ben)號(hao)。
觸按確(que)認(ren)鍵(jian),進入系統菜(cai)單,該主(zhu)菜(cai)單下有:試(shi)驗(yan)方案、開始試(shi)驗(yan)、試(shi)驗(yan)幫(bang)助、系統設置、實用工具和(he)試(shi)驗(yan)記(ji)錄等六個(ge)子(zi)菜(cai)單項。
3、 系統(tong)設置(zhi)菜(cai)單下(xia)有電(dian)(dian)抗(kang)(kang)器(qi)電(dian)(dian)感、日(ri)期時間(jian)設置(zhi)和(he)采(cai)樣系數(shu)設置(zhi)等三個(ge)子菜(cai)單項(xiang)。按(an)上(shang)下(xia)鍵,上(shang)下(xia)移動光標(biao)系統(tong)參(can)(can)數(shu)設置(zhi)菜(cai)單項(xiang),觸按(an)確(que)定(ding)鈕后,進入系統(tong)參(can)(can)數(shu)設置(zhi)菜(cai)單,可(ke)以分別設定(ding)電(dian)(dian)抗(kang)(kang)器(qi)的電(dian)(dian)感—H、-年(nian)-月-日(ri)、-時-分-秒和(he)電(dian)(dian)壓和(he)電(dian)(dian)流的采(cai)樣系數(shu)也(ye)就是(shi)采(cai)樣倍率,設定(ding)完(wan)成(cheng)后,觸按(an)返(fan)還鍵返(fan)回上(shang)**菜(cai)單。
電抗器電感(gan)量(liang)的(de)設(she)定(ding):按(an)確(que)定(ding)鍵(jian)選擇到此項,按(an)左右鍵(jian)移動光(guang)標需要(yao)改(gai)變的(de)數(shu)(shu)位,按(an)上(shang)下鍵(jian)改(gai)變數(shu)(shu)值,達到所要(yao)達到的(de)數(shu)(shu)值按(an)確(que)定(ding)鍵(jian)確(que)認。
日期時間的(de)設定(ding):按確定(ding)鍵(jian)選擇到此項(xiang),按左右鍵(jian)移動光標(biao)需要(yao)改變的(de)數位(wei),按上下鍵(jian)改變數值,按照所要(yao)設置的(de)年月日時間數值按確定(ding)鍵(jian)確認。
采樣系數(shu)的設(she)(she)定:按(an)確(que)定鍵選擇到(dao)高壓/電流采樣系數(shu)項,此項為(wei)電壓或電流采樣倍率的設(she)(she)定。一(yi)(yi)般出廠(chang)(chang)前設(she)(she)定好了。如需修改,要輸入密(mi)碼(ma)。(密(mi)碼(ma)廠(chang)(chang)家與設(she)(she)備一(yi)(yi)起提供一(yi)(yi)般設(she)(she)定為(wei):188888)
警(jing)告(gao):系統默認(ren)上一次電(dian)(dian)抗器電(dian)(dian)感(gan)(gan)、日(ri)期時間和采(cai)樣系數(shu)設(she)(she)定(ding)值(zhi)。如(ru)果(guo)需改(gai)變要重新設(she)(she)定(ding)。電(dian)(dian)抗器電(dian)(dian)感(gan)(gan)量設(she)(she)定(ding)值(zhi)與實際使用的電(dian)(dian)抗器電(dian)(dian)感(gan)(gan)量不對,會(hui)(hui)導(dao)致(zhi)試(shi)驗報告(gao)中的被試(shi)品電(dian)(dian)容量不準。其他并不會(hui)(hui)影響。采(cai)樣系數(shu)設(she)(she)置(zhi)不正確,會(hui)(hui)導(dao)致(zhi)顯示電(dian)(dian)壓電(dian)(dian)流(liu)不準將很(hen)有可能會(hui)(hui)對被試(shi)品或試(shi)驗設(she)(she)備造成(cheng)損壞。
4、試(shi)驗(yan)(yan)方案菜(cai)單(dan)下有(you)預置保(bao)護(hu)電(dian)流、找頻(pin)(pin)起(qi)始(shi)頻(pin)(pin)率(lv)(lv)、找頻(pin)(pin)結(jie)束頻(pin)(pin)率(lv)(lv)、預定(ding)(ding)(ding)起(qi)始(shi)功率(lv)(lv)四個子菜(cai)單(dan)項,分別設定(ding)(ding)(ding)本次(ci)試(shi)驗(yan)(yan)的(de)保(bao)護(hu)電(dian)流、找頻(pin)(pin)起(qi)始(shi)頻(pin)(pin)率(lv)(lv)、找頻(pin)(pin)結(jie)束頻(pin)(pin)率(lv)(lv)、輸出(chu)起(qi)始(shi)功率(lv)(lv),全部(bu)設定(ding)(ding)(ding)完成后,觸按返還(huan)鍵(jian)進入預置試(shi)驗(yan)(yan)電(dian)壓(ya)和預置試(shi)驗(yan)(yan)時間(jian)設置菜(cai)單(dan)。
可以分3段(duan)時(shi)間設(she)置試驗(yan)電壓和試驗(yan)時(shi)間, 實際試驗(yan)時(shi),若設(she)定為自動試驗(yan), 裝置將(jiang)按設(she)定的3段(duan)電壓及時(shi)間,按順(shun)序分別加壓, 全部完成后自動退出.
如果(guo)**段(duan)電壓(ya)(ya)設(she)為0, 或時間設(she)為0, 那么執行完(wan)**段(duan)試驗(yan)電壓(ya)(ya)加壓(ya)(ya)后(hou)退(tui)出試驗(yan), 只加壓(ya)(ya)**段(duan)設(she)定的(de)電壓(ya)(ya).
如(ru)果(guo)第三(san)(san)段電(dian)壓設(she)為(wei)0, 或時間設(she)為(wei)0, 不執(zhi)行第三(san)(san)段加壓.
試(shi)(shi)驗(yan)方(fang)案設(she)置的設(she)定(ding)(ding):在試(shi)(shi)驗(yan)電(dian)壓(ya)項中,按確定(ding)(ding)單鈕(niu),移動(dong)左右光標(biao)到需要改(gai)變的數位(wei)(wei),按上下單鈕(niu)以改(gai)變當前數位(wei)(wei)的數值(zhi)大小,觸按返回鈕(niu)完(wan)成(cheng)當前數位(wei)(wei)的數值(zhi)設(she)定(ding)(ding),依次選(xuan)擇下一項數值(zhi)的設(she)定(ding)(ding),直至分別完(wan)成(cheng)試(shi)(shi)驗(yan)時間、起始頻(pin)率、起始功率的設(she)置,方(fang)可完(wan)成(cheng)本次試(shi)(shi)驗(yan)的試(shi)(shi)驗(yan)方(fang)案設(she)置的設(she)定(ding)(ding)。
出廠(chang)默認(ren)值:試驗電壓(ya) 20kV、加壓(ya)時間 2min、激勵(li)強度(du) 2%、輸出電流(liu)20A、頻(pin)率范圍30-300Hz。
5、實用(yong)工具菜單下有
頻率計算:在實驗前可對諧振頻率進(jin)行計算。只(zhi)需輸入具體參與試驗的電感、電容(rong)值并按(an)確定鍵試驗頻率即(ji)直接生(sheng)成。
6、開(kai)始(shi)試(shi)驗菜(cai)(cai)單下有自動試(shi)驗模(mo)式和手(shou)動試(shi)驗模(mo)式兩種子菜(cai)(cai)單可供選擇。
按確認鍵(jian)進入所選試驗(yan)步驟(zou).
自動(dong)試驗(yan)模式(shi)的操作:選中自動(dong)試驗(yan)模式(shi)后,觸按菜單(dan)鈕進入(ru)正在自動(dong)尋找諧(xie)振(zhen)點菜單(dan)項(xiang),裝置(zhi)在設定(ding)的頻率(lv)(lv)范(fan)圍內自動(dong)尋找諧(xie)振(zhen)點(如果被試品電容(rong)C和(he)電抗器電感L的實際諧(xie)振(zhen)頻率(lv)(lv)不在設定(ding)的頻率(lv)(lv)范(fan)圍內,將(jiang)找不到諧(xie)振(zhen)點,此時根(gen)據(ju)需要調整頻率(lv)(lv)范(fan)圍或調整被試品回路的LC參數)。當找到諧(xie)振(zhen)點時,會(hui)有(you)聲音提(ti)示(shi)。
找到(dao)諧(xie)振點后,裝(zhuang)置(zhi)自(zi)動(dong)進入(ru)正(zheng)在(zai)自(zi)動(dong)升壓(ya)菜單項,當(dang)升到(dao)試驗電(dian)壓(ya)設定(ding)的電(dian)壓(ya)時,裝(zhuang)置(zhi)停止加(jia)壓(ya)。
當(dang)裝置升(sheng)到試(shi)驗(yan)(yan)電(dian)壓(ya)(ya)設(she)(she)定的(de)電(dian)壓(ya)(ya)時,設(she)(she)備停止加壓(ya)(ya),自(zi)動進入(ru)正在(zai)加壓(ya)(ya)試(shi)驗(yan)(yan)菜單(dan)項,并自(zi)動記錄試(shi)驗(yan)(yan)的(de)加壓(ya)(ya)時間,當(dang)加壓(ya)(ya)時間到達設(she)(she)定時間時,設(she)(she)備逐步降壓(ya)(ya)退出(chu)試(shi)驗(yan)(yan),完成(cheng)本次試(shi)驗(yan)(yan),進入(ru)試(shi)驗(yan)(yan)結束菜單(dan)項。并可選(xuan)擇保存試(shi)驗(yan)(yan)數(shu)(shu)據或打印試(shi)驗(yan)(yan)數(shu)(shu)據。
試驗時間的一行(xing)顯(xian)(xian)示末端,會顯(xian)(xian)示[一段]或[二段]或[三(san)段]字(zi)樣,表示當(dang)前正在進(jin)行(xing)的加壓試驗是預置的一段,二段或三(san)段.
手(shou)動試(shi)驗(yan)(yan)模(mo)式的(de)操作:選中手(shou)動試(shi)驗(yan)(yan)模(mo)式后觸(chu)按(an)確定鈕(niu),進入正在試(shi)驗(yan)(yan)菜單項;手(shou)動按(an)調(diao)頻(pin)(pin)鈕(niu),對應的(de)光標(biao)隨(sui)之改(gai)變(bian)到(dao)輸出頻(pin)(pin)率(lv)(lv)(lv)項,可以(yi)通(tong)過上下左(zuo)右鍵改(gai)變(bian)頻(pin)(pin)率(lv)(lv)(lv)大小使其試(shi)驗(yan)(yan)電(dian)(dian)壓逐步升高(gao)(gao),當升到(dao)*高(gao)(gao)電(dian)(dian)壓時(shi)(shi),繼(ji)續向(xiang)上或向(xiang)下調(diao)整頻(pin)(pin)率(lv)(lv)(lv)按(an)鈕(niu),直至試(shi)驗(yan)(yan)電(dian)(dian)壓開(kai)始(shi)下降;這時(shi)(shi)反(fan)調(diao)頻(pin)(pin)率(lv)(lv)(lv),試(shi)驗(yan)(yan)電(dian)(dian)壓又逐步回(hui)升,上下回(hui)調(diao)頻(pin)(pin)率(lv)(lv)(lv),從頻(pin)(pin)率(lv)(lv)(lv)的(de)高(gao)(gao)位(wei)(wei)到(dao)低位(wei)(wei)逐位(wei)(wei)調(diao)整*高(gao)(gao)電(dian)(dian)壓值時(shi)(shi)的(de)頻(pin)(pin)率(lv)(lv)(lv)就(jiu)是(shi)當前的(de)諧振頻(pin)(pin)率(lv)(lv)(lv)。
找到(dao)(dao)諧振點后,手動(dong)按(an)(an)電壓(ya)鈕,光標到(dao)(dao)了(le)輸(shu)出(chu)功(gong)率,隨之按(an)(an)上下鍵增(zeng)加輸(shu)出(chu)功(gong)率,試(shi)驗電壓(ya)也(ye)逐(zhu)步升高,當升到(dao)(dao)試(shi)驗電壓(ya)設定(ding)電壓(ya)值時(shi),裝置停(ting)止加壓(ya),并有屏幕顯(xian)示提示和聲(sheng)音提示;自(zi)動(dong)進(jin)入正(zheng)在加壓(ya)試(shi)驗菜(cai)單(dan)項,并自(zi)動(dong)記錄試(shi)驗的加壓(ya)時(shi)間,當到(dao)(dao)達加壓(ya)時(shi)間設定(ding)時(shi)間時(shi),設備逐(zhu)步降壓(ya)退出(chu)試(shi)驗,完成(cheng)本次試(shi)驗,進(jin)入試(shi)驗結束菜(cai)單(dan)項。
注意:在調(diao)(diao)節頻率(lv)調(diao)(diao)整(zheng)鈕的(de)(de)過程(cheng)中,觸(chu)按左(zuo)右鈕,可以(yi)改(gai)變(bian)頻率(lv)調(diao)(diao)節的(de)(de)速(su)度(du)實(shi)(shi)現粗細調(diao)(diao)的(de)(de)切(qie)換。在調(diao)(diao)節電(dian)壓(ya)(ya)調(diao)(diao)整(zheng)鈕的(de)(de)過程(cheng)中,向下觸(chu)按左(zuo)右鈕,可以(yi)改(gai)變(bian)電(dian)壓(ya)(ya)的(de)(de)升降的(de)(de)速(su)度(du)實(shi)(shi)現粗細調(diao)(diao)的(de)(de)切(qie)換。觸(chu)按調(diao)(diao)頻、調(diao)(diao)壓(ya)(ya)鈕,實(shi)(shi)現調(diao)(diao)頻與(yu)調(diao)(diao)壓(ya)(ya)間的(de)(de)切(qie)換。
7、進入試驗記(ji)錄查詢菜單項,查詢以往和(he)當前(qian)試驗數據(ju)。選擇(ze)上(shang)下鍵翻看(kan)前(qian)一(yi)組(zu)數據(ju)后一(yi)組(zu)數據(ju);選擇(ze)左(zuo)右鍵可(ke)選擇(ze)打印或刪除當前(qian)頁的(de)內容。
125/456為試(shi)(shi)驗數(shu)(shu)據庫(ku)指針,分子是(shi)試(shi)(shi)驗數(shu)(shu)據的(de)在數(shu)(shu)據庫(ku)的(de)順序數(shu)(shu),分母是(shi)當前的(de)數(shu)(shu)據總數(shu)(shu),*多可(ke)儲存(cun)999組試(shi)(shi)驗數(shu)(shu)據。
8、裝置(zhi)和(he)試驗狀態(tai)菜(cai)單提示(shi):設備的使用和(he)升壓(ya)和(he)耐壓(ya)試驗過(guo)程中,如果(guo)出現影響(xiang)試驗設備、被試驗設備以(yi)及操作人的**情況,設備可能出現自(zi)動(dong)保護(hu)轉臺,并在屏幕(mu)有相應的提示(shi)。
不(bu)能諧振:如果(guo)諧振點(dian)(dian)不(bu)在諧振頻率(lv)設置的范圍內;系統連線不(bu)正(zheng)確(que)等(deng)現象,裝(zhuang)置將找不(bu)到諧振點(dian)(dian),這時裝(zhuang)置和試驗狀態(tai)菜單中(zhong)的不(bu)能諧振項被(bei)反白(bai)并閃爍。
輸(shu)(shu)出(chu)(chu)保護:如果裝(zhuang)置的(de)電源輸(shu)(shu)出(chu)(chu)電流大于輸(shu)(shu)出(chu)(chu)保護設(she)定的(de)電流值,裝(zhuang)置自動保護,這時(shi)裝(zhuang)置和試(shi)驗狀態菜單中(zhong)的(de)輸(shu)(shu)出(chu)(chu)保護項被(bei)反白并閃爍。
試驗(yan)中止:如果在(zai)試驗(yan)升壓或加壓過程出現(xian)閃(shan)絡現(xian)象,裝(zhuang)(zhuang)置自動保護,這時裝(zhuang)(zhuang)置和(he)試驗(yan)狀態菜單中的輸出保護項被反白并閃(shan)爍。
9、試驗幫助內容包(bao)括五大項分別為:1.版本信息(xi)2.接線示意3.使用說明4.常見(jian)問(wen)題(ti)5.參考資(zi)料.如常見(jian)問(wen)題(ti)FAQ分五幅(fu)畫面顯示、各種被試品(pin)電力電纜、變壓器、發(fa)電機電容參數的查詢:
接線示(shi)意圖:
10、設(she)備出廠參(can)數(shu)設(she)置(zhi)是生產廠家的(de)出廠設(she)置(zhi)參(can)術(shu)和校驗參(can)數(shu),不適當的(de)設(she)置(zhi)和修(xiu)改(gai)會(hui)影響(xiang)設(she)備性能和高壓試驗的(de)**性,未經廠家授權密(mi)碼,無(wu)法修(xiu)改(gai)。
警告(gao):正常試(shi)驗(yan)狀態下,按(an)返(fan)回鍵即可中止(zhi)(zhi)試(shi)驗(yan)。中止(zhi)(zhi)或結束試(shi)驗(yan)后,應分離刀(dao)閘切斷電源。在升(sheng)壓(ya)或加(jia)壓(ya)過程中,非緊急情況,不要按(an)下急停(ting)鍵。
六、本說明書的(de)專屬名(ming)詞的(de)定義
自(zi)(zi)動(dong)(dong)試(shi)驗:高壓(ya)試(shi)驗全過(guo)程(cheng)由主機按程(cheng)序和預置參數(shu)自(zi)(zi)動(dong)(dong)完(wan)成。
自(zi)動(dong)調諧:調諧由主(zhu)機按(an)程序自(zi)動(dong)完成,升壓手動(dong)完成。
手(shou)動試驗(yan):尋找諧(xie)振點和(he)升壓均為手(shou)動,通過(guo)面(mian)板旋鈕(niu)完(wan)成。
系統參數設置是指(zhi)對設備部件(jian)參數的設置。
試驗(yan)參數設置是指對試驗(yan)過(guo)程參數的設置。
試(shi)驗(yan)(yan)模(mo)(mo)式(shi)選擇是指(zhi)對試(shi)驗(yan)(yan)模(mo)(mo)式(shi)的選擇。
試驗結果(guo)查詢(xun)是指對試驗數據(ju)的(de)查詢(xun)。
分(fen)壓器變比是指對分(fen)壓器的分(fen)壓比設置。
電(dian)抗(kang)器電(dian)感是指對電(dian)抗(kang)器電(dian)抗(kang)值(zhi)的設置。
激勵(li)變(bian)變(bian)比(bi)是指對勵(li)磁變(bian)壓(ya)器的變(bian)比(bi)設置(zhi)。
設置電(dian)壓(ya)是(shi)高壓(ya)試驗時的保護電(dian)壓(ya)設置。
試(shi)驗(yan)(yan)電壓是高壓試(shi)驗(yan)(yan)時的(de)試(shi)驗(yan)(yan)電壓。
加壓(ya)時間(jian)是施(shi)加試驗電壓(ya)的時間(jian)。
激勵強(qiang)度是指(zhi)主機電源輸出(chu)的大小。
輸出電流(liu)是主機電源的(de)輸出電流(liu)。
頻率范(fan)圍是試驗的頻率范(fan)圍。
自動(dong)試驗(yan)模式是指試驗(yan)過程全部自動(dong)完成。
自動調(diao)諧(xie)(xie)模式是指自動尋找諧(xie)(xie)振點后,手(shou)動加壓完成試驗。
手動試(shi)驗模(mo)式全部由人(ren)工完成試(shi)驗過程。
未接地線主機電(dian)源為接地。
不能諧振未能找到諧振點(dian)。
輸(shu)出保護主機電(dian)源(yuan)輸(shu)出電(dian)流(liu)大于整定電(dian)流(liu)。
試驗中止指在升壓或加壓過程裝置自(zi)動保護。
設備(bei)(bei)出廠參(can)數(shu)設置(zhi)是廠家對設備(bei)(bei)有關參(can)數(shu)的(de)設置(zhi)。
確認鍵:確認當(dang)前操作(zuo)。
返回鍵(jian):返回上**菜單。
七、變頻電源技術參數:
1.額定輸出容量:15kvA;
2.儀器電源:220v±10% 50Hz;
功率電源(yuan):380v±10% 50Hz;
3.額定輸(shu)入電流:39.5A;
4.額定(ding)(ding)輸(shu)出電(dian)壓(ya)(ya):0-340v可調、單相、輸(shu)出電(dian)壓(ya)(ya)不(bu)穩定(ding)(ding)度0.05%;
5.額定(ding)輸出電流:44A;
6.頻率調節范圍:25~320Hz;
7.額定(ding)容量下(xia)連續運行為規定(ding)工(gong)作(zuo)時(shi)間下(xia)*高溫升(sheng)≤60K;
8.顯示以下(xia)參(can)數(shu):
a.經變頻輸(shu)出(chu)的(de)頻率、電(dian)壓、電(dian)流;
b.過壓(ya)保(bao)護電壓(ya)值(zhi),并可任意(yi)整定(ding),當成套裝(zhuang)置(zhi)的輸出(chu)電壓(ya)值(zhi)達到保(bao)護整定(ding)時,可自動(dong)切除成套裝(zhuang)置(zhi);
c.過流保(bao)護(hu):當(dang)調頻(pin)電源(yuan)的輸出電流達到保(bao)護(hu)整定值(zhi)時,可自動切(qie)除成套裝置;
d.擊穿保護(hu):當高壓側(ce)發生對地閃(shan)絡時,可自動切(qie)除成套裝(zhuang)置,裝(zhuang)置帶有隔離裝(zhuang)置,可確保設備和人身不受損害;
e.具有全(quan)電壓(ya)輸出保(bao)護,在(zai)調壓(ya)過程中,一旦(dan)調壓(ya)失控,調頻電源立(li)即閉鎖;
9.可實現以下(xia)操(cao)作:
a.頻(pin)(pin)率的調(diao)節,上升和下降頻(pin)(pin)率調(diao)節分(fen)粗調(diao)和細調(diao)兩種,并可自動尋找試驗(yan)諧(xie)振點,保證諧(xie)振頻(pin)(pin)率在整個(ge)試驗(yan)過程中(zhong)不發生漂移(yi);
b.帶有設(she)置(zhi)電(dian)壓、設(she)置(zhi)時間,電(dian)壓自(zi)動上(shang)升到設(she)置(zhi)值而停止(zhi)并自(zi)動計時;
c.帶有各(ge)種(zhong)保護功能的(de)整定按鈕,可在面板上對各(ge)種(zhong)保護值(zhi)進(jin)行整定;
d.帶有手動(dong)試驗(yan)功能和自動(dong)試驗(yan)功能;
e.帶有試(shi)驗(yan)數據打印功能。
八(ba)、勵磁變壓器技術參數(shu):
1.結構形(xing)式:干式;
2.額定容量:15kVA;
3.輸入電壓:0~340V;
4.輸出電壓(ya):四組并聯(lian)3.75KV;四組串(chuan)聯(lian)15KV;二串(chuan)二并7.5KV;
5.輸出(chu)電流(liu):四(si)(si)組(zu)并聯(lian)(lian)4A;四(si)(si)組(zu)串聯(lian)(lian)1A;二串二并2A;
6.工作頻率范(fan)圍:30~300Hz;
勵磁變(bian)壓(ya)器的接線端子,如圖所(suo)示:
1.輸出端尾—與(yu)接(jie)地端連接(jie)。
2.輸出端頭—與電抗(kang)器連接。
3.接地端—與變頻電源、分壓器及被(bei)試品共同接地。
4.輸入端(duan)—接調頻電源(yuan)功率(lv)輸出端(duan)。
九(jiu)、諧振電(dian)抗器(qi)技術(shu)參數(shu):
額定容(rong)量:55KVA;
額定電(dian)壓:55kV;
額定電流(liu):1.5A;
電 感 量:160H;
品質因(yin)數:Q≥30
采用環氧干式。
7.接線端(duan)了如圖(tu)所(suo)示:
a.高壓(ya)側接線端子—與被試品(pin)高壓(ya)端連接。
b.低(di)壓側接線端子—與勵磁變輸出端連(lian)接。
c.多臺電(dian)抗器串聯(lian)時上節(jie)的(de)低壓(ya)側與下節(jie)高壓(ya)側連(lian)接。諧振電(dian)抗器采用多臺串聯(lian)或并聯(lian)的(de)連(lian)接方式。
8.額定容(rong)量下連續(xu)運行為規定工作時間下,電抗器對空氣的溫升(sheng)不大于60K;
9.性能及特點:電(dian)(dian)抗(kang)器(qi)設計(ji)干式、環(huan)(huan)氧澆鑄,電(dian)(dian)抗(kang)器(qi)可以(yi)自由(you)方便疊裝(zhuang)。環(huan)(huan)氧樹脂絕緣筒外(wai)殼(ke),具有足夠(gou)的電(dian)(dian)氣(qi)、機(ji)械強度,必(bi)要(yao)的散熱(re)能力(li)以(yi)及油熱(re)脹冷(leng)縮(suo)的裕度。外(wai)殼(ke)上下蓋板(ban),顏色為(wei)橘紅(hong)色。
十、電容分(fen)壓器技(ji)術參數:
額定電壓:200kV;
工作(zuo)頻率:30~300Hz;
分壓比:2000:1;
分壓比誤差:1%;
電容分壓器接(jie)線端子如圖所(suo)示:
高壓端—與電抗器高壓側及被試品高壓側相連。
測量插(cha)座(zuo)—采用專(zhuan)配的測量電纜與控制箱背(bei)板測量輸入端連接(jie)。
接地端—采用專配接地線(xian)按(an)接線(xian)圖指示(shi)接地。
4.性能(neng)及特點:
a.額定電壓下(xia)可連(lian)續(xu)運行(xing)2小時。
b.在30~300Hz范圍內,其精度和穩定度保持不變。
c.在(zai)20℃溫度下電(dian)容分(fen)壓器介質損耗值≤0.0025
d.電容分壓器(qi)配有(you)(you)支(zhi)撐底架,具(ju)有(you)(you)足夠(gou)的穩定性。
e.電壓(ya)測量(liang)通過專用測試引線引至調頻(pin)電源進行(xing)測量(liang)。
試驗接線(xian)圖:
110kv主變(bian)、GIS試驗接線
35kv電纜試驗接線圖
10kv電(dian)纜試驗接線(xian)圖(tu)
十二、設備保存和維護
1、存放(fang)于干燥(zao)、清潔場地(di),防止(zhi)雨(yu)水、灰塵(chen)進入部件內部;
2、如若長期(qi)不使用(yong),正常(chang)(chang)天氣至少2個月應(ying)通(tong)(tong)電一(yi)次(ci)時(shi)(shi)間不少于半小(xiao)時(shi)(shi),雨季(ji)及潮(chao)濕(shi)期(qi)應(ying)每(mei)隔一(yi)個月通(tong)(tong)電一(yi)次(ci),通(tong)(tong)電時(shi)(shi)間半小(xiao)時(shi)(shi),以驅除設(she)備內的(de)潮(chao)氣防止(zhi)電子元(yuan)器件的(de)銹(xiu)蝕,影響正常(chang)(chang)使用(yong)。
3、定期檢查裝置各部件,確保各接頭緊固(gu)無松動(dong);
4、更換(huan)打(da)印紙(zhi),機器采用熱敏打(da)印紙(zhi)并且是前換(huan)紙(zhi)式當需要換(huan)紙(zhi)時只要按POST鍵鈕打(da)印紙(zhi)艙門(men)就(jiu)會打(da)開可以將新(xin)打(da)印紙(zhi)裝入;
十三、常見故障排除
故障現象
|
發 生 原 因
|
排 除 方 法
|
找不到諧振點
|
接線有(you)誤。
輸出開關未開,;
3、做GIS時PT二次回路(lu)未打開(kai);
4、試(shi)品Q值太低;
5、起始激勵功率太低;
6、試驗回路(lu)(lu)有短路(lu)(lu)現象;
7、找頻范圍不對。
|
退出(chu)試(shi)驗(yan)狀態,合上(shang)輸出(chu)開關,檢查接(jie)線;打開PT二(er)次(ci)回(hui)路;
調高起(qi)始功率(∠30%);
用兆歐表測量試品絕緣
重新設置找頻范(fan)圍
|
諧振后,電(dian)壓升(sheng)不(bu)上去
|
1、試品(pin)Q值太低;
2、激勵電(dian)壓(ya)不(bu)夠(gou);
3、電(dian)抗器底(di)部有鐵(tie)磁物體(ti);
4、3次諧(xie)波諧(xie)振(zhen)。
|
檢查試品(pin);
改變激勵變壓器繞組(zu)接法(fa),提高勵磁(ci)電壓
絕緣筒(tong)架(jia)高(gao)電抗器或(huo)離開鐵磁物體。
|
主機自(zi)動復位
|
供電電源容(rong)量不夠(gou);
電(dian)源引線過長或線徑過小(xiao);
接(jie)頭處接(jie)觸**;
供電電壓波(bo)動(dong);
按鍵(jian)死接(jie)觸。
|
增加供電(dian)電(dian)源容量;
換較粗導線,減(jian)小導線長度;
檢查接頭(tou);
減小供電(dian)電(dian)壓波動。
|
開(kai)機后(hou)線路跳閘
|
線路漏電(dian)保護器較為(wei)敏感;
空氣開關容量不(bu)夠。
|
跨過漏(lou)電保護(hu)器或(huo)空氣開關的(de)接線;
改換較大容量的空氣開關。
|
電壓跌落
|
試品放(fang)電或擊穿
|
檢(jian)查試品
|
輸出短(duan)路
|
電流超(chao)過本機限流值。
|
檢查接線和試品。
|
試品電壓不(bu)準(zhun)
|
分(fen)壓(ya)比設置錯誤或分(fen)壓(ya)器信號(hao)傳(chuan)輸有問題。
|
重設分壓比或檢查分壓器接線。
|
電壓閃變
|
試驗電壓劇烈波動,變化率超過本機(ji)限定值。
|
檢查供電電源(yuan)電壓穩定性或(huo)試品(pin)參數的(de)變化。
|
回(hui)路無電流(liu)
|
|
檢查接線和(he)試品。
|
未接好(hao)地線
|
|
檢查接(jie)地(di)線(xian)和地(di)樁,按說明書要求連接(jie)。
|
試(shi)品過(guo)電壓
|
手動升壓太快(kuai)或失控。
|
改(gai)變調壓(ya)步距或改(gai)用自動(dong)升壓(ya) 。
|
系統不諧振(zhen)
|
接(jie)線(xian)有誤或試品Q值(zhi)太低。
|
檢查接(jie)線和試(shi)品(pin)
|
十四(si)、常用設備(bei)資料(liao)參考
交(jiao)聯聚乙(yi)烯電纜單位長度(du)電容量
電纜導(dao)體截(jie)面積(ji)(平(ping)方毫米(mi))
|
電(dian) 容 (μ/km)
|
YJV、YJLV
|
YJV、YJLV
|
YJV、YJV、YJLV
|
YJV、YJLV
|
YJV、YJLV
|
6/6kV、6/10kV
|
8.7/10kV、8.7/15kV
|
12/35kV
|
21/35kV
|
26/35kV
|
1×35
|
0.212
|
0.173
|
0.152
|
|
|
1×50
|
0.237
|
0.192
|
0.166
|
0.118
|
0.114
|
1×70
|
0.270
|
0.217
|
0.187
|
0.131
|
0.125
|
1×95
|
0.301
|
0.240
|
0.206
|
0.143
|
0.135
|
1×120
|
0.327
|
0.261
|
0.223
|
0.153
|
0.143
|
1×150
|
0.358
|
0.284
|
0.241
|
0.164
|
0.153
|
1×185
|
0.388
|
0.307
|
0.267
|
0.180
|
0.163
|
1×240
|
0.430
|
0.339
|
0.291
|
0.194
|
0.176
|
1×300
|
0.472
|
0.370
|
0.319
|
0.211
|
0.190
|
1×400
|
0.531
|
0.418
|
0.352
|
0.231
|
0.209
|
1×500
|
0.603
|
0.438
|
0.388
|
0.254
|
0.232
|
1×600
|
0.667
|
0.470
|
0.416
|
0.287
|
0.256
|
2、交聯聚乙烯電纜(lan)單(dan)位長(chang)度電容量
電纜導體截(jie)面積(平方毫米)
|
電 容(rong) (μF/km)
|
YJV、YJLV
|
YJV、YJLV
|
YJV、YJV、YJLV
|
YJV、YJLV
|
YJV、YJLV
|
6/6kV、6/10kV
|
8.7/10kV、8.7/15kV
|
12/35kV
|
21/35kV
|
26/35kV
|
3×35
|
0.212
|
0.173
|
0.152
|
|
|
3×50
|
0.237
|
0.192
|
0.166
|
0.118
|
0.114
|
3×70
|
0.270
|
0.217
|
0.187
|
0.131
|
0.125
|
3×95
|
0.301
|
0.240
|
0.206
|
0.143
|
0.135
|
3×120
|
0.327
|
0.261
|
0.223
|
0.153
|
0.143
|
3×150
|
0.358
|
0.284
|
0.241
|
0.164
|
0.153
|
3×185
|
0.388
|
0.307
|
0.267
|
0.180
|
0.163
|
3×240
|
0.430
|
0.339
|
0.291
|
0.194
|
0.176
|
3×300
|
0.472
|
0.370
|
0.319
|
0.211
|
0.190
|
3×400
|
0.531
|
0.418
|
0.352
|
0.231
|
0.209
|
3×500
|
0.603
|
0.438
|
0.388
|
0.254
|
0.232
|
3×600
|
0.667
|
0.470
|
0.416
|
0.287
|
0.256
|
3、交聯聚乙烯(xi)電纜單位長度(du)電容(rong)量(liang)
電纜導(dao)體(ti)截(jie)面積(ji)(平方毫米)
|
電 容 (μF/km)
|
YJV、YJLV
|
YJV、YJLV
|
64/110kV
|
128/220kV
|
3×240
|
0.129
|
|
3×300
|
0.139
|
|
3×400
|
0.156
|
0.118
|
3×500
|
0.169
|
0.124
|
3×630
|
0.188
|
0.138
|
3×800
|
0.214
|
0.155
|
3×1000
|
0.231
|
0.172
|
3×1200
|
0.242
|
0.179
|
3×1400
|
0.259
|
0.190
|
3×1600
|
0.273
|
0.198
|
3×1800
|
0.284
|
0.297
|
3×2000
|
0.296
|
0.215
|
3×2200
|
|
0.221
|
3×2500
|
|
0.232
|
4、60kV級(ji)全絕緣變壓(ya)器(qi)的電容(pF)
類 型
|
變 壓 器 容 量 kVA
|
630
|
2000
|
3150
|
6300
|
8000
|
1600
|
高壓-地
|
2700
|
4100
|
4600
|
5900
|
7000
|
8200
|
低壓-地
|
4200
|
6600
|
7900
|
10000
|
11000
|
15300
|
對于表中(zhong)沒有的(de)產品,可根據表中(zhong)的(de)上、下容(rong)量近似地估算。同容(rong)量的(de)雙繞(rao)組(zu)(zu)變壓器,其繞(rao)組(zu)(zu)電(dian)容(rong)要比三繞(rao)組(zu)(zu)產品小。
5、110kV級中性點分(fen)級絕緣變壓器的電容(rong)(pF)
類 型
|
變 壓(ya) 器 容 量kVA
|
50000
|
31500
|
20000
|
10000
|
5600
|
高壓(ya)-中壓(ya)、低壓(ya)、地(di)
|
14200
|
11400
|
8700
|
6150
|
4200
|
中壓-高壓、低壓、地
|
24800
|
11800
|
13200
|
9600
|
-
|
低(di)壓(ya)-高壓(ya)、中壓(ya)、地
|
19300
|
19300
|
12000
|
9400
|
6800
|
6、220kV級中性點非(fei)全(quan)級絕緣部(bu)分變(bian)壓器的電容(pF)
試 品(pin) 型(xing) 號
|
SEPSL-63000
|
SSPSL-120000
|
SSPSL-240000
|
類 型(xing)
|
高壓-中壓、低(di)壓及地
|
12100
|
13500
|
17050
|
中(zhong)壓-高壓、低壓及地
|
18500
|
19700
|
23260
|
低壓(ya)-高(gao)壓(ya)、中壓(ya)及地(di)
|
18200
|
23600
|
29940
|
試(shi) 品 型 號
|
SFPL-240000
|
SFP-360000
|
SFPSZL-120000
|
類 型(xing)
|
高(gao)壓(ya)(ya)-中壓(ya)(ya)、低壓(ya)(ya)及(ji)地
|
32230
|
33910
|
38020
|
中(zhong)壓(ya)-高壓(ya)、低壓(ya)及地(di)
|
-
|
-
|
23260
|
低壓(ya)-高壓(ya)、中壓(ya)及(ji)地
|
22470
|
23790
|
22160
|
7、油浸(jin)式電力變壓器交流試驗電壓
額定電壓
(k V)
|
*高(gao)工作
電壓(k V)
|
線端交流試驗電(dian)壓值(zhi)(kV)
|
中性點(dian)交流試(shi)驗電壓值(kV)
|
全部(bu)更換繞組
|
部分更換繞組或交接(jie)
|
全(quan)部(bu)更(geng)換繞組
|
部分更(geng)換繞組或交接
|
<1
|
≤1
|
3
|
2.5
|
3
|
2.5
|
3
|
3.5
|
18
|
15
|
18
|
15
|
6
|
6.9
|
25
|
21
|
25
|
21
|
10
|
11.5
|
35
|
30
|
35
|
30
|
15
|
17.5
|
45
|
38
|
45
|
38
|
20
|
23.0
|
55
|
47
|
55
|
47
|
35
|
40.5
|
85
|
72
|
85
|
72
|
110
|
126.0
|
200
|
170(195)
|
95
|
80
|
220
|
252.0
|
360
|
306
|
85
|
72
|
395
|
336
|
(200)
|
(170)
|
500
|
550.0
|
630
|
536
|
85
|
72
|
680
|
578
|
140
|
120
|
8、部分型號發電(dian)機(ji)定子繞組(zu)的(de)單相對地電(dian)容量
類別
|
發 電 機
|
型號
|
生(sheng)產廠家
|
額定容(rong)量(MW)
|
額(e)定電壓(kV)
|
相電容(mF)
|
火
力(li)
發(fa)
電
機
|
QFS-125-2
|
上海(hai)電機(ji)廠
|
125
|
13.8
|
0.08-0.12
|
QFSN-200-2
|
哈(ha)爾濱電機廠
|
200
|
15.75
|
0.19-0.21
|
QFQS-200-2
|
東方電機廠
|
200
|
15.75
|
0.1928-0.21
|
QFQS-200-2
|
北(bei)京重型電機廠
|
200
|
15.75
|
0.18-0.19
|
QFS-300-2
|
上海電機廠
|
300
|
18.0
|
0.16-0.20
|
QFSN-300-2
|
上海電機廠
|
300
|
18.0
|
0.18-0.20
|
ATB-2
|
美國GE公司
|
352
|
23.0
|
0.268(設計(ji)值)
|
TBB-320-2
|
(前蘇聯)
|
320
|
20.0
|
0.31
|
2-105×234
|
美國西屋公司(si)
|
600
|
20.0
|
0.2(工廠(chang)試(shi)驗值)
|
50WT23E-138
|
ABB
|
600
|
22.0
|
0.253(設計值)
|
水 發
力(li) 電
機
|
|
|
72.5 - 85
|
10.5
|
0.694
|
|
|
300
|
15.75
|
1.7-2.5
|
|
|
400
|
18.0
|
2-2.5
|
9、同步發電機定子繞組交流試(shi)驗電壓
1
|
全部更(geng)換(huan)定子繞組(zu)并(bing)修好(hao)后的試驗電壓
|
容量kW或(huo)kVA
|
小(xiao)于10000
|
10000及(ji)以上(shang)
|
額定(ding)電壓Un (V)
|
36以(yi)上
|
6000以下
|
6000~18000
|
18000以(yi)上
|
試驗(yan)電(dian)壓V
|
2Un+1000但*低為1500
|
2.5Un
|
2Un
+3000
|
按專門協(xie)議(yi)
|
2
|
大(da)修(xiu)前或局部更換(huan)定子繞組(zu)并修(xiu)好后的試驗電壓
|
運行20年及以下者
|
1.5 Un
|
運行20年以上與架空線(xian)路(lu)直(zhi)接(jie)連接(jie)者
|
1.5 Un
|
運行20年以(yi)上不與架(jia)空線路直接(jie)連接(jie)者
|
(1.3~1.5)Un
|
十(shi)五、設備成套(tao)性:
變頻電源(yuan) 1臺
勵磁變壓器(qi) 1臺
電抗器 4臺
電容分壓器 1臺
附件及(ji)測試(shi)線 1套
支(zhi)架 15KV 1只
均壓罩(zhao) 200KV 2只
絕緣底(di)板 2塊
一(yi)、產品概述
YDQC系列輕型交直流(liu)高(gao)(gao)(gao)壓(ya)試(shi)驗(yan)變(bian)壓(ya)器(qi)(qi)是(shi)在同類產(chan)(chan)品(pin)YDJ(G)型高(gao)(gao)(gao)壓(ya)試(shi)驗(yan)變(bian)壓(ya)器(qi)(qi)的(de)基礎上(shang),按試(shi)驗(yan)變(bian)壓(ya)器(qi)(qi)國家標準ZBK41006—89要求,經改(gai)進后生產(chan)(chan)的(de)一種新型產(chan)(chan)品(pin),本系列產(chan)(chan)品(pin)具有(you)體積小、重量輕、結構(gou)緊湊、功能齊全、使用方(fang)便等特點。實用于(yu)電力、工礦、科研等部(bu)門,對各(ge)種高(gao)(gao)(gao)壓(ya)電氣設備(bei)、電氣元件、絕緣材料進行(xing)工頻耐(nai)壓(ya)試(shi)驗(yan)和直流(liu)泄漏試(shi)驗(yan),是(shi)高(gao)(gao)(gao)壓(ya)試(shi)驗(yan)中(zhong)必不可少(shao)的(de)儀器(qi)(qi)。
二(er)、產品結構
YDQC系列輕型高(gao)壓(ya)(ya)(ya)試驗(yan)變(bian)壓(ya)(ya)(ya)器鐵芯(xin)(xin)為單框式(shi)。線圈采用(yong)同芯(xin)(xin)圓筒多層塔式(shi)結構(gou)(gou),初級低壓(ya)(ya)(ya)繞組繞在(zai)鐵芯(xin)(xin)上(shang),次級高(gao)壓(ya)(ya)(ya)繞組繞在(zai)低壓(ya)(ya)(ya)繞組外側(ce),這種同軸布置(zhi)減少了(le)繞組間的(de)藕合(he)損耗。高(gao)壓(ya)(ya)(ya)硅(gui)堆用(yong)特(te)殊工藝(yi)封裝在(zai)套管(guan)內(nei),產(chan)品的(de)外殼制成與(yu)器芯(xin)(xin)配合(he)較佳的(de)八角形結構(gou)(gou),整體外型美觀大方。其內(nei)外部結構(gou)(gou)見圖1。
1-均壓(ya)球;2-硅堆短(duan)路(lu)桿;3-高(gao)壓(ya)套管(guan);4-油(you)閥;5-殼體;6、7-調整電壓(ya)輸入a、x端子(zi);8、9-儀表(biao)測量(liang)(liang)E、F端子(zi);10-高(gao)壓(ya)尾X端子(zi);11-變壓(ya)器外殼接地端;12-高(gao)壓(ya)輸出A端子(zi);13-高(gao)壓(ya)整流(liu)硅堆;14-內部均壓(ya)環(huan);15-變壓(ya)器鐵芯(xin);16-初(chu)級低壓(ya)繞組;17-測量(liang)(liang)儀表(biao)繞組;18-二次(ci)級高(gao)壓(ya)繞組;19-變壓(ya)器油(you)。
三、工作原理
YDQC系(xi)列輕(qing)型高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)驗變(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)為單相變(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi),聯結組(zu)標號(hao)II。單臺(tai)高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)試(shi)驗變(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)的(de)工作(zuo)過(guo)程,用交流(liu)220V(10KVA以(yi)上為380V)電壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)接入電源控(kong)制(zhi)箱(xiang)(臺(tai)),經電源控(kong)制(zhi)箱(xiang)(臺(tai))內自藕調壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)(50KVA以(yi)上調壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)外附)調節0~200V(10KVA以(yi)上0~400V)電壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)至試(shi)驗變(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)的(de)初級(ji)繞組(zu),根(gen)據電磁感應原理(li),在(zai)試(shi)驗變(bian)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)器(qi)高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)繞組(zu)可獲(huo)得試(shi)驗所(suo)需的(de)高(gao)(gao)電壓(ya)(ya)(ya)(ya)(ya)(ya)(ya)。其工作(zuo)原理(li)圖見圖2所(suo)示。
1、單臺YDQC高壓試驗變壓器工(gong)作原理(li)示意圖
在試驗變(bian)壓器中:a、x為(wei)低(di)壓輸入端(duan);A、X 為(wei)高壓輸出(chu)端(duan);E、F為(wei)儀表測量端(duan)。
2、單臺交直流兩用型高壓試驗變壓器工作原理見圖3。圖中所示:高壓套管內裝有高壓硅堆,串接在高壓回路中作高壓整流,以獲得直流高電壓。當用一短路桿將高壓硅堆短接時,可獲得交流高電壓,其狀態為交流輸出;反之在抽出短路桿時,其狀態為直流輸出。
3、三臺高壓試驗變壓器串激獲得更高電壓原理見圖4,串激高壓試驗變壓器有很大的優越性,因為整個試驗裝置由多個單臺串激式試驗變壓器組成,單臺試驗變壓器有著體積小、重量輕、便于運輸的特點,它既可以串接成高出幾倍的單臺試驗變壓器輸出電壓組合使用,又可以分開單獨使用。整套試驗裝置投資小、經濟實惠。圖3所示:在三臺串激式試驗變壓器串激使用中,單臺試驗變壓器B1、B2、B3的輸出電壓都是U,**、二級的試驗變壓器內部都有一個激磁繞組,分別為A1、C1 和A2、C2。當控制電壓加在第**試驗變壓器B1的初級繞組a1、x1上,激磁繞組A1、C1給予試驗變壓器B2初級繞組供電,**級試驗變壓器B2的激磁繞組A2、C2給試驗變壓器B3的初級繞組供電。由于第**試驗變壓器B1的高壓尾及殼體接地,**、三級的試驗變壓器B2和B3對地有絕緣支架的隔離,這樣試驗變壓器B1、B2、B3對地輸出電壓分別為1U、2U、3U。
B1、B2、B3- 串激式高(gao)壓變壓器(qi);1U、2U、3U-各(ge)級對(dui)地電壓;
PV- 高壓(ya)示值表(KV); ZJ1、ZJ2-絕緣支架。
四、使用(yong)方法及注意事項
1、YDQC高壓(ya)試(shi)(shi)(shi)驗(yan)變(bian)(bian)壓(ya)器(qi)做工(gong)頻耐(nai)壓(ya)試(shi)(shi)(shi)驗(yan)使用接線方法見圖5。做工(gong)頻耐(nai)壓(ya)試(shi)(shi)(shi)驗(yan)前,先根據試(shi)(shi)(shi)驗(yan)變(bian)(bian)壓(ya)器(qi)的(de)(de)(de)額(e)定容量選擇(ze)好限流(liu)電(dian)(dian)阻(zu),(水電(dian)(dian)阻(zu))的(de)(de)(de)阻(zu)值,再根據被試(shi)(shi)(shi)品(pin)(pin)需加的(de)(de)(de)高壓(ya)電(dian)(dian)壓(ya)值調整(zheng)好放電(dian)(dian)球隙的(de)(de)(de)球間(jian)距,為(wei)了提高對被試(shi)(shi)(shi)品(pin)(pin)施加電(dian)(dian)壓(ya)的(de)(de)(de)測(ce)量精度,應在高壓(ya)側接入FRC阻(zu)容分壓(ya)器(qi)來測(ce)量電(dian)(dian)壓(ya)。
R1、R2- 限流電(dian)阻; Qx- 放(fang)電(dian)球隙(xi); Zx- 被試品;
FRC- 阻容分壓器; V- 分壓器高壓表。
按照圖4、結合圖2所進行的工頻耐壓試驗接好工作線路,試驗變壓器的高壓繞阻的X端(高壓尾)、儀表測量繞組的F端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
用三臺試驗變壓器串激做工頻耐壓試驗時、**、三級試驗變壓器的初級繞組X端,儀表測量繞組的F端,以及高壓繞組的X端(高壓尾)均接本級試驗變壓器的外殼,**、三級試驗變壓器的主體必須放置在絕緣支架上。除第**以外、**、三級試驗變壓器的主體不要接地線。其接線方式見圖3所示。
接電源前,電源控制箱(臺)的調壓器必須調到零位。接通電源后,綠色指示燈亮,按一下啟動按鈕,紅色指示燈亮,表示試驗變壓器已接通控制電源,開始升壓。
從零位開始按順時針方向勻速旋轉調壓器手輪升壓。(升壓方式有:快速升壓法,即20S逐級升壓法,慢速升壓法,即60S逐級升壓法,極慢速升壓法供選用)電壓從零開始按選定的升壓速度升到您所需額定試驗電壓的75%后,再以每秒2%額定試驗電壓的速度升到您所需試驗電壓,并密切注意測量儀表的指示以及被試品的情況,被試品施加電壓的時間到后。應在數秒內勻速將調壓器返回,高壓降至1/3試驗電壓以下,按一下停止按鈕,高壓、低壓輸出停止,然后切斷電源線,試驗完畢。
工頻耐(nai)壓(ya)試驗操作過程(cheng)注意(yi)事項
1、試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
2、被試品主要部位應**干凈,保持**干燥,以免損壞被試品和帶來試驗數值的誤差。
3、對大型設備的試驗,一般都應先進行試驗變壓器的空升試驗,即不接試品時升壓至試驗電壓,以便校對好儀表的指示精度,調整好放電球隙的球間距。
4、做耐壓試驗時升壓速度不能過快,并防止突然加壓,例如調壓器不在零位的突然合閘,也不能突然斷電,一般應在調壓器降至零位時分閘。
5、在升壓或耐壓試驗過程中,如發現下列不正常情況,1 電壓、電流表指針擺動很大,2 被試品發出不正常響聲,3 發現絕緣有燒焦或冒煙現象,應立即降壓,切斷電源,停止試驗并查明原因。
6、使用本產品做高壓試驗時,除熟悉本說明書外,還必須嚴格執行國家有關標準和操作規程。
2、YDQ交直(zhi)(zhi)(zhi)流(liu)(liu)兩(liang)用高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)試驗(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)器(qi)做(zuo)直(zhi)(zhi)(zhi)流(liu)(liu)耐(nai)壓(ya)(ya)(ya)(ya)(ya)和泄(xie)漏試驗(yan)(yan)使(shi)用接線方(fang)法見(jian)圖5。由于(yu)是交直(zhi)(zhi)(zhi)流(liu)(liu)兩(liang)用高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)試驗(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)器(qi),應把高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)硅堆短路桿從套(tao)管中(zhong)抽出(chu),使(shi)試驗(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)器(qi)為(wei)直(zhi)(zhi)(zhi)流(liu)(liu)輸出(chu)狀態。做(zuo)直(zhi)(zhi)(zhi)流(liu)(liu)泄(xie)漏試驗(yan)(yan)前,先(xian)根據泄(xie)漏試驗(yan)(yan)中(zhong)輸出(chu)端斷路電(dian)(dian)流(liu)(liu)不超過高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)硅堆的(de)*大整(zheng)流(liu)(liu)為(wei)宜(yi),選擇(ze)好限(xian)流(liu)(liu)電(dian)(dian)阻(zu)(水電(dian)(dian)阻(zu))的(de)阻(zu)值(zhi),再根據被試品(pin)對直(zhi)(zhi)(zhi)流(liu)(liu)高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)波形的(de)要求選擇(ze)好高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)濾(lv)波電(dian)(dian)容的(de)電(dian)(dian)容值(zhi)。為(wei)了提高(gao)(gao)對被試品(pin)施加電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)的(de)測量精度,應在(zai)高(gao)(gao)壓(ya)(ya)(ya)(ya)(ya)側接入FRC阻(zu)容分壓(ya)(ya)(ya)(ya)(ya)器(qi)來測量電(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)。
R- 限流電阻; C- 高壓濾波電容; Zx- 被試品; G- 硅堆短路桿;
FRC- 阻容分壓器;V- 分壓器高壓表;uA- 微安表;D- 高壓整流硅堆。
按照圖5、結合圖3所進行的直流泄漏試驗接好工作線路。試驗變壓器的高壓繞組的X端(高壓尾)、儀表測量繞組的F 端、試驗變壓器的外殼以及電源控制箱(臺)的外殼必須可靠接地。
接電(dian)(dian)源前(qian)、電(dian)(dian)源控制(zhi)箱(臺(tai))的調壓器必須調到零位。接通電(dian)(dian)源后,綠(lv)色(se)指示燈(deng)亮(liang),按一(yi)下啟動按鈕,紅色(se)指示燈(deng)亮(liang),表示試驗變(bian)壓器已接通控制(zhi)電(dian)(dian)源,開(kai)始升壓。
從零位(wei)開始按(an)順時(shi)針方(fang)向勻(yun)速(su)旋(xuan)轉(zhuan)調壓(ya)(ya)器手輪升(sheng)(sheng)壓(ya)(ya)。(升(sheng)(sheng)壓(ya)(ya)方(fang)式有:快速(su)升(sheng)(sheng)壓(ya)(ya)法(fa)(fa)即(ji)20S逐級(ji)升(sheng)(sheng)壓(ya)(ya)法(fa)(fa);慢速(su)升(sheng)(sheng)壓(ya)(ya)法(fa)(fa),即(ji)60S逐級(ji)升(sheng)(sheng)壓(ya)(ya)法(fa)(fa);級(ji)慢速(su)升(sheng)(sheng)壓(ya)(ya)法(fa)(fa)供選用(yong))電(dian)壓(ya)(ya)從零開始按(an)選定(ding)的升(sheng)(sheng)壓(ya)(ya)速(su)度升(sheng)(sheng)到(dao)您所需額定(ding)試(shi)(shi)驗(yan)電(dian)壓(ya)(ya)或額定(ding)直(zhi)流(liu)電(dian)流(liu)下的參考(kao)電(dian)壓(ya)(ya)。試(shi)(shi)驗(yan)中應(ying)嚴密注意直(zhi)流(liu)高(gao)壓(ya)(ya)表、泄漏電(dian)流(liu)表指示(shi)以及被(bei)試(shi)(shi)品(pin)的情況。試(shi)(shi)驗(yan)完畢后,應(ying)訊速(su)均(jun)勻(yun)將高(gao)壓(ya)(ya)降(jiang)至零位(wei),按(an)一下停止按(an)鈕,高(gao)壓(ya)(ya)、低壓(ya)(ya)輸出停止,然后切斷電(dian)源(yuan)。此時(shi)應(ying)用(yong)直(zhi)流(liu)高(gao)壓(ya)(ya)放**給被(bei)試(shi)(shi)品(pin)及試(shi)(shi)驗(yan)裝置本身充分放電(dian)。
直流泄(xie)漏試(shi)驗(yan)操作過(guo)程注意事項
(1)試驗人員應做好責任分工,設定好試驗現場的**距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有專人監護**及觀察被試品狀態工作。
(2)被試品做試驗前,應拆除所有對外連線,并充分放電,主要部位應**干凈,保持**干燥,以免損壞被試品及帶來試驗數值的誤差。
(3)對于大容量試品(電容器、超長電纜等)試驗時應緩慢升壓,防止被試品的充電電流過大而燒壞微安表,必要時應分級加壓分別讀取各電壓下微安表的穩定讀數。
(4)試驗過程中,應嚴密監視被試品、微安表及試驗裝置等,一旦發生閃爍、擊穿等現象應立即降壓,切斷電源,并查明原因。
五、配套(tao)選購產品
下列產品僅供選擇,購買時需另行計價。
1.KZX系列電源控制箱 容量:1KVA-5KVA、輸入電壓:220V
2.KZT系列電源控制臺 容量:10KVA~300KVA輸入電壓:220V或380V
3.數字微安表:SWB-II
4.高壓濾波電容: 0.01MF、40 ~ 100KV
5.高壓直流放**: FBR— 70、140、210KV
6.放電球隙: Q—50、100、150、200、250、500
7.標準試油杯: 400ml
8.折疊式手推車: 150、300型
9.絕緣支架: 50、100、200、300、400KV
10.阻容分壓器: FRC —50、100、150、200KV
11.高壓硅堆: 2DL—150、300、450KV
12.水 電 阻: 50、100
六、主要試驗(yan)設備的選擇
1、試驗變壓器
其高壓側額定電壓應不小于被試品的*高試驗電壓,額定電流不小于被試品的*大電容電流。被試品的電容電流和試驗變壓器所需容量計算式為:
被(bei)試品電容(rong)量Cx可由交流電橋測(ce)出。常用(yong)的(de)被(bei)試品電容(rong)量按表(biao)1選取(qu)。
幾種(zhong)常(chang)用被試(shi)品的電容量(pF) 表1
2、調(diao)壓設備
(1)自藕調壓器。其調壓范圍廣、功率損耗小、波形畸變小、選擇這種調壓方式為*好。自藕調壓器的容量按0.75 ~ 1倍的試驗變壓器的容量選擇,適用于容量為100KVA以下的試驗變壓器的調壓。
(2)感應調壓器。其調壓范圍大,波形畸形小、但結構復雜、價格較貴,當試驗變壓器的容量較大時(如100KVA以上)使用。
3、限流電阻
限流電阻的作用是,當被試品擊穿時,限制斷路電流,從而保護試驗變壓器,防止故障的擴大。其數值以*高試驗電壓為準,按0.5 ~ 1 Ω / V(有效值)選擇,限流電阻可用水電阻。注意水不能充滿玻璃管,應留有余地,以防爆裂。
4、放電球隙
放電球隙的布置方式有垂直和水平兩種,球隙間距S和球的直徑D的關系應保護在0.05D ≤S ≤0.5D范圍內,球隙上的水電阻阻值一般按0.1 ~ 1Ω/V選取,設置放電球隙的目的是為了對重要的被試品起保護作用,可以將由于誤操作或被試品擊穿引起的過電壓限制在允許的范圍內。
七、試驗變壓器(qi)技術指示
型號(hao)
|
容(rong)量(liang)
|
高壓電壓
|
高壓(ya)電流
|
低壓輸(shu)入
|
變(bian)比
|
溫升℃
|
(KVA)
|
(KV)
|
(mA)
|
電壓(V)
|
電(dian)流(A)
|
高(gao)/儀
|
30分鐘
|
YDQC-1.5/50
|
1.5
|
50
|
30
|
200
|
7.5
|
500
|
10
|
YDQC-3/50
|
3
|
50
|
60
|
200
|
15
|
500
|
10
|
YDQC-5/50
|
5
|
50
|
100
|
200
|
25
|
500
|
10
|
YDQC-10/50
|
10
|
50
|
200
|
200
|
50
|
500
|
10
|
YDQC-15/50
|
15
|
50
|
300
|
200
|
75
|
500
|
10
|
YDQC-20/50
|
20
|
50
|
400
|
380
|
53
|
500
|
10
|
YDQC-30/50
|
30
|
50
|
600
|
380
|
79
|
500
|
10
|
YDQC-50/50
|
50
|
50
|
1000
|
380
|
12
|
500
|
10
|
YDQC-5/100
|
5
|
100
|
50
|
200
|
25
|
1000
|
10
|
YDQC-10/100
|
10
|
100
|
100
|
200
|
50
|
1000
|
10
|
YDQC-20/100
|
20
|
100
|
200
|
400
|
50
|
1000
|
10
|
YDQC-30/100
|
30
|
100
|
300
|
400
|
75
|
1000
|
10
|
YDQC-50/100
|
50
|
100
|
500
|
400
|
125
|
1000
|
10
|
YDQC-20/150
|
20
|
150
|
133
|
400
|
50
|
1500
|
10
|
YDQC-30/150
|
30
|
150
|
200
|
400
|
75
|
1500
|
10
|
YDQC-50/150
|
50
|
150
|
333
|
400
|
125
|
1500
|
10
|
YDQC-100/150
|
100
|
150
|
667
|
400
|
250
|
1500
|
10
|
YDQC-50/200
|
50
|
200
|
250
|
400
|
125
|
2000
|
10
|
YDQC-100/200
|
100
|
200
|
500
|
400
|
250
|
2000
|
10
|
YDQC-150/200
|
150
|
200
|
750
|
400
|
375
|
2000
|
10
|
YDQC-200/200
|
200
|
200
|
1000
|
400
|
500
|
2000
|
10
|
YDQC-300/200
|
300
|
200
|
1500
|
400
|
600
|
2000
|
10
|
YDQC-50/300
|
50
|
300
|
170
|
400
|
125
|
3000
|
10
|
YDQC-100/300
|
100
|
300
|
333
|
400
|
250
|
3000
|
10
|
YDQC-150/300
|
150
|
300
|
500
|
400
|
375
|
3000
|
10
|
YDQC-200/300
|
200
|
300
|
667
|
400
|
500
|
3000
|
10
|
YDQC-300/300
|
300
|
300
|
3000
|
500
|
600
|
3000
|
10
|
1、使用環境條件
環境溫度不高于+40℃、不低于—20℃;空氣相對濕度不大于90%;海拔高度不超過2000米;
2、工作電壓
電源控制箱(臺)輸入電壓為工頻220V或380V、相對誤差不超過±10%;(具體使用電壓根據用戶所定試驗變壓器規格選取)
八、隨貨文件
YDQC 系列試驗變壓器產品說明書 1份
產品出廠試驗報告 1份
產品合格證 1份
裝箱單 1份
一、概述
YDQ系列高(gao)(gao)壓(ya)(ya)(ya)試驗(yan)(yan)變(bian)壓(ya)(ya)(ya)器是(shi)(shi)根據《試驗(yan)(yan)變(bian)壓(ya)(ya)(ya)器》標準(zhun)(zhun),在油浸式試驗(yan)(yan)變(bian)壓(ya)(ya)(ya)器的(de)(de)(de)基(ji)礎(chu)上而設(she)計生產(chan)的(de)(de)(de)。SF6氣(qi)體具有良好的(de)(de)(de)電(dian)(dian)(dian)氣(qi)絕(jue)緣性能及優異的(de)(de)(de)滅弧性能,其(qi)耐壓(ya)(ya)(ya)強(qiang)度(du)為(wei)同一(yi)壓(ya)(ya)(ya)力(li)下(xia)氮(dan)氣(qi)的(de)(de)(de)2.5倍(bei),擊(ji)穿電(dian)(dian)(dian)壓(ya)(ya)(ya)的(de)(de)(de)空氣(qi)的(de)(de)(de)2.5倍(bei)。在0.25MPa下(xia)與油的(de)(de)(de)擊(ji)穿電(dian)(dian)(dian)壓(ya)(ya)(ya)相(xiang)等(deng)(deng),在0.45MPa壓(ya)(ya)(ya)力(li)下(xia)是(shi)(shi)油的(de)(de)(de)擊(ji)穿電(dian)(dian)(dian)壓(ya)(ya)(ya)的(de)(de)(de)2倍(bei),是(shi)(shi)一(yi)種(zhong)優于油的(de)(de)(de)新一(yi)代(dai)超(chao)高(gao)(gao)壓(ya)(ya)(ya)絕(jue)緣介質材料。該產(chan)品技術要求完全符合《ZBK-41006-89》標準(zhun)(zhun),它是(shi)(shi)油浸式輕(qing)型試驗(yan)(yan)變(bian)壓(ya)(ya)(ya)器的(de)(de)(de)換代(dai)產(chan)品。該產(chan)品具有體積小、重量(liang)輕(qing)、不受(shou)氣(qi)候變(bian)化影響、電(dian)(dian)(dian)暈小、現場搬運無需靜止可使(shi)用(yong),使(shi)用(yong)壽命長(chang)、免(mian)維修等(deng)(deng)特點。適(shi)用(yong)于電(dian)(dian)(dian)力(li)系統(tong)、工礦企業、科研部門等(deng)(deng)對各種(zhong)高(gao)(gao)壓(ya)(ya)(ya)電(dian)(dian)(dian)氣(qi)設(she)備、電(dian)(dian)(dian)氣(qi)元件、絕(jue)緣材料進行工頻或直(zhi)流高(gao)(gao)壓(ya)(ya)(ya)下(xia)的(de)(de)(de)絕(jue)緣強(qiang)度(du)試驗(yan)(yan)。
二、產(chan)品結構(gou)
YDQ系列高(gao)壓(ya)試驗(yan)變壓(ya)器(qi)采用單框芯(xin)式鐵(tie)芯(xin)結(jie)構,初級繞(rao)組(zu)繞(rao)在(zai)鐵(tie)芯(xin)上,高(gao)壓(ya)繞(rao)組(zu)在(zai)外,這種同軸布置減少了(le)漏(lou)磁(ci)通,因而增(zeng)大了(le)繞(rao)組(zu)間的耦合。產(chan)品(pin)的外殼為圓柱(zhu)灌式容器(qi)結(jie)構,能耐受(shou)0.8MPa以(yi)上壓(ya)力(li)。其結(jie)構見(jian)圖1:
三、工(gong)作(zuo)原理(li)
YDQ系列高(gao)壓(ya)試(shi)驗(yan)(yan)變(bian)(bian)壓(ya)器(qi)(qi)為單(dan)相變(bian)(bian)壓(ya)器(qi)(qi),聯結組標號(hao)Ⅰ.Ⅰ. 用工頻(pin)220V(10kVA以上為380V)電源接入 (為本公司生產的試(shi)驗(yan)(yan)變(bian)(bian)壓(ya)器(qi)(qi)配套專用設備,詳(xiang)細資料(liao)請(qing)見其具體使用說明書)系列操作箱(臺),經(jing)操作箱內(nei)自偶調壓(ya)器(qi)(qi)(50kVA以上調壓(ya)器(qi)(qi)外(wai)附(fu))調節至0~200V(或0~400V)電壓(ya)輸(shu)出至YDQ試(shi)驗(yan)(yan)變(bian)(bian)壓(ya)器(qi)(qi)的初級繞(rao)(rao)組,根(gen)據(ju)電磁感(gan)應原理,在試(shi)驗(yan)(yan)變(bian)(bian)壓(ya)器(qi)(qi)高(gao)壓(ya)繞(rao)(rao)組可獲得(de)試(shi)驗(yan)(yan)所需(xu)的高(gao)電壓(ya)。
單臺YDQ系列交(jiao)直(zhi)流(liu)(liu)(liu)高(gao)壓(ya)(ya)(ya)試(shi)驗變壓(ya)(ya)(ya)器的(de)工(gong)作(zuo)(zuo)原理(li)圖(tu)見圖(tu)3,圖(tu)中(zhong)高(gao)壓(ya)(ya)(ya)套(tao)管(guan)中(zhong)裝有高(gao)壓(ya)(ya)(ya)硅(gui)堆,串(chuan)接(jie)(jie)在高(gao)壓(ya)(ya)(ya)回路(lu)中(zhong)作(zuo)(zuo)半波整流(liu)(liu)(liu),以獲得直(zhi)流(liu)(liu)(liu)高(gao)電壓(ya)(ya)(ya)。當用(yong)一短(duan)路(lu)桿(gan)將高(gao)壓(ya)(ya)(ya)硅(gui)堆短(duan)接(jie)(jie)時(shi),可獲得工(gong)頻高(gao)電壓(ya)(ya)(ya),作(zuo)(zuo)為交(jiao)流(liu)(liu)(liu)輸(shu)(shu)出(chu)狀態;取消(xiao)短(duan)路(lu)桿(gan)時(shi),作(zuo)(zuo)為直(zhi)流(liu)(liu)(liu)輸(shu)(shu)出(chu)狀態。
圖中:D—短路桿 VD—高壓硅堆
試(shi)驗變(bian)壓器(qi)高壓套管中的高壓硅堆未畫出,其原理與上圖相同(tong)。
三臺(tai)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)串(chuan)級(ji)獲(huo)得更(geng)高電壓(ya)(ya)(ya)(ya)(ya)的(de)(de)接(jie)線(xian)原(yuan)理(li)見圖4。串(chuan)級(ji)高壓(ya)(ya)(ya)(ya)(ya)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)有(you)很大的(de)(de)優越(yue)性(xing),因為(wei)(wei)整(zheng)個試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)裝(zhuang)(zhuang)置由幾臺(tai)單(dan)(dan)臺(tai)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)組(zu)成(cheng),單(dan)(dan)臺(tai)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)容量(liang)小(xiao)(xiao)、電壓(ya)(ya)(ya)(ya)(ya)低、重量(liang)輕,便(bian)于(yu)運輸(shu)(shu)和(he)(he)安裝(zhuang)(zhuang)。它既(ji)然可串(chuan)接(jie)成(cheng)高出(chu)(chu)幾倍的(de)(de)單(dan)(dan)臺(tai)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)輸(shu)(shu)出(chu)(chu)電壓(ya)(ya)(ya)(ya)(ya)組(zu)合使(shi)用,又可分開成(cheng)幾套單(dan)(dan)臺(tai)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)單(dan)(dan)獨使(shi)用。整(zheng)套裝(zhuang)(zhuang)置投資(zi)小(xiao)(xiao),經(jing)濟實惠(hui)。圖5中(zhong),在(zai)第**和(he)(he)**級(ji)的(de)(de)每個單(dan)(dan)元試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)中(zhong)都有(you)一個勵磁(ci)繞組(zu)A1、C1和(he)(he)A2、C2。在(zai)三臺(tai)串(chuan)級(ji)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)基本(ben)原(yuan)理(li)中(zhong),低壓(ya)(ya)(ya)(ya)(ya)電源(yuan)加在(zai)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅰ的(de)(de)初(chu)(chu)級(ji)繞組(zu)a1x1上(shang),單(dan)(dan)臺(tai)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅰ、Ⅱ、Ⅲ的(de)(de)輸(shu)(shu)出(chu)(chu)電壓(ya)(ya)(ya)(ya)(ya)都是V。勵磁(ci)繞組(zu)A1、C1給(gei)**級(ji)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅱ的(de)(de)初(chu)(chu)級(ji)繞組(zu)供電;**級(ji)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅱ的(de)(de)勵磁(ci)繞組(zu)A2、C2給(gei)第三級(ji)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅲ的(de)(de)初(chu)(chu)級(ji)繞組(zu)供電。**級(ji)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅱ和(he)(he)第三級(ji)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅲ的(de)(de)箱(xiang)體(ti)分別處在(zai)對地為(wei)(wei)1V和(he)(he)2V的(de)(de)高電位上(shang),所(suo)以箱(xiang)體(ti)對地是絕緣的(de)(de),試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)Ⅰ的(de)(de)箱(xiang)體(ti)是接(jie)地的(de)(de)。這樣(yang)第**、**級(ji)、第三級(ji)試(shi)(shi)(shi)(shi)(shi)(shi)驗(yan)(yan)變(bian)(bian)(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)(qi)(qi)(qi)對地的(de)(de)額定(ding)輸(shu)(shu)出(chu)(chu)電壓(ya)(ya)(ya)(ya)(ya)分別為(wei)(wei)1V、2V、3V;其額定(ding)容量(liang)分別為(wei)(wei)3P、2P、1P。
YDQ系(xi)列高壓(ya)試驗變壓(ya)器做被試品的(de)工頻耐壓(ya)試驗使用接線(xian)原理圖見圖5。
圖中:R1—限流電阻 FRC—阻容分壓(ya)器 RF—球間(jian)隙保護電阻 G—球間(jian)隙 CX—被試(shi)品
注:高(gao)壓尾(wei)必(bi)須可(ke)靠接地
工頻耐壓試驗(yan)中限流電(dian)阻R1應(ying)根(gen)據(ju)試驗(yan)變壓器的(de)額(e)定(ding)容量(liang)來選擇。如高壓側額(e)定(ding)輸(shu)出(chu)電(dian)流在100~300mA時(shi),可(ke)取(qu)(qu)0.5~1Ω/V(試驗(yan)電(dian)壓);高壓側額(e)定(ding)輸(shu)出(chu)電(dian)流為(wei)1A以上時(shi),可(ke)取(qu)(qu)1Ω/V(試驗(yan)電(dian)壓)。常用水電(dian)阻作(zuo)為(wei)限流電(dian)阻,管子(zi)長(chang)度(du)可(ke)按150kV/m考(kao)慮,管子(zi)粗(cu)細應(ying)具有足夠(gou)的(de)熱容量(liang)(水阻液配制方法:用蒸餾水加入適量(liang)硫酸銅配制成(cheng)各種不同(tong)的(de)阻值)。
球(qiu)(qiu)間(jian)隙(xi)(xi)及保(bao)(bao)護電(dian)(dian)阻:當電(dian)(dian)壓超過球(qiu)(qiu)間(jian)隙(xi)(xi)整定值時(一般取(qu)(qu)試(shi)驗(yan)電(dian)(dian)壓的110%~120%),球(qiu)(qiu)間(jian)隙(xi)(xi)放電(dian)(dian),對(dui)被試(shi)品起(qi)到保(bao)(bao)護作用。球(qiu)(qiu)間(jian)隙(xi)(xi)保(bao)(bao)護電(dian)(dian)阻可按1Ω/V(試(shi)驗(yan)電(dian)(dian)壓)選(xuan)取(qu)(qu)。
在(zai)工頻耐壓(ya)(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)(yan)中,低電壓(ya)(ya)(ya)(ya)(ya)側測(ce)量電壓(ya)(ya)(ya)(ya)(ya)(儀表電壓(ya)(ya)(ya)(ya)(ya))不是(shi)非常準確(que)的(de)(de)(de),其原因(yin)是(shi)由于(yu)試(shi)(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)存(cun)在(zai)著(zhu)(zhu)漏(lou)抗,在(zai)這個漏(lou)抗上(shang)(shang)必然(ran)存(cun)在(zai)著(zhu)(zhu)壓(ya)(ya)(ya)(ya)(ya)降或(huo)容(rong)(rong)升,使試(shi)(shi)品上(shang)(shang)的(de)(de)(de)電壓(ya)(ya)(ya)(ya)(ya)低于(yu)或(huo)高于(yu)低壓(ya)(ya)(ya)(ya)(ya)側測(ce)量電壓(ya)(ya)(ya)(ya)(ya)表上(shang)(shang)反映(ying)出來的(de)(de)(de)電壓(ya)(ya)(ya)(ya)(ya)。工頻耐壓(ya)(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)(yan)時(shi),被試(shi)(shi)品上(shang)(shang)的(de)(de)(de)電壓(ya)(ya)(ya)(ya)(ya)高于(yu)試(shi)(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)的(de)(de)(de)輸出電壓(ya)(ya)(ya)(ya)(ya),也就是(shi)所(suo)謂容(rong)(rong)升現象。感應(ying)耐壓(ya)(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)(yan)時(shi),試(shi)(shi)驗(yan)(yan)變(bian)壓(ya)(ya)(ya)(ya)(ya)器(qi)的(de)(de)(de)漏(lou)抗必然(ran)存(cun)在(zai)著(zhu)(zhu)壓(ya)(ya)(ya)(ya)(ya)降。為了準確(que)測(ce)量被試(shi)(shi)品上(shang)(shang)所(suo)施加的(de)(de)(de)電壓(ya)(ya)(ya)(ya)(ya),因(yin)此(ci)常在(zai)高壓(ya)(ya)(ya)(ya)(ya)側接入FRC阻容(rong)(rong)分壓(ya)(ya)(ya)(ya)(ya)器(qi)來測(ce)量電壓(ya)(ya)(ya)(ya)(ya)(見(jian)圖(tu)5)。
工頻耐(nai)壓試驗操作注(zhu)意(yi)事(shi)項
1)試驗(yan)人(ren)員應(ying)做好(hao)分工,明確相互間(jian)聯系方法。并有專門人(ren)監護現場(chang)**及觀察試品狀態。
2)被試品(pin)應先清掃干凈,并**干燥,以免損壞被試品(pin)和試驗帶來的(de)誤差。
3)對(dui)于大型試驗,一(yi)般都應先進(jin)行空(kong)升(sheng)(sheng)試驗。即不接試品(pin)時升(sheng)(sheng)壓至(zhi)試驗電壓,校對(dui)各種表計(ji),調整球間隙。
4)升壓速度不能(neng)太快,并必須(xu)防止突(tu)然(ran)加壓。例如調(diao)壓器不在零(ling)位時突(tu)然(ran)合(he)閘(zha)。也不能(neng)突(tu)然(ran)切(qie)斷電(dian)源,一般(ban)應在調(diao)壓器降至零(ling)位時拉閘(zha)。
5)當電(dian)(dian)壓(ya)升至試(shi)驗電(dian)(dian)壓(ya)時(shi),開始計(ji)時(shi),到(dao)1min后(hou),迅速降(jiang)壓(ya)到(dao)1/3試(shi)驗電(dian)(dian)壓(ya)以(yi)下時(shi),才(cai)能拉開電(dian)(dian)源。
6)在升(sheng)壓或(huo)耐壓試驗過程中,如發(fa)現下列不正(zheng)常情況時,應立(li)即降壓,切斷電源。停止試驗并查明原(yuan)因:①電壓表指針擺動很(hen)大;②發(fa)現絕緣燒(shao)焦或(huo)冒煙;③被試品內有不正(zheng)常的聲音。
7)耐壓試驗前后應測量絕緣電阻,檢查絕緣情況(kuang)。
試(shi)驗(yan)(yan)變壓(ya)器在做被(bei)試(shi)品的直(zhi)流耐(nai)壓(ya)或泄露試(shi)驗(yan)(yan)時(shi)接線原理圖如圖6。
注:此試驗應先抽出短(duan)路桿(gan)“D”,圖6中所示(shi)。
圖(tu)中:VD—高壓硅堆 R1—限流電(dian)阻 C1—高壓濾波(bo)電(dian)容 FRC—阻容分壓器 CX—被試品 μA—帶保護微安表
泄露(lu)試驗(yan)中限流(liu)(liu)電(dian)(dian)(dian)阻(zu)R1選(xuan)擇在(zai)額定輸(shu)出(chu)(chu)電(dian)(dian)(dian)壓時(shi),輸(shu)出(chu)(chu)端(duan)短路電(dian)(dian)(dian)流(liu)(liu)不超過高壓硅堆的(de)(de)*大整流(liu)(liu)。如電(dian)(dian)(dian)壓硅堆的(de)(de)*大整流(liu)(liu)電(dian)(dian)(dian)流(liu)(liu)為100mA時(shi)用(yong)于60kV的(de)(de)試驗(yan)裝置中,限流(liu)(liu)電(dian)(dian)(dian)阻(zu)按(an)R1=60/0.1=600kΩ選(xuan)擇。限流(liu)(liu)電(dian)(dian)(dian)阻(zu)還應具(ju)有足夠的(de)(de)容(rong)量和沿面放電(dian)(dian)(dian)距(ju)離。
高壓(ya)濾波電容C1一般選擇在(zai)0.01~0.1μF,當被(bei)試品的(de)電容量(liang)很(hen)大時(shi),C1可省略不用。
泄露試驗的操(cao)作及注意事項(xiang)
1)試驗前應(ying)先(xian)檢查被(bei)試品是否停電(dian),接地放電(dian),一(yi)切對外(wai)連線是否擦干凈(jing)。要嚴防(fang)將試驗電(dian)壓加到有人工作(zuo)的部位上去。
2)接好試(shi)驗裝置(zhi)的(de)接線(xian)后(hou),應復(fu)查無誤后(hou)才可加壓。應特別注(zhu)意(yi)檢(jian)查高壓設備及(ji)引線(xian)與地(di)(di)、與操作人(ren)員的(de)**距離,被(bei)試(shi)品的(de)外殼是否可靠接地(di)(di),要(yao)按**規程中(zhong)所規定(ding)的(de)內容(rong)進行(xing)試(shi)驗。
3)對于大電容(rong)量設備應緩慢升(sheng)壓,防止被試品(pin)的(de)充電電流燒壞微(wei)安表(biao)。必要(yao)時應分級加壓,分別(bie)讀取各(ge)級電壓下微(wei)安表(biao)的(de)穩定讀數。
4)試驗過(guo)程中(zhong),應密切(qie)監(jian)視被試品、試驗裝(zhuang)置、微安表,一旦發生擊(ji)穿、閃(shan)爍等異常現(xian)象(xiang)應立即降壓,切(qie)斷(duan)電源,并查明原因,詳細(xi)記(ji)錄。
5)試驗完畢,降(jiang)壓,切斷電源(yuan)后應將被試品及試驗裝(zhuang)置本身充(chong)分放(fang)電。
四、注意(yi)事項
1、按(an)照您(nin)所進行的(de)試驗接好(hao)工作線路。試驗變壓器(qi)的(de)外殼(ke)以(yi)及操(cao)作系統(tong)的(de)外殼(ke)必須可(ke)靠接地。試驗變壓器(qi)高(gao)壓繞組的(de)X端(高(gao)壓尾)以(yi)及測量繞組的(de)F端必須可(ke)靠接地。
2、做串級(ji)試(shi)驗(yan)時,**級(ji)、第(di)三級(ji)試(shi)驗(yan)變壓(ya)器的(de)低(di)壓(ya)繞組的(de)X端(duan),測量繞組的(de)F端(duan)以及高壓(ya)繞組的(de)X端(duan)(高壓(ya)尾(wei))均接本級(ji)試(shi)驗(yan)變壓(ya)器的(de)外(wai)殼(ke)(ke)。**級(ji)、第(di)三級(ji)試(shi)驗(yan)變壓(ya)器的(de)外(wai)殼(ke)(ke)必須通過絕緣支架接地(di)。
3、接通電源前,操作系統的調(diao)壓(ya)器必須調(diao)到零位后方可接通電源,合閘,開始升壓(ya)。
4、從(cong)零開(kai)始均勻旋轉調壓器手輪升(sheng)壓。升(sheng)壓方(fang)法(fa)有(you):快速升(sheng)壓法(fa),即(ji)20s逐級升(sheng)壓法(fa);慢速升(sheng)壓法(fa),即(ji)60s逐級升(sheng)壓法(fa);極(ji)慢速升(sheng)壓法(fa)供(gong)選用。電(dian)壓從(cong)零開(kai)始按一定的升(sheng)壓方(fang)式和速度上升(sheng)到您所需的額定試(shi)驗電(dian)壓的75%后,在以(yi)每秒2%額定試(shi)驗電(dian)壓的速度升(sheng)到您所需的額定電(dian)壓,并密切注意測(ce)量儀(yi)表的指示以(yi)及(ji)被(bei)試(shi)品(pin)的情(qing)況(kuang)(kuang)。升(sheng)壓過程中或(huo)試(shi)驗過程中如發現(xian)測(ce)量儀(yi)表的指示及(ji)被(bei)試(shi)品(pin)情(qing)況(kuang)(kuang)異常,應立即(ji)降(jiang)壓,切斷電(dian)源,查明情(qing)況(kuang)(kuang)。
5、試驗(yan)完畢后(hou),應在(zai)數秒(miao)內(nei)勻速的將(jiang)調壓(ya)器返回至零位,然后(hou)切斷電源。
6、本產品不得(de)超過額定(ding)參數使(shi)用。除試驗必須外,決不允許(xu)全(quan)電壓通電或斷電。
7、 再升壓或耐壓試(shi)驗(yan)過程中,如發現以下不正常情況時,應立(li)即降壓,切斷電源,停止試(shi)驗(yan)并查明原因。
⑴電壓表指(zhi)針擺動(或(huo)數(shu)字跳動)很大
⑵電流表直線上(shang)升
被(bei)試品內有不正(zheng)常的聲音(yin)
8、圖1中第9項系壓力閥及壓力表,為長(chang)期(qi)關閉(bi)狀態。每6個(ge)月(yue)開閥一(yi)次,以(yi)檢查SF6壓力,應不小于0.2MPa(檢查壓力后立(li)即關閉(bi)閥門),低(di)于0.2MPa時應加SF6氣體,以(yi)增加氣絕緣(yuan)。
9、耐壓(ya)實(shi)驗前后應測量被試設備(bei)的絕緣電(dian)阻,檢(jian)查絕緣情況。
10、當試驗變(bian)壓器長期不使用時,應放置于(yu)通風、干燥、無陽光直射的地方。
11、該產品不允許在高(gao)于(yu)45℃的溫度(du)下長期(qi)存放、使用、放氣。
12、運輸搬運途(tu)中不得重(zhong)力沖擊。
13、產品緊(jin)固(gu)件及壓力閥、壓力表不得擅自松動。
14、使用本產(chan)品做高(gao)(gao)壓(ya)(ya)試驗(yan)(yan)時,出熟悉本說明書外,還必須嚴格執行國(guo)家(jia)有關標準和操作規(gui)程。可(ke)參(can)照(zhao)GB311-83《高(gao)(gao)壓(ya)(ya)輸變設(she)備的絕緣配(pei)合,高(gao)(gao)壓(ya)(ya)試驗(yan)(yan)技(ji)術》;《電氣設(she)備預(yu)防(fang)性試驗(yan)(yan)規(gui)程》等。
五(wu)、試驗變壓器的容量選擇
標稱試(shi)驗變(bian)壓器容量(liang)Pn的確定公式(shi):Pn=kVn 2ωCt×10-9
式中:
Pn——標(biao)稱試(shi)驗(yan)變壓器(qi)容量(kVA)
Vn——試(shi)驗(yan)變壓器(qi)的(de)額(e)定(ding)輸出高(gao)壓的(de)有效值(kV)
k ——**系數。k≥1,標(biao)稱電壓(ya)Vn≥1MV時,k=2;標(biao)稱電壓(ya)較(jiao)低時,k值可取高一些。
Ct——被試品的電容量(pF)
ω——角頻率,ω=2πf,f——試驗電源的頻率
被試設備的(de)電(dian)容量Ct可由交流電(dian)橋測出。Ct的(de)變(bian)化很大(da),
可由(you)設備的類型而定。
典型數據如下:
簡(jian)單的棒式(shi)或懸式(shi)絕緣子(zi) 幾(ji)十(shi)微法
簡(jian)單的分級套管 100~1000pF
電壓(ya)互(hu)感器 200 ~ 500pF
電力(li)變壓(ya)器 < 1000kVA~1000pF
> 1000kVA 1000~10000pF
高壓電力電纜和油浸紙絕緣 250~300pF/m
氣體絕(jue)緣 ~60pF/m
封閉變電站,SF6氣體絕緣 100~10000Pf;
對于不(bu)同(tong)的試驗電壓(ya)Vn,選(xuan)擇不(bu)同(tong)的(適當的)**系數(shu)k。
以下列(lie)出不同的(de)Vn所選用的(de)k值供參考(kao)。
Vn =50~100kV k = 4
Vn =150~300kV k = 3
Vn > 300kV k = 2
一、概述
工頻耐(nai)壓試驗是(shi)鑒定(ding)電力(li)設(she)備(bei)絕(jue)緣(yuan)強度的*嚴格、*有效和*直接的方法。它能檢查出那些(xie)危(wei)險性較大(da)的集中缺陷,對(dui)判(pan)斷電力(li)設(she)備(bei)能否(fou)繼續參(can)加運行具有決定(ding)性作用,是(shi)保證設(she)備(bei)絕(jue)緣(yuan)水平(ping)、避免發生(sheng)絕(jue)緣(yuan)事故的重(zhong)要手段。
本裝置是根(gen)據國家*新電(dian)力行業標準而設計的(de)(de)、性能先進的(de)(de)耐(nai)壓(ya)試驗設備,用于對各(ge)種電(dian)器產品(pin)、電(dian)氣元件、絕緣材料等進行規(gui)定電(dian)壓(ya)下(xia)的(de)(de)絕緣強度試驗,以(yi)考核產品(pin)的(de)(de)絕緣水平(ping),發現(xian)被試品(pin)的(de)(de)絕緣缺陷(xian),衡量過電(dian)壓(ya)的(de)(de)能力。
二(er)、產(chan)品特點
監視功(gong)能:高壓電壓 低壓電流 零位指(zhi)示(shi)(shi)(shi) 電源指(zhi)示(shi)(shi)(shi) 工作(zuo)指(zhi)示(shi)(shi)(shi) 計(ji)時(shi)指(zhi)示(shi)(shi)(shi)
保(bao)護(hu)功能(neng):過流保(bao)護(hu)、零位啟動保(bao)護(hu)、聲光語(yu)言報警提(ti)醒
采用新(xin)型時間繼電器,計時范(fan)圍(wei)更廣(1S~99H)
采(cai)用新型電(dian)流(liu)繼電(dian)器,更**、更可靠,確(que)保人身及(ji)設(she)備**。
試驗變壓(ya)器高(gao)壓(ya)線圈為圓(yuan)筒多層塔式,由上等聚(ju)酯漆包線及高(gao)耐壓(ya)值絕(jue)緣材料繞制而成(cheng)。
試驗變壓器(5kVA以(yi)上)裝有可移動(dong)的鐵輪。具有重(zhong)量輕(qing)、體(ti)積小(xiao)、移動(dong)方(fang)便、性能優越等特點。
三、設備組(zu)成
1、選型配置
標準配(pei)置
|
□ 分(fen)體(ti)式
|
操作部分:
□箱式(不大于5kVA) / □臺式
容量(liang): kVA(小于200kVA)
輸入(ru):□AC220V / □AC380V
|
試驗變壓器(qi):
□交流 / □交直流
□油變 / □干變 / □氣變
容量: kVA(小于200kVA)
輸出:AC kV(小于300kVA)
|
□ 一體(ti)式(shi)
|
□箱式(不(bu)大于(yu)20kV) / □臺式(不(bu)大于(yu)30kV)
容量: kVA(小于300kVA)
輸入:□AC220V / □AC380V 輸出:AC kV(不(bu)大(da)于30kV)
|
客(ke)戶選配
|
□標(biao)準(zhun)高壓分壓器
|
□保護球隙
|
□直流微安表
|
□放**
|
□保護水阻
|
□高壓(ya)濾波電容(rong)
|
其它:
|
2、對應(ying)實(shi)物
四、技術指標
1、使用條件:
(1)工作(zuo)場所應無嚴重影響(xiang)絕(jue)緣的(de)氣體、蒸汽(qi)、化學性塵埃及(ji)其它爆炸性和(he)腐蝕性介質(zhi)。
(2)環境溫(wen)度 -20~+50℃
(3)環境濕度 ≤85% RH(無凝結水(shui))
2、控制箱(臺)參數:(常規參數見下(xia)表)
規格(ge)
|
容(rong)量
|
輸 入 電 源
|
輸(shu) 出 電 壓
|
重量(kg)
|
相數(shu)
|
(V)
|
(A)
|
(V)
|
(A)
|
2/220
|
2
|
1
|
220
|
10
|
0-250
|
8
|
14
|
3/220
|
3
|
1
|
220
|
15
|
0-250
|
12
|
16
|
5/220
|
5
|
1
|
220
|
25
|
0-250
|
20
|
18
|
10/220
|
10
|
1
|
220
|
50
|
0-250
|
40
|
80
|
15/380
|
15
|
2
|
380
|
37.5
|
0-430
|
34.8
|
90
|
20/380
|
20
|
2
|
380
|
50
|
0-430
|
46.5
|
100
|
25/380
|
25
|
2
|
380
|
62.5
|
0-430
|
58.1
|
120
|
30/380
|
30
|
2
|
380
|
75
|
0-430
|
69.7
|
140
|
50/380
|
50
|
2
|
380
|
125
|
0-430
|
116.2
|
160
|
100/380
|
100
|
2
|
380
|
250
|
0-430
|
232.5
|
250
|
說(shuo)明:如有(you)特(te)殊參數(shu)要求(qiu),可按用戶(hu)的(de)技術(shu)參數(shu)進行設計制作。
3、試驗變壓器參數:(常規(gui)參數見下表(biao))
規(gui)格
|
容量(liang)
kVA
|
低壓側(ce)
|
高壓側
|
高(gao)壓側(交直流(liu)變(bian)壓器)
|
測量變比
|
60分鐘溫升(sheng)℃
|
阻抗電(dian)壓%
|
空載(zai)電(dian)流
%
|
質量
kg
|
電壓
V
|
電流
A
|
交(jiao)流輸出
|
直(zhi)流輸出
|
電壓kV
|
電流
|
電(dian)壓kV
|
電流
|
1.5/50
|
1.5
|
200
|
7.5
|
50
|
30
|
70
|
21.4
|
500
|
50
|
10
|
<4
|
19.5
|
3/50
|
3
|
200
|
15
|
50
|
60
|
70
|
42.9
|
500
|
50
|
10
|
<4
|
27
|
5/50
|
5
|
200
|
25
|
50
|
100
|
70
|
71.4
|
500
|
50
|
10
|
<4
|
52
|
10/50
|
10
|
200
|
50
|
50
|
200
|
70
|
142.9
|
500
|
50
|
10
|
<4
|
80
|
15/50
|
15
|
400
|
37.5
|
50
|
300
|
70
|
214.3
|
500
|
50
|
8
|
<4
|
120
|
20/50
|
20
|
400
|
50
|
50
|
400
|
70
|
285.7
|
500
|
50
|
8
|
<4
|
140
|
30/50
|
30
|
400
|
75
|
50
|
600
|
70
|
428.6
|
500
|
50
|
8
|
<4
|
155
|
50/50
|
50
|
400
|
125
|
50
|
1000
|
70
|
714.3
|
500
|
50
|
8
|
<4
|
184
|
10/100
|
10
|
200
|
50
|
100
|
100
|
140
|
71.4
|
1000
|
50
|
10
|
<4
|
135
|
15/100
|
15
|
400
|
37.5
|
100
|
150
|
140
|
107.1
|
1000
|
50
|
8
|
<4
|
150
|
20/100
|
20
|
400
|
50
|
100
|
200
|
140
|
142.9
|
1000
|
50
|
8
|
<4
|
215
|
30/100
|
30
|
400
|
75
|
100
|
300
|
140
|
214.3
|
1000
|
50
|
8
|
<4
|
250
|
50/100
|
50
|
400
|
125
|
100
|
500
|
140
|
357.1
|
1000
|
50
|
8
|
<4
|
290
|
10/150
|
10
|
200
|
50
|
100
|
66.7
|
140
|
47.6
|
1500
|
50
|
10
|
<4
|
180
|
15/150
|
15
|
400
|
37.5
|
150
|
100
|
210
|
71.4
|
1500
|
50
|
8
|
<4
|
200
|
20/150
|
30
|
400
|
50
|
150
|
133.3
|
210
|
95.2
|
1500
|
50
|
8
|
<4
|
220
|
30/150
|
30
|
400
|
75
|
150
|
200
|
210
|
142.9
|
1500
|
50
|
8
|
<4
|
280
|
50/150
|
50
|
400
|
125
|
150
|
333.3
|
210
|
238.1
|
1500
|
50
|
8
|
<4
|
340
|
說(shuo)明:如(ru)有(you)特(te)殊參數要求,可按用戶(hu)的(de)技(ji)術參數進行(xing)設計制作。
上表的重量以油浸式試(shi)驗變(bian)(bian)壓(ya)(ya)器為例,干式試(shi)驗變(bian)(bian)壓(ya)(ya)器和充氣式試(shi)驗變(bian)(bian)壓(ya)(ya)器稍有不同。
五(wu)、接線(xian)及工(gong)作原理
1、調壓部分接線及原理
調(diao)壓(ya)部(bu)分由(you)控(kong)制(zhi)部(bu)分和試(shi)驗變壓(ya)器(qi)組(zu)(zu)成(cheng)。控(kong)制(zhi)部(bu)分是(shi)由(you)接(jie)觸(chu)式調(diao)壓(ya)器(qi)及其控(kong)制(zhi)、保護(hu)、測量、信號(hao)電(dian)路組(zu)(zu)成(cheng)。試(shi)驗變壓(ya)器(qi)由(you)低(di)壓(ya)繞組(zu)(zu)、高壓(ya)繞組(zu)(zu)、儀(yi)表繞組(zu)(zu)三部(bu)分組(zu)(zu)成(cheng)。
試驗變壓器(qi)為(wei)交直流兩用時,試驗變壓器(qi)配置了高(gao)壓硅(gui)(gui)堆(dui)(dui)(油(you)(you)變、氣(qi)變為(wei)內置,干變為(wei)外置),高(gao)壓可(ke)輸(shu)出(chu)交流和直流。輸(shu)出(chu)交流時,要求接入(ru)短(duan)路桿(gan)(油(you)(you)變、氣(qi)變)或去掉外置硅(gui)(gui)堆(dui)(dui)(干變);輸(shu)出(chu)直流時,要求擰出(chu)短(duan)路桿(gan)(油(you)(you)變、氣(qi)變)或加上外置硅(gui)(gui)堆(dui)(dui)(干變)
通過接入工(gong)頻電源,調(diao)節調(diao)壓器,以獲得所需要的試驗高壓電壓值(zhi)。其工(gong)作原理見圖1:
2、試(shi)驗(yan)部分接(jie)線及(ji)原理
做耐(nai)(nai)壓試(shi)驗時,控制部(bu)分、變壓器的接地(di)端及高壓尾(wei)必須可靠接地(di)。有條件(jian)的情況下,做工頻耐(nai)(nai)壓試(shi)驗請加上限流電阻(zu)、標準(zhun)高壓分壓器、球隙(xi)保(bao)護(hu)電阻(zu)及保(bao)護(hu)球隙(xi),如圖3。
做(zuo)直流(liu)耐壓(ya)試驗請(qing)另(ling)外加上微安(an)表,微安(an)表必(bi)須接在(zai)硅堆(dui)(dui)(dui)和被試器之(zhi)間,油變或氣(qi)變一(yi)般(ban)擰在(zai)高壓(ya)頭上面(要求擰出短路(lu)桿),干變擰在(zai)外置硅堆(dui)(dui)(dui)上面;為了更準確顯示高壓(ya)直流(liu)泄(xie)漏電流(liu),請(qing)將分壓(ya)器的高壓(ya)線接在(zai)微安(an)表和硅堆(dui)(dui)(dui)之(zhi)間,(油變、氣(qi)變)如圖4,(干變)如圖5。
耐壓試(shi)驗(yan)(yan)(yan)中(zhong)限流電(dian)(dian)(dian)(dian)(dian)阻(zu)R1應(ying)根據試(shi)驗(yan)(yan)(yan)變壓器的(de)額(e)定(ding)容量(liang)(liang)(liang)來選擇。如高(gao)壓側額(e)定(ding)輸(shu)出(chu)電(dian)(dian)(dian)(dian)(dian)流在(zai)100~300mA時(shi),可取(qu)0.5~1Ω/V(試(shi)驗(yan)(yan)(yan)電(dian)(dian)(dian)(dian)(dian)壓);高(gao)壓側額(e)定(ding)輸(shu)出(chu)電(dian)(dian)(dian)(dian)(dian)流為1A以上時(shi),可取(qu)1Ω/V(試(shi)驗(yan)(yan)(yan)電(dian)(dian)(dian)(dian)(dian)壓)。常用水電(dian)(dian)(dian)(dian)(dian)阻(zu)作(zuo)為限流電(dian)(dian)(dian)(dian)(dian)阻(zu),管(guan)子長(chang)度可按150kV/m考慮,管(guan)子粗細應(ying)具有(you)足(zu)夠的(de)熱容量(liang)(liang)(liang)(水阻(zu)液配制(zhi)方法:用蒸(zheng)餾水加(jia)入適量(liang)(liang)(liang)硫酸(suan)銅配制(zhi)成各種不同的(de)阻(zu)值(zhi))。
球間(jian)隙(xi)及(ji)保(bao)(bao)護(hu)(hu)電阻(zu):當電壓(ya)超過球間(jian)隙(xi)整定值(zhi)時(一般取試(shi)驗電壓(ya)的110%~120%),球間(jian)隙(xi)放電,對被試(shi)品起(qi)到保(bao)(bao)護(hu)(hu)作用。球間(jian)隙(xi)保(bao)(bao)護(hu)(hu)電阻(zu)可按(an)1Ω/V(試(shi)驗電壓(ya))選取。
在(zai)(zai)工頻耐壓(ya)(ya)(ya)(ya)(ya)試(shi)驗(yan)(yan)中(zhong),低(di)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)側(ce)測(ce)(ce)(ce)量(liang)(liang)(liang)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)(儀(yi)表電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya))不是(shi)非常(chang)準確的(de),其(qi)原因(yin)是(shi)由于試(shi)驗(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)器存在(zai)(zai)著漏(lou)抗(kang),在(zai)(zai)這(zhe)個漏(lou)抗(kang)上(shang)(shang)必(bi)然存在(zai)(zai)著壓(ya)(ya)(ya)(ya)(ya)降或(huo)容升,使(shi)試(shi)品(pin)上(shang)(shang)的(de)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)低(di)于或(huo)高(gao)于低(di)壓(ya)(ya)(ya)(ya)(ya)側(ce)測(ce)(ce)(ce)量(liang)(liang)(liang)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)表上(shang)(shang)反映出來的(de)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)。工頻耐壓(ya)(ya)(ya)(ya)(ya)試(shi)驗(yan)(yan)時,被試(shi)品(pin)上(shang)(shang)的(de)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)高(gao)于試(shi)驗(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)器的(de)輸出電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya),也就(jiu)是(shi)所(suo)謂容升現(xian)象。感應(ying)耐壓(ya)(ya)(ya)(ya)(ya)試(shi)驗(yan)(yan)時,試(shi)驗(yan)(yan)變壓(ya)(ya)(ya)(ya)(ya)器的(de)漏(lou)抗(kang)必(bi)然存在(zai)(zai)著壓(ya)(ya)(ya)(ya)(ya)降。為了準確測(ce)(ce)(ce)量(liang)(liang)(liang)被試(shi)品(pin)上(shang)(shang)所(suo)施加的(de)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya),因(yin)此常(chang)在(zai)(zai)高(gao)壓(ya)(ya)(ya)(ya)(ya)側(ce)接入標準高(gao)壓(ya)(ya)(ya)(ya)(ya)分壓(ya)(ya)(ya)(ya)(ya)器來測(ce)(ce)(ce)量(liang)(liang)(liang)電(dian)(dian)(dian)壓(ya)(ya)(ya)(ya)(ya)。
五、面板結構(gou)說(shuo)明
1、操作箱面板
控制箱為箱式鋁(lv)(lv)合(he)金(jin)結(jie)構,面板采用拉絲(si)鋁(lv)(lv)合(he)金(jin)工藝,所(suo)有(you)電(dian)器元件(jian)均(jun)裝在(zai)骨架上(shang),便于(yu)安裝和維修。面板元件(jian)布(bu)置如下:
2、操作(zuo)臺面板
操作臺為臺式結(jie)(jie)構(gou),殼體為冷扎(zha)鋼板結(jie)(jie)構(gou),面(mian)板采用鋁合(he)金拉絲工藝,面(mian)板元件布置如下:
六、操作指(zhi)南
本裝置在操作之前應根(gen)據不同被試品的(de)容量、電壓等級(ji),先計算好*大工作電流(liu),并(bing)調整電流(liu)保護(hu)器。其試驗接線應參(can)考本說明書中圖(tu)1、圖(tu)2、圖(tu)3、圖(tu)4、圖(tu)5,必須可(ke)靠接地。
1、操作要點
(1)試(shi)驗(yan)(yan)前,應了(le)解被試(shi)品(pin)的試(shi)驗(yan)(yan)電壓,同時了(le)解被試(shi)品(pin)的其(qi)他試(shi)驗(yan)(yan)項(xiang)目及以前的試(shi)驗(yan)(yan)結果。若被試(shi)品(pin)有缺(que)陷或異常,應在消除后再進行(xing)耐壓試(shi)驗(yan)(yan)。
(2)試驗現場應(ying)圍好遮攔或圍繩,掛好標(biao)示牌,并派專人(ren)監護。
(3)試(shi)(shi)驗前,被(bei)(bei)(bei)試(shi)(shi)品表面應(ying)擦(ca)拭干(gan)凈,將被(bei)(bei)(bei)試(shi)(shi)品的(de)外殼(ke)和非被(bei)(bei)(bei)試(shi)(shi)繞組(zu)可靠接地。被(bei)(bei)(bei)試(shi)(shi)品為新沖油(you)設備(bei)時(shi)(shi),應(ying)按《規程》規定使油(you)靜(jing)止一(yi)定時(shi)(shi)間再升壓,對110kV及(ji)以下的(de)充油(you)電力設備(bei),在注滿油(you)后靜(jing)置時(shi)(shi)間應(ying)不少于24小時(shi)(shi),對220kV及(ji)330kV的(de)充油(you)電力設備(bei),靜(jing)置時(shi)(shi)間應(ying)不少于48小時(shi)(shi)。
(4)接(jie)好試驗(yan)接(jie)線(xian)后,應由有經(jing)驗(yan)的人員(yuan)檢查(cha),確認無誤后方可升壓。
(5)升(sheng)壓前,首先檢查(cha)調壓器(qi)是否在(zai)零(ling)位。調壓器(qi)在(zai)零(ling)位方(fang)可升(sheng)壓。
(6)升壓(ya)(ya)過程中不(bu)僅要監(jian)視電(dian)壓(ya)(ya)表的變(bian)(bian)化,還(huan)應(ying)監(jian)視電(dian)流表的變(bian)(bian)化,以及被(bei)試(shi)品電(dian)流的變(bian)(bian)化。升壓(ya)(ya)時要均(jun)勻(yun)升壓(ya)(ya),不(bu)能太快。升至規定試(shi)驗電(dian)壓(ya)(ya)時,開始(shi)計算時間,時間到(dao)后,緩慢均(jun)勻(yun)降(jiang)下電(dian)壓(ya)(ya)。絕不(bu)允許(xu)不(bu)降(jiang)壓(ya)(ya)就先跳開電(dian)源開關。
(7)試驗中發現表針擺(bai)動或被試品有(you)異常聲(sheng)響、冒(mao)煙等應立即(ji)降下電壓(ya),拉開(kai)電源,在高壓(ya)側掛(gua)上接(jie)地線后,再查明原因。
(8)耐(nai)壓試(shi)驗(yan)前后(hou)均應測量被試(shi)品的絕緣電阻。
2、操作(zuo)步驟
(1) 按試(shi)驗要求將控(kong)制部分(fen)、試(shi)驗變壓器、被(bei)試(shi)品(pin)正確接(jie)(jie)好(hao)線,必須可靠(kao)接(jie)(jie)地,請參考圖(tu)(tu)1、圖(tu)(tu)2、圖(tu)(tu)3、圖(tu)(tu)4、圖(tu)(tu)5。
(2) 根(gen)據(ju)試驗的(de)要求,整(zheng)定“時間(jian)繼電(dian)(dian)器”及“過流繼電(dian)(dian)器”。
A 時間繼(ji)電器設置:
T1,T2,T3,T4設置(zhi)0~9任(ren)意數字,T可設置(zhi)為H(小時),M(分鐘),S(秒(miao))。
根據試驗要求,在1S~99H內可以任意設置定時(shi)時(shi)間(jian)。
B 過流繼電器設置:
過流(liu)(liu)(liu)(liu)動作設定值(zhi)=過流(liu)(liu)(liu)(liu)繼電(dian)器(qi)(qi)刻度盤讀數×測量變(bian)(bian)(bian)比(bi)×K,其(qi)中(zhong)K為(wei)電(dian)流(liu)(liu)(liu)(liu)倍率/切(qie)除開關的狀態值(zhi),分別(bie)為(wei)X1,X2,OFF,電(dian)流(liu)(liu)(liu)(liu)倍率/切(qie)除開關處于×1,×2位置時(shi),K值(zhi)分別(bie)為(wei)1、2,切(qie)換(huan)為(wei)OFF擋時(shi),K值(zhi)為(wei)+∞。(注:不要使用OFF檔,因(yin)為(wei)會使變(bian)(bian)(bian)壓(ya)器(qi)(qi)失去過流(liu)(liu)(liu)(liu)保護功(gong)能而導致設備損壞。測量變(bian)(bian)(bian)比(bi)為(wei)電(dian)流(liu)(liu)(liu)(liu)互感器(qi)(qi)的變(bian)(bian)(bian)比(bi),沒有電(dian)流(liu)(liu)(liu)(liu)互感器(qi)(qi)時(shi)為(wei)1)。
(3) 接入電(dian)源,此(ci)時(shi),“電(dian)源燈(deng)(deng)”亮,表示(shi)外部電(dian)源已引入。如“零位燈(deng)(deng)”亮,表示(shi)調(diao)壓器(qi)在零位。如“零位燈(deng)(deng)”不亮,應(ying)逆(ni)時(shi)針旋轉調(diao)節調(diao)壓器(qi)手柄(bing)至“零位燈(deng)(deng)”亮,表示(shi)可進行調(diao)壓操作。
(4)按“啟動(dong)按鈕”。此時,“送電(dian)燈”,“電(dian)源燈”和“零位(wei)燈”亮;進入送電(dian)狀態。
(5)以(yi)2kV/S勻速順時(shi)針旋轉調壓器手柄至被試(shi)(shi)品規定(ding)的耐(nai)壓值,并密切(qie)注視(shi)電流表(直(zhi)流耐(nai)壓試(shi)(shi)驗時(shi),同時(shi)密切(qie)注視(shi)直(zhi)流微安(an)表)。此時(shi),“電源燈”,“工作燈”亮;“零位燈”滅(mie)。
(6)根據試驗啟動“計時按鈕(niu)”,計時開(kai)始,并注意被試品的情(qing)況。
(7)當耐壓(ya)計時到時,操作(zuo)臺(tai)自(zi)動聲(sheng)光報警。應立即逆時針旋轉調壓(ya)器手柄至零位,按(an)(an)下(xia)停止按(an)(an)鈕和(he)解(jie)除計時按(an)(an)鈕自(zi)鎖狀態。此時“電源燈”, “零位燈”亮,“工(gong)作(zuo)燈”滅。試驗即告完畢
(8)拔掉電源(yuan),拆除接線,試驗結(jie)束。
(9)在升壓(ya)或耐壓(ya)過(guo)程中,如發生短路、閃(shan)絡、擊穿過(guo)流時(shi)(shi),過(guo)流繼電器(qi)動作(zuo),切斷(duan)主回路。此時(shi)(shi)應將調壓(ya)器(qi)逆(ni)時(shi)(shi)針旋(xuan)轉至零(ling)位,切斷(duan)電源(yuan),并查明(ming)原(yuan)因,并作(zuo)詳細記錄(lu)。
(10)試(shi)(shi)驗完畢,降壓,切斷(duan)電源后應用(yong)放**將被試(shi)(shi)品及試(shi)(shi)驗裝置本身(shen)充分放電。
七、產品維(wei)護(hu)
1、開箱驗收(shou)時,應檢查主控回路接(jie)線是否松(song)動,調壓(ya)器電(dian)刷是否接(jie)觸良好;
2、長期不用時,使(shi)用前應(ying)用500V兆歐表(biao)測量絕緣電阻,其阻值不低于0.5MΩ;
3、電(dian)源(yuan)電(dian)壓(ya)應符(fu)合控制箱(臺)銘牌上(shang)的(de)輸入電(dian)壓(ya)值;
4、本(ben)裝置(zhi)設(she)有過電流(liu)保(bao)護(hu),出廠已(yi)調整為(wei)額(e)定(ding)電流(liu)的(de)50%。用于(yu)小負載時,應根據被試品的(de)額(e)定(ding)容量(liang)電流(liu)重新設(she)定(ding);
5、使用完(wan)畢后,應關好(hao)控(kong)制(zhi)箱(臺)門,以保持(chi)控(kong)制(zhi)箱(臺)內部(bu)清潔。
八、注(zhu)意事項(xiang)
1、按照您(nin)所進行的(de)試驗接(jie)好(hao)工作線路。試驗變壓器的(de)外殼以及操(cao)作系統的(de)外殼必須可(ke)靠接(jie)地。試驗變壓器的(de)高壓繞組(zu)的(de)X端(高壓尾(wei))以及測(ce)量繞組(zu)的(de)F端必須可(ke)靠接(jie)地。
2、做串級(ji)試(shi)驗(yan)(yan)時,**級(ji)、第(di)(di)三級(ji)試(shi)驗(yan)(yan)變壓(ya)器(qi)的低壓(ya)繞(rao)組(zu)成X端(duan),測(ce)量繞(rao)組(zu)的F端(duan)以及高壓(ya)繞(rao)組(zu)的X端(duan)(高壓(ya)端(duan))均接本級(ji)試(shi)驗(yan)(yan)變壓(ya)器(qi)具外殼。**級(ji)、第(di)(di)三級(ji)試(shi)驗(yan)(yan)變壓(ya)器(qi)的外殼必須通過絕緣支(zhi)架接地(di)。
3、接通電(dian)(dian)源前,操作系統(tong)的(de)(de)調壓(ya)(ya)(ya)器(qi)必須(xu)調到(dao)零位后(hou)(hou)方(fang)可接通電(dian)(dian)源,合閘,開始(shi)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)。從零開始(shi)勻速旋轉調壓(ya)(ya)(ya)器(qi)手輪升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)。升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)方(fang)式有:快速升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)法(fa),即(ji)20s逐級(ji)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)法(fa);慢速升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)法(fa),即(ji)60s逐級(ji)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)法(fa);極(ji)慢速升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)法(fa)供(gong)選用。電(dian)(dian)壓(ya)(ya)(ya)從零開始(shi)按一定(ding)(ding)的(de)(de)升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)方(fang)式和速度上升(sheng)(sheng)(sheng)(sheng)到(dao)您所(suo)需(xu)的(de)(de)額(e)定(ding)(ding)試(shi)(shi)(shi)驗電(dian)(dian)壓(ya)(ya)(ya)的(de)(de)75%后(hou)(hou),再以每秒2%額(e)定(ding)(ding)試(shi)(shi)(shi)驗電(dian)(dian)壓(ya)(ya)(ya)的(de)(de)速度升(sheng)(sheng)(sheng)(sheng)到(dao)您所(suo)需(xu)的(de)(de)試(shi)(shi)(shi)驗電(dian)(dian)壓(ya)(ya)(ya),并密切(qie)注(zhu)意測量(liang)儀表的(de)(de)及被(bei)試(shi)(shi)(shi)品的(de)(de)情(qing)況。升(sheng)(sheng)(sheng)(sheng)壓(ya)(ya)(ya)過程中(zhong)或試(shi)(shi)(shi)驗過程中(zhong)如發(fa)現測量(liang)儀表的(de)(de)指示(shi)及被(bei)試(shi)(shi)(shi)品情(qing)況異(yi)常,應立即(ji)降(jiang)壓(ya)(ya)(ya),切(qie)斷電(dian)(dian)源,查明情(qing)況。
4、試驗完畢后(hou),應在數(shu)(shu)秒(miao)內(nei)勻速的將(jiang)調壓器返(fan)回至零位(wei),然后(hou)切斷(duan)電源。本產品不得超過額定參數(shu)(shu)使用。
5、使(shi)用本(ben)(ben)產品做高壓試驗(yan)時,除熟悉本(ben)(ben)說明(ming)書外,還必須嚴格執行(xing)國家有關標準和操(cao)作規程。可參照GB311.1 – 97《高壓輸變設備的(de)絕緣配合,高壓試驗(yan)技術(shu)》;《電氣設備預防性試驗(yan)規程》等
一、概(gai)述
智(zhi)能耐壓(ya)試(shi)(shi)驗(yan)裝置是根據國家(jia)*新電力(li)行(xing)(xing)業標(biao)準而設計的(de)(de)、性(xing)能先進的(de)(de)智(zhi)能型耐壓(ya)試(shi)(shi)驗(yan)設備,用于對(dui)各種電器產(chan)品、電氣(qi)元(yuan)件(jian)、絕(jue)緣(yuan)材料等(deng)進行(xing)(xing)規定電壓(ya)下的(de)(de)絕(jue)緣(yuan)強度試(shi)(shi)驗(yan),以(yi)考核產(chan)品的(de)(de)絕(jue)緣(yuan)水平(ping),發現(xian)被試(shi)(shi)品的(de)(de)絕(jue)緣(yuan)缺陷,衡量(liang)過電壓(ya)的(de)(de)能力(li)。廣泛應用于電工(gong)制造(zao)部門、電力(li)運(yun)行(xing)(xing)部門、科研(yan)單(dan)位和高等(deng)院(yuan)校。
二、產品(pin)特點
1. 320×240液晶顯示器(qi)、高速熱敏(min)打印機。
2. 高(gao)(gao)壓(ya)(ya)電壓(ya)(ya)、高(gao)(gao)壓(ya)(ya)電流(liu)、低壓(ya)(ya)電壓(ya)(ya)、低壓(ya)(ya)電流(liu)4路測量方式,高(gao)(gao)精(jing)度傳感器和高(gao)(gao)性能14位AD采(cai)集芯片。
3. 人機對話全(quan)鍵盤操(cao)作(zuo)(zuo)方式(shi),智能化(hua)工作(zuo)(zuo)全(quan)過(guo)程,任選自動方式(shi)和手動方式(shi)。
4. 實(shi)時顯示高(gao)壓(ya)(ya)電(dian)壓(ya)(ya)、高(gao)壓(ya)(ya)電(dian)流(liu)、低(di)壓(ya)(ya)電(dian)壓(ya)(ya)、低(di)壓(ya)(ya)電(dian)流(liu),時間及耐壓(ya)(ya)結(jie)果,顯示直觀明了(le)。
5. 完善的過(guo)壓(ya)、過(guo)流(liu)(liu)保護,任意(yi)設定輸出電壓(ya)、高壓(ya)電流(liu)(liu)上(shang)限、低壓(ya)電流(liu)(liu)上(shang)限和(he)計時(shi)時(shi)間。
6. 具有(you)回(hui)零檢(jian)測功(gong)能(neng),回(hui)零確定后(hou)才可(ke)進行試驗(yan),**可(ke)靠。
7. 具有(you)絕(jue)(jue)緣電阻(zu)測試功能(neng),直(zhi)接反映被試品絕(jue)(jue)緣強度。
8. 逼近式調(diao)壓算法,到(dao)達設定電壓后(hou)自動耐壓計時(shi),計時(shi)結束后(hou)自動降壓回零。
9. 超過設(she)定高壓電流(liu)或低壓電流(liu)時自動切斷電壓輸出,降壓回(hui)零,并發生(sheng)聲光報警。
10. 精(jing)良的軟硬(ying)件(jian)抗(kang)(kang)干(gan)(gan)擾設計,多種抗(kang)(kang)干(gan)(gan)擾手段,適(shi)應惡劣電磁環境。
11. 自動錯誤診斷,易于發現和解決問題。
12. 可選配(pei)無線遙控控制功能(neng)、遠程通信、門聯鎖警鈴、外接分壓器校(xiao)驗接口等。
三、設備組成(cheng)
1、選型(xing)配置
標準配置(zhi)
|
□ 分體(ti)式(shi)
|
操作部分:
□箱(xiang)式(不(bu)大于5kVA) / □臺式
容量: kVA(小于200kVA)
輸(shu)入:□AC220V / □AC380V
|
試驗變(bian)壓器:
□交(jiao)流 / □交(jiao)直流
□油(you)變(bian) / □干變(bian) / □氣變(bian)
容量: kVA(小于(yu)200kVA)
輸出:AC kV(小于300kVA)
|
□ 一體式
|
□箱(xiang)式(不大(da)于(yu)20kV) / □臺(tai)式(不大(da)于(yu)30kV)
容量: kVA(小(xiao)于300kVA)
輸(shu)入:□AC220V / □AC380V 輸(shu)出:AC kV(不大于30kV)
|
客戶選配
|
□標準高壓分(fen)壓器(qi)
|
□保(bao)護球隙
|
□直流(liu)微安表(biao)
|
□放**
|
□保護(hu)水阻
|
□高壓濾(lv)波電容(rong)
|
其(qi)它:
|
2、對應實物(wu)
四、技術指標
1、使用條件:
(1)工作場(chang)所應(ying)無嚴重影響絕(jue)緣的氣體、蒸汽、化學性塵埃及(ji)其(qi)它爆炸性和腐蝕性介質。
(2)環境溫度 -20~+50℃
(3)環境濕度(du) ≤85% RH(無凝(ning)結(jie)水)
2、控制箱(臺)參數:(常規(gui)參數見下(xia)表(biao))
(1)計時(shi)范圍:0-999S
(3)電(dian)壓精度 ≤1.5% ±1個字(F.S)
(4)電流精度 ≤1.5% ±1個字(F.S)
規格
|
容量
|
輸 入(ru) 電(dian) 源(yuan)
|
輸 出(chu) 電 壓
|
重量(liang)(kg)
|
相數
|
(V)
|
(A)
|
(V)
|
(A)
|
2/220
|
2
|
1
|
220
|
10
|
0-250
|
8
|
14
|
3/220
|
3
|
1
|
220
|
15
|
0-250
|
12
|
16
|
5/220
|
5
|
1
|
220
|
25
|
0-250
|
20
|
18
|
10/220
|
10
|
1
|
220
|
50
|
0-250
|
40
|
80
|
15/380
|
15
|
2
|
380
|
37.5
|
0-430
|
34.8
|
90
|
20/380
|
20
|
2
|
380
|
50
|
0-430
|
46.5
|
100
|
25/380
|
25
|
2
|
380
|
62.5
|
0-430
|
58.1
|
120
|
30/380
|
30
|
2
|
380
|
75
|
0-430
|
69.7
|
140
|
50/380
|
50
|
2
|
380
|
125
|
0-430
|
116.2
|
160
|
100/380
|
100
|
2
|
380
|
250
|
0-430
|
232.5
|
250
|
說(shuo)明:如有特(te)殊參(can)數(shu)要求,可按用戶的技術參(can)數(shu)進(jin)行設計(ji)制作。
3、試驗(yan)變壓器參數(shu):(常規參數(shu)見下表)
規(gui)格
|
容量
kVA
|
低壓側
|
高(gao)壓側
|
高壓側(交(jiao)直(zhi)流變壓器)
|
測量變比(bi)
|
60分鐘溫升℃
|
阻抗電壓%
|
空載(zai)電流
%
|
質(zhi)量
kg
|
電壓
V
|
電(dian)流
A
|
交流輸出
|
直流輸出
|
電壓(ya)kV
|
電流
|
電壓kV
|
電流
|
1.5/50
|
1.5
|
200
|
7.5
|
50
|
30
|
70
|
21.4
|
500
|
50
|
10
|
<4
|
19.5
|
3/50
|
3
|
200
|
15
|
50
|
60
|
70
|
42.9
|
500
|
50
|
10
|
<4
|
27
|
5/50
|
5
|
200
|
25
|
50
|
100
|
70
|
71.4
|
500
|
50
|
10
|
<4
|
52
|
10/50
|
10
|
200
|
50
|
50
|
200
|
70
|
142.9
|
500
|
50
|
10
|
<4
|
80
|
15/50
|
15
|
400
|
37.5
|
50
|
300
|
70
|
214.3
|
500
|
50
|
8
|
<4
|
120
|
20/50
|
20
|
400
|
50
|
50
|
400
|
70
|
285.7
|
500
|
50
|
8
|
<4
|
140
|
30/50
|
30
|
400
|
75
|
50
|
600
|
70
|
428.6
|
500
|
50
|
8
|
<4
|
155
|
50/50
|
50
|
400
|
125
|
50
|
1000
|
70
|
714.3
|
500
|
50
|
8
|
<4
|
184
|
10/100
|
10
|
200
|
50
|
100
|
100
|
140
|
71.4
|
1000
|
50
|
10
|
<4
|
135
|
15/100
|
15
|
400
|
37.5
|
100
|
150
|
140
|
107.1
|
1000
|
50
|
8
|
<4
|
150
|
20/100
|
20
|
400
|
50
|
100
|
200
|
140
|
142.9
|
1000
|
50
|
8
|
<4
|
215
|
30/100
|
30
|
400
|
75
|
100
|
300
|
140
|
214.3
|
1000
|
50
|
8
|
<4
|
250
|
50/100
|
50
|
400
|
125
|
100
|
500
|
140
|
357.1
|
1000
|
50
|
8
|
<4
|
290
|
10/150
|
10
|
200
|
50
|
100
|
66.7
|
140
|
47.6
|
1500
|
50
|
10
|
<4
|
180
|
15/150
|
15
|
400
|
37.5
|
150
|
100
|
210
|
71.4
|
1500
|
50
|
8
|
<4
|
200
|
20/150
|
30
|
400
|
50
|
150
|
133.3
|
210
|
95.2
|
1500
|
50
|
8
|
<4
|
220
|
30/150
|
30
|
400
|
75
|
150
|
200
|
210
|
142.9
|
1500
|
50
|
8
|
<4
|
280
|
50/150
|
50
|
400
|
125
|
150
|
333.3
|
210
|
238.1
|
1500
|
50
|
8
|
<4
|
340
|
說明:如有特殊參數要求(qiu),可按(an)用戶的技術參數進(jin)行設計制作(zuo)。
上表的重量以油浸式(shi)(shi)試驗變壓(ya)器為例(li),干式(shi)(shi)試驗變壓(ya)器和(he)充(chong)氣式(shi)(shi)試驗變壓(ya)器稍(shao)有不同。
五(wu)、接線及(ji)工作原理
1、調壓部分接線(xian)及原理
調(diao)壓部(bu)分(fen)由控(kong)制(zhi)部(bu)分(fen)和試驗(yan)變(bian)壓器(qi)(qi)組(zu)成。控(kong)制(zhi)部(bu)分(fen)是(shi)由接觸式調(diao)壓器(qi)(qi)、單片機控(kong)制(zhi)系(xi)統、液晶、打印機、信號測量(liang)、電路保護(hu)組(zu)成。試驗(yan)變(bian)壓器(qi)(qi)由低壓繞組(zu)、高壓繞組(zu)、儀(yi)表(biao)繞組(zu)三部(bu)分(fen)組(zu)成。
試驗(yan)變壓器為(wei)交直流(liu)兩用時(shi),試驗(yan)變壓器配置(zhi)(zhi)(zhi)了(le)高(gao)壓硅(gui)堆(油變、氣(qi)(qi)變為(wei)內置(zhi)(zhi)(zhi),干(gan)變為(wei)外置(zhi)(zhi)(zhi)),高(gao)壓可輸出(chu)(chu)交流(liu)和(he)直流(liu)。輸出(chu)(chu)交流(liu)時(shi),要求接入短(duan)路桿(油變、氣(qi)(qi)變)或去(qu)掉外置(zhi)(zhi)(zhi)硅(gui)堆(干(gan)變);輸出(chu)(chu)直流(liu)時(shi),要求擰(ning)出(chu)(chu)短(duan)路桿(油變、氣(qi)(qi)變)或加上外置(zhi)(zhi)(zhi)硅(gui)堆(干(gan)變)
通過接(jie)入工(gong)頻電源,調節調壓(ya)器,以獲得所需要(yao)的(de)試驗(yan)高壓(ya)電壓(ya)值。其工(gong)作原理見圖1:
2、試驗(yan)部分接(jie)線及(ji)原理(li)
做耐(nai)壓(ya)試(shi)驗時,控制部分(fen)(fen)、變壓(ya)器的接地端及高(gao)壓(ya)尾必須可靠接地。有條件的情況下(xia),做工頻耐(nai)壓(ya)試(shi)驗請加上限流電(dian)阻、標準高(gao)壓(ya)分(fen)(fen)壓(ya)器、球隙(xi)保護(hu)電(dian)阻及保護(hu)球隙(xi),如圖3。
做直流耐壓(ya)試驗(yan)請另外加上微安(an)(an)表(biao),微安(an)(an)表(biao)必須接在硅堆和被試器之間,油變(bian)(bian)或氣變(bian)(bian)一般(ban)擰(ning)在高壓(ya)頭上面(要(yao)求擰(ning)出短路桿),干(gan)變(bian)(bian)擰(ning)在外置硅堆上面;為了更準(zhun)確顯示高壓(ya)直流泄(xie)漏電(dian)流,請將分壓(ya)器的高壓(ya)線接在微安(an)(an)表(biao)和硅堆之間,(油變(bian)(bian)、氣變(bian)(bian))如(ru)圖4,(干(gan)變(bian)(bian))如(ru)圖5。
耐壓(ya)(ya)試驗中限(xian)流(liu)電阻R1應根據試驗變壓(ya)(ya)器的(de)額定容(rong)量(liang)(liang)(liang)來選(xuan)擇。如高壓(ya)(ya)側額定輸(shu)出電流(liu)在100~300mA時,可取0.5~1Ω/V(試驗電壓(ya)(ya));高壓(ya)(ya)側額定輸(shu)出電流(liu)為1A以(yi)上時,可取1Ω/V(試驗電壓(ya)(ya))。常(chang)用水(shui)電阻作為限(xian)流(liu)電阻,管(guan)子長度可按150kV/m考慮,管(guan)子粗細應具有足(zu)夠的(de)熱容(rong)量(liang)(liang)(liang)(水(shui)阻液(ye)配制方法:用蒸餾水(shui)加入(ru)適量(liang)(liang)(liang)硫酸(suan)銅(tong)配制成(cheng)各(ge)種不(bu)同的(de)阻值(zhi))。
球(qiu)(qiu)間(jian)(jian)隙(xi)及保(bao)護電(dian)(dian)阻(zu):當電(dian)(dian)壓超過球(qiu)(qiu)間(jian)(jian)隙(xi)整(zheng)定值時(一(yi)般取(qu)(qu)試驗電(dian)(dian)壓的110%~120%),球(qiu)(qiu)間(jian)(jian)隙(xi)放電(dian)(dian),對被試品起到(dao)保(bao)護作(zuo)用。球(qiu)(qiu)間(jian)(jian)隙(xi)保(bao)護電(dian)(dian)阻(zu)可按1Ω/V(試驗電(dian)(dian)壓)選取(qu)(qu)。
在(zai)(zai)工頻耐(nai)壓(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)中,低(di)電(dian)壓(ya)(ya)(ya)(ya)側測量(liang)(liang)電(dian)壓(ya)(ya)(ya)(ya)(儀表(biao)電(dian)壓(ya)(ya)(ya)(ya))不(bu)是非常(chang)準確的(de)(de)(de),其原因(yin)是由于(yu)試(shi)(shi)驗(yan)變壓(ya)(ya)(ya)(ya)器(qi)(qi)存在(zai)(zai)著漏(lou)(lou)(lou)抗(kang)(kang),在(zai)(zai)這個漏(lou)(lou)(lou)抗(kang)(kang)上(shang)(shang)必然(ran)存在(zai)(zai)著壓(ya)(ya)(ya)(ya)降(jiang)或容升(sheng),使試(shi)(shi)品上(shang)(shang)的(de)(de)(de)電(dian)壓(ya)(ya)(ya)(ya)低(di)于(yu)或高于(yu)低(di)壓(ya)(ya)(ya)(ya)側測量(liang)(liang)電(dian)壓(ya)(ya)(ya)(ya)表(biao)上(shang)(shang)反映出來的(de)(de)(de)電(dian)壓(ya)(ya)(ya)(ya)。工頻耐(nai)壓(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)時(shi),被(bei)(bei)試(shi)(shi)品上(shang)(shang)的(de)(de)(de)電(dian)壓(ya)(ya)(ya)(ya)高于(yu)試(shi)(shi)驗(yan)變壓(ya)(ya)(ya)(ya)器(qi)(qi)的(de)(de)(de)輸出電(dian)壓(ya)(ya)(ya)(ya),也就(jiu)是所謂容升(sheng)現象。感應耐(nai)壓(ya)(ya)(ya)(ya)試(shi)(shi)驗(yan)時(shi),試(shi)(shi)驗(yan)變壓(ya)(ya)(ya)(ya)器(qi)(qi)的(de)(de)(de)漏(lou)(lou)(lou)抗(kang)(kang)必然(ran)存在(zai)(zai)著壓(ya)(ya)(ya)(ya)降(jiang)。為了(le)準確測量(liang)(liang)被(bei)(bei)試(shi)(shi)品上(shang)(shang)所施加(jia)的(de)(de)(de)電(dian)壓(ya)(ya)(ya)(ya),因(yin)此常(chang)在(zai)(zai)高壓(ya)(ya)(ya)(ya)側接入標準高壓(ya)(ya)(ya)(ya)分(fen)壓(ya)(ya)(ya)(ya)器(qi)(qi)來測量(liang)(liang)電(dian)壓(ya)(ya)(ya)(ya)。
六(liu)、操作要點
1、試(shi)驗(yan)(yan)(yan)前,應了(le)解被試(shi)品的試(shi)驗(yan)(yan)(yan)電壓,同(tong)時(shi)了(le)解被試(shi)品的其(qi)他試(shi)驗(yan)(yan)(yan)項目及以前的試(shi)驗(yan)(yan)(yan)結果。若被試(shi)品有缺陷或異常,應在消除后(hou)再進行耐壓試(shi)驗(yan)(yan)(yan)。
2、試驗現場應圍(wei)好遮攔或圍(wei)繩,掛(gua)好標(biao)示(shi)牌(pai),并(bing)派(pai)專(zhuan)人監護。
3、試(shi)驗前,被(bei)(bei)試(shi)品表(biao)面(mian)應擦拭干凈,將被(bei)(bei)試(shi)品的外殼和非被(bei)(bei)試(shi)繞組可靠接地。被(bei)(bei)試(shi)品為(wei)新沖油(you)(you)(you)設備(bei)時(shi)(shi),應按(an)《規程》規定(ding)(ding)使油(you)(you)(you)靜(jing)止(zhi)一定(ding)(ding)時(shi)(shi)間(jian)再升壓,對110kV及(ji)以下的充油(you)(you)(you)電力設備(bei),在注滿油(you)(you)(you)后(hou)靜(jing)置時(shi)(shi)間(jian)應不(bu)少于24小(xiao)時(shi)(shi),對220kV及(ji)330kV的充油(you)(you)(you)電力設備(bei),靜(jing)置時(shi)(shi)間(jian)應不(bu)少于48小(xiao)時(shi)(shi)。
4、接好試驗(yan)接線(xian)后(hou),應(ying)由有經驗(yan)的人員檢(jian)查,確認無誤后(hou)方(fang)可升(sheng)壓。
5、升壓前,首先檢查調(diao)壓器(qi)是否在零(ling)位。調(diao)壓器(qi)在零(ling)位方可升壓。
6、升(sheng)(sheng)壓(ya)過程中不(bu)(bu)僅要監(jian)視(shi)電(dian)壓(ya)的(de)(de)變(bian)化,還應監(jian)視(shi)電(dian)流的(de)(de)變(bian)化,以及被試(shi)(shi)品泄漏(lou)電(dian)流的(de)(de)變(bian)化。升(sheng)(sheng)壓(ya)時要均勻(yun)升(sheng)(sheng)壓(ya),不(bu)(bu)能(neng)太快。升(sheng)(sheng)至規(gui)定試(shi)(shi)驗(yan)電(dian)壓(ya)時,開始計時,時間(jian)到后,緩慢均勻(yun)降(jiang)下(xia)電(dian)壓(ya)。絕不(bu)(bu)允許(xu)不(bu)(bu)降(jiang)壓(ya)就先(xian)跳(tiao)開電(dian)源開關。
7、試(shi)驗(yan)中發現被(bei)試(shi)品(pin)有異(yi)常聲響、冒煙等應(ying)立即降下(xia)電(dian)壓,拉開電(dian)源,在高壓側(ce)掛上接地線后,再(zai)查明原因。耐壓試(shi)驗(yan)前后均應(ying)測量被(bei)試(shi)品(pin)的絕緣(yuan)電(dian)阻(zu)。
七、面板功(gong)能說明
打印機(ji):打印機(ji)是(shi)熱敏打印機(ji),當試驗(yan)完成后按鍵盤上(shang)的“打印”按鈕(niu)打印試驗(yan)結果。
RS232:RS232是與計(ji)算機相連的串口通信接口,是用戶選(xuan)配(pei)(pei)接口,本裝置沒(mei)有配(pei)(pei)置這個(ge)接口。
LCD對比度:因(yin)為液晶顯示屏在溫度和光線有所不同(tong)時稍有些變化,可以通過LCD對比度調節背光到(dao)適合亮度。
液晶: 320x240像素(su)點陣白(bai)色背光液晶,在強光和陰(yin)暗環境下都十分清楚。
指示(shi)燈(deng):由啟動燈(deng)、零(ling)位燈(deng)、指示(shi)燈(deng)三(san)個燈(deng)組成(cheng),啟動燈(deng)和警(jing)示(shi)燈(deng)是(shi)高(gao)亮七彩(cai)燈(deng)。
操作提(ti)示(shi):有一些簡短的提(ti)示(shi)語(yu)句和安裝接線圖。
緊急(ji)開(kai)關:在緊急(ji)情況(kuang)下(xia)按此開(kai)關,即可以切斷(duan)變壓器(qi)電源,也可以切斷(duan)工(gong)作電源。(箱式安(an)裝在面板上,臺式安(an)裝在柜體上)
鍵盤:由上、下、左、右、設(she)置、打印(yin)、確(que)定、取消(xiao)8個鍵組(zu)成,是用戶(hu)和設(she)備(bei)交互的終(zhong)端(duan)。
電源開(kai)關(guan):工(gong)作電源,帶通電指示燈。
八、軟(ruan)件使用說明
按試(shi)驗要求(qiu)將控制部分、試(shi)驗變壓(ya)器(qi)、被試(shi)品正確(que)接(jie)好線,必須(xu)可靠接(jie)地,請參考(kao)圖1、圖2、圖3、圖4、圖5。
1、開機使(shi)用
開機處(chu)于“歡迎界(jie)面(mian)”,如圖7:
根據鍵盤的示圖8,按上(shang)↑、下↓、左(zuo)←,右→可以切(qie)換“自(zi)動(dong)耐(nai)壓(ya)試驗(yan)”或(huo)“手(shou)動(dong)耐(nai)壓(ya)試驗(yan)”,在“自(zi)動(dong)試驗(yan)”或(huo)“手(shou)動(dong)試驗(yan)”里面選擇“交(jiao)流試驗(yan)方式”或(huo)“直(zhi)流試驗(yan)方式”。如圖9
說(shuo)明:
(1)當配置的是交直(zhi)流兩用控制部分時,使(shi)用直(zhi)流輸(shu)出(chu)時軟件操(cao)作(zuo)請進(jin)入直(zhi)流試驗(yan)方式,交流輸(shu)出(chu)時軟件操(cao)作(zuo)請進(jin)入交流試驗(yan)方式,如果選擇(ze)錯誤會(hui)導致儀器顯示電(dian)壓會(hui)和輸(shu)出(chu)實際電(dian)壓不一致。
(2)當(dang)(dang)配置的(de)是(shi)交直流兩用變壓器(qi)時,使用直流時請將(jiang)變壓器(qi)的(de)短路桿取出,當(dang)(dang)使用交流時請將(jiang)短路桿插入(ru)擰緊。
(3)如果配置(zhi)的(de)是交(jiao)流控(kong)制部分(fen)時,軟(ruan)件界面(mian)里就沒有交(jiao)直流試驗方式(如圖9)的(de)選擇項。
選中試驗方式后(hou),按確定可以進入主界面,如圖10:
動態(tai)顯(xian)示區:一直處于采集信號,并顯(xian)示高壓(ya)電(dian)壓(ya)、高壓(ya)電(dian)流、低壓(ya)電(dian)壓(ya)、低壓(ya)電(dian)流。
結果顯(xian)示區(qu):如果試驗(yan)沒(mei)有被擊(ji)穿(chuan)時,顯(xian)示平(ping)(ping)均高壓(ya)(ya)(ya)電(dian)(dian)(dian)壓(ya)(ya)(ya),平(ping)(ping)均高壓(ya)(ya)(ya)電(dian)(dian)(dian)流(liu),平(ping)(ping)均低(di)壓(ya)(ya)(ya)電(dian)(dian)(dian)壓(ya)(ya)(ya),平(ping)(ping)均低(di)壓(ya)(ya)(ya)電(dian)(dian)(dian)流(liu),絕緣電(dian)(dian)(dian)阻;否之,顯(xian)示峰(feng)值電(dian)(dian)(dian)壓(ya)(ya)(ya),峰(feng)值電(dian)(dian)(dian)流(liu),低(di)壓(ya)(ya)(ya)電(dian)(dian)(dian)壓(ya)(ya)(ya),低(di)壓(ya)(ya)(ya)電(dian)(dian)(dian)流(liu)。
設置數(shu)據區:設置試驗(yan)中(zhong)需(xu)要(yao)的(de)參數(shu)數(shu)據輸出電(dian)(dian)(dian)壓(ya)為在自(zi)動方式(shi)下(xia)的(de)升(sheng)壓(ya)目標耐壓(ya)值耐壓(ya)時(shi)間為耐壓(ya)過(guo)(guo)程(cheng)的(de)時(shi)間長(chang)度電(dian)(dian)(dian)流(liu)(liu)上(shang)限為高壓(ya)電(dian)(dian)(dian)流(liu)(liu)峰(feng)值的(de)上(shang)限,高壓(ya)電(dian)(dian)(dian)流(liu)(liu)超(chao)(chao)過(guo)(guo)電(dian)(dian)(dian)流(liu)(liu)上(shang)限將認(ren)為擊穿(chuan)過(guo)(guo)流(liu)(liu)保護(hu)為低(di)壓(ya)電(dian)(dian)(dian)流(liu)(liu)峰(feng)值的(de)上(shang)限,低(di)壓(ya)電(dian)(dian)(dian)流(liu)(liu)超(chao)(chao)過(guo)(guo)過(guo)(guo)流(liu)(liu)保護(hu)將認(ren)為擊穿(chuan)
信(xin)(xin)息顯(xian)示區:顯(xian)示試(shi)驗過程中的試(shi)驗狀態(tai)和提(ti)示信(xin)(xin)息。
試(shi)驗操作區:選(xuan)擇(ze)設置(zhi)、試(shi)驗、回(hui)零命令。
2、設置參數
在主(zhu)界(jie)面(mian)上,選中“設置(zhi)”,然后(hou)按確定(ding)后(hou)進(jin)入設置(zhi)界(jie)面(mian),如(ru)圖11:
按(an)(an)左←,右→時切換光標移動(dong)位(wei)置(zhi),按(an)(an)上(shang)↑、下↓時更改光標位(wei)置(zhi)數(shu)據的(de)(de)值(zhi)。光標位(wei)置(zhi)和設(she)置(zhi)的(de)(de)數(shu)值(zhi)全部可(ke)以(yi)自動(dong)循環,前且在使用(yong)時有默認的(de)(de)標準值(zhi)。如果所有的(de)(de)參數(shu)都設(she)置(zhi)完成,按(an)(an)取消退出(chu)設(she)置(zhi)回到主界面開(kai)始狀態。
3、手(shou)動(dong)試驗
零(ling)(ling)位檢查(cha)—當(dang)選中“試驗(yan)”后,按確(que)定就進入(ru)提示(shi)試驗(yan)狀態(tai)。如果調壓器不在(zai)零(ling)(ling)位,將提示(shi)“試驗(yan)前請(qing)先(xian)回零(ling)(ling)”,退出試驗(yan)并且(qie)切換(huan)到(dao)回零(ling)(ling)命令。
試驗過程—回零(ling)確認(ren)后(hou),可以進行試驗。選中“試驗”后(hou)按確定,接觸器(qi)合閘,這時輸(shu)出電壓幾乎為0,如圖(tu)12:
按上↑,高壓(ya)電壓(ya)將不(bu)斷升壓(ya),松開就停(ting)止升壓(ya),如果(guo)到上限就提示滿量程;
按下↓,高(gao)壓(ya)電壓(ya)將不斷降壓(ya),松開就停止降壓(ya),如(ru)果到下限就提示已回零;
按計(ji)時←,計(ji)時開(kai)始工(gong)作(zuo),到耐壓時間計(ji)時結束完成試驗;
按取消→,取消試驗(yan)過程;
在升(sheng)壓(ya)(ya)(ya)(ya)過(guo)(guo)(guo)程中(zhong),如果高(gao)壓(ya)(ya)(ya)(ya)電流(liu)峰(feng)(feng)值(zhi)(zhi)超(chao)(chao)(chao)過(guo)(guo)(guo)“電流(liu)上(shang)限(xian)(xian)”值(zhi)(zhi)或(huo)低(di)壓(ya)(ya)(ya)(ya)電流(liu)峰(feng)(feng)值(zhi)(zhi)超(chao)(chao)(chao)過(guo)(guo)(guo)“過(guo)(guo)(guo)流(liu)保護”值(zhi)(zhi)將認為(wei)被試(shi)品被擊穿(chuan)(chuan),接觸器立(li)刻分閘并顯示試(shi)驗(yan)結(jie)(jie)果,包括峰(feng)(feng)值(zhi)(zhi)電壓(ya)(ya)(ya)(ya)、峰(feng)(feng)值(zhi)(zhi)電流(liu)、低(di)壓(ya)(ya)(ya)(ya)電流(liu)等,調壓(ya)(ya)(ya)(ya)器開始回零,回零完成試(shi)驗(yan)結(jie)(jie)束。如果在耐(nai)壓(ya)(ya)(ya)(ya)過(guo)(guo)(guo)程中(zhong),高(gao)壓(ya)(ya)(ya)(ya)電流(liu)和(he)低(di)壓(ya)(ya)(ya)(ya)電流(liu)峰(feng)(feng)值(zhi)(zhi)沒有超(chao)(chao)(chao)設置上(shang)限(xian)(xian)值(zhi)(zhi),認為(wei)被試(shi)品未擊穿(chuan)(chuan),結(jie)(jie)果顯示區就顯示耐(nai)壓(ya)(ya)(ya)(ya)電壓(ya)(ya)(ya)(ya)、高(gao)壓(ya)(ya)(ya)(ya)電流(liu)、低(di)壓(ya)(ya)(ya)(ya)電流(liu)、絕(jue)緣電阻(zu)等,調壓(ya)(ya)(ya)(ya)器開始回零,回零完成后接觸器分閘試(shi)驗(yan)結(jie)(jie)束。
4、自(zi)動試驗
自動試驗(yan)和手(shou)動試驗(yan)的試驗(yan)過程(cheng)類似,首先(xian)也進行回零檢查,確認后進入如下界(jie)面(mian),如圖13:
按上方法切換到“開始”確定后進(jin)行試驗(yan),與手(shou)動(dong)試驗(yan)不同(tong)之處就是升壓過程將自動(dong)升壓到“輸出電壓”值,然后進(jin)行計時(shi)。
升壓(ya)過(guo)程為(wei)逼(bi)近(jin)方式,首先升到(dao)到(dao)接近(jin)目標值,然后再進行(xing)微調,保(bao)證高壓(ya)電壓(ya)值幾乎(hu)為(wei)輸出電壓(ya)值。
5、功(gong)能選擇
按鍵盤上(shang)的“設置(zhi)”就進入功能界面,如圖(tu)14:
進入功能界(jie)面后(hou),可(ke)以(yi)選(xuan)擇“時鐘(zhong)設置”、“注意(yi)事項(xiang)”等(deng)界(jie)面。
時(shi)(shi)鐘設置(zhi):設置(zhi)時(shi)(shi)鐘的時(shi)(shi)間,為打印報表(biao)提供時(shi)(shi)間依(yi)據。
注意事(shi)項(xiang)(xiang):為用戶(hu)提(ti)供(gong)一些操作規范和**注意事(shi)項(xiang)(xiang)。
6、打印
按鍵盤“打印”按鍵可以打印試驗(yan)果,在此不贅述。
七、產品維護
1、開箱驗收(shou)時,應(ying)檢(jian)查主控(kong)回路接線是否松(song)動,調壓器電刷是否接觸良好(hao)。
2.、長期不用時,使用前(qian)應用500V兆歐表測量絕緣(yuan)電阻,其(qi)阻值不低于0.5MΩ。
3、電(dian)源電(dian)壓應(ying)符合控制箱(臺)說明書上的輸(shu)入(ru)電(dian)壓值要求。
4、本(ben)控制箱(xiang)(臺)設有(you)過電(dian)流保護,出廠已(yi)調整為額定電(dian)流的(de)50%。用(yong)于小負載時,應根據被試品的(de)額定容(rong)量(liang)電(dian)流重新設定;
5、使用完(wan)畢(bi)后,應關好控制(zhi)箱(臺)門蓋,以保(bao)持內(nei)部清潔。
八、注意事項
1、按照您(nin)所進行(xing)的(de)試(shi)(shi)驗接(jie)好工(gong)作(zuo)線(xian)路。試(shi)(shi)驗變壓(ya)(ya)器的(de)外(wai)(wai)殼以及(ji)操作(zuo)系統的(de)外(wai)(wai)殼必須可(ke)靠接(jie)地(di)。試(shi)(shi)驗變壓(ya)(ya)器的(de)測(ce)量繞組的(de)F端和外(wai)(wai)殼必須可(ke)靠接(jie)地(di)。
2、做串級(ji)(ji)試驗時,**級(ji)(ji)、第(di)三(san)級(ji)(ji)試驗變(bian)壓(ya)(ya)(ya)器(qi)的(de)低壓(ya)(ya)(ya)繞組成X端(duan)(duan),測(ce)量繞組的(de)F端(duan)(duan)以及高壓(ya)(ya)(ya)繞組的(de)X端(duan)(duan)(高壓(ya)(ya)(ya)端(duan)(duan))均(jun)接(jie)本級(ji)(ji)試驗變(bian)壓(ya)(ya)(ya)器(qi)具外殼(ke)。**級(ji)(ji)、第(di)三(san)級(ji)(ji)試驗變(bian)壓(ya)(ya)(ya)器(qi)的(de)外殼(ke)必須通(tong)過絕緣支架(jia)接(jie)地。
接通電源前,控制箱(臺)的調壓(ya)器必須調到零位后方(fang)可(ke)接通電源,合閘(zha),開始(shi)升壓(ya)。
3、從零(ling)(ling)開(kai)始勻速旋轉調(diao)壓(ya)(ya)(ya)(ya)器手(shou)輪(lun)升(sheng)(sheng)壓(ya)(ya)(ya)(ya)。升(sheng)(sheng)壓(ya)(ya)(ya)(ya)方式(shi)有:快速升(sheng)(sheng)壓(ya)(ya)(ya)(ya)法(fa)(fa)(fa),即20s逐級升(sheng)(sheng)壓(ya)(ya)(ya)(ya)法(fa)(fa)(fa);慢(man)速升(sheng)(sheng)壓(ya)(ya)(ya)(ya)法(fa)(fa)(fa),即60s逐級升(sheng)(sheng)壓(ya)(ya)(ya)(ya)法(fa)(fa)(fa);極(ji)慢(man)速升(sheng)(sheng)壓(ya)(ya)(ya)(ya)法(fa)(fa)(fa)供選(xuan)用。電(dian)壓(ya)(ya)(ya)(ya)從零(ling)(ling)開(kai)始按一定(ding)的(de)(de)升(sheng)(sheng)壓(ya)(ya)(ya)(ya)方式(shi)和速度(du)上(shang)升(sheng)(sheng)到您所(suo)需的(de)(de)額定(ding)試驗(yan)電(dian)壓(ya)(ya)(ya)(ya)的(de)(de)75%后,再以每秒2%額定(ding)試驗(yan)電(dian)壓(ya)(ya)(ya)(ya)的(de)(de)速度(du)升(sheng)(sheng)到您所(suo)需的(de)(de)試驗(yan)電(dian)壓(ya)(ya)(ya)(ya),并密切注意測量儀(yi)表的(de)(de)及(ji)被試品(pin)的(de)(de)情況。升(sheng)(sheng)壓(ya)(ya)(ya)(ya)過(guo)程(cheng)中或試驗(yan)過(guo)程(cheng)中如發(fa)現測量儀(yi)表的(de)(de)指示及(ji)被試品(pin)情況異常,應立即降壓(ya)(ya)(ya)(ya),切斷電(dian)源(yuan),查明情況。
4、試(shi)驗完畢后(hou),應在等調壓器返回(hui)至(zhi)零位(wei),然后(hou)切斷電源。
5、本(ben)產品不得超過額定(ding)參數使(shi)用。
6、使用本產品做高(gao)壓試驗(yan)時(shi),除熟悉(xi)本說明書(shu)外,還必須嚴格執行國家有關標準和操作規程。可參(can)照(zhao)GB311.1 – 97《高(gao)壓輸(shu)變設備的絕緣(yuan)配合,高(gao)壓試驗(yan)技術(shu)》;《電氣設備預防性試驗(yan)規程》等。
7、控制(zhi)箱(臺)應與試驗變壓器配套(tao)使(shi)用,控制(zhi)箱(臺)的(de)使(shi)用方法,請詳(xiang)細參閱控制(zhi)器的(de)使(shi)用說明(ming)書。