高壓電橋

如果您(nin)對該產品感興趣的話,可以
產品名稱: 高壓電橋(qiao)
產品型號: WBST-600
產品展商: 其它品牌(pai)
產品文檔: 無相(xiang)關(guan)文檔


簡單介紹

WBST-600高壓電橋采用開關電源構成高壓恒流源,空載電壓15kV,短路電流30mA。采用高靈敏度放大器及檢流計指 示平衡,與比例電位器構成平衡電橋,整體置于高電位。高壓電橋測量電纜為特別設計的雙芯高壓橡皮電纜,四 端電阻測量法避免了引線電阻引入的誤差,電纜通過編織屏蔽層可靠接地,面板上操作鈕處于地電位, 通過絕緣桿操作電橋。高壓恒流源和電橋集成在一個便攜式鋁合金箱內。因此,該設備電壓高、重量輕、 操作方便、使用**。

高壓電橋的詳細介紹

1WBST-600高壓電橋(qiao)描(miao)述

1.1簡(jian)介

高壓電纜故(gu)障定位電橋是(shi)基于MURRAY電(dian)橋(qiao)原理而設(she)計,適用于敷設(she)后各種電(dian)線電(dian)纜的(de)(de)擊(ji)穿(chuan)點及沒(mei)有(you)擊(ji)穿(chuan)但絕緣電(dian)阻值偏低的(de)(de)缺(que)陷點的(de)(de)定位,也(ye)是高(gao)壓電(dian)纜護套故障定位*有(you)效的(de)(de)方法。當然,也(ye) 可(ke)用于電(dian)纜廠內各種線纜缺(que)陷點的(de)(de)定位。

設備采(cai)用開(kai)關電(dian)源構成高壓恒流源,空載電(dian)壓15kV,短路電流30mA。采(cai)用(yong)高(gao)靈敏(min)度(du)放大(da)器及檢流計指 示平衡,與比例電(dian)(dian)(dian)位器構成平衡電(dian)(dian)(dian)橋(qiao),整體置于高(gao)電(dian)(dian)(dian)位。測量電(dian)(dian)(dian)纜為特別設計的雙芯高(gao)壓橡(xiang)皮電(dian)(dian)(dian)纜,四 端電(dian)(dian)(dian)阻(zu)測量法避(bi)免(mian)了引線電(dian)(dian)(dian)阻(zu)引入(ru)的誤差,電(dian)(dian)(dian)纜通(tong)過(guo)編織(zhi)屏(ping)蔽層可靠接地,面板上操作(zuo)鈕處(chu)于地電(dian)(dian)(dian)位, 通(tong)過(guo)絕(jue)緣桿操作(zuo)電(dian)(dian)(dian)橋(qiao)。高(gao)壓恒流源和(he)電(dian)(dian)(dian)橋(qiao)集成在一(yi)個(ge)便攜式鋁合金箱(xiang)內。因此,該設備(bei)電(dian)(dian)(dian)壓高(gao)、重量輕、 操作(zuo)方便、使用(yong)**。

1.2功能(neng)

具有三種功能(neng):

1、直流耐壓試驗(yan)

可輸出    015kV 直流電壓,可(ke)用于電纜直流耐壓試驗。

2、燒穿故障點

燒穿及(ji)降低(di)高阻及(ji)閃(shan)絡型故障(zhang)點的電(dian)阻。

3、故障預定位

利用電橋原理進(jin)行預定位,四端電阻測量法避免(mian)了引線電阻引入的誤差。

1.3適(shi)用用戶(hu)

高壓電纜外護(hu)套故障測(ce)距(ju)儀特(te)別適用于:

1、敷設后電纜(lan)的高(gao)(gao)阻擊穿點(dian),特別是難(nan)以燒成低阻的線性高(gao)(gao)阻擊穿點(dian)如(ru)電纜(lan)中間接頭的線性高(gao)(gao)阻擊穿。

2、閃絡型擊穿點,擊穿后恒流源能維持電(dian)弧,有穩(wen)定電(dian)流通過電(dian)橋,電(dian)橋有足夠的靈敏(min)度。

3、電橋法僅僅要求線芯電阻的均勻性。因此,PVC聚氯乙(yi)烯絕緣(yuan)電纜(lan)(波特(te)性不好),沒有良導體回流的電纜(lan),超高(gao)壓電纜(lan)金屬護套缺陷點,僅有鋼(gang)鎧(kai)裝的電纜的故障定(ding)位(wei),只能用電橋(qiao)法定(ding)位(wei)。

4、尚(shang)未擊穿(chuan),但(dan)電阻偏低的(de)缺陷(xian)點(dian),如(ru)用(yong)兆歐表發現電纜阻值較低,但(dan)運行電壓下不擊穿(chuan)的(de)絕緣(yuan)缺陷(xian)點(dian)。

由于上(shang)述特(te)點高壓電(dian)纜(lan)故障定位(wei)電(dian)橋為下述幾類用戶所青睞:

1、從事(shi)專業(ye)定(ding)位的(de)電(dian)(dian)纜修試隊伍:如(ru)大(da)中型供電(dian)(dian)局及大(da)型用(yong)(yong)電(dian)(dian)企(qi)業(ye)的(de)電(dian)(dian)纜修試班。絕大(da)部分(fen)的(de)電(dian)(dian)纜擊(ji)(ji)穿點(dian)均可(ke)用(yong)(yong)高壓電(dian)(dian)纜故障定(ding)位電(dian)(dian)橋迅(xun)速找到大(da)致的(de)擊(ji)(ji)穿位置。與(yu)波反射法及定(ding)點(dian)儀(yi)配(pei)合使用(yong)(yong),各取所長,使定(ding)位更快更可(ke)靠(kao)。

2、小型(xing)用(yong)(yong)(yong)戶:如小型(xing)供電(dian)局及中型(xing)用(yong)(yong)(yong)電(dian)企業。電(dian)纜不(bu)(bu)多(duo),一(yi)般走向清楚(chu),不(bu)(bu)太長,故障次數有限,若(ruo)配齊一(yi)套波反射(she)法定位儀,價格高,對使用(yong)(yong)(yong)人員的素(su)質(zhi)和經驗要(yao)求較高,不(bu)(bu)是*佳選(xuan)擇(ze)。選(xuan)用(yong)(yong)(yong)高壓(ya)電(dian)纜故障定位電(dian)橋價格較低,操作方便,能應付日常(chang)需要(yao),是較好(hao)的選(xuan)擇(ze)。

3、電(dian)(dian)纜(lan)生產(chan)廠:在廠內(nei),可用(yong)作(zuo)各種線纜(lan)擊穿點的定(ding)(ding)位(wei)(wei),選(xuan)配數字電(dian)(dian)容表(biao),可找出斷線點。該設(she)備(bei)重量輕,便于攜帶至(zhi)現(xian)場為(wei)電(dian)(dian)纜(lan)用(yong)戶(hu)作(zuo)定(ding)(ding)位(wei)(wei)服務。

1.4技術指標

 直(zhi)流輸出      015kV

 短(duan)路電流      30mA

 定位比例(li)精度  0.2%L+1m

 重量(liang)     ;    10kg

 體積         38cm_36cm_27cm 

 工作電源      工頻(pin)220V       ?15

1.5供貨清單


2、WBST-600高壓(ya)電橋面板(ban)說明

1、接地(di)(di)柱:為儀器外殼(ke)及電(dian)橋(qiao)電(dian)氣**接地(di)(di)點,通(tong)過專(zhuan)用接地(di)(di)線與地(di)(di)相連,使用過程中務(wu)必可靠(kao)接地(di)(di),以確保(bao)人身**。

2、保險絲:5A5_20)。

3、電源插座:AC220V_15%

4、測量電纜首(shou)端:紅色測量夾頭(tou)。

5、測量(liang)電纜末端:黑(hei)色測量(liang)夾(jia)頭。

6、輸出電流表:單位mA

7、輸出電(dian)壓表:單位kV

8、電(dian)(dian)源指示:電(dian)(dian)源開關打開時,指示燈亮。否則(ze)應檢查電(dian)(dian)源和保險絲。

9、工(gong)作指示:電壓調節旋鈕逆(ni)時針旋轉(zhuan)到底,零位合閘后,指示燈亮,方可輸出高壓。

10、電源開關:左(zuo)為開,右為關。

11、電壓預(yu)置:顯(xian)示輸出電壓范圍(wei),同時選擇了顯(xian)示量(liang)程。

12、高壓調節(jie)(jie):高壓調節(jie)(jie)電(dian)位(wei)器帶(dai)零(ling)位(wei)開關(guan),逆時針(zhen)(zhen)調節(jie)(jie)到(dao)底能聽(ting)到(dao)咔嗒一聲,完成(cheng)零(ling)位(wei)合閘,順時針(zhen)(zhen)調節(jie)(jie)為(wei)升壓,逆時針(zhen)(zhen)調節(jie)(jie)為(wei)降壓。

13、檢(jian)流計:指(zhi)示平衡(heng)情況。

14、電池開關/靈敏度(du)調節旋鈕:有三(san)個用(yong)途:(1)檢流計(ji)電池的開關(guan)。(2)在“關”位(wei)置時,短(duan)路比例電(dian)位(wei)器,斷(duan)開檢流計,防止沖擊電(dian)流損壞(huai)電(dian)橋(qiao)。(3)調節(jie)(jie)檢流計靈(ling)敏度(du)。順(shun)時針旋轉,靈(ling)敏度(du)由 小到大。在(zai)調節(jie)(jie)過程中,應逐(zhu)步(bu)提高靈(ling)敏度(du),使指針偏轉對‰旋鈕的(de)微小調節(jie)(jie)敏感。

15、定位千分(fen)比(bi)調節:為電橋電阻(zu)調節旋(xuan)鈕,外圈數字對應為100‰,內圈對應為10‰、1‰。讀數P=外圈(quan)數字(zi)+內(nei)圈(quan)數字(zi),如圖2a)讀數應為720‰,圖2b)讀數應為315‰。

16、檢流計調零(ling):調節表(biao)頭電氣零(ling)位。內置放大器(qi)、連(lian)接線接觸電勢、熱電勢、空間電場都可能使指針偏離零(ling)位。應(ying)在連(lian)線完成(cheng),電源打開未(wei)升壓(ya)時(shi)調零(ling),可消除上(shang)述(shu)干擾。

17、更(geng)換(huan)電池:打開(kai)電池開(kai)關后(hou),若(ruo)調零時(shi)檢流計不動作,可能是電池電量不足(zu),應(ying)更(geng)換(huan)9V方塊電(dian)(dian)池。方法如下:先關閉電(dian)(dian)源,并對測量電(dian)(dian)纜可靠放電(dian)(dian),儀器(qi)側放,打開底部(bu)(bu)小(xiao)門,擰(ning)開高(gao)壓橋體下部(bu)(bu)的(de) 尼龍(long)蓋(gai),拉出電(dian)(dian)池,更換。應注意(yi),電(dian)(dian)橋工(gong)作時(shi)電(dian)(dian)池處于高(gao)電(dian)(dian)位(wei),因(yin)此(ci),換好(hao)(hao)的(de)電(dian)(dian)池及(ji)電(dian)(dian)池連接線 一定要(yao)放回原(yuan)位(wei),擰(ning)好(hao)(hao)尼龍(long)蓋(gai)。

3WBST-600高壓電(dian)橋(qiao)操作說明

3.1定位原理

利(li)用Murray電(dian)橋對(dui)擊穿點定(ding)位(wei)是經典的(de)辦法,方便而準確。電(dian)橋法的(de)依據是線芯(或屏蔽(bi)層)電(dian)阻均(jun) 勻,與長度(du)成比例(li)。下圖3為一典型用法。

鋼帶鎧裝三芯電(dian)力電(dian)纜,長度為(wei)LB相(xiang)線芯對鋼帶在L1處擊穿。借助于A相作為輔助線,使用低阻值連線短路(lu)NY 兩端。L     1段(duan)電纜線芯電阻為R1L2段電纜及A相(xiang)電(dian)纜線芯(xin)的電(dian)阻為R2。與定位電橋構成Murray電橋回(hui)路(lu)。其電路(lu)原理如圖(tu)4。 

比例(li)臂(bei)電阻與10圈刻度盤相(xiang)連,電阻比例P可(ke)由刻度盤讀(du)取,因此:

由此可見,只(zhi)要電(dian)橋有一定的靈敏度(du)并(bing)能平衡,電(dian)橋法定位簡單而**。

3.2測量步驟

故障線芯AB,輔助(zhu)線(xian)芯CD,線芯截面相同,長度均為L,測量端距(ju)離(li)故障點為Lx。 測量(liang)夾(jia)紅、黑夾(jia)子分別接至電(dian)纜線芯AC兩(liang)端,在遠端通過專用C型夾短(duan)路線短(duan)路DB兩端(duan)。

1、用(yong)萬(wan)用(yong)表(biao),搖表(biao)或其它耐壓設備確(que)認電纜擊穿狀態,記(ji)錄(lu)各芯的對地絕緣電阻或擊穿殘壓等(deng)數值。

2、記錄待(dai)測電纜(lan)(lan)長度、型號、截面等參數,沿電纜(lan)(lan)敷設(she)路(lu)徑巡視(shi),在遠端短(duan)路(lu)故障電纜(lan)(lan)及輔(fu)助(zhu)電纜(lan)(lan)出線端子(zi),留一人在遠端監(jian)護,以免高壓傷人。

3、接(jie)(jie)線。儀(yi)(yi)器接(jie)(jie)地(di)端可靠接(jie)(jie)至定位(wei)現場接(jie)(jie)地(di)體。測(ce)量首端(紅夾)接(jie)(jie)在(zai)故障電(dian)纜(lan)線芯(xin),首端電(dian)纜(lan)上金屬(shu)鱷(e)魚(yu)(yu)夾子跟(gen)儀(yi)(yi)器接(jie)(jie)地(di)端相連(lian),應(ying)與(yu)被測(ce)電(dian)纜(lan)鋼帶(dai)(或銅屏蔽(bi)(bi))可靠連(lian)接(jie)(jie),測(ce)量末端(黑夾)接(jie)(jie)輔 助(zhu)電(dian)纜(lan)線芯(xin)。接(jie)(jie)地(di)棒接(jie)(jie)在(zai)儀(yi)(yi)器接(jie)(jie)地(di)端。內置(zhi)的高壓(ya)源輸出“-”極性高壓(ya),通(tong)過比例電(dian)位(wei)器,經(jing)(jing)二 根測(ce)量電(dian)纜(lan),加在(zai)電(dian)纜(lan)線芯(xin)上,流(liu)過擊穿點,經(jing)(jing)鋼帶(dai)和金屬(shu)鱷(e)魚(yu)(yu)夾流(liu)入(ru)儀(yi)(yi)器接(jie)(jie)地(di)端。可見(jian),金屬(shu)鱷(e) 魚(yu)(yu)夾與(yu)鋼帶(dai)(或銅屏蔽(bi)(bi))可靠相連(lian)很重要,否則沒有(you)電(dian)流(liu)回路(lu),無(wu)法定位(wei)。 

4、電(dian)源接在AC220V。儀器內電(dian)源插座接地點(dian)懸(xuan)空,因此,不(bu)要求電(dian)源線可靠接地。

5、電(dian)(dian)橋(qiao)調零。電(dian)(dian)池(chi)開(kai)關置(zhi)“開(kai)”,旋(xuan)轉“調零”鈕(niu),(若指(zhi)針(zhen)偏左,順(shun)時(shi)針(zhen)旋(xuan)轉,指(zhi)針(zhen)偏右(you),逆(ni)時(shi)針(zhen)旋(xuan)轉)。使檢流(liu)計(ji)(ji)指(zhi)零。此后電(dian)(dian)池(chi)開(kai)關及時(shi)置(zhi)“關”。確認電(dian)(dian)池(chi)開(kai)關置(zhi)“關”!在(zai)“關”位(wei)置(zhi)時(shi),不但(dan)關 閉檢流(liu)計(ji)(ji)放大器電(dian)(dian)池(chi),同時(shi)短(duan)路比例(li)電(dian)(dian)位(wei)器,斷開(kai)檢流(liu)計(ji)(ji)。可(ke)避免(mian)升壓燃弧階(jie)段的(de)脈沖電(dian)(dian)流(liu)損壞電(dian)(dian) 橋(qiao)。因此,在(zai)電(dian)(dian)流(liu)穩定前,電(dian)(dian)池(chi)開(kai)關必須處(chu)于(yu)“關”位(wei)置(zhi)。

6、選擇適當的電(dian)壓范圍。對于低電(dian)壓電(dian)纜,選“5kV”檔,可防止誤操作使電壓(ya)過高。

7、升壓(ya)。打開“電(dian)源開關”,電(dian)源指(zhi)示(shi)燈(deng)(deng)亮。“高壓(ya)調節”鈕逆時針到(dao)底,零位啟動(dong),工作指(zhi)示(shi)燈(deng)(deng)亮。

8、順時針緩慢(man)旋轉“高壓調節”鈕,觀察(cha)電壓表及電流(liu)表,直到電流(liu)表超(chao)過10mA。若電(dian)流不穩(wen)定,可繼續升高電(dian)壓,保持一段(duan)時間(jian),形成穩(wen)定電(dian)弧(hu)或(huo)導電(dian)區,使(shi)測試過程的(de)電(dian)流穩(wen)定。

9、平衡(heng)調節。順時針(zhen)旋(xuan)轉(zhuan)“電池開關/靈(ling)敏(min)度(du)”鈕,逐檔增大靈(ling)敏(min)度(du),至檢流計(ji)有明顯偏轉(zhuan)但(dan)不過度(du),旋轉(zhuan)“‰”刻度(du)盤,使(shi)檢流計(ji)指零(ling)(若指針(zhen)偏左,順時針(zhen)旋轉(zhuan),指針(zhen)偏右,逆時針(zhen)旋轉(zhuan))。逐檔提高(gao) 靈(ling)敏(min)度(du),使(shi)指針(zhen)偏轉(zhuan)對(dui)“‰”旋鈕的(de)微小(xiao)調節敏(min)感(gan)即可。

10、記下此時“‰”刻度盤的讀數(shu)P1‰,應有P1500

11、降電(dian)壓,關(guan)閉“電(dian)源開關(guan)”,放電(dian),并經另(ling)一(yi)人確認。將測量(liang)鉗(qian)交(jiao)換位置,(回流接地C形(xing)夾不必更(geng)換位置(zhi))。重復步(bu)驟(zou)(4)至(10)得到另一讀(du)數(shu)P2,應(ying)有P1+P2=1000。該過程能避免讀數及測量鉗使用上的(de)錯誤,P1+P2不必追求完全等于1000。在9901010之間均屬(shu)正(zheng)常。在高壓(ya)合閘,無電流輸出,當(dang)前靈(ling)敏度檔重復調零(ling)能(neng)得到更為準確的比(bi)例。

12、計算故障點(dian)的位置

Lx = 2 _ L _ P1

應特別注意公式中(zhong)的“2”,因(yin)為輔(fu)助(zhu)電(dian)纜使參與計算的(de)電(dian)纜延長了一倍(bei)。

4WBST-600高(gao)壓(ya)電(dian)橋使用經驗

4.1測(ce)量(liang)鉗的正(zheng)確使用(yong)

在預(yu)定位故障點時,測量鉗的紅(hong)黑夾(jia)子分別接(jie)至比(bi)例電(dian)位器及檢流計,相(xiang)當于雙(shuang)臂電(dian)橋的PC端(duan),顯然 不(bu)能直接短路(lu),鋁芯表面(mian)有氧(yang)化層,應砂光處理。

4.2使用該(gai)設備完成(cheng)耐壓試(shi)驗(yan)

該設備可(ke)以用于(yu)耐壓(ya)試驗(yan),與(yu)一般耐壓(ya)設備不(bu)(bu)同(tong),它不(bu)(bu)能過(guo)流(liu)跳閘,應觀察電(dian)壓(ya)及電(dian)流(liu)表(biao)的讀(du)數判斷絕 緣狀況。接(jie)線(xian)應注(zhu)意:兩個測量鉗(qian)同(tong)時(shi)輸出高壓(ya),應同(tong)時(shi)接(jie)至電(dian)纜線(xian)芯,金屬屏蔽或(huo)其它線(xian)芯接(jie)儀器(qi)地(di)。

4.3如何使電流(liu)穩(wen)定

電(dian)(dian)(dian)橋在穩定(ding)電(dian)(dian)(dian)流(liu)(liu)(liu)下(xia)才能平衡。升(sheng)壓(ya)(ya)前,靈敏度檔應位于“關”位置,短(duan)路電(dian)(dian)(dian)橋,防止沖(chong)擊(ji)電(dian)(dian)(dian)流(liu)(liu)(liu)損(sun)壞(huai)檢(jian)流(liu)(liu)(liu) 計放大板(ban)。開始升(sheng)壓(ya)(ya)時,高阻擊(ji)穿點往往有爬電(dian)(dian)(dian),使(shi)電(dian)(dian)(dian)流(liu)(liu)(liu)波動,保持*大電(dian)(dian)(dian)流(liu)(liu)(liu)幾分(fen)鐘(zhong),電(dian)(dian)(dian)流(liu)(liu)(liu)將趨(qu)于穩定(ding)。 某(mou)些閃絡型故障,需(xu)要更(geng)長(chang)時間,故障點經頻頻放電(dian)(dian)(dian),形成電(dian)(dian)(dian)弧后,電(dian)(dian)(dian)流(liu)(liu)(liu)達到穩定(ding)。使(shi)用脈(mo)沖(chong)源和定(ding)位 電(dian)(dian)(dian)橋同時加壓(ya)(ya),可提高燒(shao)穿功(gong)率,縮短(duan)電(dian)(dian)(dian)流(liu)(liu)(liu)穩定(ding)時間。

4.4電橋(qiao)的靈敏度(du)選擇

充分理解(jie)影(ying)響靈敏度(du)的因素(su)對(dui)測試有幫助:

1、通(tong)過電橋的電流(liu)越(yue)大(da),靈敏度越(yue)高。

2、電(dian)(dian)纜導體電(dian)(dian)阻(zu)越大(da),電(dian)(dian)橋獲得的靈敏(min)度越高,即細而(er)長的電(dian)(dian)纜靈敏(min)度較(jiao)(jiao)高,粗(cu)而(er)短的電(dian)(dian)纜靈敏(min)度較(jiao)(jiao) 低。對于截面大(da),長度短的電(dian)(dian)纜,應盡可(ke)能增大(da)電(dian)(dian)流,選用較(jiao)(jiao)高的靈敏(min)度檔位。

3、對于(yu)相間擊穿的定位,選擇截面較小(xiao)的線芯為橋臂,靈(ling)敏度較高(gao)。

4.5輔(fu)助(zhu)線芯(xin)截面不同時(shi)的換算

可以采用(yong)不同截(jie)面的線芯(xin)作為(wei)輔(fu)助電纜,計算(suan)(suan)時,應將輔(fu)助電纜折算(suan)(suan)至故(gu)障電纜的長(chang)度。如故(gu)障截(jie)面為(wei) Sx,輔助電纜(lan)為S,則(ze)上述公式變為:

X = P1‰×(1+Sx/S)×L

可以直觀理解為:輔(fu)助電(dian)纜愈(yu)細(xi),電(dian)阻愈(yu)大,相(xiang)當于更長(chang)的故(gu)障(zhang)電(dian)纜。

 4.6成盤電纜的定(ding)位

高壓電(dian)(dian)纜(lan)(lan)故(gu)障定(ding)位(wei)電(dian)(dian)橋為敷(fu)設(she)現場(chang)定(ding)位(wei)而設(she)計,當然也可(ke)以用于出廠試驗中的缺陷點(dian)定(ding)位(wei)。區別(bie)是測量鉗夾在電(dian)(dian)纜(lan)(lan)的兩端,不必使用低阻短路線,沒有輔助(zhu)電(dian)(dian)纜(lan)(lan)參與平衡(heng),計算公式不能(neng)有“2”, 如下:

X = L× P1

4.7銅(tong)帶(dai),鋼帶(dai)能作為橋臂(bei)嗎(ma)

電橋定位的精度(du)有賴(lai)于導(dao)體電阻均勻,電纜廠不一定焊接銅(tong)帶(dai)(dai)(dai)、鋼帶(dai)(dai)(dai)搭接頭。銅(tong)帶(dai)(dai)(dai)接觸電阻小,對定位 精度(du)影響很(hen)小。鋼帶(dai)(dai)(dai)應(ying)小心(xin),可能會(hui)引入較(jiao)大誤差,應(ying)該心(xin)中有數(shu),盡量避免利用鋼帶(dai)(dai)(dai)定位。

4.8架空(kong)電纜的(de)定(ding)位

架空電纜(lan)通常為(wei)單(dan)芯,僅有(you)絕緣層,浸(jin)水(shui)耐壓試驗發現的(de)缺陷點(dian)同樣可以定位(wei),與其它成盤電纜(lan)**不 同在于,接地(di)極(ji)為(wei)水(shui)。可將儀器(qi)地(di)接至(zhi)水(shui)池的(de)接地(di)點(dian),或(huo)用銅帶放在水(shui)中,作為(wei)接地(di)極(ji)。

4.9多點缺陷點定位

這(zhe)里(li),有必要區(qu)分(fen)缺陷點(dian)(dian)(dian)是低阻點(dian)(dian)(dian)還是擊(ji)(ji)(ji)穿(chuan)點(dian)(dian)(dian)。理論(lun)上,定位(wei)(wei)(wei)比例指向多(duo)(duo)個(ge)漏電(dian)流(liu)(liu)構成的(de)(de)重心,因此電(dian) 橋(qiao)法不能定位(wei)(wei)(wei)多(duo)(duo)個(ge)故障點(dian)(dian)(dian)。運行電(dian)纜上,故障過電(dian)壓(ya)(ya)(ya)浪(lang)涌偶(ou)爾(er)能造成電(dian)纜多(duo)(duo)處(chu)弱點(dian)(dian)(dian)依次擊(ji)(ji)(ji)穿(chuan),導致(zhi)多(duo)(duo)點(dian)(dian)(dian) 擊(ji)(ji)(ji)穿(chuan)。但多(duo)(duo)個(ge)擊(ji)(ji)(ji)穿(chuan)點(dian)(dian)(dian)情(qing)況很難(nan)一致(zhi),隨著直流(liu)(liu)電(dian)壓(ya)(ya)(ya)上升,*弱的(de)(de)點(dian)(dian)(dian)先(xian)擊(ji)(ji)(ji)穿(chuan),流(liu)(liu)過絕(jue)大多(duo)(duo)數電(dian)流(liu)(liu),根據比 例計(ji)算的(de)(de)位(wei)(wei)(wei)置十分(fen)靠(kao)近該(gai)點(dian)(dian)(dian)。剔除該(gai)點(dian)(dian)(dian),再找下(xia)一點(dian)(dian)(dian)。實際中(zhong)碰到兩個(ge)以上點(dian)(dian)(dian)同時流(liu)(liu)過較大電(dian)流(liu)(liu)的(de)(de)機(ji)會 很少,可以說,碰到多(duo)(duo)點(dian)(dian)(dian)擊(ji)(ji)(ji)穿(chuan)導致(zhi)定位(wei)(wei)(wei)不準的(de)(de)幾率,比中(zhong)大獎(jiang)更小,因此,不必擔(dan)心電(dian)橋(qiao)難(nan)以定位(wei)(wei)(wei)多(duo)(duo)點(dian)(dian)(dian) 擊(ji)(ji)(ji)穿(chuan)。沒(mei)有擊(ji)(ji)(ji)穿(chuan)的(de)(de)低阻點(dian)(dian)(dian),隨電(dian)壓(ya)(ya)(ya)升高,大部分(fen)轉化為擊(ji)(ji)(ji)穿(chuan)點(dian)(dian)(dian)。特(te)殊的(de)(de)低阻點(dian)(dian)(dian),如成批材料絕(jue)緣(yuan)**, 定位(wei)(wei)(wei)比例總是在 50%左右(you),值(zhi)得警惕。

4.10相間擊(ji)穿定位(wei)

與(yu)(yu)前文例子的(de)(de)區別僅僅為(wei),電流應通過另(ling)一線芯流回(hui)電橋,因此,相間(jian)擊穿(chuan)的(de)(de)另(ling)一線芯應接至電橋地。 實際(ji)中可能(neng)是:相間(jian)擊穿(chuan)及(ji)相與(yu)(yu)屏(ping)蔽擊穿(chuan)共存,不妨(fang)將(jiang)其它線芯及(ji)屏(ping)蔽都接地,結果(guo)大多為(wei):相間(jian)擊穿(chuan) 及(ji)相與(yu)(yu)屏(ping)蔽擊穿(chuan)是同一點。                                        

4.11無(wu)良(liang)好絕緣輔助線(xian)芯(xin)的處理

4.10條中類(lei)似(si),可能(neng)所有相間及屏(ping)蔽都擊穿了(le),找不(bu)(bu)(bu)到輔助電(dian)纜(lan)相。方(fang)法是:用(yong)萬用(yong)表挑一相絕緣電(dian) 阻較(jiao)大(da)的(de)為輔助電(dian)纜(lan),道理與多(duo)點擊穿類(lei)似(si),不(bu)(bu)(bu)難想通。如都燒成一體,為金屬性短路,只(zhi)能(neng)利(li)用(yong)平行 敷設(she)的(de)其它電(dian)纜(lan)了(le),還不(bu)(bu)(bu)行,只(zhi)能(neng)放臨(lin)時輔助電(dian)纜(lan)。考(kao)慮(lv)到該套儀(yi)器中其它方(fang)法可用(yong),*終束手(shou)無策(ce)的(de) 機(ji)會并不(bu)(bu)(bu)多(duo) ,從提(ti)高定 位(wei)技(ji)術的角(jiao)度講,我們很希望碰到定不出來的故(gu)障,可(ke)惜(xi)至今(jin)還沒有(you)這樣的挑戰。

4.12單芯電纜絕(jue)緣缺陷點定(ding)位

單芯電纜通常為35kV及以上(shang)的(de)高壓電纜(lan),定(ding)位接線如下圖6

與(yu)多芯電纜*大的不同是,外界(jie)干擾影(ying)響(xiang)電橋(qiao)平衡(heng)的可能性(xing)加大,短接MXNY點的金屬護(hu)套(tao)很(hen)有 效(xiao),參(can)考第4.14條。高壓電(dian)纜間距較大(da),應選(xuan)配(pei)大(da)長度短接線。

4.13高壓(ya)電(dian)纜護套缺陷(xian)點定位

高壓電(dian)(dian)纜(lan)(lan)外護套故障(zhang)測距儀是定(ding)位電(dian)(dian)纜(lan)(lan)護套缺陷點*有(you)效的(de)方法,接線如圖(tu)7。詳細內容(rong)請參考本公司(si)的 相關資料。

4.14 干(gan)擾(rao)類(lei)型及排除方法

對大截面(mian)電(dian)(dian)(dian)纜(lan)(lan)(lan)(lan)**定(ding)位(wei),需要高(gao)(gao)靈(ling)敏度的(de)(de)檢(jian)流計(ji),本儀器(qi)消除了高(gao)(gao)壓源對電(dian)(dian)(dian)橋檢(jian)流計(ji)的(de)(de)干(gan)(gan)擾(rao)(rao),大大衰減 了外界干(gan)(gan)擾(rao)(rao)訊信(xin)號。但仍可(ke)能有一(yi)些干(gan)(gan)擾(rao)(rao)影響電(dian)(dian)(dian)橋平(ping)衡。單芯電(dian)(dian)(dian)纜(lan)(lan)(lan)(lan)定(ding)位(wei)的(de)(de)工頻(pin)干(gan)(gan)擾(rao)(rao)。故(gu)障電(dian)(dian)(dian)纜(lan)(lan)(lan)(lan)附近(jin),通常(chang)有其它(ta)線(xian)路在運行(xing),流過(guo)工頻(pin)大電(dian)(dian)(dian)流。故(gu)障電(dian)(dian)(dian)纜(lan)(lan)(lan)(lan)芯與輔 助(zhu)電(dian)(dian)(dian)纜(lan)(lan)(lan)(lan)包含的(de)(de)面(mian)積(ji)愈大,磁場感應(ying)干(gan)(gan)擾(rao)(rao)也愈大。多芯電(dian)(dian)(dian)纜(lan)(lan)(lan)(lan)由于包含的(de)(de)面(mian)積(ji)小,加上金屬(shu)護層的(de)(de)屏蔽(bi)作(zuo)用, 不影響平(ping)衡。但是定(ding)位(wei)高(gao)(gao)壓電(dian)(dian)(dian)纜(lan)(lan)(lan)(lan),可(ke)能干(gan)(gan)擾(rao)(rao)太大,無法(fa)平(ping)衡。以高(gao)(gao)壓電(dian)(dian)(dian)纜(lan)(lan)(lan)(lan)護套(tao)缺陷點定(ding)位(wei)為例(li),改(gai)善方(fang) 法(fa)為:將(jiang)故(gu)障相(xiang)及輔助(zhu)相(xiang)的(de)(de)線(xian)芯兩(liang)端(duan)接(jie)地,或在兩(liang)端(duan)將(jiang)線(xian)芯彼此短接(jie),形成(cheng)反相(xiang)磁場,效果(guo)明顯。

4.15斷(duan)芯電纜定位

不能(neng)定位斷芯故障是(shi)高壓電(dian)橋法*大(da)的不足。好(hao)在完(wan)全的斷路在電(dian)力電(dian)纜中不多見,完(wan)全斷路可以選配 數字電(dian)容表(biao)解決,方(fang)法見第4.16條。斷(duan)線故障(zhang)定位*好用HDTDR波反(fan)射法定(ding)(ding)(ding)位儀。 運(yun)行(xing)故障中,大電流燒熔線(xian)芯(xin)(xin)及金屬(shu)屏蔽層(ceng),斷芯(xin)(xin)不(bu)完全,往(wang)往(wang)伴隨著(zhu)短路,電橋法可以定(ding)(ding)(ding)位。小截面(mian) 鋁芯(xin)(xin)電纜,制造中已部分拉斷線(xian)芯(xin)(xin),但內半導電層(ceng)還貫通(tong),半導電層(ceng)作為電橋電阻的(de)一部分,使定(ding)(ding)(ding)位比(bi) 例不(bu)正確。定(ding)(ding)(ding)位比(bi)例接近0‰或999‰。

用萬用表測量線芯(xin)電阻,可以判(pan)斷是否為(wei)斷芯(xin)故(gu)障。斷芯(xin)時(shi),定位比例不正確(que)。波反射法是更(geng)好(hao)的方法。 繞包的銅帶(dai)或(huo)鋼帶(dai)不易斷路,可嘗試用金屬屏蔽(bi)作為(wei)橋臂定位。

5WBST-600高壓電(dian)橋簡(jian)單異常情況(kuang)及(ji)處(chu)理

1若換好電池后檢流(liu)計(ji)仍不能(neng)調零,可能(neng)放(fang)大模塊損(sun)壞,應更換放(fang)大模塊。

2調不到零(ling)位(wei),可能(neng)的(de)情(qing)況為:

■遠端沒(mei)有(you)短路或夾(jia)錯了電纜。

■夾(jia)頭(tou)接(jie)觸(chu)不(bu)好(hao)。一個(ge)夾(jia)子的兩個(ge)鉗(qian)口分別引(yin)入電流及電位信號,任何一側接(jie)觸(chu)不(bu)好(hao),都會影響平(ping)衡,表(biao)現為電位器(qi)旋至起(qi)點(dian)或終點(dian)時(shi)偏(pian)轉*小,但(dan)無法平(ping)衡。檢查電橋測試夾(jia),若出線桿接(jie) 觸(chu)**應(ying)磨掉出線桿氧化層(ceng)。

■測量(liang)電(dian)纜斷路,應(ying)維修。

■靈敏(min)度太高,不(bu)易(yi)找到平(ping)衡點(dian),應(ying)根(gen)據(ju)需要調節靈敏(min)度檔級,盡量使(shi)檢(jian)流(liu)計指針在_25格內(nei)。

■故障在終端內。此時能(neng)平衡的比例應為(wei)小于(yu)1‰或(huo)大于999‰,已超出了比例電位器的(de)范圍,平(ping)衡過程中表現為:比例至1‰或999‰時,指針趨于零位(wei)(wei),但不能平(ping)衡(heng)。交換測(ce)量鉗,比(bi)例電位(wei)(wei) 器調至另一端(duan)時,指針趨于零位(wei)(wei),仍不能平(ping)衡(heng)。線(xian)芯(xin)在故障點(dian)處(chu)斷線(xian)時,也(ye)有類(lei)似表(biao)現:因為 斷線(xian)點(dian)電阻比(bi)線(xian)芯(xin)高很多,形成電橋平(ping)衡(heng)點(dian)在端(duan)部的表(biao)象(xiang)。

3若測量(liang)中(zhong)懷疑(yi)電(dian)橋(qiao)有誤差,可通過隨(sui)機所配(pei)電(dian)橋(qiao)檢(jian)驗(yan)模(mo)塊(kuai)來檢(jian)驗(yan)電(dian)橋(qiao)本(ben)身的精度。

如圖8,電橋紅、黑夾子及地(或接地夾)按圖上標識(shi)接線(xian),儀器本(ben)身必須可靠接地,檢驗模(mo)塊有兩 條線(xian)路,上面一條為*低(di)靈敏度1擋條(tiao)件(jian)下測量線路,電橋(qiao)顯示(shi)讀數應該為33.3%;下面一條(tiao)為*高 靈敏度5檔條件下測量線(xian)路,電橋(qiao)顯(xian)示讀數(shu)應和測試盒面板示數(shu)一致;若檢(jian)驗發(fa)現無明顯(xian)偏差,說(shuo)明 電橋(qiao)本身沒問(wen)題。

產品留言
標題(ti)
聯系人(ren)
聯系電話
內容
驗證碼
點擊換一張
注:1.可以使用快捷鍵Alt+S或Ctrl+Enter發送信息!
2.如有必要,請您留下您的詳細聯系方式!
產品目錄
Copyright? 2003-2024 揚州萬寶電(dian)力設(she)備有限公司版權所有    地址:江(jiang)蘇省揚(yang)州寶應(ying)柳堡工業(ye)園萬(wan)寶路1號    郵編(bian):225828
電話:0514-88771393 0514-88778599     傳真:0514-88771019   

多功能微機繼電保護測試儀,多功能型鉗形接地電阻儀,手持全自動變比測試儀,發電機水內冷直流高壓發生器,無線高壓變比測試儀,漏電流監控記錄儀,三相相序表,非接觸型檢相器