電(dian)力設(she)備(bei)(bei)的(de)接地(di)引下(xia)線(xian)與地(di)網(wang)的(de)可(ke)(ke)(ke)靠、有(you)(you)效連(lian)接是設(she)備(bei)(bei)**運(yun)(yun)行(xing)的(de)根本保障。接地(di)引下(xia)線(xian)是電(dian)力設(she)備(bei)(bei)與地(di)網(wang)的(de)連(lian)接部(bu)分,在電(dian)力設(she)備(bei)(bei)的(de)長(chang)時(shi)間(jian)運(yun)(yun)行(xing)過程中,連(lian)接處有(you)(you)可(ke)(ke)(ke)能(neng)(neng)因受(shou)潮等因素影(ying)響,出現節(jie)點(dian)(dian)銹蝕、甚至(zhi)斷裂等現象,導(dao)致(zhi)接地(di)引下(xia)線(xian)與主接地(di)網(wang)連(lian)接點(dian)(dian)電(dian)阻增大(da),從而不(bu)能(neng)(neng)滿足電(dian)力規程的(de)要求,使設(she)備(bei)(bei)在運(yun)(yun)行(xing)中存在不(bu)**隱患,嚴(yan)重時(shi)會造(zao)成設(she)備(bei)(bei)失地(di)運(yun)(yun)行(xing)。我(wo)公司利用(yong)自(zi)身技術優勢研制了系列接地(di)引下(xia)線(xian)導(dao)通測試(shi)儀。該(gai)儀器(qi)采用(yong)全新(xin)電(dian)源技術,具有(you)(you)體(ti)積(ji)小、重量輕、輸出電(dian)流大(da)并且可(ke)(ke)(ke)根據負載大(da)小自(zi)動(dong)(dong)調(diao)整(zheng)等特(te)點(dian)(dian)。整(zheng)機由單(dan)片機控制,自(zi)動(dong)(dong)完成自(zi)檢、數據處理(li)、顯(xian)示、打印等功(gong)(gong)能(neng)(neng),具有(you)(you)自(zi)動(dong)(dong)放電(dian)和放電(dian)指示功(gong)(gong)能(neng)(neng)。儀器(qi)測試(shi)精度(du)高,操(cao)作簡(jian)便(bian),可(ke)(ke)(ke)實(shi)現接地(di)電(dian)阻的(de)快速測量。
一、WBDT-V接地線導通電阻分析儀**措施
使用本儀器(qi)前(qian)一定要(yao)認真閱(yue)讀本手冊。
儀(yi)器(qi)的操作(zuo)者應具(ju)備一般電氣設備或儀(yi)器(qi)的使(shi)用常識。
本儀器戶(hu)內外均可使用,但(dan)應避(bi)開雨淋、腐(fu)蝕氣(qi)體(ti)、塵(chen)埃過濃、高(gao)溫(wen)、陽光直射等(deng)場所。
儀表應避免劇(ju)烈振動。
對儀器(qi)的(de)維修、護理(li)和調整應(ying)由專業人員(yuan)進行(xing)。
測試(shi)完畢(bi)后一定要等放(fang)電報警聲停止后再關閉(bi)電源,拆除測試(shi)線。
在測(ce)試(shi)過程中,禁止(zhi)移動測(ce)試(shi)夾(jia)和(he)供電(dian)線路。
二、WBDT-V接地線導通電阻分析儀性能特點
儀器輸出電流(liu)大,測量范圍寬,操作簡便;
儀(yi)器具有完善的反電勢(shi)保(bao)護功能,音響放電報警,放電指示清晰,減少誤操作;
儀(yi)器(qi)裝(zhuang)有(you)打(da)印(yin)機,可隨時打(da)印(yin)測(ce)試數據;
儀器具有實時時鐘,并可連同測試記錄一起保存、打印,方(fang)便用戶保存、查閱;
儀器(qi)內(nei)部可(ke)以長久存儲測試(shi)數據(ju)200條(可擴(kuo)展),還(huan)可以使用優盤存儲(chu)數據方便(bian)用戶導(dao)入(ru)電腦處理(li)。
儀(yi)器(qi)具有適用溫度寬(kuan),精度高,防震(zhen),抗干(gan)擾,體積小(xiao),重量輕,攜帶方(fang)便(bian)等(deng)特點。
三、WBDT-V接地線導通電阻分析儀技術指標
測(ce)試電流(liu):0.2A、1A、5A、10A四檔
測試(shi)范圍(wei):0.2 A 10 Ω ~ 100Ω
1 A 100mΩ ~ 20 Ω
5 A 10 mΩ ~ 4 Ω
10 A 1 mΩ ~ 2 Ω
準確度:±(讀數×0.2%+2字)
*高(gao)分辨率: 0.1μΩ
工(gong)作溫(wen)度(du):-5~40℃;環境濕度:≤90%RH,無結(jie)露
工作電源:AC220V±10%,50HZ±1HZ
體積:390×280×200mm
重量:7Kg(不包(bao)括測試線)
四、WBDT-V接地線導通電阻分析儀面板功能介紹(shao)
儀器面板見圖一(yi)。
電(dian)源開關(guan):整機電(dian)源輸入口,帶有交流插座(zuo),保險倉和開關(guan)。
: 接(jie)地柱,為整機外殼接(jie)地用,屬(shu)保(bao)護地。
V+、V-: 電壓(ya)輸入端子。
I+、I-: 電流輸出(chu)端子。
顯示器: 128×64點(dian)陣(zhen)液晶顯(xian)示器(qi),人機交互界面。
打印機: 打印輸(shu)出直流電阻測(ce)試(shi)結果。
USB: 優(you)盤接口
RS232: 儀器與計(ji)算機連接的通(tong)訊接口
返(fan)回鍵: 返回上級菜單界面(mian)或取消(xiao)當前操作。
選(xuan)擇鍵: 在(zai)儀器操作過程中移(yi)動光標。
確認鍵: 修改參(can)數(shu)或(huo)執行所選操作。
五(wu)、WBDT-V接地線導通電阻分析儀使用說明
1、儀器(qi)開機顯(xian)示畫面
打開(kai)電源開(kai)關(guan)(開(kai)關(guan)上I為開(kai),O為關(guan)),儀器顯(xian)示區將顯(xian)示圖三界(jie)面。
2、時鐘界面
放(fang)電(dian)檢測完畢后,儀器自動進入(ru)時鐘界面。
此(ci)界面(mian)(mian)實時顯示(shi)系統時鐘(zhong)(zhong)(zhong)(zhong),用戶可按(an)(an)“確認(ren)”鍵(jian)(jian)直(zhi)接進(jin)入(ru)主(zhu)菜(cai)單界面(mian)(mian)。如(ru)用戶想(xiang)(xiang)修改時鐘(zhong)(zhong)(zhong)(zhong),可按(an)(an)選擇鍵(jian)(jian)移(yi)動(dong)光(guang)標(字體反(fan)白(bai)顯示(shi)為光(guang)標選中狀態),此(ci)時按(an)(an)“確認(ren)”鍵(jian)(jian)可實現數(shu)值加一(yi)功能,當光(guang)標移(yi)動(dong)到(dao)“確定”按(an)(an)鈕時,按(an)(an)“確認(ren)”鍵(jian)(jian)即(ji)可設定時鐘(zhong)(zhong)(zhong)(zhong)并進(jin)入(ru)主(zhu)菜(cai)單界面(mian)(mian),如(ru)中途用戶不想(xiang)(xiang)修改時鐘(zhong)(zhong)(zhong)(zhong)了,可按(an)(an)“返回”鍵(jian)(jian)推出(chu)設定界面(mian)(mian),儀器仍將實時刷新時鐘(zhong)(zhong)(zhong)(zhong),再(zai)按(an)(an)“確認(ren)”鍵(jian)(jian)即(ji)可進(jin)入(ru)主(zhu)菜(cai)單界面(mian)(mian)。
3、主菜(cai)單界面(mian)
按“選擇”鍵移(yi)動光標,按“確認”鍵進入所選菜單(dan),按“返回”鍵回到上(shang)一頁。
3.1導通測試菜(cai)單
按(an)“選(xuan)擇(ze)”移動光(guang)標(biao)(biao),當(dang)光(guang)標(biao)(biao)選(xuan)中“電(dian)流(liu)選(xuan)擇(ze):xxxA”時,按“確認(ren)”可修改電流值(zhi)(0.2A→1A→5A→10A→0.2A循環顯(xian)示);當光標移動到“確(que)定(ding)”按鈕時,按確(que)認鍵(jian)即(ji)可按當前選定(ding)的測(ce)試(shi)電(dian)流進(jin)行測(ce)試(shi),進(jin)入圖(tu)(tu)七→圖(tu)(tu)八→圖(tu)(tu)九(jiu)界面(mian)。
當進度條到達右端,表(biao)示(shi)測試完畢,將顯示(shi)測試結(jie)果如圖十
此時界(jie)面顯示的電阻(zu)值為實(shi)時測量值,用戶可(ke)按(an)“選(xuan)擇(ze)”鍵(jian)(jian)選(xuan)擇(ze)“保(bao)存(cun)”或是“打印”,按(an)“確(que)認(ren)”鍵(jian)(jian)執行所(suo)選(xuan)操作(zuo),按(an)“返回(hui)”鍵(jian)(jian)儀(yi)器停止測試(shi)并開始(shi)放電如圖十一
放電完(wan)畢后,儀器(qi)將返回到(dao)圖六界(jie)面。
當在圖十界面(mian)中用戶選(xuan)擇保存(cun)時,儀(yi)器將提(ti)示用戶選(xuan)擇存(cun)儲介質如(ru)圖十二(er)
按(an)“選(xuan)擇(ze)”鍵移動(dong)光(guang)標(biao),按(an)“確認”鍵保存到(dao)相(xiang)應存儲介質并(bing)返(fan)回到(dao)圖十(shi)界(jie)面,實時(shi)刷新測量結果,也可(ke)不保存按(an)“返(fan)回”回到(dao)圖十(shi)界(jie)面,實時(shi)刷新測量結果。
注:整個(ge)測試過程中(zhong)切勿拆線(xian),待放電(dian)完畢(bi)方可(ke)拆線(xian)。
3.2、數據存取菜單
按“選擇(ze)”鍵(jian)(jian)移(yi)動光標,按“確認(ren)”鍵(jian)(jian)執行(xing)所選操作,按“返回(hui)”鍵(jian)(jian)回(hui)到主菜單。
六(liu)、注意(yi)事(shi)項
測試(shi)過程(cheng)中嚴(yan)禁拆除測試(shi)下和(he)切斷(duan)系(xi)統電源。
在(zai)拆線前,一定要等(deng)放電結束后,報警聲停止,再進行拆線。
如(ru)果測試線(xian)沒(mei)接好(hao),儀(yi)器會自動提(ti)示“電(dian)源開路”。這時須(xu)檢查線(xian)路是否有正確或(huo)沒(mei)接牢固,然(ran)后按復位鍵重新測量。
七(qi)、售后服務
1、凡購(gou)本公(gong)司產(chan)品(pin)隨機攜帶產(chan)品(pin)保修(xiu)單(dan),訂購(gou)產(chan)品(pin)交(jiao)貨時,請(qing)當(dang)場檢驗并(bing)填(tian)好保修(xiu)單(dan)。
2、自購機之日(ri)起(qi),憑保修(xiu)單保修(xiu)二年,終(zhong)身維護。在保修(xiu)期內,維修(xiu)不收維修(xiu)費;保修(xiu)期外,維修(xiu)調試收取適當費用(yong)。
3、屬下列情況之一者不予保修(xiu):
1)用(yong)戶對(dui)儀器(qi)有(you)自行拆卸或對(dui)儀器(qi)工藝結構有(you)人為改變(bian)。
2)因用(yong)戶保管(guan)或使用(yong)不當(dang)造成(cheng)儀(yi)器的嚴重損壞。
3)屬于用戶其它原因造成的(de)損壞。
裝箱(xiang)單(dan)
儀器名稱:接(jie)地(di)引下線(xian)導通測(ce)試儀
測試儀主機
|
一(yi)臺(tai)
|
測試線
|
二條(tiao)(紅黑)
|
三芯電源線
|
一(yi)條
|
接地線
|
一(yi)條
|
保險管(3A)
|
三支
|
打(da)印紙
|
二卷
|
測試報告(gao)
|
一份(fen)
|
裝箱單
|
一張
|
使用說明(ming)書
|
一本
|
合(he)格證 保修(xiu)卡
|