電(dian)(dian)(dian)(dian)(dian)力(li)設(she)備的(de)(de)接(jie)(jie)(jie)(jie)地(di)引(yin)下線與(yu)地(di)網的(de)(de)可(ke)靠、有效連(lian)接(jie)(jie)(jie)(jie)是設(she)備**運行(xing)(xing)(xing)的(de)(de)根本保(bao)障(zhang)。接(jie)(jie)(jie)(jie)地(di)引(yin)下線是電(dian)(dian)(dian)(dian)(dian)力(li)設(she)備與(yu)地(di)網的(de)(de)連(lian)接(jie)(jie)(jie)(jie)部分(fen),在(zai)電(dian)(dian)(dian)(dian)(dian)力(li)設(she)備的(de)(de)長時(shi)間運行(xing)(xing)(xing)過(guo)程中,連(lian)接(jie)(jie)(jie)(jie)處(chu)有可(ke)能因(yin)受潮等(deng)因(yin)素(su)影響(xiang),出(chu)現節(jie)點(dian)銹蝕、甚(shen)至斷(duan)裂等(deng)現象,導致接(jie)(jie)(jie)(jie)地(di)引(yin)下線與(yu)主接(jie)(jie)(jie)(jie)地(di)網連(lian)接(jie)(jie)(jie)(jie)點(dian)電(dian)(dian)(dian)(dian)(dian)阻增大(da)(da),從而不能滿(man)足電(dian)(dian)(dian)(dian)(dian)力(li)規(gui)程的(de)(de)要求,使設(she)備在(zai)運行(xing)(xing)(xing)中存在(zai)不**隱患,嚴(yan)重(zhong)(zhong)時(shi)會造成設(she)備失地(di)運行(xing)(xing)(xing)。我公司(si)利用(yong)自身技術優勢研制了系(xi)列(lie)接(jie)(jie)(jie)(jie)地(di)引(yin)下線導通測試(shi)儀。該儀器采用(yong)全新電(dian)(dian)(dian)(dian)(dian)源技術,具(ju)有體(ti)積小、重(zhong)(zhong)量輕(qing)、輸出(chu)電(dian)(dian)(dian)(dian)(dian)流大(da)(da)并且可(ke)根據負載大(da)(da)小自動調整等(deng)特(te)點(dian)。整機由單片機控制,自動完成自檢、數據處(chu)理(li)、顯示、打印等(deng)功(gong)能,具(ju)有自動放電(dian)(dian)(dian)(dian)(dian)和放電(dian)(dian)(dian)(dian)(dian)指示功(gong)能。儀器測試(shi)精度(du)高,操作簡便,可(ke)實(shi)現接(jie)(jie)(jie)(jie)地(di)電(dian)(dian)(dian)(dian)(dian)阻的(de)(de)快速測量。
一、WBDT-V接地引下線導通快速分析儀**措施(shi)
使(shi)用(yong)本(ben)儀器前(qian)一(yi)定要(yao)認真閱讀本(ben)手冊。
儀器(qi)(qi)的操作者應具備一般電氣設備或儀器(qi)(qi)的使用常識。
本儀器(qi)戶內外均(jun)可使用,但(dan)應避開雨淋、腐蝕氣(qi)體、塵埃過濃、高(gao)溫(wen)、陽光直射等場所。
儀表應避(bi)免劇烈振動。
對儀器的維修(xiu)、護理和調整應(ying)由專業人員進行(xing)。
測(ce)試(shi)完畢后(hou)一(yi)定要等放電(dian)報警聲停止(zhi)后(hou)再關閉電(dian)源,拆除測(ce)試(shi)線。
在測試過程(cheng)中,禁(jin)止(zhi)移動測試夾(jia)和供電線(xian)路。
二、WBDT-V接地引下線導通快速分析儀性(xing)能特點
儀器輸出電流大,測(ce)量范圍寬,操作簡便(bian);
儀器具有完善的反電(dian)勢保護(hu)功能(neng),音響(xiang)放電(dian)報警,放電(dian)指示清晰,減(jian)少誤操作;
儀(yi)器裝(zhuang)有打(da)印機,可(ke)隨時打(da)印測試(shi)數(shu)據;
儀(yi)器具有(you)實時時鐘,并可連同測試(shi)記(ji)錄一起保(bao)(bao)存(cun)、打印,方便用(yong)戶(hu)保(bao)(bao)存(cun)、查閱;
儀(yi)器內(nei)部可以(yi)長久存儲測試數據200條(可擴(kuo)展),還可以使用優(you)盤(pan)存儲數據方便用戶導入電(dian)腦處理(li)。
儀器具(ju)有適(shi)用溫度寬,精度高(gao),防(fang)震,抗(kang)干擾,體(ti)積小,重(zhong)量輕(qing),攜帶方便等特點。
三(san)、WBDT-V接地引下線導通快速分析儀技術指標
測試電流:0.2A、1A、5A、10A四(si)檔
測試范圍:0.2 A 10 Ω ~ 100Ω
1 A 100mΩ ~ 20 Ω
5 A 10 mΩ ~ 4 Ω
10 A 1 mΩ ~ 2 Ω
準(zhun)確度:±(讀數×0.2%+2字)
*高分辨(bian)率: 0.1μΩ
工作溫度:-5~40℃;環(huan)境濕(shi)度(du):≤90%RH,無(wu)結露
工作電(dian)源:AC220V±10%,50HZ±1HZ
體積(ji):390×280×200mm
重量:7Kg(不包括(kuo)測試線)
四、WBDT-V接地引下線導通快速分析儀面板功能(neng)介紹
儀(yi)器面板見圖(tu)一。
電源開關(guan):整機(ji)電源輸入口,帶有交流插(cha)座(zuo),保險倉和(he)開關(guan)。
: 接地(di)(di)柱(zhu),為整機外殼接地(di)(di)用,屬保護地(di)(di)。
V+、V-: 電壓輸入端(duan)子。
I+、I-: 電流輸出端子。
顯示(shi)器: 128×64點陣液晶顯示器(qi),人機交互界(jie)面。
打印機: 打印輸出直流電阻測試結果。
USB: 優盤接口
RS232: 儀器(qi)與計算機連接的通訊接口
返回(hui)鍵: 返回上(shang)級菜(cai)單界(jie)面或(huo)取消當前操(cao)作。
選(xuan)擇鍵: 在儀器操作過程中移動光標。
確認鍵: 修改參數(shu)或執(zhi)行所選操作。
五、WBDT-V接地引下線導通快速分析儀使用(yong)說明
1、儀器開(kai)機顯示畫面
打(da)開(kai)(kai)電源(yuan)開(kai)(kai)關(開(kai)(kai)關上I為(wei)開(kai)(kai),O為(wei)關),儀器顯(xian)示(shi)區將顯(xian)示(shi)圖(tu)三界面。
2、時鐘界(jie)面(mian)
放電檢測完(wan)畢后,儀(yi)器自動進入時鐘界面。
此界面實(shi)時(shi)(shi)(shi)顯(xian)示系統時(shi)(shi)(shi)鐘(zhong),用戶可按(an)(an)“確認”鍵(jian)(jian)直接進入主菜單(dan)界面。如用戶想(xiang)修改(gai)時(shi)(shi)(shi)鐘(zhong),可按(an)(an)選擇鍵(jian)(jian)移動光(guang)標(字體(ti)反白顯(xian)示為光(guang)標選中(zhong)狀態),此時(shi)(shi)(shi)按(an)(an)“確認”鍵(jian)(jian)可實(shi)現(xian)數值加(jia)一功能,當(dang)光(guang)標移動到“確定”按(an)(an)鈕時(shi)(shi)(shi),按(an)(an)“確認”鍵(jian)(jian)即可設定時(shi)(shi)(shi)鐘(zhong)并進入主菜單(dan)界面,如中(zhong)途用戶不想(xiang)修改(gai)時(shi)(shi)(shi)鐘(zhong)了,可按(an)(an)“返回”鍵(jian)(jian)推出設定界面,儀器仍將實(shi)時(shi)(shi)(shi)刷新時(shi)(shi)(shi)鐘(zhong),再按(an)(an)“確認”鍵(jian)(jian)即可進入主菜單(dan)界面。
3、主菜單(dan)界面
按“選擇”鍵移動光標,按“確認”鍵進(jin)入所(suo)選菜單,按“返(fan)回”鍵回到上一頁。
3.1導通測試(shi)菜單
按“選(xuan)擇”移動光(guang)(guang)標,當光(guang)(guang)標選(xuan)中“電流選(xuan)擇:xxxA”時,按“確認(ren)”可修(xiu)改電流值(0.2A→1A→5A→10A→0.2A循環(huan)顯示);當光標移動到“確定”按(an)鈕時,按(an)確認鍵(jian)即可按(an)當前選定的測試電流進(jin)行測試,進(jin)入圖(tu)(tu)七→圖(tu)(tu)八→圖(tu)(tu)九(jiu)界(jie)面(mian)。
當進度條到達右端,表示測試(shi)完畢,將(jiang)顯示測試(shi)結果如(ru)圖十
此時(shi)界面(mian)顯示(shi)的電(dian)阻值為實時(shi)測量值,用戶可(ke)按(an)“選(xuan)擇”鍵選(xuan)擇“保存”或是“打印”,按(an)“確認”鍵執行(xing)所選(xuan)操作,按(an)“返回”鍵儀器停止測試并開始放(fang)電(dian)如圖十一
放(fang)電(dian)完畢(bi)后,儀器將返回到圖六界面。
當在圖(tu)十界面中(zhong)用(yong)戶選擇保存時,儀器(qi)將提示用(yong)戶選擇存儲介質(zhi)如圖(tu)十二
按(an)“選(xuan)擇(ze)”鍵移動光標,按(an)“確認”鍵保(bao)存(cun)到相(xiang)應存(cun)儲介(jie)質(zhi)并(bing)返回到圖十(shi)界面(mian),實時(shi)刷新測量結(jie)果(guo),也可不保(bao)存(cun)按(an)“返回”回到圖十(shi)界面(mian),實時(shi)刷新測量結(jie)果(guo)。
注:整(zheng)個測試過程中切勿拆(chai)線(xian),待放電完畢方可拆(chai)線(xian)。
3.2、數據存取菜單(dan)
按“選擇”鍵(jian)移動光標,按“確認”鍵(jian)執行所(suo)選操作,按“返(fan)回(hui)(hui)”鍵(jian)回(hui)(hui)到主菜單。
六、注(zhu)意事項
測試過程中嚴禁拆除測試下和切斷系統電源。
在拆線(xian)前,一定要(yao)等放電結束后,報警聲停止,再(zai)進行拆線(xian)。
如果測試線(xian)沒接(jie)好(hao),儀器會自動提示(shi)“電源開路”。這時須檢查線(xian)路是否有(you)正確或沒接(jie)牢固(gu),然后按復位(wei)鍵重(zhong)新(xin)測量。
七、售(shou)后服務
1、凡購本公司產品隨機(ji)攜帶產品保修單,訂購產品交(jiao)貨時,請當(dang)場檢驗并填(tian)好保修單。
2、自購機(ji)之日起,憑保修(xiu)單(dan)保修(xiu)二年,終身維(wei)護。在(zai)保修(xiu)期內(nei),維(wei)修(xiu)不收維(wei)修(xiu)費;保修(xiu)期外,維(wei)修(xiu)調試收取適當費用(yong)。
3、屬下(xia)列(lie)情(qing)況之一者不予(yu)保修:
1)用戶(hu)對(dui)儀器有自行拆卸或對(dui)儀器工藝(yi)結(jie)構(gou)有人為改變。
2)因用戶保(bao)管(guan)或使用不當造成(cheng)儀器的嚴(yan)重損壞。
3)屬于用戶其它原因造成的損壞(huai)。
裝箱單
儀(yi)器名稱:接地(di)引下線導通測試儀(yi)
測試儀(yi)主(zhu)機
|
一臺
|
測試線
|
二條(紅黑(hei))
|
三芯電源線
|
一條
|
接地(di)線
|
一條(tiao)
|
保險管(3A)
|
三(san)支(zhi)
|
打印紙
|
二卷(juan)
|
測(ce)試報告
|
一份
|
裝箱單
|
一張
|
使(shi)用說明(ming)書
|
一本
|
合(he)格證 保修卡
|
一張(zhang)
|