地下管線故(gu)障點探測儀技(ji)術指標第1章 概(gai) 述
WBST-200管(guan)線(xian)(xian)(xian)(xian)綜合探(tan)(tan)測(ce)(ce)儀(yi)由(you)一(yi)臺發射機、一(yi)臺接收機及附件構成(cheng),用于地下管(guan)線(xian)(xian)(xian)(xian)路由(you)的(de)精準(zhun)定(ding)位(wei)、埋深測(ce)(ce)量(liang)和長距(ju)離的(de)追蹤以及對管(guan)線(xian)(xian)(xian)(xian)絕緣(yuan)故障(zhang)點的(de)測(ce)(ce)量(liang)查找。管(guan)線(xian)(xian)(xian)(xian)綜合探(tan)(tan)測(ce)(ce)儀(yi)采(cai)用了(le)多線(xian)(xian)(xian)(xian)圈(quan)電(dian)磁技(ji)術,提高了(le)管(guan)線(xian)(xian)(xian)(xian)定(ding)位(wei)定(ding)深的(de)精度和目標管(guan)線(xian)(xian)(xian)(xian)的(de)識別能力,在管(guan)線(xian)(xian)(xian)(xian)密(mi)集復雜的(de)區域也(ye)能準(zhun)確地對目標管(guan)線(xian)(xian)(xian)(xian)進行追蹤和定(ding)位(wei)。因而管(guan)線(xian)(xian)(xian)(xian)綜合探(tan)(tan)測(ce)(ce)儀(yi)在電(dian)信、網通(tong)、移動、聯通(tong)、鐵通(tong)、電(dian)力、自來水(shui)、煤氣、物探(tan)(tan)、石化和市(shi)政等行業得到了(le)廣(guang)泛(fan)的(de)應用。
WBST-200管線綜合探測儀提供多種可選附(fu)件,從而增加了它們的用途,擴(kuo)展了它們的應用范圍。
使用管線綜合探測儀之前請閱讀本(ben)手(shou)冊(ce)。
地下管線故(gu)障(zhang)點探測儀(yi)技術指(zhi)標(biao)第(di)2章 主(zhu)要功能、特點和技術(shu)指標(biao)
2.1主(zhu)要(yao)功能(neng)
1、測定地下(xia)管線的(de)路由(you)
2、測定地下管線的埋(mai)深
3、多管線(xian)的情(qing)況(kuang)下目標管線(xian)的識別
4、檢測并定位管線絕緣故障點
地下(xia)管線(xian)故(gu)障點(dian)探(tan)測儀技(ji)術指標2.2主要特(te)點
1、采(cai)用先進的信號(hao)處理技術、*新(xin)的集成電(dian)路元器件以達到優異的測(ce)試(shi)性能。
2、測量信(xin)號的(de)多種發送方式:
(1)注(zhu)入法:用于有注(zhu)入點的管(guan)線。
(2)鉗夾法(fa):用于被測管(guan)線有一段外露,便于鉗夾夾鉗的管(guan)線。
(3)感應(ying)法:用于無注入點或無外露的管線。
3、多種測(ce)量頻率:有480Hz、7.7KHz、31KHz和(he)61KHz四種有(you)源頻率(lv)以及(ji)電力線(xian)纜(lan)的50Hz無源頻率(lv);用戶可以根據(ju)環境的不同(tong)進行(xing)選擇(如需(xu)要采用特殊(shu)測量頻率(lv),請在定貨合同(tong)中注明)。
4、提(ti)高測試效率的不(bu)同的定(ding)位模式和功能:
(1)峰值模式:通過測量(liang)信號的極(ji)大值來(lai)確定路(lu)由的位置。
(2)谷值模式:通(tong)過測量信號的(de)極(ji)小值來確定路由(you)的(de)位置。
(3)路由定(ding)向:直觀、迅速地指示路由的方(fang)向。
(4)絕(jue)緣故(gu)障(zhang)查找(FF): 查找并定位出管線(xian)絕緣惡化(hua)導致的(de)故(gu)障(zhang)點。
(5)聽診器:通過聽診頭(tou)從眾多管線中識(shi)別(bie)出(chu)信號所加載的管線。
5、輔助功能:
(1)接收(shou)(shou)增益(yi)自(zi)動調(diao)節:自(zi)動調(diao)節接收(shou)(shou)機的增益(yi)以使(shi)接收(shou)(shou)機處(chu)于(yu)優化(hua)狀態,免去了(le)手(shou)動調(diao)節的繁(fan)瑣。
(2)聲響(xiang)功能:接收機通過喇叭發(fa)出的音調變(bian)化直觀地反映測量的信號大(da)小。
(3)管(guan)線(xian)狀態檢測:發(fa)射機(ji)(ji)(ji)在(zai)做注入模(mo)式時(shi),首(shou)先檢測管(guan)線(xian)的絕(jue)緣電(dian)阻,殘(can)(can)余電(dian)壓,再將信(xin)(xin)號施加到目標管(guan)線(xian)上。當(dang)管(guan)線(xian)上絕(jue)緣電(dian)阻較(jiao)小(近于對地短路(lu))發(fa)射機(ji)(ji)(ji)將自動退出該模(mo)式,當(dang)殘(can)(can)余電(dian)壓較(jiao)大時(shi)發(fa)射機(ji)(ji)(ji)告(gao)警(jing),操作(zuo)人員(yuan)應立即停止(zhi)信(xin)(xin)號的加載,關(guan)閉發(fa)射機(ji)(ji)(ji)。
(4)電池(chi)電量檢測:電池(chi)電量的實(shi)時(shi)檢測,當電量低到保(bao)護值時(shi)會發出(chu)報警自動關機。
(5)節電功能:發射機(ji)開機(ji)30秒左右(you)未按其它鍵、接收(shou)機開機操作后,若(ruo)10分鐘(zhong)左右未再按其它鍵時,機(ji)器(qi)會(hui)自動關機(ji),以(yi)節(jie)省電池(chi)電能。
2.3 技術指標
2.3.1發射機技術指標(biao)
注入(ru)方式
|
480Hz、7.7KHz、31KHz和61KHz
|
感(gan)應方式(shi)
|
31KHz、61KHz
|
鉗夾方式
|
31KHz
|
故障查(cha)找
|
8/480Hz復合頻率
|
輸(shu)出電壓(ya)
|
0-400Vp-p 根據絕緣情況(kuang)變化(hua)
|
輸出波(bo)形(xing)
|
正弦(xian)波(bo)
|
電 源(yuan)
|
11.1VDC 4.4AH 鋰電池(chi)
|
*大輸出功率
|
10W
|
2.3.2接收機技(ji)術指標(biao)
功耗
|
<1.0W
|
電源
|
11.1VDC 1.8AH 鋰電池
|
*大(da)測試線(xian)路埋深
|
4.5米 (正常(chang)情(qing)況下)
|
測試線路埋深誤差
|
±0.05h±5cm (h為管線的埋深(shen))
|
測試線路(lu)路(lu)由誤差
|
≤5cm
|
利用注入法測試管線(xian)路由及埋深有(you)效長度
|
不小(xiao)于10Km(正(zheng)常情況(kuang)下)
|
利用(yong)感應法測試線路路由(you)及埋深有效長度(du)
|
不小(xiao)于3Km(正常情況下)
|
利(li)用鉗夾法測試線路路由及埋深有效長度
|
不小于6Km(正常情況下)
|
絕(jue)緣(yuan)故障查找
|
絕緣(yuan)惡化從(cong)短路直至2MΩ
|
注:正常情況下指所測(ce)試的管線(xian)在上述測(ce)量范圍內沒有(you)絕緣故障及其它干擾。
2.3.3 環境要求
工作溫度
|
-20℃~+50℃
|
存儲(chu)溫度(du)
|
-40℃-70℃
|
相對濕(shi)度
|
10%~90%
|
大氣壓力
|
86~106KPa
|
環境噪聲
|
≤60dB
|
2.3.4 物理(li)特性
組件一(yi)(儀(yi)表(biao)組合)
名(ming) 稱
|
重(zhong)量(Kg)
|
外形尺(chi)寸(mm)
|
發射(she)機(ji)
|
3.4
|
348*239*175
|
接收機
|
2.6
|
648*260*130
|
整機
|
14
|
790*250*420
|
用(yong)戶可以選配組件(jian):
組件二(故(gu)障查(cha)找(zhao)支架)
名 稱(cheng)
|
重(zhong)量(Kg)
|
外形尺寸(mm)
|
故障查找支架
|
1.5
|
525*672*25
|
地下管線故障點探測(ce)儀技(ji)術指標(biao)第三章(zhang) 工作原理
3.1探測儀(yi)路由查找原理(li)
根據電(dian)(dian)磁(ci)(ci)理(li)論,交變的(de)(de)(de)(de)電(dian)(dian)流(liu)(liu)在(zai)空間(jian)產生(sheng)一(yi)變化的(de)(de)(de)(de)磁(ci)(ci)場,其關系(xi)滿(man)足安(an)培環路定律(lv)。如果周(zhou)(zhou)圍(wei)是均(jun)勻介質,加載交流(liu)(liu)電(dian)(dian)流(liu)(liu)的(de)(de)(de)(de)導(dao)體(ti)足夠長(chang)、直(zhi)時,在(zai)該(gai)導(dao)體(ti)周(zhou)(zhou)圍(wei)產生(sheng)一(yi)個(ge)同軸(zhou)的(de)(de)(de)(de)交流(liu)(liu)電(dian)(dian)磁(ci)(ci)場,磁(ci)(ci)場強度(du)的(de)(de)(de)(de)大小(xiao)正比于(yu)(yu)電(dian)(dian)流(liu)(liu),反比于(yu)(yu)到導(dao)體(ti)的(de)(de)(de)(de)距離。如將一(yi)線圈(quan)(quan)置于(yu)(yu)這(zhe)個(ge)磁(ci)(ci)場中(zhong),在(zai)線圈(quan)(quan)內將感(gan)(gan)應產生(sheng)一(yi)個(ge)同頻率的(de)(de)(de)(de)交流(liu)(liu)電(dian)(dian)壓,感(gan)(gan)應電(dian)(dian)壓的(de)(de)(de)(de)大小(xiao)取決于(yu)(yu)該(gai)線圈(quan)(quan)在(zai)磁(ci)(ci)場中(zhong)的(de)(de)(de)(de)位置,當磁(ci)(ci)力(li)線方(fang)向(xiang)與線圈(quan)(quan)軸(zhou)向(xiang)平(ping)行時,線圈(quan)(quan)感(gan)(gan)應的(de)(de)(de)(de)電(dian)(dian)壓水平(ping)分量(liang)呈(cheng)極大,如圖3.1所(suo)(suo)示(shi);當線圈(quan)(quan)軸(zhou)向(xiang)與磁(ci)(ci)力(li)線方(fang)向(xiang)垂直(zhi)時,感(gan)(gan)應的(de)(de)(de)(de)電(dian)(dian)壓水平(ping)分量(liang)*小(xiao),為(wei)極小(xiao)值;如圖3.2所(suo)(suo)示(shi)。探測(ce)儀正是利(li)用這(zhe)一(yi)特點實現埋于(yu)(yu)地下(xia)的(de)(de)(de)(de)管線的(de)(de)(de)(de)路由查找。這(zhe)兩種(zhong)極大值、極小(xiao)值的(de)(de)(de)(de)探測(ce)方(fang)法即對應測(ce)量(liang)路由的(de)(de)(de)(de)峰值、谷值法。
3.2探(tan)測儀埋(mai)深(shen)測量原理
接收機(ji)內有(you)上下兩個相同的(de)水平(ping)放置的(de)線(xian)圈,它(ta)們之間的(de)距(ju)離(li)已知(zhi)。在路由正上方測量得到(dao)的(de)上下傳感線(xian)圈的(de)信號強度,按照電磁理論,可以反推算出未知(zhi)的(de)目標管線(xian)埋深大小。
假設接收機內兩平(ping)行的探測(ce)線圈的中心距為(wei)L,在路由的(de)正上方檢(jian)測到的(de)信(xin)號分別為v1、v2,則埋(mai)于(yu)地下D處的管(guan)線理(li)想(xiang)情況下滿(man)足公式:D=L/(V2/V1-1)
探測(ce)儀正是利用這樣的關系(xi)實現直讀法測(ce)量(liang)管線(xian)的埋深。
3.3探測儀(yi)絕(jue)緣故(gu)障查找(zhao)原(yuan)理
直(zhi)埋于地下(xia)的(de)管線外層多包(bao)以絕(jue)(jue)緣護套,正常(chang)的(de)情況下(xia)對地應有極高(gao)的(de)阻抗(kang),但隨著時間的(de)推(tui)移(yi),因(yin)種(zhong)種(zhong)原因(yin)而導致管線的(de)絕(jue)(jue)緣性(xing)能逐步下(xia)降,等效的(de)絕(jue)(jue)緣電(dian)阻可降為幾MΩ、幾(ji)十(shi)KΩ,直(zhi)至(zhi)完全對地(di)短路(lu),進一步惡(e)化便可導致(zhi)管(guan)線的斷裂,造(zao)成(cheng)更大的損失(shi)。及(ji)時地(di)查找出(chu)管(guan)線的絕緣故障點,是(shi)管(guan)線維(wei)護工作的重(zhong)要(yao)一環(huan)。
采(cai)(cai)用探測(ce)儀的(de)絕緣故(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang)查找(zhao)功能(neng)(FF)便(bian)(bian)可夠迅速及(ji)時地(di)(di)(di)檢(jian)測(ce)出管(guan)線的(de)絕緣故(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang)點。發射(she)機采(cai)(cai)用直(zhi)接注入工作方式,將(jiang)故(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang)查找(zhao)的(de)專用信(xin)號加至管(guan)線上,如(ru)圖3-4所示(shi)。信(xin)號在故(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang)點處通過(guo)大地(di)(di)(di)向(xiang)外泄(xie)漏(lou),電位(wei)大小(xiao)則以故(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang)點為(wei)中心,球(qiu)面型徑(jing)向(xiang)地(di)(di)(di)非線性衰減。將(jiang)與(yu)接收機相連的(de)輔助故(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang)查找(zhao)支(zhi)架(jia)插入地(di)(di)(di)表面,獲取泄(xie)漏(lou)的(de)信(xin)號特性,即可測(ce)量出故(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang)點所在方向(xiang)。按接收機顯示(shi)的(de)指示(shi)箭頭(tou),通過(guo)多次的(de)反復,*終便(bian)(bian)可查找(zhao)出泄(xie)漏(lou)信(xin)號的(de)故(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang)點。
地下管線(xian)故障點探測儀技術指標第四章 操(cao)作簡介
4.1 發射機操(cao)作(zuo)簡介
發(fa)射機的面板圖(tu):
發射機采(cai)用了高(gao)性能(neng)(neng)微(wei)處理器進行控制,漢字(zi)顯示界面(mian),操作(zuo)直觀(guan)方(fang)便。具(ju)有輸出信(xin)號強度記憶保持,注入(ru)方(fang)式下實時監(jian)測輸出電(dian)流大小功能(neng)(neng)。每次按鍵將(jiang)點亮背光,8秒后自動熄滅,以節省電(dian)池能(neng)(neng)量。
4.1.1 按鍵功能說明
4.1.2 顯(xian)示屏功(gong)能說(shuo)明
發(fa)射機正常工(gong)作時的(de)界面如圖所(suo)示(shi),這是注入模式測量下(xia)的(de)典型畫(hua)面。
其中(zhong):
:當(dang)前電(dian)池狀態,中填柵格分五(wu)種圖(tu)示表示。一旦檢測到電(dian)池電(dian)壓低于保護值時即告(gao)警并(bing)自動關(guan)機。
480Hz: 對應當前的(de)頻率選擇(ze),如想修改(gai)發射(she)信號(hao)的(de)頻率,必(bi)須首先退出發射(she)狀態。可(ke)能的(de)頻率選擇(ze)取決(jue)于(yu)信號(hao)發射(she)模(mo)式(shi),請參見技術指標一節(jie)。
10%:為信號輸出的強度。通過鍵(jian)可以增大或減小調節。范圍從0%至(zhi)100%。
6mA:對于(yu)注入模式,界面上(shang)還(huan)顯示了(le)當(dang)前發(fa)射到管(guan)線中的(de)電(dian)流大小,如(ru)圖(tu)示的(de)6mA。這(zhe)一值(zhi)會因管線(xian)傳輸過程中逐(zhu)漸減小,和遠(yuan)端接收(shou)機(ji)的電流測量值(zhi)可能相差較大。
: 動畫的發射圖符動態地表(biao)現了運(yun)行狀況。
4.1.3發射(she)機(ji)的(de)基本使(shi)用方法
發(fa)(fa)射(she)機(ji)有四種工作模(mo)式:注入、感應、鉗夾(jia)(jia)和(he)故障(zhang)(zhang)查找(zhao)。根據測試(shi)地點(dian)的(de)(de)實際(ji)情(qing)況和(he)目的(de)(de)選(xuan)擇其中之(zhi)一(yi)。一(yi)般的(de)(de)管(guan)(guan)線(xian)(xian)路(lu)由查找(zhao)和(he)埋深測量(liang)時(shi),可(ke)能(neng)的(de)(de)情(qing)況下優(you)選(xuan)注入法(fa),但(dan)它必須要(yao)能(neng)將發(fa)(fa)射(she)機(ji)的(de)(de)金(jin)屬線(xian)(xian)夾(jia)(jia)(紅色)直(zhi)接連接到管(guan)(guan)線(xian)(xian)上去(qu),例如夾(jia)(jia)到通信(xin)線(xian)(xian)纜(lan)的(de)(de)出(chu)線(xian)(xian)端(duan)子、金(jin)屬管(guan)(guan)道(dao)連接的(de)(de)螺(luo)栓等。鉗夾(jia)(jia)法(fa)的(de)(de)效率(lv)居中,但(dan)也必須測試(shi)管(guan)(guan)線(xian)(xian)要(yao)有一(yi)段暴露在外,如檢查井(jing)、人井(jing)或進出(chu)入房(fang)間(jian)的(de)(de)管(guan)(guan)道(dao),鉗夾(jia)(jia)能(neng)夾(jia)(jia)住管(guan)(guan)線(xian)(xian)的(de)(de)地方。*后的(de)(de)方法(fa)是(shi)感應法(fa),在管(guan)(guan)線(xian)(xian)可(ke)能(neng)經過的(de)(de)上方,打開發(fa)(fa)射(she)天線(xian)(xian),和(he)接收機(ji)配合,反復幾次調整,*終(zhong)確定一(yi)個*佳的(de)(de)方位(wei),使得發(fa)(fa)射(she)的(de)(de)效率(lv)*大。而故障(zhang)(zhang)查找(zhao)模(mo)式主要(yao)用(yong)于查找(zhao)并定位(wei)出(chu)管(guan)(guan)線(xian)(xian)絕緣(yuan)惡化導致的(de)(de)故障(zhang)(zhang)點(dian)。
按下發(fa)射(she)機鍵(jian)后,首(shou)先儀器(qi)對電池電量測量,由于發射機滿功(gong)率工作(zuo)(zuo)時耗電較大,事先的檢查(cha)給操作(zuo)(zuo)人員(yuan)提(ti)供了預(yu)算(suan)可能工作(zuo)(zuo)的時間。
發(fa)射機默認的工作(zuo)模(mo)式是(shi)注入法,通過鍵可作其(qi)它模式的切換,依順序為(wei)注入、感應、鉗夾和(he)故障查找。
頻率的選擇(ze)依模式(shi)而(er)不同,可參見(jian)技術指標一節。頻率的改變(bian)只能(neng)在(zai)信號未發(fa)射的準備狀態進行,換言之,在(zai)信號發(fa)射已啟動后想(xiang)改變(bian)成其它的頻率,則先要按(an)鍵退出發射后(hou)才(cai)能(neng)再做(zuo)改動。
四種工作模(mo)式下發射機都分別設定了一(yi)個基本的(de)發射強度(du)值,分別為10%,80%,50%和10%。無論在準備狀態(tai)或(huo)發射(she)進行中都(dou)可以根(gen)據實際(ji)情況通(tong)過(guo) >發射機默認(ren)的工作模式是注入法,通過(guo)鍵(jian)來增大、減(jian)小調節輸出信(xin)號的(de)強度(du)。
信號的發射只有在按下鍵后才(cai)有功率(lv)向外輸出。在這之前的一切(qie)準(zhun)備工(gong)作都是(shi)**的,例如注(zhu)入法下(xia)固定接(jie)地插針(zhen),將紅色信號輸出夾夾住出線端子等(deng)工(gong)作,一旦信號發射(she)后,由于(yu)輸出電壓可能高(gao)達上百(bai)伏,這時(shi)再去調(diao)整發射(she)機的接(jie)線狀況就(jiu)有可能很危險了,切(qie)記再次按(an)下(xia) ?式是注(zhu)入法,通過(guo)鍵,確定已退(tui)出發射狀態(tai)后再進行!
是否處于發射狀態,液晶屏上的(de)運行圖符直觀形象(xiang)地表現了這(zhe)點。
發(fa)(fa)射(she)機(ji)在大功率(lv)發(fa)(fa)射(she)時(如感應模式下),電(dian)池電(dian)量(liang)注意不要耗到*后(hou)的(de)一個柵(zha)格,那時雖(sui)然還能工作且沒(mei)到自動關(guan)機(ji)狀(zhuang)態(tai),但發(fa)(fa)射(she)的(de)功率(lv)已(yi)不穩定,接收機(ji)的(de)測量(liang)誤差(cha)較(jiao)大。
4.1.4發射機的配(pei)件
1、信號輸出線
在注入(ru)模式下(xia),通過輸出線(xian)將發射機(ji)信(xin)號直接加載到目(mu)標管(guan)線(xian)上(shang)。紅色(se)夾(jia)接被測管(guan)線(xian),黑色(se)夾(jia)接地(di)。
2、接地棒
接地(di)棒用來接地(di),提(ti)供(gong)信號回路。
3、鉗(qian)夾
對(dui)多條同向管線(xian)進行識(shi)別(bie)時,特別(bie)是(shi)管道里(li)的管線(xian)用原有方(fang)(fang)式很難識(shi)別(bie),鉗夾是(shi)一種比較好的方(fang)(fang)法,可以直(zhi)接套(tao)住目標管線(xian)進行加載(zai)信號。
4、故障查找支架(選(xuan)配件)
專(zhuan)用的故障查找支架(jia)連接接收機(ji)可(ke)查找出(chu)管(guan)線(xian)絕緣惡化(hua)導致的故障點。
技術指(zhi)標(biao)
發射機
1. 輸出(chu)方式:直連(lian)輸出(chu)、輻射感應、卡鉗耦合(選(xuan)配)、查障升壓器(選(xuan)配)。
2. 輸出頻率:640Hz、1280Hz、10kHz、33kHz、82kHz、197kHz。
3. 輸出(chu)功率:10W,10檔可(ke)調,全自動實時阻抗(kang)匹配。
4. 直(zhi)連輸(shu)出電壓(ya):150Vpp。
5. 過載和短路保護(hu)。
6. 人機界(jie)面:320×240點(dian)陣液晶顯示器。
7. 內置電池:4節18650鋰離子(zi)電(dian)池,標稱7.4V,6.8Ah。
接收機
1. 輸(shu)入方式:內置接收線圈、柔性卡(ka)鉗(qian)(選配)、聽診(zhen)器(選配)、查障A字架(選配)。
2. 接收頻率:
主動探(tan)測頻率:640Hz、1280Hz、10kHz、33kHz、82kHz、197kHz。
工頻被動探測頻率:50Hz/60Hz和250Hz/300Hz(用戶可配置)。
射頻被動探測頻段:中心頻率(lv)分別為10kHz、33kHz、82kHz。
3. 管線探測模式:寬峰法、窄峰法、音谷(gu)法。
4. 電纜鑒別模式:柔性卡鉗(選(xuan)配)智能鑒別和電流測量、聽診器(選配)鑒(jian)別(bie)。
5. 人機界面(mian):320×240點(dian)陣液晶顯示器(qi)。
6. 內置(zhi)電池:2節18650鋰(li)離(li)子電池,標稱7.4V,3.4Ah。